CIM Model Comparison Β·18v07 baseline β†’ 18v08 destination
Scope: Grid Β· compared 2026-11-04 13:12:23 Β· cim-compare 2.3.1
Print or save as PDFOpens your browser’s print dialog (or press Ctrl+P, ⌘P on a Mac).β€’ To save a PDF, choose Save as PDF (or Microsoft Print to PDF) as the printer.β€’ Choose Landscape if the browser doesn’t pick it.β€’ Turn off Headers and footers for a cleaner page.β€’ Leave Background graphics on so the change colours print.Wait for diagram images to load in large reports.
Packages1 moved
Classes4 moved4 changed
Diagrams54 changed
Click a count to show only those itemsp
Added β€” only in destinationDeleted β€” only in baselineMoved β€” same GUID, different packageChanged β€” same GUID and package; properties or members differIdenticalPackage (unchanged itself)struckinserted β€” destination text with baseline wording struck (notes, role notes, role names, multiplicities); the shows the notes and every changed propertyBlue β€” a changed attribute type (the new type)
β–ΆGridi
Package notes
This top package includes the CIM model related to the grid.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{21D32832-FF64-4213-B81C-55ACE35EEBFF}
Package notes
This top package includes the CIM model related to the grid.
β–ΆBasei
Package notes
Content of the base CIM. The information in the entire clause "Common Information Model Base Package" is reproduced from the UML with the permission of UCAIug.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{20A2C6D8-4765-466f-AD75-5E1B3CAF4E8D}
Package notes
Content of the base CIM. The information in the entire clause "Common Information Model Base Package" is reproduced from the UML with the permission of UCAIug.
β–ΆCorei
Package notes
Contains the core PowerSystemResource and ConductingEquipment entities shared by all applications plus common collections of those entities. Not all applications require all the Core entities. This package does not depend on any other package except the Domain package, but most of the other packages have associations and generalizations that depend on it.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{6A503B72-6E15-4cd1-B92D-DDF6D14DBE29}
Package notes
Contains the core PowerSystemResource and ConductingEquipment entities shared by all applications plus common collections of those entities. Not all applications require all the Core entities. This package does not depend on any other package except the Domain package, but most of the other packages have associations and generalizations that depend on it.
Moved classes (1)
β–Άβš™BoundaryPointΒ«EuropeanΒ»i
Class notes
Designates a connection point at which one or more model authority sets shall connect to. The location of the connection point as well as other properties are agreed between organisations responsible for the interconnection, hence all attributes of the class represent this agreement. It is primarily used in a boundary model authority set which can contain one or many BoundaryPoint-s among other Equipment-s and their connections.
Class metadata β€” changes
BaselineDestination
ParentPackageExtEuCoreCore
Tagged values β€” changes
BaselineDestination
no changes
MOVEDfrom ExtEuCore{22106B32-87E4-4296-B0FC-1F9DB3D9D70A}
Class notes
Designates a connection point at which one or more model authority sets shall connect to. The location of the connection point as well as other properties are agreed between organisations responsible for the interconnection, hence all attributes of the class represent this agreement. It is primarily used in a boundary model authority set which can contain one or many BoundaryPoint-s among other Equipment-s and their connections.
β–€Metadata
BaselineDestination
ParentPackageExtEuCoreCore
Class 'BoundaryPoint' has no other changes. The shows its notes and every changed property.
Changed classes (1)
β–Άβš™IdentifiedObjecti
Class notes
This is a root class to provide common identification for all classes needing identification and naming attributes.
Class metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
CHANGED{055C5806-E9D8-4a7a-9307-DAF7C31763C7}
Class notes
This is a root class to provide common identification for all classes needing identification and naming attributes.
≑Attributes
AttributeBaselineDestinationNotes (destination, redlined)
energyIdentCodeEici{E90B8A07-01BD-47dd-84D1-C456D09C4722}show detailsdid not existString [0..1]The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.
Attribute notes
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.
Attribute metadata β€” changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
NameenergyIdentCodeEic
Scale0
Scopepublic
Staticfalse
StereotypeEuropean
TypeString
UpperBound1
Tagged values β€” changes
BaselineDestination
none
shortNamei{D6D2E135-8918-4a50-98C3-2BB3CD8CBE01}show detailsdid not existString [0..1]The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.
Attribute notes
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.
Attribute metadata β€” changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
NameshortName
Scale0
Scopepublic
Staticfalse
StereotypeEuropean
TypeString
UpperBound1
Tagged values β€” changes
BaselineDestination
none
⇄Links
BaselineIdentifiedObject β†’ ExtEuIdentifiedObject
β†’
Destinationremoved from model
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExtEuIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed diagrams (5)
β–Άβ–¦CurveSchedulei
Diagram notes
This diagram shows the common model for curves and time dependent schedules.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{7DCA2E11-355A-47f2-9EF8-BEAEBD619E5D}
Diagram notes
This diagram shows the common model for curves and time dependent schedules.
β–¦Diagram
changed
Baseline
CurveSchedule (baseline)
Destination
CurveSchedule (destination)
β–Άβ–¦Maini
Diagram notes
This diagram shows the main classes needed for any application of the CIM for modelling transmission and generation systems.
Diagram metadata β€” changes
BaselineDestination
ModifiedDate2022-06-10 11:51:102023-10-24 06:07:21
CHANGED{F791662C-7488-4578-88E1-21352F9799CF}
Diagram notes
This diagram shows the main classes needed for any application of the CIM for modelling transmission and generation systems.
β–€Metadata
BaselineDestination
ModifiedDate2022-06-10 11:51:102023-10-24 06:07:21
β–¦Diagram
addedmoved or resized
Baseline
Main (baseline)
Destination
Main (destination)
Connectors 4 added Β· 11 labels movedhover a connector to outline the elements it joins
added(not in this model) – ConnectivityNode
addedBoundaryPoint – (not in this model)
addedBoundaryPoint – ConnectivityNode
addedConnectivityNode – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
β–Άβ–¦Namesi
Diagram notes
This diagram shows classes used to assign names to identified objects.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{E0451A91-94B6-4771-AA2F-2F1E5235FDE5}
Diagram notes
This diagram shows classes used to assign names to identified objects.
β–¦Diagram
changed
Baseline
Names (baseline)
Destination
Names (destination)
β–Άβ–¦OperatingSharei
Diagram notes
This diagram shows the common model for operating share.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{88289F74-ECDD-42e8-A693-6744785B1A0C}
Diagram notes
This diagram shows the common model for operating share.
β–¦Diagram
changed
Baseline
OperatingShare (baseline)
Destination
OperatingShare (destination)
β–Άβ–¦Reportingi
Diagram notes
This diagram shows the common model for ad-hoc reporting.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{25B521B8-89DF-4043-A8D0-B37B0F772597}
Diagram notes
This diagram shows the common model for ad-hoc reporting.
β–¦Diagram
changed
Baseline
Reporting (baseline)
Destination
Reporting (destination)
β–ΆWiresi
Package notes
An extension to the Core and Topology package that models information on the electrical characteristics of Transmission and Distribution networks. This package is used by network applications such as State Estimation, Load Flow and Optimal Power Flow.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{6C99E9CA-2035-4035-B77F-9217E17D86F4}
Package notes
An extension to the Core and Topology package that models information on the electrical characteristics of Transmission and Distribution networks. This package is used by network applications such as State Estimation, Load Flow and Optimal Power Flow.
Package 'Wires' has no changes to the 102 classes it contains.
Changed diagrams (5)
β–Άβ–¦InheritanceHierarchyi
Diagram notes
This diagram describes inheritance between classes in and related to the Wires package.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{D2B8C355-D454-4084-9966-12E8D7FF6875}
Diagram notes
This diagram describes inheritance between classes in and related to the Wires package.
β–¦Diagram
changed
Baseline
InheritanceHierarchy (baseline)
Destination
InheritanceHierarchy (destination)
β–Άβ–¦MutualCouplingi
Diagram notes
Shows mutual coupling models.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{7CE6A094-D43D-4851-8A1F-D1B06FA7B538}
Diagram notes
Shows mutual coupling models.
β–¦Diagram
changed
Baseline
MutualCoupling (baseline)
Destination
MutualCoupling (destination)
β–Άβ–¦NamingHierarchyPart1i
Diagram notes
The diagram shows the upper part of the naming hierarchy. The hierarchy is a way to organize and name equipment. Hence it is tightly related to the IdentifiedObject and it's attributes. The Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{422FB39E-1D47-45c4-8623-BADEED124BF6}
Diagram notes
The diagram shows the upper part of the naming hierarchy. The hierarchy is a way to organize and name equipment. Hence it is tightly related to the IdentifiedObject and it's attributes. The Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer.
β–¦Diagram
changed
Baseline
NamingHierarchyPart1 (baseline)
Destination
NamingHierarchyPart1 (destination)
β–Άβ–¦NamingHierarchyPart2i
Diagram notes
The diagram shows the lower part of the naming hierarchy. It shows how the Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer. For the subclasses of equipment container refer to part 1 of the diagram.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{3A72A435-5BA5-4809-A5DC-560573D58582}
Diagram notes
The diagram shows the lower part of the naming hierarchy. It shows how the Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer. For the subclasses of equipment container refer to part 1 of the diagram.
β–¦Diagram
changed
Baseline
NamingHierarchyPart2 (baseline)
Destination
NamingHierarchyPart2 (destination)
β–Άβ–¦Schedulesi
Diagram notes
Shows schedules of wires model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{18FA35BC-A253-4a57-A387-6D36B189A250}
Diagram notes
Shows schedules of wires model.
β–¦Diagram
changed
Baseline
Schedules (baseline)
Destination
Schedules (destination)
β–ΆGenerationi
Package notes
This package contains packages that have information for Unit Commitment and Economic Dispatch of hydro and thermal generating units, Load Forecasting, Automatic Generation Control, and unit modeling for Training Simulation.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{6B50A1FD-22E9-4abc-B0B7-F46BBD8B33AE}
Package notes
This package contains packages that have information for Unit Commitment and Economic Dispatch of hydro and thermal generating units, Load Forecasting, Automatic Generation Control, and unit modeling for Training Simulation.
β–ΆProductioni
Package notes
The production package is responsible for classes which describe various kinds of generators. These classes also provide production costing information which is used to economically allocate demand among committed units and calculate reserve quantities.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{39719C4D-64F6-4704-8202-8CAEF5179709}
Package notes
The production package is responsible for classes which describe various kinds of generators. These classes also provide production costing information which is used to economically allocate demand among committed units and calculate reserve quantities.
Moved classes (2)
β–Άβš™SolarPowerPlantΒ«EuropeanΒ»i
Class notes
Solar power plant.
Class metadata β€” changes
BaselineDestination
ParentPackageExtEuProductionProduction
Tagged values β€” changes
BaselineDestination
no changes
MOVEDfrom ExtEuProduction{FCAC387C-33C5-4446-AD70-4E6B02809D92}
Class notes
Solar power plant.
β–€Metadata
BaselineDestination
ParentPackageExtEuProductionProduction
Class 'SolarPowerPlant' has no other changes. The shows its notes and every changed property.
β–Άβš™WindPowerPlantΒ«EuropeanΒ»i
Class notes
Wind power plant.
Class metadata β€” changes
BaselineDestination
ParentPackageExtEuProductionProduction
Tagged values β€” changes
BaselineDestination
no changes
MOVEDfrom ExtEuProduction{52E21930-D9C8-4243-AF07-B57B20CE94B0}
Class notes
Wind power plant.
β–€Metadata
BaselineDestination
ParentPackageExtEuProductionProduction
Class 'WindPowerPlant' has no other changes. The shows its notes and every changed property.
Changed diagrams (2)
β–Άβ–¦Maini
Diagram notes
This diagram shows all classes included in the Production package that are needed by both Hydro and Thermal generation. It also shows key external classes that have associations with Production classes.
Diagram metadata β€” changes
BaselineDestination
ModifiedDate2022-06-10 12:06:252023-10-24 06:14:29
CHANGED{F9C40197-0210-4574-A263-DF81545A755B}
Diagram notes
This diagram shows all classes included in the Production package that are needed by both Hydro and Thermal generation. It also shows key external classes that have associations with Production classes.
β–€Metadata
BaselineDestination
ModifiedDate2022-06-10 12:06:252023-10-24 06:14:29
β–¦Diagram
addedchangedmoved or resized
Baseline
Main (baseline)
Destination
Main (destination)
Connectors 4 added Β· 1 rerouted Β· 11 labels movedhover a connector to outline the elements it joins
addedSolarPowerPlant – (not in this model)
addedSolarPowerPlant – SolarGeneratingUnit
addedWindPowerPlant – (not in this model)
addedWindPowerPlant – WindGeneratingUnit
rerouted(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – RotatingMachine
labels movedRotatingMachine – (not in this model)
β–Άβ–¦Thermali
Diagram notes
This diagram shows all classes included in the Thermal package as well as the key external classes that have associations with Thermal classes.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{93E625AE-B174-4d96-B127-8B8086E6BE1F}
Diagram notes
This diagram shows all classes included in the Thermal package as well as the key external classes that have associations with Thermal classes.
β–¦Diagram
changed
Baseline
Thermal (baseline)
Destination
Thermal (destination)
Package 'Generation' has no changes to the 1 diagrams it contains.
β–ΆEquivalentsi
Package notes
The equivalents package models equivalent networks.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{32F75AB7-7839-4933-BE8C-F162A464FE41}
Package notes
The equivalents package models equivalent networks.
Package 'Equivalents' has no changes to the 5 classes it contains.
Changed diagrams (1)
β–Άβ–¦Maini
Diagram notes
Shows model for equivalent networks.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{15613B15-ECE0-47f2-B5D5-CBA4AA111746}
Diagram notes
Shows model for equivalent networks.
β–¦Diagram
changed
Baseline
Main (baseline)
Destination
Main (destination)
β–ΆMeasi
Package notes
Contains entities that describe dynamic measurement data exchanged between applications.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{6B58A5C3-5CC1-4320-A9D3-2CABB8F9399E}
Package notes
Contains entities that describe dynamic measurement data exchanged between applications.
Package 'Meas' has no changes to the 29 classes it contains.
Changed diagrams (1)
β–Άβ–¦MeasurementInheritancei
Diagram notes
This diagram shows the measurement classes inheritance.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{5DF6F48B-1076-4edf-9F46-0132E1D9A930}
Diagram notes
This diagram shows the measurement classes inheritance.
β–¦Diagram
changed
Baseline
MeasurementInheritance (baseline)
Destination
MeasurementInheritance (destination)
β–ΆDiagramLayouti
Package notes
This package describes diagram layout. This describes how objects are arranged in a coordinate system rather than how they are rendered.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{BD6471E7-9929-4251-A731-BB65A6ABD2BF}
Package notes
This package describes diagram layout. This describes how objects are arranged in a coordinate system rather than how they are rendered.
Package 'DiagramLayout' has no changes to the 9 classes it contains.
Changed diagrams (1)
β–Άβ–¦DiagramLayouti
Diagram notes
Shows model for diagram layout.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{99E05246-80CF-4712-8EDF-605446BBFADE}
Diagram notes
Shows model for diagram layout.
β–¦Diagram
changed
Baseline
DiagramLayout (baseline)
Destination
DiagramLayout (destination)
β–ΆOperationalLimitsi
Package notes
This package models a specification of limits associated with equipment and other operational entities.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{CCAAF4EA-4C50-4438-86F9-63852950B3CA}
Package notes
This package models a specification of limits associated with equipment and other operational entities.
Moved classes (1)
β–Άβš™LimitKindΒ«enumeration, EuropeanΒ»i
Class notes
Limit kinds.
Class metadata β€” changes
BaselineDestination
ParentPackageExtEuOperationalLimitsOperationalLimits
Stereotypeenumerationenumeration, European
Tagged values β€” changes
BaselineDestination
no changes
MOVEDfrom ExtEuOperationalLimits{C6901289-57C7-41a3-AF87-9AA5E788E1CF}
Class notes
Limit kinds.
β–€Metadata
BaselineDestination
ParentPackageExtEuOperationalLimitsOperationalLimits
Stereotypeenumerationenumeration, European
Class 'LimitKind' has no other changes. The shows its notes and every changed property.
Changed classes (1)
β–Άβš™OperationalLimitTypei
Class notes
The operational meaning of a category of limits.
Class metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
CHANGED{B5E14C75-6C8D-4e7e-9FAF-D49F3BE177B9}
Class notes
The operational meaning of a category of limits.
≑Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kindi{A276A275-3642-42f7-BFD3-DDE024D07D96}show detailsdid not existLimitKind [0..1]Types of limits defined in the ENTSO-E Operational Handbook Policy 3.
Attribute notes
Types of limits defined in the ENTSO-E Operational Handbook Policy 3.
Attribute metadata β€” changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
Namekind
Scale0
Scopepublic
Staticfalse
StereotypeEuropean
TypeLimitKind
UpperBound1
Tagged values β€” changes
BaselineDestination
none
⇄Links
BaselineOperationalLimitType β†’ ExtEuOperationalLimitType
β†’
Destinationremoved from model
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOperationalLimitType
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExtEuOperationalLimitType
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed diagrams (2)
β–Άβ–¦BranchGroupi
Diagram notes
This diagram shows the model for monitoring combined flows on groups of branches.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{DE2F00E8-B731-43ce-B01C-7267ED3D9F4E}
Diagram notes
This diagram shows the model for monitoring combined flows on groups of branches.
β–¦Diagram
changed
Baseline
BranchGroup (baseline)
Destination
BranchGroup (destination)
β–Άβ–¦OperationalLimitsi
Diagram notes
This diagram shows operational limits as they tie back into the core model.
Diagram metadata β€” changes
BaselineDestination
ModifiedDate2023-10-08 07:55:322023-10-24 06:10:48
CHANGED{6B0E5843-FA70-4495-BB16-CD2B0CAA01B5}
Diagram notes
This diagram shows operational limits as they tie back into the core model.
β–€Metadata
BaselineDestination
ModifiedDate2023-10-08 07:55:322023-10-24 06:10:48
β–¦Diagram
addedchanged
Baseline
OperationalLimits (baseline)
Destination
OperationalLimits (destination)
β–ΆControlAreai
Package notes
The ControlArea package models area specifications which can be used for a variety of purposes. The package as a whole models potentially overlapping control area specifications for the purpose of actual generation control, load forecast area load capture, or powerflow based analysis.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{3A4198A2-F8DC-4ff1-B669-3064688AF4DD}
Package notes
The ControlArea package models area specifications which can be used for a variety of purposes. The package as a whole models potentially overlapping control area specifications for the purpose of actual generation control, load forecast area load capture, or powerflow based analysis.
Package 'ControlArea' has no changes to the 7 classes it contains.
Changed diagrams (1)
β–Άβ–¦ControlAreaInheritancei
Diagram notes
Shows the inheritance of classes in this package.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{AA2D75EA-1B1C-41b5-8C61-999912681F91}
Diagram notes
Shows the inheritance of classes in this package.
β–¦Diagram
changed
Baseline
ControlAreaInheritance (baseline)
Destination
ControlAreaInheritance (destination)
β–ΆContingencyi
Package notes
Contingencies to be studied.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{5AFF4730-5CFE-48e6-961A-077143DE2082}
Package notes
Contingencies to be studied.
Package 'Contingency' has no changes to the 4 classes it contains.
Changed diagrams (1)
β–Άβ–¦Contingencyi
Diagram notes
This diagram shows contingency model inheritance and associations.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{F06848B5-DB6D-4a40-91C8-00E7BC6F1823}
Diagram notes
This diagram shows contingency model inheritance and associations.
β–¦Diagram
changed
Baseline
Contingency (baseline)
Destination
Contingency (destination)
β–ΆProtectioni
Package notes
An extension to the Core and Wires packages that models information for protection equipment such as relays. These entities are used within training simulators and distribution network fault location applications.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{3F02E213-ECF8-4f14-9AD5-D4A252FE300A}
Package notes
An extension to the Core and Wires packages that models information for protection equipment such as relays. These entities are used within training simulators and distribution network fault location applications.
Package 'Protection' has no changes to the 4 classes it contains.
Changed diagrams (1)
β–Άβ–¦Maini
Diagram notes
This diagram shows all classes included in the Protection package as well as the key external classes that have associations with Protection classes.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{9AF2AFF5-A5C5-487d-BE22-9DADEDA9929E}
Diagram notes
This diagram shows all classes included in the Protection package as well as the key external classes that have associations with Protection classes.
β–¦Diagram
changed
Baseline
Main (baseline)
Destination
Main (destination)
β–ΆSCADAi
Package notes
Contains entities to model information used by Supervisory Control and Data Acquisition (SCADA) applications. Supervisory control supports operator control of equipment, such as opening or closing a breaker. Data acquisition gathers telemetered data from various sources. The subtypes of the Telemetry entity deliberately match the UCA and IEC 61850 definitions. This package also supports alarm presentation but it is not expected to be used by other applications.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{C397A471-682D-4757-89C3-C65DCE1842A7}
Package notes
Contains entities to model information used by Supervisory Control and Data Acquisition (SCADA) applications. Supervisory control supports operator control of equipment, such as opening or closing a breaker. Data acquisition gathers telemetered data from various sources. The subtypes of the Telemetry entity deliberately match the UCA and IEC 61850 definitions. This package also supports alarm presentation but it is not expected to be used by other applications.
Package 'SCADA' has no changes to the 7 classes it contains.
Changed diagrams (1)
β–Άβ–¦Maini
Diagram notes
This diagram shows all classes included in the SCADA package as well as the key external classes that have associations with SCADA classes.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{DCCD95DF-1D4D-4a31-ADC9-82410B121566}
Diagram notes
This diagram shows all classes included in the SCADA package as well as the key external classes that have associations with SCADA classes.
β–¦Diagram
changed
Baseline
Main (baseline)
Destination
Main (destination)
β–ΆPart303i
Package notes
Part of the canonical CIM published as IEC 61970-303.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{097BFA4A-EAE9-4618-B4D1-896C3B3BB77D}
Package notes
Part of the canonical CIM published as IEC 61970-303.
β–ΆGenericDataSeti
Package notes
Contains classes used for generic dataset modelling.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{8FF85768-B48A-4be5-9113-0DD28B347634}
Package notes
Contains classes used for generic dataset modelling.
Package 'GenericDataSet' has no changes to the 10 classes it contains.
Changed diagrams (1)
β–Άβ–¦GenericDataSeti
Diagram notes
Shows the generic dataset core classes.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{A5A07B09-93CB-423d-8595-8653C21E725B}
Diagram notes
Shows the generic dataset core classes.
β–¦Diagram
changed
Baseline
GenericDataSet (baseline)
Destination
GenericDataSet (destination)
β–ΆDynamicsi
Package notes
The CIM dynamic model definitions reflect the most common IEEE or, in the case of wind models, IEC, representations of models as well as models included in some of the transient stability software widely used by utilities. These dynamic models are intended to ensure interoperability between different vendors’ software products currently in use by electric utility energy companies, utilities, Transmission System Operators (TSOs), Regional Transmission Organizations (RTOs), and Independent System Operators (ISOs). It is important to note that each vendor is free to select its own internal implementation of these models. Differences in vendor results, as long as they are within accepted engineering practice, caused by different internal representations, are acceptable. Unless explicitly stated otherwise, the following modelling conventions are followed: - limited integrators are of the non-windup type; - it shall be possible to enter a time constant of zero (where it makes sense). The information in the entire clause "Common Information Model Dynamics package" is reproduced from the UML with the permission of UCAIug.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{A71B9185-6D48-40f4-B618-485C08C4F269}
Package notes
The CIM dynamic model definitions reflect the most common IEEE or, in the case of wind models, IEC, representations of models as well as models included in some of the transient stability software widely used by utilities. These dynamic models are intended to ensure interoperability between different vendors’ software products currently in use by electric utility energy companies, utilities, Transmission System Operators (TSOs), Regional Transmission Organizations (RTOs), and Independent System Operators (ISOs). It is important to note that each vendor is free to select its own internal implementation of these models. Differences in vendor results, as long as they are within accepted engineering practice, caused by different internal representations, are acceptable. Unless explicitly stated otherwise, the following modelling conventions are followed: - limited integrators are of the non-windup type; - it shall be possible to enter a time constant of zero (where it makes sense). The information in the entire clause "Common Information Model Dynamics package" is reproduced from the UML with the permission of UCAIug.
β–ΆStandardModelsi
Package notes
This subclause contains standard dynamic model specifications grouped into packages by standard function block (type of equipment being modelled). In the CIM, standard dynamic models are expressed by means of a class named with the standard model name and attributes reflecting each of the parameters necessary to describe the behaviour of an instance of the standard model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{1BEB429C-BFD0-49c6-9556-AC7BA58C2202}
Package notes
This subclause contains standard dynamic model specifications grouped into packages by standard function block (type of equipment being modelled). In the CIM, standard dynamic models are expressed by means of a class named with the standard model name and attributes reflecting each of the parameters necessary to describe the behaviour of an instance of the standard model.
β–ΆSynchronousMachineDynamicsi
Package notes
For conventional power generating units (e.g., thermal, hydro, combustion turbine), a synchronous machine model represents the electrical characteristics of the generator and the mechanical characteristics of the turbine-generator rotational inertia. Large industrial motors or groups of similar motors can be represented by individual motor models which are represented as generators with negative active power in the static (power flow) data. The interconnection with the electrical network equations can differ among simulation tools. The tool only needs to know the synchronous machine to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{448F8675-D39C-4fe0-9450-2791AE603EFC}
Package notes
For conventional power generating units (e.g., thermal, hydro, combustion turbine), a synchronous machine model represents the electrical characteristics of the generator and the mechanical characteristics of the turbine-generator rotational inertia. Large industrial motors or groups of similar motors can be represented by individual motor models which are represented as generators with negative active power in the static (power flow) data. The interconnection with the electrical network equations can differ among simulation tools. The tool only needs to know the synchronous machine to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models.
Package 'SynchronousMachineDynamics' has no changes to the 8 classes it contains.
Changed diagrams (1)
β–Άβ–¦SynchronousMachineDynamicsi
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the synchronous machine dynamics model. An association between the SynchronousMachineDynamics class and the SynchronousMachine class provides a means for relating the dynamics model to the static model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{54E9C659-8B6C-4948-A2ED-1F2B84C0A17C}
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the synchronous machine dynamics model. An association between the SynchronousMachineDynamics class and the SynchronousMachine class provides a means for relating the dynamics model to the static model.
β–¦Diagram
changed
Baseline
SynchronousMachineDynamics (baseline)
Destination
SynchronousMachineDynamics (destination)
β–ΆAsynchronousMachineDynamicsi
Package notes
An asynchronous machine model represents a (induction) generator or motor with no external connection to the rotor windings, e.g. a squirrel-cage induction machine. The interconnection with the electrical network equations can differ among simulation tools. The program only needs to know the terminal to which this asynchronous machine is connected in order to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models. The asynchronous machine model is used to model wind generators type 1 and type 2. For these, normal practice is to include the rotor flux transients and neglect the stator flux transients.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{5D284657-A8B5-4b22-A1BE-60220021422B}
Package notes
An asynchronous machine model represents a (induction) generator or motor with no external connection to the rotor windings, e.g. a squirrel-cage induction machine. The interconnection with the electrical network equations can differ among simulation tools. The program only needs to know the terminal to which this asynchronous machine is connected in order to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models. The asynchronous machine model is used to model wind generators type 1 and type 2. For these, normal practice is to include the rotor flux transients and neglect the stator flux transients.
Package 'AsynchronousMachineDynamics' has no changes to the 3 classes it contains.
Changed diagrams (1)
β–Άβ–¦AsynchronousMachineDynamicsi
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the asynchronous machine dynamics model. An association between the AsynchronousMachineDynamics class and the AsynchronousMachine class provides a means for relating the dynamics model to the static model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{25AB5834-2B99-4846-9C8F-855D6A80D650}
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the asynchronous machine dynamics model. An association between the AsynchronousMachineDynamics class and the AsynchronousMachine class provides a means for relating the dynamics model to the static model.
β–¦Diagram
changed
Baseline
AsynchronousMachineDynamics (baseline)
Destination
AsynchronousMachineDynamics (destination)
β–ΆTurbineGovernorDynamicsi
Package notes
The turbine-governor model is linked to one or two synchronous generators and determines the shaft mechanical power (<i>Pm</i>) or torque (<i>Tm</i>) for the generator model. Unlike IEEE standard models for other function blocks, the three IEEE turbine-governor standard models (GovHydroIEEE0, GovHydroIEEE2, and GovSteamIEEE1) are documented in IEEE Transactions, not in IEEE standards. For that reason, diagrams are supplied for those models. A 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, provides updated information on a variety of models including IEEE, vendor and reliability authority models. Fully incorporating the results of that report into the CIM dynamics model is a future effort.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{40DA7439-D5DD-4608-85C0-87CF5444B24E}
Package notes
The turbine-governor model is linked to one or two synchronous generators and determines the shaft mechanical power (<i>Pm</i>) or torque (<i>Tm</i>) for the generator model. Unlike IEEE standard models for other function blocks, the three IEEE turbine-governor standard models (GovHydroIEEE0, GovHydroIEEE2, and GovSteamIEEE1) are documented in IEEE Transactions, not in IEEE standards. For that reason, diagrams are supplied for those models. A 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, provides updated information on a variety of models including IEEE, vendor and reliability authority models. Fully incorporating the results of that report into the CIM dynamics model is a future effort.
Package 'TurbineGovernorDynamics' has no changes to the 58 classes it contains.
Changed diagrams (3)
β–Άβ–¦GasTurbineGovernorDynamicsi
Diagram notes
This diagram shows dynamic standard model gaz turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{3639F204-9BE3-448b-A437-52099DA95456}
Diagram notes
This diagram shows dynamic standard model gaz turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
β–¦Diagram
changed
Baseline
GasTurbineGovernorDynamics (baseline)
Destination
GasTurbineGovernorDynamics (destination)
β–Άβ–¦HydroTurbineGovernorDynamicsi
Diagram notes
This diagram shows dynamic standard model hydro turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{5DD835FF-3AB1-450d-9050-A786FC349923}
Diagram notes
This diagram shows dynamic standard model hydro turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
β–¦Diagram
changed
Baseline
HydroTurbineGovernorDynamics (baseline)
Destination
HydroTurbineGovernorDynamics (destination)
β–Άβ–¦SteamTurbineGovernorDynamicsi
Diagram notes
This diagram shows dynamic standard model steam turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{D646BBA5-04C5-4745-9D16-606392088DF9}
Diagram notes
This diagram shows dynamic standard model steam turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
β–¦Diagram
changed
Baseline
SteamTurbineGovernorDynamics (baseline)
Destination
SteamTurbineGovernorDynamics (destination)
β–ΆTurbineLoadControllerDynamicsi
Package notes
A turbine load controller acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{F0E43C7F-6E03-4b93-B0AF-2111023CA155}
Package notes
A turbine load controller acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference.
Package 'TurbineLoadControllerDynamics' has no changes to the 2 classes it contains.
Changed diagrams (1)
β–Άβ–¦TurbineLoadControllerDynamicsi
Diagram notes
This diagram shows dynamic standard model turbine load controller classes and their inheritance from the TurbineLoadControllerDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{EA37FCB1-4727-4ecd-94F5-0C25650651A1}
Diagram notes
This diagram shows dynamic standard model turbine load controller classes and their inheritance from the TurbineLoadControllerDynamics class.
β–¦Diagram
changed
Baseline
TurbineLoadControllerDynamics (baseline)
Destination
TurbineLoadControllerDynamics (destination)
β–ΆMechanicalLoadDynamicsi
Package notes
A mechanical load represents the variation in a motor's shaft torque or power as a function of shaft speed.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{54ED4DD8-2593-43f5-9A32-43679D605D36}
Package notes
A mechanical load represents the variation in a motor's shaft torque or power as a function of shaft speed.
Package 'MechanicalLoadDynamics' has no changes to the 2 classes it contains.
Changed diagrams (1)
β–Άβ–¦MechanicalLoadDynamicsi
Diagram notes
This diagram shows dynamic standard model mechanical load classes and their inheritance from the MechanicalLoadDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{5653B8A5-52C9-401e-811E-69E155E17018}
Diagram notes
This diagram shows dynamic standard model mechanical load classes and their inheritance from the MechanicalLoadDynamics class.
β–¦Diagram
changed
Baseline
MechanicalLoadDynamics (baseline)
Destination
MechanicalLoadDynamics (destination)
β–ΆExcitationSystemDynamicsi
Package notes
The excitation system model provides the field voltage (<i>Efd</i>) for a synchronous machine model. It is linked to a specific generator (synchronous machine). The representation of all limits used by the models (not including IEEE standard models) shall comply with the representation defined in Annex E of IEEE 421.5-2005, unless specified differently in the documentation of the model. The parameters are different for each excitation system model; the same parameter name can have different meaning in different models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{829F67E7-F698-4aa7-95C2-13C616AB6B78}
Package notes
The excitation system model provides the field voltage (<i>Efd</i>) for a synchronous machine model. It is linked to a specific generator (synchronous machine). The representation of all limits used by the models (not including IEEE standard models) shall comply with the representation defined in Annex E of IEEE 421.5-2005, unless specified differently in the documentation of the model. The parameters are different for each excitation system model; the same parameter name can have different meaning in different models.
Package 'ExcitationSystemDynamics' has no changes to the 42 classes it contains.
Changed diagrams (1)
β–Άβ–¦ExcitationSystemDynamicsi
Diagram notes
This diagram shows dynamic standard model excitation system classes and their inheritance from the ExcitationSystemDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{6F433799-BA80-4d4a-ABD1-BD898279F311}
Diagram notes
This diagram shows dynamic standard model excitation system classes and their inheritance from the ExcitationSystemDynamics class.
β–¦Diagram
changed
Baseline
ExcitationSystemDynamics (baseline)
Destination
ExcitationSystemDynamics (destination)
β–ΆOverexcitationLimiterDynamicsi
Package notes
Overexcitation limiters (OELs) are also referred to as <i>maximum excitation limiters </i>and <i>field current limiters. </i>The possibility of voltage collapse in stressed power systems increases the importance of modelling these limiters in studies of system conditions that cause machines to operate at high levels of excitation for a sustained period, such as voltage collapse or system-islanding. Such events typically occur over a long time frame compared with transient or small-signal stability simulations.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{CB5C7172-23DD-4cc0-ACF3-557E0496AFCD}
Package notes
Overexcitation limiters (OELs) are also referred to as <i>maximum excitation limiters </i>and <i>field current limiters. </i>The possibility of voltage collapse in stressed power systems increases the importance of modelling these limiters in studies of system conditions that cause machines to operate at high levels of excitation for a sustained period, such as voltage collapse or system-islanding. Such events typically occur over a long time frame compared with transient or small-signal stability simulations.
Package 'OverexcitationLimiterDynamics' has no changes to the 10 classes it contains.
Changed diagrams (1)
β–Άβ–¦OverexcitationLimiterDynamicsi
Diagram notes
This diagram shows dynamic standard model overexcitation limiter classes and their inheritance from the OverexcitationLimiterDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{FC47C181-4791-474a-AB30-CF1D0E20F49F}
Diagram notes
This diagram shows dynamic standard model overexcitation limiter classes and their inheritance from the OverexcitationLimiterDynamics class.
β–¦Diagram
changed
Baseline
OverexcitationLimiterDynamics (baseline)
Destination
OverexcitationLimiterDynamics (destination)
β–ΆUnderexcitationLimiterDynamicsi
Package notes
Underexcitation limiters (UELs) act to boost excitation. The UEL typically senses either a combination of voltage and current of the synchronous machine or a combination of real and reactive power. Some UELs utilize a temperature or pressure recalibration feature, in which the UEL characteristic is shifted depending upon the generator cooling gas temperature or pressure.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{6601D8F5-D2D3-4743-A9D8-51CADC84A53A}
Package notes
Underexcitation limiters (UELs) act to boost excitation. The UEL typically senses either a combination of voltage and current of the synchronous machine or a combination of real and reactive power. Some UELs utilize a temperature or pressure recalibration feature, in which the UEL characteristic is shifted depending upon the generator cooling gas temperature or pressure.
Package 'UnderexcitationLimiterDynamics' has no changes to the 7 classes it contains.
Changed diagrams (1)
β–Άβ–¦UnderexcitationLimiterDynamicsi
Diagram notes
This diagram shows dynamic standard model underexcitation limiter classes and their inheritance from the UnderexcitationLimiterDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{02C1E27A-FA01-4b4b-B496-F6BEDA3C6717}
Diagram notes
This diagram shows dynamic standard model underexcitation limiter classes and their inheritance from the UnderexcitationLimiterDynamics class.
β–¦Diagram
changed
Baseline
UnderexcitationLimiterDynamics (baseline)
Destination
UnderexcitationLimiterDynamics (destination)
β–ΆPowerSystemStabilizerDynamicsi
Package notes
The power system stabilizer (PSS) model provides an input (<i>Vs</i>) to the excitation system model to improve damping of system oscillations. A variety of input signals can be used depending on the particular design.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{15788FE9-6C55-412c-8AB7-F3F1EB004BDF}
Package notes
The power system stabilizer (PSS) model provides an input (<i>Vs</i>) to the excitation system model to improve damping of system oscillations. A variety of input signals can be used depending on the particular design.
Package 'PowerSystemStabilizerDynamics' has no changes to the 26 classes it contains.
Changed diagrams (1)
β–Άβ–¦PowerSystemStabilizerDynamicsi
Diagram notes
This diagram shows dynamic standard model power system stabilizer classes and their inheritance from the PowerSystemStabilizerDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{38DA7CE6-AE51-4221-B943-C23D17DBDE6B}
Diagram notes
This diagram shows dynamic standard model power system stabilizer classes and their inheritance from the PowerSystemStabilizerDynamics class.
β–¦Diagram
changed
Baseline
PowerSystemStabilizerDynamics (baseline)
Destination
PowerSystemStabilizerDynamics (destination)
β–ΆDiscontinuousExcitationControlDynamicsi
Package notes
In certain system configurations, continuous excitation control with terminal voltage and power system stabilizing regulator input signals does not ensure that the potential of the excitation system for improving system stability is fully exploited. For these situations, discontinuous excitation control signals can be employed to enhance stability following large transient disturbances. <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 12 and IEEE 421.5-2016, 14.</font>
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{510FA576-60DA-4709-96D0-60C754D1875E}
Package notes
In certain system configurations, continuous excitation control with terminal voltage and power system stabilizing regulator input signals does not ensure that the potential of the excitation system for improving system stability is fully exploited. For these situations, discontinuous excitation control signals can be employed to enhance stability following large transient disturbances. <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 12 and IEEE 421.5-2016, 14.</font>
Package 'DiscontinuousExcitationControlDynamics' has no changes to the 4 classes it contains.
Changed diagrams (1)
β–Άβ–¦DiscontinuousExcitationControlDynamicsi
Diagram notes
This diagram shows dynamic standard model discontinuous excitation control classes and their inheritance from the DiscontinuousExcitationControlDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{93B7D510-DFD1-470f-A764-E40D53B3F93A}
Diagram notes
This diagram shows dynamic standard model discontinuous excitation control classes and their inheritance from the DiscontinuousExcitationControlDynamics class.
β–¦Diagram
changed
Baseline
DiscontinuousExcitationControlDynamics (baseline)
Destination
DiscontinuousExcitationControlDynamics (destination)
β–ΆPFVArControllerType1Dynamicsi
Package notes
<font color="#0f0f0f">Excitation systems for synchronous machines are sometimes supplied with an optional means of automatically adjusting generator output reactive power (VAr) or power factor (PF) to a user-specified value. This can be accomplished with either a reactive power or power factor controller or regulator. A reactive power or power factor controller is defined as a PF/VAr controller in IEEE 421.1 as β€œa control function that acts through the reference adjuster to modify the voltage regulator set point to maintain the synchronous machine steady-state power factor or reactive power at a predetermined value.”</font> The signal excitation limiter status should come from the excitation systems.<font color="#0f0f0f"> </font> <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11 and IEEE 421.5-2016, 13.</font>
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{DB4B66D7-C753-481b-9C15-D0753561B765}
Package notes
<font color="#0f0f0f">Excitation systems for synchronous machines are sometimes supplied with an optional means of automatically adjusting generator output reactive power (VAr) or power factor (PF) to a user-specified value. This can be accomplished with either a reactive power or power factor controller or regulator. A reactive power or power factor controller is defined as a PF/VAr controller in IEEE 421.1 as β€œa control function that acts through the reference adjuster to modify the voltage regulator set point to maintain the synchronous machine steady-state power factor or reactive power at a predetermined value.”</font> The signal excitation limiter status should come from the excitation systems.<font color="#0f0f0f"> </font> <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11 and IEEE 421.5-2016, 13.</font>
Package 'PFVArControllerType1Dynamics' has no changes to the 5 classes it contains.
Changed diagrams (1)
β–Άβ–¦PFVArControllerType1Dynamicsi
Diagram notes
This diagram shows dynamic standard model power factor or VAr controller type 1 classes and their inheritance from the PFVArControllerType1Dynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{E5E56E46-8B1A-43d6-88B0-4C85E096AD7B}
Diagram notes
This diagram shows dynamic standard model power factor or VAr controller type 1 classes and their inheritance from the PFVArControllerType1Dynamics class.
β–¦Diagram
changed
Baseline
PFVArControllerType1Dynamics (baseline)
Destination
PFVArControllerType1Dynamics (destination)
β–ΆPFVArControllerType2Dynamicsi
Package notes
<font color="#0f0f0f">A var/pf regulator is defined as β€œa synchronous machine regulator that functions to maintain the power factor or reactive component of power at a predetermined value.” </font> The signal excitation limiter status should come from the excitation systems <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11 and IEEE 421.5-2016, 13.</font> <font color="#0f0f0f"> </font>
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{9AF74EDB-FFF5-4083-A7D5-48644244A045}
Package notes
<font color="#0f0f0f">A var/pf regulator is defined as β€œa synchronous machine regulator that functions to maintain the power factor or reactive component of power at a predetermined value.” </font> The signal excitation limiter status should come from the excitation systems <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11 and IEEE 421.5-2016, 13.</font> <font color="#0f0f0f"> </font>
Package 'PFVArControllerType2Dynamics' has no changes to the 6 classes it contains.
Changed diagrams (1)
β–Άβ–¦PFVArControllerType2Dynamicsi
Diagram notes
This diagram shows dynamic standard model power factor or VAr controller type 2 classes and their inheritance from the PFVArControllerType2Dynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{99C16D20-6A74-4483-A25E-34444E865297}
Diagram notes
This diagram shows dynamic standard model power factor or VAr controller type 2 classes and their inheritance from the PFVArControllerType2Dynamics class.
β–¦Diagram
changed
Baseline
PFVArControllerType2Dynamics (baseline)
Destination
PFVArControllerType2Dynamics (destination)
β–ΆVoltageAdjusterDynamicsi
Package notes
<font color="#0f0f0f">A voltage adjuster is a reference adjuster that uses inputs from a reactive power or power factor controller to modify the voltage regulator set point to maintain the synchronous machine steady-state power factor or reactive power at a predetermined value. </font> <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11.</font>
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{35B78447-A031-4927-A915-5C69304A72D2}
Package notes
<font color="#0f0f0f">A voltage adjuster is a reference adjuster that uses inputs from a reactive power or power factor controller to modify the voltage regulator set point to maintain the synchronous machine steady-state power factor or reactive power at a predetermined value. </font> <font color="#0f0f0f">For additional information please refer to IEEE 421.5-2005, 11.</font>
Package 'VoltageAdjusterDynamics' has no changes to the 3 classes it contains.
Changed diagrams (1)
β–Άβ–¦VoltageAdjusterDynamicsi
Diagram notes
This diagram shows dynamic standard model voltage adjuster classes and their inheritance from the VoltageAdjusterDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{98EECFEA-7320-4d23-A006-FB39CEBEC0AE}
Diagram notes
This diagram shows dynamic standard model voltage adjuster classes and their inheritance from the VoltageAdjusterDynamics class.
β–¦Diagram
changed
Baseline
VoltageAdjusterDynamics (baseline)
Destination
VoltageAdjusterDynamics (destination)
β–ΆVoltageCompensatorDynamicsi
Package notes
<font color="#0f0f0f">Synchronous machine terminal voltage transducer and current compensator models</font> adjust the terminal voltage feedback to the excitation system by adding a quantity that is proportional to the terminal current of the generator. It is linked to a specific generator (synchronous machine). <font color="#0f0f0f">Several types of compensation are available on most excitation systems. Synchronous machine active and reactive current compensation are the most common. Either reactive droop compensation and/or line-drop compensation can be used, simulating an impedance drop and effectively regulating at some point other than the terminals of the machine. The impedance or range of adjustment and type of compensation should be specified for different types. </font> <font color="#0f0f0f">Care shall be taken to ensure that a consistent PU system is utilized for the compensator parameters and the synchronous machine current base.</font> <font color="#0f0f0f">For further information see IEEE 421.5-2005, 4 and IEEE 421.5-2016, 5.</font> <font color="#0f0f0f"> </font>
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{7FD04580-1444-4ea3-A69D-D2D00000A4A9}
Package notes
<font color="#0f0f0f">Synchronous machine terminal voltage transducer and current compensator models</font> adjust the terminal voltage feedback to the excitation system by adding a quantity that is proportional to the terminal current of the generator. It is linked to a specific generator (synchronous machine). <font color="#0f0f0f">Several types of compensation are available on most excitation systems. Synchronous machine active and reactive current compensation are the most common. Either reactive droop compensation and/or line-drop compensation can be used, simulating an impedance drop and effectively regulating at some point other than the terminals of the machine. The impedance or range of adjustment and type of compensation should be specified for different types. </font> <font color="#0f0f0f">Care shall be taken to ensure that a consistent PU system is utilized for the compensator parameters and the synchronous machine current base.</font> <font color="#0f0f0f">For further information see IEEE 421.5-2005, 4 and IEEE 421.5-2016, 5.</font> <font color="#0f0f0f"> </font>
Package 'VoltageCompensatorDynamics' has no changes to the 4 classes it contains.
Changed diagrams (1)
β–Άβ–¦VoltageCompensatorDynamicsi
Diagram notes
This diagram shows dynamic standard model voltage compensator classes and their inheritance from the VoltageCompensatorDynamics class.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{107B566B-D071-4cc9-B058-F986EB9B14D5}
Diagram notes
This diagram shows dynamic standard model voltage compensator classes and their inheritance from the VoltageCompensatorDynamics class.
β–¦Diagram
changed
Baseline
VoltageCompensatorDynamics (baseline)
Destination
VoltageCompensatorDynamics (destination)
β–ΆHVDCDynamicsi
Package notes
High voltage direct current (HVDC) models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{7C62349B-D355-4ba0-BE12-91068427292A}
Package notes
High voltage direct current (HVDC) models.
Package 'HVDCDynamics' has no changes to the 4 classes it contains.
Changed diagrams (1)
β–Άβ–¦HVDCDynamicsi
Diagram notes
This diagram shows the dynamics model classes related to modelling of the HVDC.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{CE7EEDFF-0F31-40bd-A1D7-85C44EC39CDE}
Diagram notes
This diagram shows the dynamics model classes related to modelling of the HVDC.
β–¦Diagram
changed
Baseline
HVDCDynamics (baseline)
Destination
HVDCDynamics (destination)
β–ΆStaticVarCompensatorDynamicsi
Package notes
Static var compensator (SVC) models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{97871C31-9D61-4b9b-A49A-F63A7DC2DBA5}
Package notes
Static var compensator (SVC) models.
Package 'StaticVarCompensatorDynamics' has no changes to the 6 classes it contains.
Changed diagrams (1)
β–Άβ–¦StaticVarCompensatorDynamicsi
Diagram notes
This diagram shows the dynamics model classes related to modelling of the static var compensator (SVC) models.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{94AF0B28-6DC7-475c-9559-0CAC69363500}
Diagram notes
This diagram shows the dynamics model classes related to modelling of the static var compensator (SVC) models.
β–¦Diagram
changed
Baseline
StaticVarCompensatorDynamics (baseline)
Destination
StaticVarCompensatorDynamics (destination)
β–ΆShuntCompensatorDynamicsi
Package notes
Shunt compensator dynamics models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{18A7B5F9-12C2-4073-A382-477CC64A3B54}
Package notes
Shunt compensator dynamics models.
Package 'ShuntCompensatorDynamics' has no changes to the 1 classes it contains.
Changed diagrams (1)
β–Άβ–¦ShuntCompensatorDynamicsi
Diagram notes
This diagram shows the dynamics model classes related to modelling of the shunt compensator models.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{45969194-3222-46b2-8857-D0136EDA95F6}
Diagram notes
This diagram shows the dynamics model classes related to modelling of the shunt compensator models.
β–¦Diagram
changed
Baseline
ShuntCompensatorDynamics (baseline)
Destination
ShuntCompensatorDynamics (destination)
β–ΆStatcomDynamicsi
Package notes
STATCOM models.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{5AD5A535-9FB0-44fb-A314-694B39EEE13C}
Package notes
STATCOM models.
Package 'StatcomDynamics' has no changes to the 2 classes it contains.
Changed diagrams (1)
β–Άβ–¦StatcomDynamicsi
Diagram notes
This diagram shows the dynamics model classes related to modelling of the STATCOM models.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{A998EE9B-CBD5-486f-AA2A-9D8C5A945295}
Diagram notes
This diagram shows the dynamics model classes related to modelling of the STATCOM models.
β–¦Diagram
changed
Baseline
StatcomDynamics (baseline)
Destination
StatcomDynamics (destination)
Package 'StandardModels' has no changes to the 2 classes it contains.
β–ΆSimulationResulti
Package notes
This clause contains classes needed to describe dynamics simulation settings and results.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{F46BFE09-1F7D-4908-90ED-4A9799CF92B0}
Package notes
This clause contains classes needed to describe dynamics simulation settings and results.
Package 'SimulationResult' has no changes to the 14 classes it contains.
Changed diagrams (1)
β–Άβ–¦SimulationResulti
Diagram notes
The diagram presents the classes used in the part of the model used to exchange dynamics simulation results.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{3B18EC92-2D46-4747-85A5-7D1957304C6D}
Diagram notes
The diagram presents the classes used in the part of the model used to exchange dynamics simulation results.
β–¦Diagram
changed
Baseline
SimulationResult (baseline)
Destination
SimulationResult (destination)
β–ΆInfGridi
Package notes
This package and its subpackages contain informative (unstable) elements of the model, expected to evolve a lot or to be removed, and not published as IEC document yet. Some portions of it will be reworked and moved to normative packages as the need arises, and some portions may be removed. It should not be used to generate any formal documentation as this is an informative portion of the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{D2DD87AA-AF0C-477c-8E65-69D543D76521}
Package notes
This package and its subpackages contain informative (unstable) elements of the model, expected to evolve a lot or to be removed, and not published as IEC document yet. Some portions of it will be reworked and moved to normative packages as the need arises, and some portions may be removed. It should not be used to generate any formal documentation as this is an informative portion of the model.
β–ΆInfENTSOEextensionsNetworkCodesi
Package notes
Extensions approved ny ENTSO-E on 10 May 2023 as part of the Network Codes related work, so called Network Codes extensions and profiles.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{56A4E199-F4A6-4a6f-8DB7-B1A9E475213B}
Package notes
Extensions approved ny ENTSO-E on 10 May 2023 as part of the Network Codes related work, so called Network Codes extensions and profiles.
β–ΆExtNetworkCodesi
Package notes
This package contains the extensions defined for the need of Network codes (NC) data exchanges.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{87163B9E-DAB8-4fef-AC8B-445DA4276796}
Package notes
This package contains the extensions defined for the need of Network codes (NC) data exchanges.
β–ΆExtGLSKsi
Package notes
This package contains the extensions related to the generation and load shift keys (GLSKs).
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{8B666B78-C9A2-4a77-9992-219AB8F4BE61}
Package notes
This package contains the extensions related to the generation and load shift keys (GLSKs).
Package 'ExtGLSKs' has no changes to the 13 classes it contains.
Changed diagrams (1)
β–Άβ–¦ExtScheduleResourcei
Diagram notes
The diagram contains classes related to schedule resource.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{F2F179F0-28B8-4cd3-A238-B5D41060CC31}
Diagram notes
The diagram contains classes related to schedule resource.
β–¦Diagram
changed
Baseline
ExtScheduleResource (baseline)
Destination
ExtScheduleResource (destination)
β–ΆExtObjectRegistryi
Package notes
This package contains the extensions related to the object registry.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{E32C1533-1D51-45d4-BC05-394688598E18}
Package notes
This package contains the extensions related to the object registry.
Package 'ExtObjectRegistry' has no changes to the 5 classes it contains.
Changed diagrams (1)
β–Άβ–¦ExtObjectRegistryi
Diagram notes
The diagram contains classes related to the object registry extension.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{2FD38458-3E6B-4dd3-88C4-F7140BF9626F}
Diagram notes
The diagram contains classes related to the object registry extension.
β–¦Diagram
changed
Baseline
ExtObjectRegistry (baseline)
Destination
ExtObjectRegistry (destination)
β–ΆExtSecurityAnalysisResulti
Package notes
This package contains the extensions related to the security analysis result.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{10A082E7-6028-40a1-B86D-E91804AA325E}
Package notes
This package contains the extensions related to the security analysis result.
Package 'ExtSecurityAnalysisResult' has no changes to the 3 classes it contains.
Changed diagrams (1)
β–Άβ–¦SecurityAnalysisResulti
Diagram notes
The diagram contains classes related to the security analysis result.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{7B1B2EDD-9E29-46ab-8E44-D94E226F6E83}
Diagram notes
The diagram contains classes related to the security analysis result.
β–¦Diagram
changed
Baseline
SecurityAnalysisResult (baseline)
Destination
SecurityAnalysisResult (destination)
β–ΆExtSecurityLimiti
Package notes
This package contains the extensions related to the security limits.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{D5B1C554-7297-4096-A498-67D5BCFCD026}
Package notes
This package contains the extensions related to the security limits.
Changed classes (1)
β–Άβš™ExtOperationalLimitTypeΒ«NCΒ»i
Class notes
European network codes extension to base CIM counterpart.
Class metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
CHANGED{823C1713-78A5-4e45-9DC6-E63D4C1B2E0E}
Class notes
European network codes extension to base CIM counterpart.
⇄Links
BaselineExtEuOperationalLimitType β†’ ExtOperationalLimitType
β†’
Destinationremoved from model
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExtEuOperationalLimitType
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExtOperationalLimitType
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed diagrams (4)
β–Άβ–¦ExtMinimumLimiti
Diagram notes
The diagram contains classes related to minimum limit.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{3845D0F0-D5D2-4cb5-8311-B6251887C087}
Diagram notes
The diagram contains classes related to minimum limit.
β–¦Diagram
removedchanged
Baseline
ExtMinimumLimit (baseline)
Destination
ExtMinimumLimit (destination)
Connectors 2 removedhover a connector to outline the elements it joins
removedExtEuOperationalLimitType – ExtOperationalLimitType
removedOperationalLimitType – ExtEuOperationalLimitType
β–Άβ–¦ExtTemporaryLimitsi
Diagram notes
The diagram contains classes related to temporary limits.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{7198BD02-C13C-4cfa-8417-62A2418A65B6}
Diagram notes
The diagram contains classes related to temporary limits.
β–¦Diagram
changed
Baseline
ExtTemporaryLimits (baseline)
Destination
ExtTemporaryLimits (destination)
β–Άβ–¦ExtThermalBehaviourLimiti
Diagram notes
The diagram contains classes related to thermal behaviour limit.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{0CE50D86-0120-42f8-8D55-CC7322B3BEC6}
Diagram notes
The diagram contains classes related to thermal behaviour limit.
β–¦Diagram
changed
Baseline
ExtThermalBehaviourLimit (baseline)
Destination
ExtThermalBehaviourLimit (destination)
β–Άβ–¦ExtVoltageAngleLimiti
Diagram notes
The diagram contains classes related to voltage angle limit.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{EC3BB6AF-E7CE-483b-97CE-DA22EBAAB0CF}
Diagram notes
The diagram contains classes related to voltage angle limit.
β–¦Diagram
changed
Baseline
ExtVoltageAngleLimit (baseline)
Destination
ExtVoltageAngleLimit (destination)
Package 'ExtNetworkCodes' has no changes to the 1 classes it contains.
Package 'InfENTSOEextensionsNetworkCodes' has no changes to the 1 diagrams it contains.
β–ΆInfProtectionControlExtentionsi
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{2C89C60F-B47F-4274-9533-82E5D4349AFB}
Package notes
No notes defined in the model.
β–ΆGridExtensioni
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{299D30EB-D99A-41ec-9C5F-93CCB43A3615}
Package notes
No notes defined in the model.
β–ΆBaseExtensioni
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{1C928263-078A-4d8f-988A-6CAC163F7B28}
Package notes
No notes defined in the model.
β–ΆProtectionExtensioni
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{8D4434D1-A5E0-41ba-867F-9F5367748F81}
Package notes
No notes defined in the model.
Package 'ProtectionExtension' has no changes to the 35 classes it contains.
Changed diagrams (1)
β–Άβ–¦ProtectionRelayFunctionInheritance2i
Diagram notes
No notes defined in the model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{AC6BF8BA-E146-42ff-B709-16F2054E8AFD}
Diagram notes
No notes defined in the model.
β–¦Diagram
changed
Baseline
ProtectionRelayFunctionInheritance2 (baseline)
Destination
ProtectionRelayFunctionInheritance2 (destination)
β–ΆDocExtIEC61970i
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
ParentPackageEuropeanExtensionsInfGrid
Tagged values β€” changes
BaselineDestination
no changes
MOVEDfrom EuropeanExtensions{87BF140B-6CF8-43f6-9C7B-B6DBDBA9C10E}
Package notes
No notes defined in the model.
Changed diagrams (1)
β–Άβ–¦EMFIPi
Diagram notes
No notes defined in the model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{A3923AC5-4D07-44b7-B262-CA1282ECB554}
Diagram notes
No notes defined in the model.
β–¦Diagram
changed
Baseline
EMFIP (baseline)
Destination
EMFIP (destination)
β–ΆInfPart303i
Package notes
No notes defined in the model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{500389E9-5C8C-40f4-9EB4-19613576509E}
Package notes
No notes defined in the model.
β–ΆNetworkModelProjectsi
Package notes
Defining meta-data for a change set in the functional Power System model.
Package metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
{0090ED2A-A4A9-40f2-B6AC-02BBFADFE48D}
Package notes
Defining meta-data for a change set in the functional Power System model.
Package 'NetworkModelProjects' has no changes to the 19 classes it contains.
Changed diagrams (2)
β–Άβ–¦InfPowerSystemProjectsPJMi
Diagram notes
No notes defined in the model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{AAA4A8EE-D7BF-41c1-8611-15C1D784E506}
Diagram notes
No notes defined in the model.
β–¦Diagram
changed
Baseline
InfPowerSystemProjectsPJM (baseline)
Destination
InfPowerSystemProjectsPJM (destination)
β–Άβ–¦PowerSystemProjectDiscussioni
Diagram notes
No notes defined in the model.
Diagram metadata β€” changes
BaselineDestination
no changes
CHANGED{4BA9AD4C-A0FC-4df6-B473-0BDF19FA1F70}
Diagram notes
No notes defined in the model.
β–¦Diagram
changed
Baseline
PowerSystemProjectDiscussion (baseline)
Destination
PowerSystemProjectDiscussion (destination)
Package 'InfGrid' has no changes to the 1 diagrams it contains.
Changed classes (1)
β–Άβš™GridCIMVersioni
Class notes
This is the release version number assigned to Grid part of the CIM model. It is a point-in-time snapshot of the state of the CIM UML model that reflects a formal release of the CIM. This release version is distinct from the unique version (e.g. http://ucaiug.org/CIM/Base/1.0) associated with each package in the UML.
Class metadata β€” changes
BaselineDestination
no changes
Tagged values β€” changes
BaselineDestination
no changes
CHANGED{990AB50C-5CF8-46d2-B5FF-887BBBD3346F}
Class notes
This is the release version number assigned to Grid part of the CIM model. It is a point-in-time snapshot of the state of the CIM UML model that reflects a formal release of the CIM. This release version is distinct from the unique version (e.g. http://ucaiug.org/CIM/Base/1.0) associated with each package in the UML.
≑Attributes
AttributeBaselineDestinationNotes (destination, redlined)
dateimetadata changed - hovermetadata changed{8DADB97F-283D-40c7-A25A-D75E4C0D8507}show detailsDate [0..1]Date [0..1]Form is YYYY-MM-DD for example for January 5, 2009 it is 2009-01-05.
Attribute notes
Form is YYYY-MM-DD for example for January 5, 2009 it is 2009-01-05.
Attribute metadata β€” changes
BaselineDestination
Default2023-10-082023-10-24
Tagged values β€” changes
BaselineDestination
no changes
versionimetadata changed - hovermetadata changed{B4E0B1B6-8794-406a-A4C6-CBB395E37A52}show detailsString [0..1]String [0..1]Form is XXvYY where XX is the major CIM release version and the YY is the minor version. For example 18v03.
Attribute notes
Form is XXvYY where XX is the major CIM release version and the YY is the minor version. For example 18v03.
Attribute metadata β€” changes
BaselineDestination
Default18v0718v08
Tagged values β€” changes
BaselineDestination
no changes
Package 'Grid' has no changes to the 1 diagrams it contains.