CIM Model Comparison ·IEC61970CIM18v01 baseline → IEC61970CIM18v02 destination
Scope: IEC61970 · compared 2026-11-04 11:44:01 · cim-compare 2.3.1
Print or save as PDFOpens your browser’s print dialog (or press Ctrl+P, ⌘P on a Mac).• To save a PDF, choose Save as PDF (or Microsoft Print to PDF) as the printer.• Choose Landscape if the browser doesn’t pick it.• Turn off Headers and footers for a cleaner page.• Leave Background graphics on so the change colours print.Wait for diagram images to load in large reports.
Packages13 added23 changed
Classes218 added20 moved107 changed
Diagrams20 added6 moved265 changed
Click a count to show only those itemsp
Added — only in destinationDeleted — only in baselineMoved — same GUID, different packageChanged — same GUID and package; properties or members differIdenticalPackage (unchanged itself)struckinserted — destination text with baseline wording struck (notes, role notes, role names, multiplicities); the shows the notes and every changed propertyBlue — a changed attribute type (the new type)
▶IEC61970i
Package notes
Top package for IEC 61970.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{21D32832-FF64-4213-B81C-55ACE35EEBFF}
Package notes
Top package for IEC 61970.
▶Basei
Package notes
Content of the base CIM published as IEC 61970-301.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{20A2C6D8-4765-466f-AD75-5E1B3CAF4E8D}
Package notes
Content of the base CIM published as IEC 61970-301.
▶Domaini
Package notes
The domain package defines primitive datatypes that are used by classes in other packages. Stereotypes are used to describe the datatypes. The following stereotypes are defined: <<enumeration>> A list of permissible constant values. <<Primitive>> The most basic data types used to compose all other data types. <<CIMDatatype>> A datatype that contains a value attribute, an optional unit of measure and a unit multiplier. The unit and multiplier may be specified as a static variable initialized to the allowed value. <<Compound>> A composite of Primitive, enumeration, CIMDatatype or other Compound classes, as long as the Compound classes do not recurse. For all datatypes both positive and negative values are allowed unless stated otherwise for a particular datatype.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{0134E45C-F32A-4522-A725-E07B0AE4CB57}
Package notes
The domain package defines primitive datatypes that are used by classes in other packages. Stereotypes are used to describe the datatypes. The following stereotypes are defined: <<enumeration>> A list of permissible constant values. <<Primitive>> The most basic data types used to compose all other data types. <<CIMDatatype>> A datatype that contains a value attribute, an optional unit of measure and a unit multiplier. The unit and multiplier may be specified as a static variable initialized to the allowed value. <<Compound>> A composite of Primitive, enumeration, CIMDatatype or other Compound classes, as long as the Compound classes do not recurse. For all datatypes both positive and negative values are allowed unless stated otherwise for a particular datatype.
Package 'Domain' has no changes to the 74 classes it contains.
Changed diagrams (7)
▶▦BasicDatatypesi
Diagram notes
This diagram shows basic datatypes that are the basis for all other datatypes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-02-06 01:00:392022-06-10 11:46:45
CHANGED{DB3006EC-40EF-48f9-AE0B-54A4590505A4}
Diagram notes
This diagram shows basic datatypes that are the basis for all other datatypes.
▤Metadata
BaselineDestination
ModifiedDate2013-02-06 01:00:392022-06-10 11:46:45
▦Diagram
added
Baseline
BasicDatatypes (baseline)
Destination
BasicDatatypes (destination)
▶▦CombinedElectricalDatatypesi
Diagram notes
This diagram shows electrical datatypes that are combinations of other electrical datatypes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 18:12:552022-06-10 11:50:21
CHANGED{7338D2B9-5547-4eeb-9288-154038F19A4C}
Diagram notes
This diagram shows electrical datatypes that are combinations of other electrical datatypes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 18:12:552022-06-10 11:50:21
▦Diagram
added
Baseline
CombinedElectricalDatatypes (baseline)
Destination
CombinedElectricalDatatypes (destination)
▶▦ElectricityDatatypesi
Diagram notes
This diagram shows electricity related data types.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 18:18:092022-06-10 11:47:26
CHANGED{3CAD7AB5-5006-4340-9BF2-CB84AE4D3741}
Diagram notes
This diagram shows electricity related data types.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 18:18:092022-06-10 11:47:26
▦Diagram
added
Baseline
ElectricityDatatypes (baseline)
Destination
ElectricityDatatypes (destination)
▶▦EnumeratedUnitDatatypesi
Diagram notes
This diagram shows enumerated data types related to the SI unit system.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-20 13:28:192022-06-10 11:47:48
CHANGED{6FF3E444-BAE2-4338-BD38-5A4CBCC6F7AB}
Diagram notes
This diagram shows enumerated data types related to the SI unit system.
▤Metadata
BaselineDestination
ModifiedDate2019-03-20 13:28:192022-06-10 11:47:48
▦Diagram
added
Baseline
EnumeratedUnitDatatypes (baseline)
Destination
EnumeratedUnitDatatypes (destination)
▶▦GeneralDatatypesi
Diagram notes
This diagram shows general data types.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-04-05 08:10:092022-06-10 11:48:53
CHANGED{9478D0BE-F328-4c54-BE7D-DE95D8744E6B}
Diagram notes
This diagram shows general data types.
▤Metadata
BaselineDestination
ModifiedDate2019-04-05 08:10:092022-06-10 11:48:53
▦Diagram
addedmoved or resized
Baseline
GeneralDatatypes (baseline)
Destination
GeneralDatatypes (destination)
▶▦MonetaryDatatypesi
Diagram notes
This diagram shows monetary related data types.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-20 13:30:032022-06-10 11:49:28
CHANGED{B1E74B17-8731-44a6-8CBA-D14D923EFC11}
Diagram notes
This diagram shows monetary related data types.
▤Metadata
BaselineDestination
ModifiedDate2019-03-20 13:30:032022-06-10 11:49:28
▦Diagram
added
Baseline
MonetaryDatatypes (baseline)
Destination
MonetaryDatatypes (destination)
▶▦TimeDatatypesi
Diagram notes
This diagram shows time related data types.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-01-17 13:05:022022-06-10 11:49:47
CHANGED{83A53C50-B2DB-4b88-B1DB-E520708685BF}
Diagram notes
This diagram shows time related data types.
▤Metadata
BaselineDestination
ModifiedDate2013-01-17 13:05:022022-06-10 11:49:47
▦Diagram
added
Baseline
TimeDatatypes (baseline)
Destination
TimeDatatypes (destination)
▶Corei
Package notes
Contains the core PowerSystemResource and ConductingEquipment entities shared by all applications plus common collections of those entities. Not all applications require all the Core entities. This package does not depend on any other package except the Domain package, but most of the other packages have associations and generalizations that depend on it.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{6A503B72-6E15-4cd1-B92D-DDF6D14DBE29}
Package notes
Contains the core PowerSystemResource and ConductingEquipment entities shared by all applications plus common collections of those entities. Not all applications require all the Core entities. This package does not depend on any other package except the Domain package, but most of the other packages have associations and generalizations that depend on it.
Changed classes (9)
▶⚙ACDCTerminali
Class notes
An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{D37077B9-3B0C-4c16-8F5F-9A6F2C83A7F2}
Class notes
An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
⇄Links
Baselinedid not exist
→
DestinationSignalRecorder role SignalRecorder [0..*] → ACDCTerminal role RecordedSignalAt [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndSignalRecorder
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSignalRecorder
RoleNoteThe signal recorder where this signal is recorded.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndACDCTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleRecordedSignalAt
RoleNoteThe terminal at which the signal is recorded.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationSignalDescriptor role SignalDescriptor [0..*] → ACDCTerminal role ACDCTerminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndSignalDescriptor
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSignalDescriptor
RoleNoteThe signal descriptor that has a terminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndACDCTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleACDCTerminal
RoleNoteTh eterminal for this signal descriptor.
Scopepublic
TargetScopeinstance
▶⚙BasicIntervalSchedulei
Class notes
Schedule of values at points in time.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{848DEDB2-99A8-44ec-8319-F7629519D147}
Class notes
Schedule of values at points in time.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
value1Descriptioni{7CFA5236-E8D8-4c47-911F-E26EA6B70800}show detailsdid not existString [0..1]Description for value1.
Attribute notes
Description for value1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue1Description
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
value2Descriptioni{F9321376-FE48-4caa-9864-E5462E00B580}show detailsdid not existString [0..1]Description for value2.
Attribute notes
Description for value2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue2Description
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
value3Descriptioni{D72038B2-417E-4527-B26B-9F85D27A1396}show detailsdid not existString [0..1]Description for value3.
Attribute notes
Description for value3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue3Description
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
value3Multiplieri{015C5BE8-7726-40a8-AB4C-90AFFD2DDDFF}show detailsdid not existUnitMultiplier [0..1]Multiplier for value3.
Attribute notes
Multiplier for value3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue3Multiplier
Scale0
Scopepublic
Staticfalse
TypeUnitMultiplier
UpperBound1
Tagged values — changes
BaselineDestination
none
value3Uniti{5CE2FA2B-55DA-4a18-AE8A-F7C15EF88292}show detailsdid not existUnitSymbol [0..1]Value3 units of measure.
Attribute notes
Value3 units of measure.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue3Unit
Scale0
Scopepublic
Staticfalse
TypeUnitSymbol
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙ConductingEquipmenti
Class notes
The parts of the AC power system that are designed to carry current or that are conductively connected through terminals.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{7C5F19FB-5253-430c-8E53-BDCF7EBCE4C1}
Class notes
The parts of the AC power system that are designed to carry current or that are conductively connected through terminals.
⇄Links
Baselinedid not exist
→
DestinationRelayDynamics role RelayDynamics [0..*] → ConductingEquipment role ProtectedEquipment [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndRelayDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleRelayDynamics
RoleNoteRelay dynamics model used to describe dynamic behaviour of this protected equipment.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndConductingEquipment
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleProtectedEquipment
RoleNoteProtected equipment to which relay dynamics model applies.
Scopepublic
TargetScopeinstance
▶⚙Curvei
Class notes
A multi-purpose curve or functional relationship between an independent variable (X-axis) and dependent (Y-axis) variables.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{73A500A6-E7FF-4abe-8FDA-E68B4E60FF9F}
Class notes
A multi-purpose curve or functional relationship between an independent variable (X-axis) and dependent (Y-axis) variables.
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSimulationResultCharacteristic
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCurve
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙Equipmenti
Class notes
The parts of a power system that are physical devices, electronic or mechanical.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{F8DD8DAC-3545-4660-9CA5-794881CC6591}
Class notes
The parts of a power system that are physical devices, electronic or mechanical.
⇄Links
Baselinedid not exist
→
DestinationDetailedModelDynamics role DetailedModelDynamics [0..*] → Equipment role Equipment [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndDetailedModelDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDetailedModelDynamics
RoleNoteThe detailed model dynamics this models this equipment.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndEquipment
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleEquipment
RoleNoteThe equipment which behaviour this detailed model dynamics represents.
Scopepublic
TargetScopeinstance
▶⚙IdentifiedObjecti
Class notes
This is a root class to provide common identification for all classes needing identification and naming attributes.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{055C5806-E9D8-4a7a-9307-DAF7C31763C7}
Class notes
This is a root class to provide common identification for all classes needing identification and naming attributes.
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSimulationResult
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindProtectionIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndLoadElectronicWECC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWattVarSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContCurrLimIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContPType4aIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindMechIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndDERNameplateData
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndVoltageTripSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindPitchContPowerIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContRotorRIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSignalRecorder
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindGridMeasForControl
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSimulationEvents
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndDERNameplateDataApplied
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCommunicationIEC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContPType4bIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndServiceSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndLoadStaticWECC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndVoltVarSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContPType3IEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindPlantQControlIEC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndLoadMotorWECC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndConstantPowerFactorSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContQIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndPowerFlowSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndFrequencyDroopSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndDetailedModelDescriptor
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndFrequencyTripSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindAeroTwoDimIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndVoltWattSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndConstantReactivePowerSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindPlantPControlIEC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindPlantControlCommIEC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContQLimIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindGridMeasForProtection
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndLoadAirCoWECC
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndMomentaryCessationSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndClearSimulationEvent
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContPitchAngleIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndParameterEvent
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindAeroConstIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndDetailedModelTypeDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSimulationSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindDynamicsLookupTable2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndPowerLimitSettings
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindGenType3IEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindElectricalSystemGamma
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSignalConfiguration
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindRefFrameRotIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindGenType4IEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindAeroOneDimIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndWindContQPQULimIEC2
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndIdentifiedObject
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
DestinationParameterEvent role ParameterEvent [0..*] → IdentifiedObject role UsesParameterOf [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndParameterEvent
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleParameterEvent
RoleNoteThe parameter event that uses a parameter which belongs to this equipment, dynamics model or signal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndIdentifiedObject
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleUsesParameterOf
RoleNoteThe equipment, dynamics model or signal that is used to define the parameter event.
Scopepublic
TargetScopeinstance
▶⚙IrregularTimePointi
Class notes
TimePoints for a schedule where the time between the points varies.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{F3BCC51E-D829-45c1-BC79-9A6E463EFB0F}
Class notes
TimePoints for a schedule where the time between the points varies.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
value3i{246D1D86-3D84-4d87-9DDF-7AC94BA09E5D}show detailsdid not existFloat [0..1]The third value at the time. The meaning of the value is defined by the derived type of the associated schedule.
Attribute notes
The third value at the time. The meaning of the value is defined by the derived type of the associated schedule.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue3
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙RegularTimePointi
Class notes
Time point for a schedule where the time between the consecutive points is constant.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{8E858A31-A91C-4e9f-BEFA-6604EE4A4E30}
Class notes
Time point for a schedule where the time between the consecutive points is constant.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
value3i{798C2D43-3422-47b5-B75B-DA36C0E8A22A}show detailsdid not existFloat [0..1]The third value at the time. The meaning of the value is defined by the derived type of the associated schedule.
Attribute notes
The third value at the time. The meaning of the value is defined by the derived type of the associated schedule.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevalue3
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙Terminali
Class notes
An AC electrical connection point to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{1A0F8321-5E77-4d68-BE29-B36FA31549DC}
Class notes
An AC electrical connection point to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.
⇄Links
Baselinedid not exist
→
DestinationWeccWTGIBFFRA role WeccWTGIBFFRA [0..1] → Terminal role Terminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndWeccWTGIBFFRA
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleWeccWTGIBFFRA
RoleNoteThe WECC WTGIBFFRA model that has frequency measured at this Terminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleTerminal
RoleNoteThe Terminal where the frequency is measured.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationSVSMO4 role HasToTerminalSVSMO4 [0..1] → Terminal role ToTerminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndSVSMO4
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHasToTerminalSVSMO4
RoleNoteThe SVSMO4 model that has this ToTerminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleToTerminal
RoleNoteThe ToTerminal for this SVSMO4 model.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationSVSMO4 role HasFromTerminalSVSMO4 [0..1] → Terminal role FromTerminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndSVSMO4
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHasFromTerminalSVSMO4
RoleNoteThe SVSMO4 model that has this FromTerminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleFromTerminal
RoleNoteThe FromTerminal for this SVSMO4 model.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationRelayDynamics role RelayDynamics [0..*] → Terminal role MonitoredTerminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndRelayDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleRelayDynamics
RoleNoteRelay dynamics model that has monitored terminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleMonitoredTerminal
RoleNoteThe monitored terminal for this relay dynamics.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationWeccREPCC role WeccREPCC [0..1] → Terminal role Terminal [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndWeccREPCC
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleWeccREPCC
RoleNoteThe WECC REPCC model that has frequency measured at this Terminal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndTerminal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleTerminal
RoleNoteThe Terminal where the frequency is measured.
Scopepublic
TargetScopeinstance
Changed diagrams (7)
▶▦CurveSchedulei
Diagram notes
This diagram shows the common model for curves and time dependent schedules.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-06-30 13:55:522022-06-21 10:11:41
CHANGED{7DCA2E11-355A-47f2-9EF8-BEAEBD619E5D}
Diagram notes
This diagram shows the common model for curves and time dependent schedules.
▤Metadata
BaselineDestination
ModifiedDate2020-06-30 13:55:522022-06-21 10:11:41
▦Diagram
addedchangedmoved or resized
Baseline
CurveSchedule (baseline)
Destination
CurveSchedule (destination)
▶▦Datatypesi
Diagram notes
This diagram shows the data types specific to the Core package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-08-03 10:41:522022-06-10 11:52:25
CHANGED{22683F23-43FD-490f-8E85-34C3B3581EC8}
Diagram notes
This diagram shows the data types specific to the Core package.
▤Metadata
BaselineDestination
ModifiedDate2011-08-03 10:41:522022-06-10 11:52:25
▦Diagram
addedmoved or resized
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦FeederContainmenti
Diagram notes
This diagram shows feeder containment.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-06-16 14:29:422022-06-10 11:52:39
CHANGED{154626B0-2984-494a-B7D0-A92371728DC2}
Diagram notes
This diagram shows feeder containment.
▤Metadata
BaselineDestination
ModifiedDate2020-06-16 14:29:422022-06-10 11:52:39
▦Diagram
added
Baseline
FeederContainment (baseline)
Destination
FeederContainment (destination)
▶▦Maini
Diagram notes
This diagram shows the main classes needed for any application of the CIM for modelling transmission and generation systems.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-10-24 14:34:422022-06-10 11:51:10
CHANGED{F791662C-7488-4578-88E1-21352F9799CF}
Diagram notes
This diagram shows the main classes needed for any application of the CIM for modelling transmission and generation systems.
▤Metadata
BaselineDestination
ModifiedDate2019-10-24 14:34:422022-06-10 11:51:10
▦Diagram
added
Baseline
Main (baseline)
Destination
Main (destination)
▶▦Namesi
Diagram notes
This diagram shows classes used to assign names to identified objects.
Diagram metadata — changes
BaselineDestination
ModifiedDate2021-10-08 16:00:172022-06-10 11:51:33
CHANGED{E0451A91-94B6-4771-AA2F-2F1E5235FDE5}
Diagram notes
This diagram shows classes used to assign names to identified objects.
▤Metadata
BaselineDestination
ModifiedDate2021-10-08 16:00:172022-06-10 11:51:33
▦Diagram
addedchanged
Baseline
Names (baseline)
Destination
Names (destination)
Connectors 1 labels movedhover a connector to outline the elements it joins
labels movedNameType – Name
▶▦OperatingSharei
Diagram notes
This diagram shows the common model for operating share.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-02-02 15:16:462022-06-10 11:53:19
CHANGED{88289F74-ECDD-42e8-A693-6744785B1A0C}
Diagram notes
This diagram shows the common model for operating share.
▤Metadata
BaselineDestination
ModifiedDate2013-02-02 15:16:462022-06-10 11:53:19
▦Diagram
addedchanged
Baseline
OperatingShare (baseline)
Destination
OperatingShare (destination)
▶▦Reportingi
Diagram notes
This diagram shows the common model for ad-hoc reporting.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 09:54:022022-06-10 11:52:59
CHANGED{25B521B8-89DF-4043-A8D0-B37B0F772597}
Diagram notes
This diagram shows the common model for ad-hoc reporting.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 09:54:022022-06-10 11:52:59
▦Diagram
addedchanged
Baseline
Reporting (baseline)
Destination
Reporting (destination)
▶Wiresi
Package notes
An extension to the Core and Topology package that models information on the electrical characteristics of Transmission and Distribution networks. This package is used by network applications such as State Estimation, Load Flow and Optimal Power Flow.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{6C99E9CA-2035-4035-B77F-9217E17D86F4}
Package notes
An extension to the Core and Topology package that models information on the electrical characteristics of Transmission and Distribution networks. This package is used by network applications such as State Estimation, Load Flow and Optimal Power Flow.
Changed classes (5)
▶⚙AsynchronousMachinei
Class notes
A rotating machine whose shaft rotates asynchronously with the electrical field. Also known as an induction machine with no external connection to the rotor windings, e.g. squirrel-cage induction machine.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{EC5FCEFF-1274-4771-9D92-C0FF7A100AB8}
Class notes
A rotating machine whose shaft rotates asynchronously with the electrical field. Also known as an induction machine with no external connection to the rotor windings, e.g. squirrel-cage induction machine.
⇄Links
Baselinedid not exist
→
DestinationWeccDynamics role WeccDynamics [0..*] → AsynchronousMachine role AsynchronousMachine [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndWeccDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleWeccDynamics
RoleNoteWECC dynamics model associated with this asynchronous machine model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndAsynchronousMachine
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleAsynchronousMachine
RoleNoteAsynchronous machine model with which this WECC dynamics model is associated.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationDERDynamics role DERDynamics [0..1] → AsynchronousMachine role AsynchronousMachine [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndDERDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDERDynamics
RoleNoteDER dynamics model associated with this asynchronous machine model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndAsynchronousMachine
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleAsynchronousMachine
RoleNoteAsynchronous machine model with which this DER dynamics model is associated.
Scopepublic
TargetScopeinstance
▶⚙PowerElectronicsConnectioni
Class notes
A connection to the AC network for energy production or consumption that uses power electronics rather than rotating machines.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{AEF4A2AB-D126-4311-B299-CAB7D826A16E}
Class notes
A connection to the AC network for energy production or consumption that uses power electronics rather than rotating machines.
⇄Links
Baselinedid not exist
→
DestinationStatcomDynamics role StatcomDynamics [0..1] → PowerElectronicsConnection role PowerElectronicsConnection [1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndStatcomDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleStatcomDynamics
RoleNoteThe statcom dynamics model associated with this power electronics connection.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndPowerElectronicsConnection
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RolePowerElectronicsConnection
RoleNoteThe power electronics connection associated with this statcom dynamics model.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationDERDynamics role DERDynamics [0..1] → PowerElectronicsConnection role PowerElectronicsConnection [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndDERDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDERDynamics
RoleNoteDER dynamics model associated with this power electronics connection model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndPowerElectronicsConnection
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RolePowerElectronicsConnection
RoleNotePower electronics connection with which this DER dynamics model is associated.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationWeccDynamics role WeccDynamics [0..*] → PowerElectronicsConnection role PowerElectronicsConnection [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndWeccDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleWeccDynamics
RoleNoteWECC dynamics model associated with this Power electronics connection model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndPowerElectronicsConnection
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RolePowerElectronicsConnection
RoleNotePower electronics connection model with which this WECC dynamics model is associated.
Scopepublic
TargetScopeinstance
▶⚙ShuntCompensatori
Class notes
A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor. A negative value for bPerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device. Ground is implied.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{92B30569-5ED0-4fc0-B796-984D9BF75453}
Class notes
A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor. A negative value for bPerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device. Ground is implied.
⇄Links
Baselinedid not exist
→
DestinationShuntCompensatorDynamics role ShuntCompensatorDynamics [0..1] → ShuntCompensator role ShuntCompensator [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndShuntCompensatorDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleShuntCompensatorDynamics
RoleNoteShunt compensator dynamics model used to describe dynamic behaviour of this shunt compensator.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndShuntCompensator
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleShuntCompensator
RoleNoteShunt compensato to which shunt compensator dynamics model applies.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationStaticVarCompensatorSystemDynamics role StaticVarCompensatorSystemDynamics [0..1] → ShuntCompensator role ShuntCompensator [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndStaticVarCompensatorSystemDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleStaticVarCompensatorSystemDynamics
RoleNoteStatic Var Compensator system dynamics model used to describe dynamic behaviour of this Static Var Compensator system.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndShuntCompensator
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleShuntCompensator
RoleNoteShunt Compensator to which Static Var Compensator system dynamics model applies.
Scopepublic
TargetScopeinstance
▶⚙StaticVarCompensatori
Class notes
A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms. The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{B540EF99-8CE4-4da6-9E4D-D22E867F8BAE}
Class notes
A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms. The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.
⇄Links
BaselineStaticVarCompensatorDynamics role StaticVarCompensatorDynamics [0..1] → StaticVarCompensator role StaticVarCompensator [1]
→
DestinationStaticVarCompensatorDynamics role StaticVarCompensatorDynamics [0..1] → StaticVarCompensator role StaticVarCompensator [10..1]
Source end
no changes
Target end — StaticVarCompensator
BaselineDestination
Cardinality10..1
▶⚙SynchronousMachinei
Class notes
An electromechanical device that operates with shaft rotating synchronously with the network. It is a single machine operating either as a generator or synchronous condenser or pump.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{7862E21E-F054-4a33-949F-04B8B4690D49}
Class notes
An electromechanical device that operates with shaft rotating synchronously with the network. It is a single machine operating either as a generator or synchronous condenser or pump.
⇄Links
Baselinedid not exist
→
DestinationDERDynamics role DERDynamics [0..1] → SynchronousMachine role SynchronousMachine [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndDERDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDERDynamics
RoleNoteDER dynamics model associated with this synchronous machine model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndSynchronousMachine
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSynchronousMachine
RoleNoteSynchronous machine model with which this DER dynamics model is associated.
Scopepublic
TargetScopeinstance
Changed diagrams (16)
▶▦CutsAndJumpersi
Diagram notes
The diagram show the cuts and jumpers data model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 09:54:342022-06-10 11:54:39
CHANGED{56C8D23C-C73A-4bea-870E-5C920A3F1066}
Diagram notes
The diagram show the cuts and jumpers data model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 09:54:342022-06-10 11:54:39
▦Diagram
added
Baseline
CutsAndJumpers (baseline)
Destination
CutsAndJumpers (destination)
▶▦Datatypesi
Diagram notes
This diagram shows the data types specific to the Wires package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-20 16:09:542022-06-10 11:54:21
CHANGED{7F25DAE7-CB22-4224-AFEB-7F0BD8317D69}
Diagram notes
This diagram shows the data types specific to the Wires package.
▤Metadata
BaselineDestination
ModifiedDate2018-12-20 16:09:542022-06-10 11:54:21
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦EarthFaultCompensatori
Diagram notes
Shows earth fault compensating devices.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-12-08 11:35:092022-06-10 11:54:01
CHANGED{F1B3790B-5C3D-4307-8195-39D740D2D197}
Diagram notes
Shows earth fault compensating devices.
▤Metadata
BaselineDestination
ModifiedDate2011-12-08 11:35:092022-06-10 11:54:01
▦Diagram
added
Baseline
EarthFaultCompensator (baseline)
Destination
EarthFaultCompensator (destination)
▶▦InheritanceHierarchyi
Diagram notes
This diagram describes inheritance between classes in and related to the Wires package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-06-03 08:34:452022-06-10 11:55:15
CHANGED{D2B8C355-D454-4084-9966-12E8D7FF6875}
Diagram notes
This diagram describes inheritance between classes in and related to the Wires package.
▤Metadata
BaselineDestination
ModifiedDate2020-06-03 08:34:452022-06-10 11:55:15
▦Diagram
addedchanged
Baseline
InheritanceHierarchy (baseline)
Destination
InheritanceHierarchy (destination)
▶▦LineModeli
Diagram notes
This diagram shows all classes related to the transmission line model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-09-20 08:35:092022-06-10 11:55:35
CHANGED{1BE27117-9963-472a-99ED-71A231B36808}
Diagram notes
This diagram shows all classes related to the transmission line model.
▤Metadata
BaselineDestination
ModifiedDate2019-09-20 08:35:092022-06-10 11:55:35
▦Diagram
added
Baseline
LineModel (baseline)
Destination
LineModel (destination)
▶▦MutualCouplingi
Diagram notes
Shows mutual coupling models.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 09:59:092022-06-10 11:55:55
CHANGED{7CE6A094-D43D-4851-8A1F-D1B06FA7B538}
Diagram notes
Shows mutual coupling models.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 09:59:092022-06-10 11:55:55
▦Diagram
addedchanged
Baseline
MutualCoupling (baseline)
Destination
MutualCoupling (destination)
▶▦NamingHierarchyPart1i
Diagram notes
The diagram shows the upper part of the naming hierarchy. The hierarchy is a way to organize and name equipment. Hence it is tightly related to the IdentifiedObject and it's attributes. The Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-09-21 20:36:262022-06-10 11:57:14
CHANGED{422FB39E-1D47-45c4-8623-BADEED124BF6}
Diagram notes
The diagram shows the upper part of the naming hierarchy. The hierarchy is a way to organize and name equipment. Hence it is tightly related to the IdentifiedObject and it's attributes. The Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer.
▤Metadata
BaselineDestination
ModifiedDate2019-09-21 20:36:262022-06-10 11:57:14
▦Diagram
addedchanged
Baseline
NamingHierarchyPart1 (baseline)
Destination
NamingHierarchyPart1 (destination)
▶▦NamingHierarchyPart2i
Diagram notes
The diagram shows the lower part of the naming hierarchy. It shows how the Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer. For the subclasses of equipment container refer to part 1 of the diagram.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:04:582022-06-10 11:56:50
CHANGED{3A72A435-5BA5-4809-A5DC-560573D58582}
Diagram notes
The diagram shows the lower part of the naming hierarchy. It shows how the Equipment class is further specialized into many subtypes that are all contained by subclasses of the EquipmentContainer. For the subclasses of equipment container refer to part 1 of the diagram.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:04:582022-06-10 11:56:50
▦Diagram
addedchanged
Baseline
NamingHierarchyPart2 (baseline)
Destination
NamingHierarchyPart2 (destination)
Connectors 1 reroutedhover a connector to outline the elements it joins
rerouted(not in this model) – (not in this model)
▶▦RegulatingEquipmenti
Diagram notes
The diagram shows all classes related to equipment regulation and reactive power compensation.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-11-05 06:52:432022-06-10 12:00:00
CHANGED{F857266A-1599-4d8c-8AC8-29B416B63FA2}
Diagram notes
The diagram shows all classes related to equipment regulation and reactive power compensation.
▤Metadata
BaselineDestination
ModifiedDate2019-11-05 06:52:432022-06-10 12:00:00
▦Diagram
added
Baseline
RegulatingEquipment (baseline)
Destination
RegulatingEquipment (destination)
▶▦Schedulesi
Diagram notes
Shows schedules of wires model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:22:202022-06-10 12:00:00
CHANGED{18FA35BC-A253-4a57-A387-6D36B189A250}
Diagram notes
Shows schedules of wires model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:22:202022-06-10 12:00:00
▦Diagram
addedchanged
Baseline
Schedules (baseline)
Destination
Schedules (destination)
▶▦ShuntCompensatori
Diagram notes
Shows shunt compensator inheritance structure.
Diagram metadata — changes
BaselineDestination
ModifiedDate2021-08-06 12:44:192022-06-10 12:00:00
CHANGED{3CAA0009-F451-4e6d-BEDE-2AD7E67D3C35}
Diagram notes
Shows shunt compensator inheritance structure.
▤Metadata
BaselineDestination
ModifiedDate2021-08-06 12:44:192022-06-10 12:00:00
▦Diagram
added
Baseline
ShuntCompensator (baseline)
Destination
ShuntCompensator (destination)
▶▦SwitchingEquipmenti
Diagram notes
Shows switching equipment inheritance structure.
Diagram metadata — changes
BaselineDestination
ModifiedDate2021-08-06 12:44:482022-06-10 12:00:00
CHANGED{252E3FAB-DD51-437d-886F-5F699257FD4C}
Diagram notes
Shows switching equipment inheritance structure.
▤Metadata
BaselineDestination
ModifiedDate2021-08-06 12:44:482022-06-10 12:00:00
▦Diagram
added
Baseline
SwitchingEquipment (baseline)
Destination
SwitchingEquipment (destination)
▶▦TapChangeri
Diagram notes
This diagram shows all classes related to the transformer tap model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:24:202022-06-10 12:00:00
CHANGED{E6AB0688-D20A-4495-802A-28F4BC2E446D}
Diagram notes
This diagram shows all classes related to the transformer tap model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:24:202022-06-10 12:00:00
▦Diagram
addedmoved or resized
Baseline
TapChanger (baseline)
Destination
TapChanger (destination)
▶▦Transformeri
Diagram notes
This diagram shows classes related to the core transformer model, but does not show the tap changer details.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:42:232022-06-10 12:00:00
CHANGED{FA8E6B7F-EAD2-40df-956C-D26D5A54BFC7}
Diagram notes
This diagram shows classes related to the core transformer model, but does not show the tap changer details.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:42:232022-06-10 12:00:00
▦Diagram
added
Baseline
Transformer (baseline)
Destination
Transformer (destination)
▶▦VoltageControli
Diagram notes
This diagram shows all classes related to area voltage control.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-06-27 17:14:442022-06-10 12:00:00
CHANGED{6F7167AF-C91B-4203-9D17-9A5924B5ADB7}
Diagram notes
This diagram shows all classes related to area voltage control.
▤Metadata
BaselineDestination
ModifiedDate2011-06-27 17:14:442022-06-10 12:00:00
▦Diagram
added
Baseline
VoltageControl (baseline)
Destination
VoltageControl (destination)
▶▦WiresPhaseModeli
Diagram notes
Show the phase connection detail when modelling devices down to the phase components within a conducting equipment.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-09-20 08:47:402022-06-10 12:00:00
CHANGED{5957C2C3-427B-4740-952A-594EF9E660D0}
Diagram notes
Show the phase connection detail when modelling devices down to the phase components within a conducting equipment.
▤Metadata
BaselineDestination
ModifiedDate2019-09-20 08:47:402022-06-10 12:00:00
▦Diagram
addedmoved or resized
Baseline
WiresPhaseModel (baseline)
Destination
WiresPhaseModel (destination)
▶LoadModeli
Package notes
This package is responsible for modelling the energy consumers and the system load as curves and associated curve data. Special circumstances that may affect the load, such as seasons and day types, are also included here. This information is used by Load Forecasting and Load Management.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{427D9D64-CDA2-4070-AAC6-04A32F290872}
Package notes
This package is responsible for modelling the energy consumers and the system load as curves and associated curve data. Special circumstances that may affect the load, such as seasons and day types, are also included here. This information is used by Load Forecasting and Load Management.
Package 'LoadModel' has no changes to the 16 classes it contains.
Changed diagrams (1)
▶▦Maini
Diagram notes
This diagram shows all classes included in the LoadModel package as well as the key external classes that have associations with LoadModel classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:43:512022-06-10 12:00:30
CHANGED{E25D676B-3E4F-482f-B0D7-4B7A0ADFFFEB}
Diagram notes
This diagram shows all classes included in the LoadModel package as well as the key external classes that have associations with LoadModel classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:43:512022-06-10 12:00:30
▦Diagram
added
Baseline
Main (baseline)
Destination
Main (destination)
▶Generationi
Package notes
This package contains packages that have information for Unit Commitment and Economic Dispatch of hydro and thermal generating units, Load Forecasting, Automatic Generation Control, and unit modeling for Training Simulation.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{6B50A1FD-22E9-4abc-B0B7-F46BBD8B33AE}
Package notes
This package contains packages that have information for Unit Commitment and Economic Dispatch of hydro and thermal generating units, Load Forecasting, Automatic Generation Control, and unit modeling for Training Simulation.
▶GenerationTrainingSimulationi
Package notes
The GenerationTrainingSimululation package contains prime movers, such as turbines and boilers, which are needed for simulation and educational purposes.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{D3C36399-A1D6-4491-A975-06B94A5A1258}
Package notes
The GenerationTrainingSimululation package contains prime movers, such as turbines and boilers, which are needed for simulation and educational purposes.
Package 'GenerationTrainingSimulation' has no changes to the 15 classes it contains.
Changed diagrams (2)
▶▦Datatypesi
Diagram notes
This diagram shows the data types specific to the GenerationTrainingSimulation package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 17:42:432022-06-10 12:01:14
CHANGED{B89C6594-4092-41a0-B9FE-0A1CA2CAD148}
Diagram notes
This diagram shows the data types specific to the GenerationTrainingSimulation package.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 17:42:432022-06-10 12:01:14
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦Maini
Diagram notes
This diagram shows all classes included in the GenerationDynamics package as well as the key external classes that have associations with these classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-08-02 11:00:272022-06-10 12:01:42
CHANGED{3EEDCDC2-25C8-4c66-BC1B-A70CE13B5D22}
Diagram notes
This diagram shows all classes included in the GenerationDynamics package as well as the key external classes that have associations with these classes.
▤Metadata
BaselineDestination
ModifiedDate2011-08-02 11:00:272022-06-10 12:01:42
▦Diagram
added
Baseline
Main (baseline)
Destination
Main (destination)
▶Productioni
Package notes
The production package is responsible for classes which describe various kinds of generators. These classes also provide production costing information which is used to economically allocate demand among committed units and calculate reserve quantities.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{39719C4D-64F6-4704-8202-8CAEF5179709}
Package notes
The production package is responsible for classes which describe various kinds of generators. These classes also provide production costing information which is used to economically allocate demand among committed units and calculate reserve quantities.
Package 'Production' has no changes to the 49 classes it contains.
Changed diagrams (6)
▶▦Datatypesi
Diagram notes
This diagram show the data types specific to the Production package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 17:41:222022-06-10 12:06:11
CHANGED{E179110A-3FB3-43a0-93EB-EEB87DC510CE}
Diagram notes
This diagram show the data types specific to the Production package.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 17:41:222022-06-10 12:06:11
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦Hydroi
Diagram notes
This diagram shows all classes included in the Hydro package as well as the key external classes that have associations with Hydro classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 11:06:252022-06-10 12:02:33
CHANGED{DE303E99-315E-416c-906A-2195D7E5C62A}
Diagram notes
This diagram shows all classes included in the Hydro package as well as the key external classes that have associations with Hydro classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 11:06:252022-06-10 12:02:33
▦Diagram
added
Baseline
Hydro (baseline)
Destination
Hydro (destination)
▶▦Maini
Diagram notes
This diagram shows all classes included in the Production package that are needed by both Hydro and Thermal generation. It also shows key external classes that have associations with Production classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-29 16:00:002022-06-10 12:06:25
CHANGED{F9C40197-0210-4574-A263-DF81545A755B}
Diagram notes
This diagram shows all classes included in the Production package that are needed by both Hydro and Thermal generation. It also shows key external classes that have associations with Production classes.
▤Metadata
BaselineDestination
ModifiedDate2018-12-29 16:00:002022-06-10 12:06:25
▦Diagram
addedchanged
Baseline
Main (baseline)
Destination
Main (destination)
▶▦Nucleari
Diagram notes
This diagram shows nuclear generation inheritance.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-29 15:59:132022-06-10 12:06:40
CHANGED{60810DF7-9CDB-4150-81FB-BA2C6709E9D2}
Diagram notes
This diagram shows nuclear generation inheritance.
▤Metadata
BaselineDestination
ModifiedDate2018-12-29 15:59:132022-06-10 12:06:40
▦Diagram
added
Baseline
Nuclear (baseline)
Destination
Nuclear (destination)
▶▦PowerElectronicsi
Diagram notes
This diagram shows power electronics classes and inheritance.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-29 15:58:352022-06-10 12:07:01
CHANGED{A720762E-6E84-4af2-A047-9DA9F13F29AE}
Diagram notes
This diagram shows power electronics classes and inheritance.
▤Metadata
BaselineDestination
ModifiedDate2018-12-29 15:58:352022-06-10 12:07:01
▦Diagram
added
Baseline
PowerElectronics (baseline)
Destination
PowerElectronics (destination)
▶▦Thermali
Diagram notes
This diagram shows all classes included in the Thermal package as well as the key external classes that have associations with Thermal classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 11:08:002022-06-10 12:02:16
CHANGED{93E625AE-B174-4d96-B127-8B8086E6BE1F}
Diagram notes
This diagram shows all classes included in the Thermal package as well as the key external classes that have associations with Thermal classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 11:08:002022-06-10 12:02:16
▦Diagram
addedchanged
Baseline
Thermal (baseline)
Destination
Thermal (destination)
Changed diagrams (1)
▶▦Maini
Diagram notes
This diagram shows the main generation packages and their dependency relationships to other packages.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-08-02 10:27:372022-06-10 12:00:59
CHANGED{8A1AC91D-83FA-4e54-845A-7372236CF7B9}
Diagram notes
This diagram shows the main generation packages and their dependency relationships to other packages.
▤Metadata
BaselineDestination
ModifiedDate2011-08-02 10:27:372022-06-10 12:00:59
▦Diagram
addedmoved or resized
Baseline
Main (baseline)
Destination
Main (destination)
▶DCi
Package notes
This package contains model for direct current equipment and controls.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{6CA575E7-020B-40d8-B841-027BF8B51BE9}
Package notes
This package contains model for direct current equipment and controls.
▶DocDCi
Package notes
This package contains diagrams that will not be printed from the package context (within DC package), but you can and should use diagram placeholders in the 61970-301 template for documentation of examples and comments on modelling principles.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{EF6D1D39-2542-4779-9A28-92713646EFF1}
Package notes
This package contains diagrams that will not be printed from the package context (within DC package), but you can and should use diagram placeholders in the 61970-301 template for documentation of examples and comments on modelling principles.
Changed diagrams (5)
▶▦DCContainmentSymmetricalMonopolei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-03-05 14:23:202022-06-10 12:10:34
CHANGED{5984E6FC-9AEB-4880-8755-0864E37B183F}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2013-03-05 14:23:202022-06-10 12:10:34
▦Diagram
addedmoved or resized
Baseline
DCContainmentSymmetricalMonopole (baseline)
Destination
DCContainmentSymmetricalMonopole (destination)
▶▦DCSampleAsymmetricalMonopolei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-02-10 17:10:152022-06-10 12:11:39
CHANGED{8F6A8C77-3450-47f7-8D86-73F661F36E81}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2013-02-10 17:10:152022-06-10 12:11:39
▦Diagram
added
Baseline
DCSampleAsymmetricalMonopole (baseline)
Destination
DCSampleAsymmetricalMonopole (destination)
▶▦DCSampleBipolei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-03-05 13:11:472022-06-10 12:11:40
CHANGED{4112E113-03D6-48d6-931E-BCB784F3E923}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2013-03-05 13:11:472022-06-10 12:11:40
▦Diagram
added
Baseline
DCSampleBipole (baseline)
Destination
DCSampleBipole (destination)
▶▦DCSampleContainmentBipolei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-04-29 14:42:302022-06-10 12:10:34
CHANGED{0038B4B7-FEB6-4aa7-9A82-CB7E91177291}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2013-04-29 14:42:302022-06-10 12:10:34
▦Diagram
addedmoved or resized
Baseline
DCSampleContainmentBipole (baseline)
Destination
DCSampleContainmentBipole (destination)
▶▦DCSampleSymmetricalMonopolei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-09 08:14:532022-06-10 12:11:39
CHANGED{053C4907-6F2C-40b2-934C-BCBE394FCE85}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-09 08:14:532022-06-10 12:11:39
▦Diagram
added
Baseline
DCSampleSymmetricalMonopole (baseline)
Destination
DCSampleSymmetricalMonopole (destination)
Changed classes (1)
▶⚙DCEquipmentContaineri
Class notes
A modelling construct to provide a root class for containment of DC as well as AC equipment. The class differ from the EquipmentContainer for AC in that it may also contain DCNode(-s). Hence it can contain both AC and DC equipment.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{B7EB57A9-3AD6-40e2-9D5D-F391283E63B3}
Class notes
A modelling construct to provide a root class for containment of DC as well as AC equipment. The class differ from the EquipmentContainer for AC in that it may also contain DCNode(-s). Hence it can contain both AC and DC equipment.
⇄Links
Baselinedid not exist
→
DestinationHVDCInterconnectionDynamics role HVDCInterconnectionDynamics [0..1] → DCEquipmentContainer role DCEquipmentContainer [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndHVDCInterconnectionDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHVDCInterconnectionDynamics
RoleNoteHVDC interconnection dynamics model used to describe dynamic behaviour of this HVDC interconnection.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndDCEquipmentContainer
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDCEquipmentContainer
RoleNoteDC equipment container to which HVDC interconnection dynamics model applies.
Scopepublic
TargetScopeinstance
Changed diagrams (5)
▶▦ACDCConnectivityModeli
Diagram notes
This diagram shows connectivity and topology model for both AC and DC networks.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-06-16 14:29:422022-06-10 12:07:44
CHANGED{43531300-1039-4de2-880E-A73AFC65A581}
Diagram notes
This diagram shows connectivity and topology model for both AC and DC networks.
▤Metadata
BaselineDestination
ModifiedDate2020-06-16 14:29:422022-06-10 12:07:44
▦Diagram
added
Baseline
ACDCConnectivityModel (baseline)
Destination
ACDCConnectivityModel (destination)
▶▦ACDCConverteri
Diagram notes
This diagram shows classes used to model DC converters.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-06-30 13:55:522022-06-10 12:08:00
CHANGED{D8B07844-D3DD-4829-B42B-24F6109C6F13}
Diagram notes
This diagram shows classes used to model DC converters.
▤Metadata
BaselineDestination
ModifiedDate2020-06-30 13:55:522022-06-10 12:08:00
▦Diagram
added
Baseline
ACDCConverter (baseline)
Destination
ACDCConverter (destination)
▶▦DCContainmenti
Diagram notes
The diagram show the DC containment model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:13:222022-06-10 12:09:06
CHANGED{85E40024-3DB2-42ec-916D-B5108B3DE561}
Diagram notes
The diagram show the DC containment model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:13:222022-06-10 12:09:06
▦Diagram
added
Baseline
DCContainment (baseline)
Destination
DCContainment (destination)
▶▦DCEquipmenti
Diagram notes
The diagram show the DC equipment model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-29 11:58:592022-06-10 12:08:44
CHANGED{A060A742-BA22-4a1c-A24F-5862D1F35B87}
Diagram notes
The diagram show the DC equipment model.
▤Metadata
BaselineDestination
ModifiedDate2018-12-29 11:58:592022-06-10 12:08:44
▦Diagram
added
Baseline
DCEquipment (baseline)
Destination
DCEquipment (destination)
▶▦DCLineModeli
Diagram notes
The diagram show the DC line model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:14:122022-06-10 12:08:19
CHANGED{75A77CDA-F253-4dea-A6C1-DB74E8241BEE}
Diagram notes
The diagram show the DC line model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:14:122022-06-10 12:08:19
▦Diagram
added
Baseline
DCLineModel (baseline)
Destination
DCLineModel (destination)
▶Equivalentsi
Package notes
The equivalents package models equivalent networks.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{32F75AB7-7839-4933-BE8C-F162A464FE41}
Package notes
The equivalents package models equivalent networks.
Package 'Equivalents' has no changes to the 5 classes it contains.
Changed diagrams (1)
▶▦Maini
Diagram notes
Shows model for equivalent networks.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:31:052022-06-10 12:12:31
CHANGED{15613B15-ECE0-47f2-B5D5-CBA4AA111746}
Diagram notes
Shows model for equivalent networks.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:31:052022-06-10 12:12:31
▦Diagram
addedchanged
Baseline
Main (baseline)
Destination
Main (destination)
▶AuxiliaryEquipmenti
Package notes
Contains equipment which is not normal conducting equipment such as sensors, fault locators, and surge protectors. These devices do not define power carrying topological connections as conducting equipment, but are associated to terminals of other conducting equipment.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{FF7DBBED-8801-4db6-A94B-3AE5E6FFFE95}
Package notes
Contains equipment which is not normal conducting equipment such as sensors, fault locators, and surge protectors. These devices do not define power carrying topological connections as conducting equipment, but are associated to terminals of other conducting equipment.
Package 'AuxiliaryEquipment' has no changes to the 9 classes it contains.
Changed diagrams (1)
▶▦AuxiliaryEquipmenti
Diagram notes
Inheritance and associations for auxiliary equipment.
Diagram metadata — changes
BaselineDestination
ModifiedDate2020-09-02 12:57:482022-06-10 12:12:57
CHANGED{8B0885F9-C9C1-47ba-B331-E122DA4B4763}
Diagram notes
Inheritance and associations for auxiliary equipment.
▤Metadata
BaselineDestination
ModifiedDate2020-09-02 12:57:482022-06-10 12:12:57
▦Diagram
added
Baseline
AuxiliaryEquipment (baseline)
Destination
AuxiliaryEquipment (destination)
▶Measi
Package notes
Contains entities that describe dynamic measurement data exchanged between applications.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{6B58A5C3-5CC1-4320-A9D3-2CABB8F9399E}
Package notes
Contains entities that describe dynamic measurement data exchanged between applications.
Package 'Meas' has no changes to the 29 classes it contains.
Changed diagrams (5)
▶▦Controli
Diagram notes
This diagram shows all classes included in the Meas package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:32:112022-06-10 12:14:19
CHANGED{3289B12E-C4E6-473f-880A-706F56AB1751}
Diagram notes
This diagram shows all classes included in the Meas package.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:32:112022-06-10 12:14:19
▦Diagram
added
Baseline
Control (baseline)
Destination
Control (destination)
▶▦Datatypesi
Diagram notes
Shows datatypes for measurements.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 18:05:092022-06-10 12:14:01
CHANGED{488A00DE-1E4A-44ca-B9CB-01E231CCC6CA}
Diagram notes
Shows datatypes for measurements.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 18:05:092022-06-10 12:14:01
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦Measurementi
Diagram notes
This diagram shows classes central to the Measurement package and connections to some external classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:34:022022-06-10 12:13:51
CHANGED{8013CE5A-1E8B-43a7-8A3D-29DA0B40602A}
Diagram notes
This diagram shows classes central to the Measurement package and connections to some external classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:34:022022-06-10 12:13:51
▦Diagram
added
Baseline
Measurement (baseline)
Destination
Measurement (destination)
▶▦MeasurementInheritancei
Diagram notes
This diagram shows the measurement classes inheritance.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:39:342022-06-10 12:13:37
CHANGED{5DF6F48B-1076-4edf-9F46-0132E1D9A930}
Diagram notes
This diagram shows the measurement classes inheritance.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:39:342022-06-10 12:13:37
▦Diagram
addedchanged
Baseline
MeasurementInheritance (baseline)
Destination
MeasurementInheritance (destination)
▶▦Qualityi
Diagram notes
This diagram shows the details of the quality codes. The quality flags can be used also in other packages not only specific to MeasurementValues. A generalized Quality class is added and inherited into MeasurementValueQuality.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 19:03:412022-06-10 12:13:19
CHANGED{A84E42BC-B21D-4fa5-B7DC-006CE50BB19C}
Diagram notes
This diagram shows the details of the quality codes. The quality flags can be used also in other packages not only specific to MeasurementValues. A generalized Quality class is added and inherited into MeasurementValueQuality.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 19:03:412022-06-10 12:13:19
▦Diagram
added
Baseline
Quality (baseline)
Destination
Quality (destination)
▶Topologyi
Package notes
An extension to the Core Package that, in association with the Terminal class, models Connectivity, that is the physical definition of how equipment is connected together. In addition it models Topology, that is the logical definition of how equipment is connected via closed switches. The Topology definition is independent of the other electrical characteristics.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{E44AA599-D1DD-4d0c-8487-AE8BE9E6FEEB}
Package notes
An extension to the Core Package that, in association with the Terminal class, models Connectivity, that is the physical definition of how equipment is connected together. In addition it models Topology, that is the logical definition of how equipment is connected via closed switches. The Topology definition is independent of the other electrical characteristics.
Package 'Topology' has no changes to the 3 classes it contains.
Changed diagrams (2)
▶▦Maini
Diagram notes
This diagram shows all classes included in the Topology package as well as the key external classes that have associations with Topology classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2018-12-29 15:41:142022-06-10 12:15:05
CHANGED{BED90F47-24EF-4af0-A8CD-1DB3BE1E6A2E}
Diagram notes
This diagram shows all classes included in the Topology package as well as the key external classes that have associations with Topology classes.
▤Metadata
BaselineDestination
ModifiedDate2018-12-29 15:41:142022-06-10 12:15:05
▦Diagram
added
Baseline
Main (baseline)
Destination
Main (destination)
▶▦TopologyReportingi
Diagram notes
Shows topology reporting relationships.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-02-07 16:36:382022-06-10 12:14:39
CHANGED{92F35054-00D8-453d-9A7D-DED43346768E}
Diagram notes
Shows topology reporting relationships.
▤Metadata
BaselineDestination
ModifiedDate2013-02-07 16:36:382022-06-10 12:14:39
▦Diagram
added
Baseline
TopologyReporting (baseline)
Destination
TopologyReporting (destination)
Connectors 1 addedhover a connector to outline the elements it joins
addedBusNameMarker – TopologicalNode
▶DiagramLayouti
Package notes
This package describes diagram layout. This describes how objects are arranged in a coordinate system rather than how they are rendered.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{BD6471E7-9929-4251-A731-BB65A6ABD2BF}
Package notes
This package describes diagram layout. This describes how objects are arranged in a coordinate system rather than how they are rendered.
Package 'DiagramLayout' has no changes to the 9 classes it contains.
Changed diagrams (1)
▶▦DiagramLayouti
Diagram notes
Shows model for diagram layout.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-09 08:10:392022-06-10 12:15:30
CHANGED{99E05246-80CF-4712-8EDF-605446BBFADE}
Diagram notes
Shows model for diagram layout.
▤Metadata
BaselineDestination
ModifiedDate2019-03-09 08:10:392022-06-10 12:15:30
▦Diagram
addedchanged
Baseline
DiagramLayout (baseline)
Destination
DiagramLayout (destination)
Connectors 1 reroutedhover a connector to outline the elements it joins
reroutedDiagramObjectStyle – IdentifiedObject
▶OperationalLimitsi
Package notes
This package models a specification of limits associated with equipment and other operational entities.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{CCAAF4EA-4C50-4438-86F9-63852950B3CA}
Package notes
This package models a specification of limits associated with equipment and other operational entities.
Package 'OperationalLimits' has no changes to the 10 classes it contains.
Changed diagrams (2)
▶▦BranchGroupi
Diagram notes
This diagram shows the model for monitoring combined flows on groups of branches.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-11-02 20:26:142022-06-10 12:15:50
CHANGED{DE2F00E8-B731-43ce-B01C-7267ED3D9F4E}
Diagram notes
This diagram shows the model for monitoring combined flows on groups of branches.
▤Metadata
BaselineDestination
ModifiedDate2016-11-02 20:26:142022-06-10 12:15:50
▦Diagram
addedchanged
Baseline
BranchGroup (baseline)
Destination
BranchGroup (destination)
▶▦OperationalLimitsi
Diagram notes
This diagram shows operational limits as they tie back into the core model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:46:122022-06-10 12:16:16
CHANGED{6B0E5843-FA70-4495-BB16-CD2B0CAA01B5}
Diagram notes
This diagram shows operational limits as they tie back into the core model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:46:122022-06-10 12:16:16
▦Diagram
added
Baseline
OperationalLimits (baseline)
Destination
OperationalLimits (destination)
▶ControlAreai
Package notes
The ControlArea package models area specifications which can be used for a variety of purposes. The package as a whole models potentially overlapping control area specifications for the purpose of actual generation control, load forecast area load capture, or powerflow based analysis.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{3A4198A2-F8DC-4ff1-B669-3064688AF4DD}
Package notes
The ControlArea package models area specifications which can be used for a variety of purposes. The package as a whole models potentially overlapping control area specifications for the purpose of actual generation control, load forecast area load capture, or powerflow based analysis.
Package 'ControlArea' has no changes to the 6 classes it contains.
Changed diagrams (3)
▶▦ControlAreai
Diagram notes
This diagram shows control area specification and some related classes. The Terminal to AnalogValue linkages are shown for clarity in understanding the control area specification. The GeneratingUnit to Terminal linkages are also shown to illustrate how generation flows are specifically tied to the network.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-10-24 13:14:182022-06-10 12:16:37
CHANGED{EA9DC05C-2FC2-4b1f-BD10-55E43A2EEDD7}
Diagram notes
This diagram shows control area specification and some related classes. The Terminal to AnalogValue linkages are shown for clarity in understanding the control area specification. The GeneratingUnit to Terminal linkages are also shown to illustrate how generation flows are specifically tied to the network.
▤Metadata
BaselineDestination
ModifiedDate2019-10-24 13:14:182022-06-10 12:16:37
▦Diagram
added
Baseline
ControlArea (baseline)
Destination
ControlArea (destination)
▶▦ControlAreaInheritancei
Diagram notes
Shows the inheritance of classes in this package.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:51:402022-06-10 12:17:11
CHANGED{AA2D75EA-1B1C-41b5-8C61-999912681F91}
Diagram notes
Shows the inheritance of classes in this package.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:51:402022-06-10 12:17:11
▦Diagram
addedchanged
Baseline
ControlAreaInheritance (baseline)
Destination
ControlAreaInheritance (destination)
▶▦Datatypesi
Diagram notes
Shows datatypes for control areas.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:51:492022-06-10 12:16:54
CHANGED{66627334-C397-4f31-9D31-EC2B95860E81}
Diagram notes
Shows datatypes for control areas.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:51:492022-06-10 12:16:54
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶Contingencyi
Package notes
Contingencies to be studied.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{5AFF4730-5CFE-48e6-961A-077143DE2082}
Package notes
Contingencies to be studied.
Package 'Contingency' has no changes to the 4 classes it contains.
Changed diagrams (1)
▶▦Contingencyi
Diagram notes
This diagram shows contingency model inheritance and associations.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 14:38:222022-06-10 12:17:35
CHANGED{F06848B5-DB6D-4a40-91C8-00E7BC6F1823}
Diagram notes
This diagram shows contingency model inheritance and associations.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 14:38:222022-06-10 12:17:35
▦Diagram
addedchanged
Baseline
Contingency (baseline)
Destination
Contingency (destination)
▶StateVariablesi
Package notes
State variables for analysis solutions such as powerflow.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{968842F7-ED9B-4b20-A08E-C8ECAAC5DB25}
Package notes
State variables for analysis solutions such as powerflow.
Package 'StateVariables' has no changes to the 8 classes it contains.
Changed diagrams (1)
▶▦StateVariablesi
Diagram notes
The state solution variables as derived from base StateVariable class. Note that specialized state variables are associated with objects derived from IdentifiedObject, but StateVariable does not derive from IdentifiedObject.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 14:39:552022-06-10 12:17:55
CHANGED{98328D29-4518-4d82-93D9-EC1421E6E8BF}
Diagram notes
The state solution variables as derived from base StateVariable class. Note that specialized state variables are associated with objects derived from IdentifiedObject, but StateVariable does not derive from IdentifiedObject.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 14:39:552022-06-10 12:17:55
▦Diagram
added
Baseline
StateVariables (baseline)
Destination
StateVariables (destination)
Connectors 1 reroutedhover a connector to outline the elements it joins
reroutedSvSwitch – Switch
▶Protectioni
Package notes
An extension to the Core and Wires packages that models information for protection equipment such as relays. These entities are used within training simulators and distribution network fault location applications.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{3F02E213-ECF8-4f14-9AD5-D4A252FE300A}
Package notes
An extension to the Core and Wires packages that models information for protection equipment such as relays. These entities are used within training simulators and distribution network fault location applications.
Changed classes (1)
▶⚙ProtectionEquipmenti
Class notes
An electrical device designed to respond to input conditions in a prescribed manner and after specified conditions are met to cause contact operation or similar abrupt change in associated electric control circuits, or simply to display the detected condition. Protection equipment is associated with conducting equipment and usually operate circuit breakers.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{9EAE8A03-D411-432a-AC39-38ACEC6B1FAD}
Class notes
An electrical device designed to respond to input conditions in a prescribed manner and after specified conditions are met to cause contact operation or similar abrupt change in associated electric control circuits, or simply to display the detected condition. Protection equipment is associated with conducting equipment and usually operate circuit breakers.
⇄Links
Baselinedid not exist
→
DestinationRelayDynamics role RelayDynamics [0..*] → ProtectionEquipment role ProtectedEquipment [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndRelayDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleRelayDynamics
RoleNoteRelay dynamics model used to describe dynamic behaviour of this protected equipment.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndProtectionEquipment
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleProtectedEquipment
RoleNoteProtected equipment to which relay dynamics model applies.
Scopepublic
TargetScopeinstance
Changed diagrams (1)
▶▦Maini
Diagram notes
This diagram shows all classes included in the Protection package as well as the key external classes that have associations with Protection classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:40:482022-06-10 12:18:12
CHANGED{9AF2AFF5-A5C5-487d-BE22-9DADEDA9929E}
Diagram notes
This diagram shows all classes included in the Protection package as well as the key external classes that have associations with Protection classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:40:482022-06-10 12:18:12
▦Diagram
addedchanged
Baseline
Main (baseline)
Destination
Main (destination)
▶Faultsi
Package notes
The package describes faults that may happen to conducting equipment, e.g. tree falling on a power line.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{59BC9A2E-B8E4-4c5f-B1D8-2C6502296346}
Package notes
The package describes faults that may happen to conducting equipment, e.g. tree falling on a power line.
Changed classes (1)
▶⚙Faulti
Class notes
Abnormal condition causing current flow through conducting equipment, such as caused by equipment failure or short circuits from objects not typically modelled (for example, a tree falling on a line).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{73ABECF2-4B28-4c55-8665-0882A2C8BCA4}
Class notes
Abnormal condition causing current flow through conducting equipment, such as caused by equipment failure or short circuits from objects not typically modelled (for example, a tree falling on a line).
⇄Links
Baselinedid not exist
→
DestinationClearSimulationEvent role ClearSimulationEvent [0..*] → Fault role ClearedFaultEvent [0..1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndClearSimulationEvent
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleClearSimulationEvent
RoleNoteThe event that clears this fault event.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndFault
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleClearedFaultEvent
RoleNoteThe fault event that is cleared by a ClearSimulationEvent.
Scopepublic
TargetScopeinstance
Baselinedid not exist
→
DestinationSimulationEvents role SimulationEvents [0..1] → Fault role FaultEvent [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..1
ContainmentUnspecified
EndSimulationEvents
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSimulationEvents
RoleNoteThe simulation events to which this simulation fault event belongs to.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndFault
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleFaultEvent
RoleNoteThe simulation fault event that is part of this simulation.
Scopepublic
TargetScopeinstance
Changed diagrams (1)
▶▦Faultsi
Diagram notes
Classes used to model faults.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 09:46:442022-06-10 12:18:30
CHANGED{047849B4-4340-4e1e-8196-F13BD97C3A0B}
Diagram notes
Classes used to model faults.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 09:46:442022-06-10 12:18:30
▦Diagram
added
Baseline
Faults (baseline)
Destination
Faults (destination)
▶SCADAi
Package notes
Contains entities to model information used by Supervisory Control and Data Acquisition (SCADA) applications. Supervisory control supports operator control of equipment, such as opening or closing a breaker. Data acquisition gathers telemetered data from various sources. The subtypes of the Telemetry entity deliberately match the UCA and IEC 61850 definitions. This package also supports alarm presentation but it is not expected to be used by other applications.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{C397A471-682D-4757-89C3-C65DCE1842A7}
Package notes
Contains entities to model information used by Supervisory Control and Data Acquisition (SCADA) applications. Supervisory control supports operator control of equipment, such as opening or closing a breaker. Data acquisition gathers telemetered data from various sources. The subtypes of the Telemetry entity deliberately match the UCA and IEC 61850 definitions. This package also supports alarm presentation but it is not expected to be used by other applications.
Package 'SCADA' has no changes to the 7 classes it contains.
Changed diagrams (2)
▶▦Datatypesi
Diagram notes
Shows datatypes for SCADA model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-18 18:04:092022-06-10 12:18:57
CHANGED{0B3B79B7-3576-4779-86CD-25393DC86CDF}
Diagram notes
Shows datatypes for SCADA model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-18 18:04:092022-06-10 12:18:57
▦Diagram
added
Baseline
Datatypes (baseline)
Destination
Datatypes (destination)
▶▦Maini
Diagram notes
This diagram shows all classes included in the SCADA package as well as the key external classes that have associations with SCADA classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 13:40:112022-06-10 12:18:47
CHANGED{DCCD95DF-1D4D-4a31-ADC9-82410B121566}
Diagram notes
This diagram shows all classes included in the SCADA package as well as the key external classes that have associations with SCADA classes.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 13:40:112022-06-10 12:18:47
▦Diagram
addedchanged
Baseline
Main (baseline)
Destination
Main (destination)
▶ICCPConfigurationi
Package notes
This package models configuration of ICCP required for bilateral exchanges.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{423B82DE-E83D-40a8-A4C8-8EA08513C297}
Package notes
This package models configuration of ICCP required for bilateral exchanges.
▶DetailedDiagramsi
Package notes
No notes defined in the model.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{E563C801-A3FC-411f-A0D4-61F43A7C157B}
Package notes
No notes defined in the model.
Changed diagrams (1)
▶▦ICCPExamplei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-08 10:33:082022-06-10 12:19:54
CHANGED{4B060A5B-9830-40ac-B58C-9B4AA8F0D330}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2019-03-08 10:33:082022-06-10 12:19:54
▦Diagram
added
Baseline
ICCPExample (baseline)
Destination
ICCPExample (destination)
Package 'ICCPConfiguration' has no changes to the 19 classes it contains.
Changed diagrams (2)
▶▦GenericBilateralExchangei
Diagram notes
Classes used to model bilateral ICCP exchange.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-08 10:36:172022-06-10 12:19:33
CHANGED{0805DA3F-AF10-47ec-9559-F9FBA8892063}
Diagram notes
Classes used to model bilateral ICCP exchange.
▤Metadata
BaselineDestination
ModifiedDate2019-03-08 10:36:172022-06-10 12:19:33
▦Diagram
addedmoved or resized
Baseline
GenericBilateralExchange (baseline)
Destination
GenericBilateralExchange (destination)
▶▦ICCPi
Diagram notes
Classes used to model ICCP configuration.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-08 19:47:012022-06-10 12:19:17
CHANGED{BFA123BC-1A2D-467d-93BA-F9A00DF00B6D}
Diagram notes
Classes used to model ICCP configuration.
▤Metadata
BaselineDestination
ModifiedDate2019-03-08 19:47:012022-06-10 12:19:17
▦Diagram
added
Baseline
ICCP (baseline)
Destination
ICCP (destination)
▶DocBasei
Package notes
This package contains example documentation diagrams not intended to be documented in IEC61970-301 with the rest of the normative packages. The diagrams within this package are individually included in this document.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{9595963E-B478-4f81-8DE5-EBF73E630358}
Package notes
This package contains example documentation diagrams not intended to be documented in IEC61970-301 with the rest of the normative packages. The diagrams within this package are individually included in this document.
Changed diagrams (3)
▶▦DocumentationExampleAggregationi
Diagram notes
This shows an example of aggregation in UML. This diagram is only to support figures in the documentation.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 10:48:432022-06-10 12:21:53
CHANGED{B0A17FAD-A08E-4731-B421-5AE4F440638F}
Diagram notes
This shows an example of aggregation in UML. This diagram is only to support figures in the documentation.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 10:48:432022-06-10 12:21:53
▦Diagram
added
Baseline
DocumentationExampleAggregation (baseline)
Destination
DocumentationExampleAggregation (destination)
Connectors 1 labels movedhover a connector to outline the elements it joins
labels movedEquipmentContainer – Equipment
▶▦DocumentationExampleAssociationi
Diagram notes
This diagram is an example used for documentation purposes. It shows how a simple association and an aggregation association are expressed in UML diagrams.
Diagram metadata — changes
BaselineDestination
ModifiedDate2011-05-08 07:28:182022-06-10 12:22:08
CHANGED{C85F2447-5FC3-4c69-8C03-615271A4FD41}
Diagram notes
This diagram is an example used for documentation purposes. It shows how a simple association and an aggregation association are expressed in UML diagrams.
▤Metadata
BaselineDestination
ModifiedDate2011-05-08 07:28:182022-06-10 12:22:08
▦Diagram
added
Baseline
DocumentationExampleAssociation (baseline)
Destination
DocumentationExampleAssociation (destination)
▶▦DocumentationExampleInheritancei
Diagram notes
This shows an example of inheritance in UML. This diagram is only to support figures in the documentation.
Diagram metadata — changes
BaselineDestination
ModifiedDate2019-03-05 09:20:222022-06-10 12:21:41
CHANGED{8097D8D7-E05E-4885-982D-57E94DBA4BCD}
Diagram notes
This shows an example of inheritance in UML. This diagram is only to support figures in the documentation.
▤Metadata
BaselineDestination
ModifiedDate2019-03-05 09:20:222022-06-10 12:21:41
▦Diagram
added
Baseline
DocumentationExampleInheritance (baseline)
Destination
DocumentationExampleInheritance (destination)
▶Part303i
Package notes
Part of the canonical CIM published as IEC 61970-303.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{097BFA4A-EAE9-4618-B4D1-896C3B3BB77D}
Package notes
Part of the canonical CIM published as IEC 61970-303.
▶GenericDataSeti
Package notes
Contains classes used for generic dataset modelling.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{8FF85768-B48A-4be5-9113-0DD28B347634}
Package notes
Contains classes used for generic dataset modelling.
▶DetailedDiagramsi
Package notes
No notes defined in the model.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
{50A725FC-E4B0-4790-9B0A-6DE3A4F2D3C6}
Package notes
No notes defined in the model.
Changed diagrams (7)
▶▦ChangeAChangei
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:24:58
CHANGED{137CC452-D0AC-4f00-B1AB-57DD0AE3582A}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:24:58
▦Diagram
added
Baseline
ChangeAChange (baseline)
Destination
ChangeAChange (destination)
▶▦CreateLoadi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:24:35
CHANGED{F96AF6BC-505A-4b0a-8DC0-16713E35DCD2}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:24:35
▦Diagram
added
Baseline
CreateLoad (baseline)
Destination
CreateLoad (destination)
▶▦CreateLoadWithoutProxyi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2015-11-12 10:58:422022-06-10 12:24:16
CHANGED{17000BB1-85C0-4115-8C52-30457336238B}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2015-11-12 10:58:422022-06-10 12:24:16
▦Diagram
added
Baseline
CreateLoadWithoutProxy (baseline)
Destination
CreateLoadWithoutProxy (destination)
▶▦DeleteLoadi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:23:59
CHANGED{07A4F359-09C6-4293-99E1-24079C094D9B}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:23:59
▦Diagram
added
Baseline
DeleteLoad (baseline)
Destination
DeleteLoad (destination)
▶▦DeleteLoadWithoutProxyi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2015-11-12 10:58:402022-06-10 12:23:41
CHANGED{B951361B-B26C-421d-98B9-F275EF1EAC57}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2015-11-12 10:58:402022-06-10 12:23:41
▦Diagram
added
Baseline
DeleteLoadWithoutProxy (baseline)
Destination
DeleteLoadWithoutProxy (destination)
Connectors 2 labels movedhover a connector to outline the elements it joins
labels moved(not in this model) – (not in this model)
labels moved(not in this model) – (not in this model)
▶▦ModifyLoadi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:23:27
CHANGED{A956A6D7-6982-45d6-9C8E-C2C1578B022B}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2016-11-15 21:03:292022-06-10 12:23:27
▦Diagram
added
Baseline
ModifyLoad (baseline)
Destination
ModifyLoad (destination)
▶▦ModifyLoadWithoutProxyi
Diagram notes
No notes defined in the model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2015-11-12 10:58:352022-06-10 12:23:07
CHANGED{882D85EC-570E-4f7d-9185-D23BF263594D}
Diagram notes
No notes defined in the model.
▤Metadata
BaselineDestination
ModifiedDate2015-11-12 10:58:352022-06-10 12:23:07
▦Diagram
added
Baseline
ModifyLoadWithoutProxy (baseline)
Destination
ModifyLoadWithoutProxy (destination)
Package 'GenericDataSet' has no changes to the 10 classes it contains.
Changed diagrams (1)
▶▦GenericDataSeti
Diagram notes
Shows the generic dataset core classes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2021-09-29 10:41:052022-06-10 12:22:40
CHANGED{A5A07B09-93CB-423d-8595-8653C21E725B}
Diagram notes
Shows the generic dataset core classes.
▤Metadata
BaselineDestination
ModifiedDate2021-09-29 10:41:052022-06-10 12:22:40
▦Diagram
addedchanged
Baseline
GenericDataSet (baseline)
Destination
GenericDataSet (destination)
▶Dynamicsi
Package notes (destination, redlined)
The CIM dynamic model definitions reflect the most common IEEE or, in the case of wind models, IEC, representations of models as well as models included in some of the transient stability software widely used by utilities. These dynamic models are intended to ensure interoperability between different vendors’ software products currently in use by electric utility energy companies, utilities, Transmission System Operators (TSOs), Regional Transmission Organizations (RTOs), and Independent System Operators (ISOs). It is important to note that each vendor is free to select its own internal implementation of these models. Differences in vendor results, as long as they are within accepted engineering practice, caused by different internal representations, are acceptable. Unless explicitly stated otherwise, the following modelling conventions are followed: - limited integrators are of the non-windup type; - it shall be possible to enter a time constant of zero (where it makes sense). The information in this clause is reproduced from the UML with the permission of UCAIug.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/Dynamics/1.0
version(no tag)1.0.0
CHANGED{A71B9185-6D48-40f4-B618-485C08C4F269}
Package notes (destination, redlined)
The CIM dynamic model definitions reflect the most common IEEE or, in the case of wind models, IEC, representations of models as well as models included in some of the transient stability software widely used by utilities. These dynamic models are intended to ensure interoperability between different vendors’ software products currently in use by electric utility energy companies, utilities, Transmission System Operators (TSOs), Regional Transmission Organizations (RTOs), and Independent System Operators (ISOs). It is important to note that each vendor is free to select its own internal implementation of these models. Differences in vendor results, as long as they are within accepted engineering practice, caused by different internal representations, are acceptable. Unless explicitly stated otherwise, the following modelling conventions are followed: - limited integrators are of the non-windup type; - it shall be possible to enter a time constant of zero (where it makes sense). The information in this clause is reproduced from the UML with the permission of UCAIug.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/Dynamics/1.0
version(no tag)1.0.0
▶StandardInterconnectionsi
Package notes (destination, redlined)
This subclause describes the standard interconnections for various types of equipment. These interconnections are understood by the application programs and can be identified based on the presence of one of the key classes with a relationship to the static power flow model: SynchronousMachineDynamics, AsynchronousMachineDynamics, EnergyConsumerDynamics or WindTurbineType3or4Dynamics. The relationships between classes expressed in the interconnection diagrams are intended to support dynamic behaviour described by either standard models or user-defined models. In the interconnection diagrams, boxes which are black in colour represent function blocks whose functionality can be provided by one of many standard models or by a user-defined model. Blue boxes represent specific standard models. A dashed box means that the function block or specific standard model is optional.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/StandardInterconnections/1.0
version(no tag)1.0.0
CHANGED{9E32B79D-9C05-4fe4-9518-A32B1C67637A}
Package notes (destination, redlined)
This subclause describes the standard interconnections for various types of equipment. These interconnections are understood by the application programs and can be identified based on the presence of one of the key classes with a relationship to the static power flow model: SynchronousMachineDynamics, AsynchronousMachineDynamics, EnergyConsumerDynamics or WindTurbineType3or4Dynamics. The relationships between classes expressed in the interconnection diagrams are intended to support dynamic behaviour described by either standard models or user-defined models. In the interconnection diagrams, boxes which are black in colour represent function blocks whose functionality can be provided by one of many standard models or by a user-defined model. Blue boxes represent specific standard models. A dashed box means that the function block or specific standard model is optional.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/StandardInterconnections/1.0
version(no tag)1.0.0
▶WindModelsi
Package notes
Standard interconnections included in this package are according to IEC 61400-27-1:2015.
Package metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
IsLeaffalse
IsRootfalse
NameWindModels
ParentPackageStandardInterconnections
Phase1.0
Scopepublic
StatusProposed
TypePackage
Version1.0
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/WindModels/1.0
version(no tag)1.0.0
ADDED{6319640C-8A7E-4aae-A1DA-A6DB83723377}
Package notes
Standard interconnections included in this package are according to IEC 61400-27-1:2015.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/WindModels/1.0
version(no tag)1.0.0
Moved diagrams (6)
▶▦StandardInterconnectionWindTurbineType1Aand1Bi
Diagram notes
A dynamic model representing a type 1 wind turbine model uses asynchronous generators directly connected to the grid, i.e. without power converters. Most type 1 wind turbines have a soft-starter, but this is only active during start-up. There are two type 1 models: - type 1A: wind turbines with fixed pitch angle; - type 1B: wind turbines with under voltage ride-through pitch angle control. The two standard interconnections are shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.2.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-16 23:31:352022-03-18 21:37:41
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{66D6FDF4-9761-494b-B22B-14A931CF4EE3}
Diagram notes
A dynamic model representing a type 1 wind turbine model uses asynchronous generators directly connected to the grid, i.e. without power converters. Most type 1 wind turbines have a soft-starter, but this is only active during start-up. There are two type 1 models: - type 1A: wind turbines with fixed pitch angle; - type 1B: wind turbines with under voltage ride-through pitch angle control. The two standard interconnections are shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.2.
▤Metadata
BaselineDestination
ModifiedDate2017-06-16 23:31:352022-03-18 21:37:41
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
Diagram 'StandardInterconnectionWindTurbineType1Aand1B' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionWindTurbineType2i
Diagram notes
A dynamic model representing a type 2 wind generator and its related standard equipment models is associated with an asynchronous machine in the static (power flow) model and has the standard interconnection shown in the figure. The type 2 turbine is equipped with a variable rotor resistance (VRR) and therefore uses a variable rotor resistance asynchronous generator (VRRAG). Type 2 wind turbines are also normally equipped with blade angle control. Reference: IEC 61400-27-1:2015, 5.5.3.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-16 23:29:392022-03-18 21:37:53
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{4673C005-66DA-482a-A476-68CE5186585B}
Diagram notes
A dynamic model representing a type 2 wind generator and its related standard equipment models is associated with an asynchronous machine in the static (power flow) model and has the standard interconnection shown in the figure. The type 2 turbine is equipped with a variable rotor resistance (VRR) and therefore uses a variable rotor resistance asynchronous generator (VRRAG). Type 2 wind turbines are also normally equipped with blade angle control. Reference: IEC 61400-27-1:2015, 5.5.3.
▤Metadata
BaselineDestination
ModifiedDate2017-06-16 23:29:392022-03-18 21:37:53
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
Diagram 'StandardInterconnectionWindTurbineType2' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionWindTurbineType3i
Diagram notes
A dynamic model representing a type 3 wind turbine which uses a doubly fed asynchronous generator (DFAG), where the stator is directly connected to the grid and the rotor is connected through a back-to-back power converter. It has the standard interconnection shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.4.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-16 23:29:492022-03-18 21:38:07
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{A5B33598-C2FD-4873-84AE-58459663DA29}
Diagram notes
A dynamic model representing a type 3 wind turbine which uses a doubly fed asynchronous generator (DFAG), where the stator is directly connected to the grid and the rotor is connected through a back-to-back power converter. It has the standard interconnection shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.4.
▤Metadata
BaselineDestination
ModifiedDate2017-06-16 23:29:492022-03-18 21:38:07
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
Diagram 'StandardInterconnectionWindTurbineType3' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionWindTurbineType4Aand4Bi
Diagram notes
A dynamic model representing a type 4 wind turbine which uses either synchronous generators (SG) or asynchronous generators (AG). Some type 4 wind turbines use direct drive synchronous generators, and therefore have no gearbox. There are two type 4 models as follows: - type 4A: a model neglecting the aerodynamic and mechanical parts and thus not simulating any power oscillations; - type 4B: a model including a 2-mass mechanical model to replicate the power oscillations but assuming constant aerodynamic torque. The standard interconnections for the two models are shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.5.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 01:46:062022-03-18 21:38:16
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{DD7349EB-9F4E-448c-8883-68D35B0C7478}
Diagram notes
A dynamic model representing a type 4 wind turbine which uses either synchronous generators (SG) or asynchronous generators (AG). Some type 4 wind turbines use direct drive synchronous generators, and therefore have no gearbox. There are two type 4 models as follows: - type 4A: a model neglecting the aerodynamic and mechanical parts and thus not simulating any power oscillations; - type 4B: a model including a 2-mass mechanical model to replicate the power oscillations but assuming constant aerodynamic torque. The standard interconnections for the two models are shown in the figure. Reference: IEC 61400-27-1:2015, 5.5.5.
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 01:46:062022-03-18 21:38:16
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
Diagram 'StandardInterconnectionWindTurbineType4Aand4B' has no other changes. The shows its notes and every changed property.
▶▦StandardWindType1and2Interconnectioni
Diagram notes
This diagram shows the classes necessary for wind type 1 and type 2 interconnection models. Standard IEC wind turbines type 1 and 2 interconnection models all have a single instance of an AsynchronousMachineDynamics child class and a single instance of the WindGenTurbineType1aIEC class, the WindGenTurbineType1bIEC class, or the WindGenTurbineType2IEC class as appropriate. A valid IEC wind type 1A interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindAeroConstIEC; - WindProtectionIEC. A valid IEC wind type 1B interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindProtectionIEC; - WindPitchContPowerIEC. A valid IEC wind type 2 interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindContRotorRIEC; - WindProtectionIEC; - WindPitchContPowerIEC. The WindProtectionIEC class and the WindContRotorRIEC class use the WindDynamicsLookupTable class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 20:59:592022-03-18 21:38:25
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{92C68727-B7DF-4926-871E-3156A89CC82A}
Diagram notes
This diagram shows the classes necessary for wind type 1 and type 2 interconnection models. Standard IEC wind turbines type 1 and 2 interconnection models all have a single instance of an AsynchronousMachineDynamics child class and a single instance of the WindGenTurbineType1aIEC class, the WindGenTurbineType1bIEC class, or the WindGenTurbineType2IEC class as appropriate. A valid IEC wind type 1A interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindAeroConstIEC; - WindProtectionIEC. A valid IEC wind type 1B interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindProtectionIEC; - WindPitchContPowerIEC. A valid IEC wind type 2 interconnection model also shall have one instance of each of the following classes (and no others): - WindMechIEC; - WindContRotorRIEC; - WindProtectionIEC; - WindPitchContPowerIEC. The WindProtectionIEC class and the WindContRotorRIEC class use the WindDynamicsLookupTable class.
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 20:59:592022-03-18 21:38:25
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
▦Diagram
addedchangedmoved or resized
Baseline
StandardWindType1and2Interconnection (baseline)
Destination
StandardWindType1and2Interconnection (destination)
Connectors 12 labels movedhover a connector to outline the elements it joins
labels movedAsynchronousMachineDynamics – AsynchronousMachine
labels movedBaseVoltage – ConductingEquipment
labels movedRemoteInputSignal – Terminal
labels movedTerminal – ConductingEquipment
labels movedWindAeroConstIEC – WindGenTurbineType1aIEC
labels movedWindContRotorRIEC – WindGenTurbineType2IEC
labels movedWindGenTurbineType1bIEC – WindPitchContPowerIEC
labels movedWindMechIEC – WindTurbineType1or2IEC
labels movedWindPitchContPowerIEC – WindGenTurbineType2IEC
labels movedWindProtectionIEC – WindTurbineType1or2IEC
labels movedWindTurbineType1or2Dynamics – AsynchronousMachineDynamics
labels movedWindTurbineType1or2Dynamics – RemoteInputSignal
▶▦StandardWindType3and4Interconnectioni
Diagram notes
This diagram shows the classes necessary for wind type 3 and type 4 interconnection models, including the wind plant model. Standard IEC wind types 3, 4A, 4B and plant interconnection models all have a single instances as follows: IEC wind type 3: - WindTurbineType3IEC; - WindAeroOneDimIEC or WindAeroTwoDimIEC; - WindMechIEC; - WindGenType3aIEC or WindGenType3bIEC; - WindContPType3IEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindContPitchAngleIEC; - WindProtectionIEC. IEC wind type 4A: - WindTurbineType4aIEC; - WindGenType4IEC or WindGenType3aIEC; - WindContPType4aIEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindProtectionIEC. IEC wind type 4B: - WindTurbineType4bIEC; - WindMechIEC; - WindGenType4IEC or WindGenType3aIEC; - WindContPType4bIEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindProtectionIEC.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:38:34
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
MOVEDfrom StandardInterconnections{0E374383-A1C7-4ecb-A4C4-5889C2D6D200}
Diagram notes
This diagram shows the classes necessary for wind type 3 and type 4 interconnection models, including the wind plant model. Standard IEC wind types 3, 4A, 4B and plant interconnection models all have a single instances as follows: IEC wind type 3: - WindTurbineType3IEC; - WindAeroOneDimIEC or WindAeroTwoDimIEC; - WindMechIEC; - WindGenType3aIEC or WindGenType3bIEC; - WindContPType3IEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindContPitchAngleIEC; - WindProtectionIEC. IEC wind type 4A: - WindTurbineType4aIEC; - WindGenType4IEC or WindGenType3aIEC; - WindContPType4aIEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindProtectionIEC. IEC wind type 4B: - WindTurbineType4bIEC; - WindMechIEC; - WindGenType4IEC or WindGenType3aIEC; - WindContPType4bIEC; - WindContQIEC; - WindContCurrLimIEC; - WindContQLimIEC or WindContQPQULimIEC; - WindProtectionIEC.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:38:34
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637AEAPK_6319640C_8A7E_4aae_A1DA_A6DB83723377
ParentPackageStandardInterconnectionsWindModels
▦Diagram
addedchangedmoved or resized
Baseline
StandardWindType3and4Interconnection (baseline)
Destination
StandardWindType3and4Interconnection (destination)
Connectors 27 labels movedhover a connector to outline the elements it joins
labels movedBaseVoltage – ConductingEquipment
labels movedRemoteInputSignal – Terminal
labels movedTerminal – ConductingEquipment
labels movedWindAeroOneDimIEC – WindTurbineType3IEC
labels movedWindAeroTwoDimIEC – WindTurbineType3IEC
labels movedWindContCurrLimIEC – WindTurbineType3or4IEC
labels movedWindContPType3IEC – WindTurbineType3IEC
labels movedWindContPType4aIEC – WindTurbineType4aIEC
labels movedWindContPType4bIEC – WindTurbineType4bIEC
labels movedWindContPitchAngleIEC – WindTurbineType3IEC
labels movedWindContQIEC – WindTurbineType3or4IEC
labels movedWindContQLimIEC – WindTurbineType3or4IEC
labels movedWindContQPQULimIEC – WindTurbineType3or4IEC
labels movedWindGenType3IEC – WindTurbineType3IEC
labels movedWindGenType3aIEC – WindTurbineType4IEC
labels movedWindGenType4IEC – WindTurbineType4aIEC
labels movedWindGenType4IEC – WindTurbineType4bIEC
labels movedWindMechIEC – WindTurbineType3IEC
labels movedWindMechIEC – WindTurbineType4bIEC
labels movedWindPlantDynamics – RemoteInputSignal
labels movedWindPlantDynamics – WindTurbineType3or4Dynamics
labels movedWindPlantFreqPcontrolIEC – WindPlantIEC
labels movedWindPlantIEC – WindPlantReactiveControlIEC
labels movedWindProtectionIEC – WindTurbineType3or4IEC
labels movedWindRefFrameRotIEC – WindTurbineType3or4IEC
labels movedWindTurbineType3or4Dynamics – PowerElectronicsConnection
labels movedWindTurbineType3or4Dynamics – RemoteInputSignal
Changed classes (1)
▶⚙RemoteInputSignali
Class notes
Supports connection to a terminal associated with a remote bus from which an input signal of a specific type is coming.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{4343E844-5BAF-4175-9144-8319CA06EF02}
Class notes
Supports connection to a terminal associated with a remote bus from which an input signal of a specific type is coming.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
phasei{FF88D6EC-E293-4383-A3AF-C90236AD238A}show detailsdid not existSinglePhaseKind [0..1]Phase code of the phase which is used as a remote input signal. Some interconnections may instead use phase-to-phase voltages or process multiple voltages. These are documented in relevant classes, e.g., DERIEEEType1 shall not use the RemoteInputSignal.phase attribute.
Attribute notes
Phase code of the phase which is used as a remote input signal. Some interconnections may instead use phase-to-phase voltages or process multiple voltages. These are documented in relevant classes, e.g., DERIEEEType1 shall not use the RemoteInputSignal.phase attribute.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namephase
Scale0
Scopepublic
Staticfalse
TypeSinglePhaseKind
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
DestinationDERDynamics role DERDynamics [0..*] → RemoteInputSignal role RemoteInputSignal [0..*]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndDERDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleDERDynamics
RoleNoteDER dynamics model which has a remote input signal.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0..*
ContainmentUnspecified
EndRemoteInputSignal
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleRemoteInputSignal
RoleNoteThe remote input signal for this DER dynamics.
Scopepublic
TargetScopeinstance
Added diagrams (1)
▶▦StandardShuntCompensatorInterconnectioni
Diagram notes
This diagram shows the classes necessary for a shunt compensator interconnection model.
Diagram metadata — changes
BaselineDestination
Authorchiva
CreatedDate2022-02-19 11:21:46
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:37:28
NameStandardShuntCompensatorInterconnection
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637A
ParentPackageStandardInterconnections
ADDED{CDBC6F98-31F5-44f4-9B85-6C2A685AF051}
Diagram notes
This diagram shows the classes necessary for a shunt compensator interconnection model.
▤Metadata
BaselineDestination
Authorchiva
CreatedDate2022-02-19 11:21:46
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:37:28
NameStandardShuntCompensatorInterconnection
PackageEAPK_9E32B79D_9C05_4fe4_9518_A32B1C67637A
ParentPackageStandardInterconnections
▦Diagram
Baseline
Diagram did not exist in the baseline model.
Destination
StandardShuntCompensatorInterconnection (destination)
Changed diagrams (9)
▶▦StandardAsynchronousMachineInterconnectioni
Diagram notes
This diagram shows the classes necessary for the asynchronous machine interconnection model. A standard asynchronous machine interconnection has a single instance of an AsynchronousMachineDynamics child class. A valid standard asynchronous machine interconnection model also reflects the following rules. It can have: - one instance of TurbineGovernorDynamics child class, but only if AsynchronousMachine.asynchronousMachineType = generator; - one instance of MechanicalLoadDynamics child class, but only if AsynchronousMachine.asynchronousMachineType = motor.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:36:19
CHANGED{EEC3EEE6-B14D-4a4d-ACA6-86603C0764C4}
Diagram notes
This diagram shows the classes necessary for the asynchronous machine interconnection model. A standard asynchronous machine interconnection has a single instance of an AsynchronousMachineDynamics child class. A valid standard asynchronous machine interconnection model also reflects the following rules. It can have: - one instance of TurbineGovernorDynamics child class, but only if AsynchronousMachine.asynchronousMachineType = generator; - one instance of MechanicalLoadDynamics child class, but only if AsynchronousMachine.asynchronousMachineType = motor.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:36:19
▦Diagram
addedchangedmoved or resized
Baseline
StandardAsynchronousMachineInterconnection (baseline)
Destination
StandardAsynchronousMachineInterconnection (destination)
Connectors 5 labels movedhover a connector to outline the elements it joins
labels movedAsynchronousMachineDynamics – AsynchronousMachine
labels movedBaseVoltage – ConductingEquipment
labels movedMechanicalLoadDynamics – AsynchronousMachineDynamics
labels movedTerminal – ConductingEquipment
labels movedTurbineGovernorDynamics – AsynchronousMachineDynamics
▶▦StandardHVDCInterconnectioni
Diagram notes
This diagram shows the classes necessary for a HVDC interconnection model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:37:03
CHANGED{A4944F51-D732-4197-843E-0B8C8F5EED0B}
Diagram notes
This diagram shows the classes necessary for a HVDC interconnection model.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:37:03
▦Diagram
addedchangedmoved or resized
Baseline
StandardHVDCInterconnection (baseline)
Destination
StandardHVDCInterconnection (destination)
Connectors 5 added · 2 rerouted · 2 labels movedhover a connector to outline the elements it joins
addedDCConverterUnit – DCEquipmentContainer
addedDCLine – DCEquipmentContainer
addedHVDCInterconnectionDynamics – DCEquipmentContainer
addedHVDCInterconnectionDynamics – HVDCDynamics
addedHVDCInterconnectionUserDefined – HVDCInterconnectionDynamics
reroutedCSCUserDefined – CSCDynamics
reroutedHVDCDynamics – DynamicsFunctionBlock
labels movedCSCDynamics – CsConverter
labels movedVSCDynamics – VsConverter
▶▦StandardInterconnectionAsynchronousMachinei
Diagram notes
A dynamic model including an asynchronous machine (either a generator or motor) and its related equipment models (function blocks) is associated with an asynchronous machine in the static (power flow) model and has the standard interconnection shown above. This interconnection is for a “squirrel-cage” induction machine or a wound-rotor induction machine with short-circuited field windings. Other models and a different interconnection are required for a wound-rotor machine with external connections to the field windings. The interface between the dynamic asynchronous machine and the network algebraic equations is application-dependent.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-16 23:29:212022-03-18 21:35:33
CHANGED{817CAAD0-AD44-4557-AB1E-7846B07518FC}
Diagram notes
A dynamic model including an asynchronous machine (either a generator or motor) and its related equipment models (function blocks) is associated with an asynchronous machine in the static (power flow) model and has the standard interconnection shown above. This interconnection is for a “squirrel-cage” induction machine or a wound-rotor induction machine with short-circuited field windings. Other models and a different interconnection are required for a wound-rotor machine with external connections to the field windings. The interface between the dynamic asynchronous machine and the network algebraic equations is application-dependent.
▤Metadata
BaselineDestination
ModifiedDate2017-06-16 23:29:212022-03-18 21:35:33
Diagram 'StandardInterconnectionAsynchronousMachine' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionSingleLoadi
Diagram notes
A load model is associated with an energy consumer in the power flow data and has no standard interconnection with other models. The P and Q consumption of the load are determined as a function of the magnitude and frequency of the voltage at the terminal bus as shown above. The interface between the model and the network algebraic equations is application-dependent. Dynamic (motor) load models generally interface with the network equations in a similar manner to motor models.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 01:45:442022-03-18 21:35:47
CHANGED{1F16C8BB-62BD-40a6-BFB5-D02410050029}
Diagram notes
A load model is associated with an energy consumer in the power flow data and has no standard interconnection with other models. The P and Q consumption of the load are determined as a function of the magnitude and frequency of the voltage at the terminal bus as shown above. The interface between the model and the network algebraic equations is application-dependent. Dynamic (motor) load models generally interface with the network equations in a similar manner to motor models.
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 01:45:442022-03-18 21:35:47
Diagram 'StandardInterconnectionSingleLoad' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionSynchronousGeneratorCrossCompoundi
Diagram notes
A cross-compound dynamic model that includes multiple synchronous generators and their related equipment models (function blocks), is associated with multiple synchronous machines in the static (power flow) model and has the standard interconnection shown above. Generator 2 is the second unit of a cross-compound pair of generators and is usually connected to the same terminal bus. A single turbine-governor model determines the mechanical power for both units.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-07-20 19:30:112022-03-18 21:35:22
CHANGED{303F1583-2BF7-44ca-B795-D91B8979C1FC}
Diagram notes
A cross-compound dynamic model that includes multiple synchronous generators and their related equipment models (function blocks), is associated with multiple synchronous machines in the static (power flow) model and has the standard interconnection shown above. Generator 2 is the second unit of a cross-compound pair of generators and is usually connected to the same terminal bus. A single turbine-governor model determines the mechanical power for both units.
▤Metadata
BaselineDestination
ModifiedDate2017-07-20 19:30:112022-03-18 21:35:22
Diagram 'StandardInterconnectionSynchronousGeneratorCrossCompound' has no other changes. The shows its notes and every changed property.
▶▦StandardInterconnectionSynchronousMachinei
Diagram notes
A dynamic model that includes a single synchronous machine (generator, motor or condenser) and its related equipment models (function blocks) is associated with a synchronous machine in the static (power flow) model and has the standard interconnection shown above. The interface between the dynamic synchronous machine and the network algebraic equations is application dependent. The variables used for this interface do not need to be identified since they are internal to the application program, well-defined and not necessary to be exchanged between applications. The interfaces between different blocks in the above figure are indicative of the variety of input and output signals that are defined by the individual standard models. The figure provides information on most of the alternative interfaces, for instance, the turbine-governor (for generators) or the mechanical load (for motors) and the dynamic synchronous machine can be mechanical torque (<i>Tm</i>) or mechanical power (<i>Pm</i>).
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-16 23:29:052022-03-18 21:31:38
CHANGED{B1BE5693-498D-4525-8F3C-EABC32D6277D}
Diagram notes
A dynamic model that includes a single synchronous machine (generator, motor or condenser) and its related equipment models (function blocks) is associated with a synchronous machine in the static (power flow) model and has the standard interconnection shown above. The interface between the dynamic synchronous machine and the network algebraic equations is application dependent. The variables used for this interface do not need to be identified since they are internal to the application program, well-defined and not necessary to be exchanged between applications. The interfaces between different blocks in the above figure are indicative of the variety of input and output signals that are defined by the individual standard models. The figure provides information on most of the alternative interfaces, for instance, the turbine-governor (for generators) or the mechanical load (for motors) and the dynamic synchronous machine can be mechanical torque (<i>Tm</i>) or mechanical power (<i>Pm</i>).
▤Metadata
BaselineDestination
ModifiedDate2017-06-16 23:29:052022-03-18 21:31:38
Diagram 'StandardInterconnectionSynchronousMachine' has no other changes. The shows its notes and every changed property.
▶▦StandardLoadInterconnectioni
Diagram notes
This diagram shows the classes necessary for a load interconnection model. A standard load interconnection model has a single instance of an EnergyConsumerDynamics child class plus a related instance of a LoadDynamics child class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:33:54
CHANGED{33C2E7D0-74C1-41cc-A2D0-FD0D05FD9A07}
Diagram notes
This diagram shows the classes necessary for a load interconnection model. A standard load interconnection model has a single instance of an EnergyConsumerDynamics child class plus a related instance of a LoadDynamics child class.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:33:54
▦Diagram
addedchangedmoved or resized
Baseline
StandardLoadInterconnection (baseline)
Destination
StandardLoadInterconnection (destination)
Connectors 3 labels movedhover a connector to outline the elements it joins
labels movedBaseVoltage – ConductingEquipment
labels movedLoadDynamics – EnergyConsumer
labels movedTerminal – ConductingEquipment
▶▦StandardStaticVarCompensatorInterconnectioni
Diagram notes
This diagram shows the classes necessary for a static var compensator (SVC) interconnection model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-07-22 08:55:182022-03-18 21:37:17
CHANGED{4EFB908C-5452-4b3b-A521-8C8B72F709CE}
Diagram notes
This diagram shows the classes necessary for a static var compensator (SVC) interconnection model.
▤Metadata
BaselineDestination
ModifiedDate2017-07-22 08:55:182022-03-18 21:37:17
▦Diagram
addedchangedmoved or resized
Baseline
StandardStaticVarCompensatorInterconnection (baseline)
Destination
StandardStaticVarCompensatorInterconnection (destination)
Connectors 2 added · 1 reroutedhover a connector to outline the elements it joins
addedStaticVarCompensatorSystemDynamics – ShuntCompensator
addedStaticVarCompensatorSystemDynamics – StaticVarCompensatorDynamics
reroutedStaticVarCompensatorDynamics – StaticVarCompensator
▶▦StandardSynchronousMachineInterconnectioni
Diagram notes
This diagram shows the classes necessary for both of the two types of synchronous machine interconnection models: standard synchronous machine and standard synchronous generator cross-compound. A standard synchronous machine interconnection has a single instance of a SynchronousMachineDynamics child class whereas a generator cross-compound connection has multiple instances of SynchronousMachineDynamics child classes related by a single instance of a TurbineGovernorDynamics child class. A valid standard synchronous machine interconnection model reflects the following rules. - It can have: + one instance of TurbineGovernorDynamics child class, but only if SynchronousMachine.operatingMode = generator; + one instance of MechanicalLoadDynamics child class, but only if SynchronousMachine.operatingMode = motor or SynchronousMachine.operatingMode = condenser. - It cannot have any instance of GenICompensationForGenJ. A generator cross-compound interconnection model reflects the following rules. - It can have: + multiple instances of SynchronousMachineDynamics child classes, each of which has its related SynchronousMachine.operatingMode = generator; + one instance of TurbineGovernorDynamics child class. - It shall have two or more instances of GenICompensationForGenJ associated with each instance of a SynchronousMachineDynamics child class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:36:04
CHANGED{EC9A727C-9695-44d0-BDFE-9C76CF1CF162}
Diagram notes
This diagram shows the classes necessary for both of the two types of synchronous machine interconnection models: standard synchronous machine and standard synchronous generator cross-compound. A standard synchronous machine interconnection has a single instance of a SynchronousMachineDynamics child class whereas a generator cross-compound connection has multiple instances of SynchronousMachineDynamics child classes related by a single instance of a TurbineGovernorDynamics child class. A valid standard synchronous machine interconnection model reflects the following rules. - It can have: + one instance of TurbineGovernorDynamics child class, but only if SynchronousMachine.operatingMode = generator; + one instance of MechanicalLoadDynamics child class, but only if SynchronousMachine.operatingMode = motor or SynchronousMachine.operatingMode = condenser. - It cannot have any instance of GenICompensationForGenJ. A generator cross-compound interconnection model reflects the following rules. - It can have: + multiple instances of SynchronousMachineDynamics child classes, each of which has its related SynchronousMachine.operatingMode = generator; + one instance of TurbineGovernorDynamics child class. - It shall have two or more instances of GenICompensationForGenJ associated with each instance of a SynchronousMachineDynamics child class.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:36:04
▦Diagram
addedchangedmoved or resized
Baseline
StandardSynchronousMachineInterconnection (baseline)
Destination
StandardSynchronousMachineInterconnection (destination)
Connectors 1 rerouted · 22 labels movedhover a connector to outline the elements it joins
reroutedMechanicalLoadDynamics – SynchronousMachineDynamics
labels moved(not in this model) – ConductingEquipment
labels movedDiscontinuousExcitationControlDynamics – ExcitationSystemDynamics
labels movedDiscontinuousExcitationControlDynamics – RemoteInputSignal
labels movedExcitationSystemDynamics – SynchronousMachineDynamics
labels movedGenICompensationForGenJ – SynchronousMachineDynamics
labels movedGenICompensationForGenJ – VCompIEEEType2
labels movedOverexcitationLimiterDynamics – ExcitationSystemDynamics
labels movedPFVArControllerType1Dynamics – ExcitationSystemDynamics
labels movedPFVArControllerType1Dynamics – RemoteInputSignal
labels movedPFVArControllerType2Dynamics – ExcitationSystemDynamics
labels movedPowerSystemStabilizerDynamics – ExcitationSystemDynamics
labels movedPowerSystemStabilizerDynamics – RemoteInputSignal
labels movedRemoteInputSignal – Terminal
labels movedSynchronousMachineDynamics – SynchronousMachine
labels movedSynchronousMachineDynamics – TurbineGovernorDynamics
labels movedTerminal – ConductingEquipment
labels movedTurbineLoadControllerDynamics – TurbineGovernorDynamics
labels movedUnderexcitationLimiterDynamics – ExcitationSystemDynamics
labels movedUnderexcitationLimiterDynamics – RemoteInputSignal
labels movedVoltageAdjusterDynamics – PFVArControllerType1Dynamics
labels movedVoltageCompensatorDynamics – ExcitationSystemDynamics
labels movedVoltageCompensatorDynamics – RemoteInputSignal
▶StandardModelsi
Package notes
This subclause contains standard dynamic model specifications grouped into packages by standard function block (type of equipment being modelled). In the CIM, standard dynamic models are expressed by means of a class named with the standard model name and attributes reflecting each of the parameters necessary to describe the behaviour of an instance of the standard model.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/StandardModels/1.0
version(no tag)1.0.0
CHANGED{1BEB429C-BFD0-49c6-9556-AC7BA58C2202}
Package notes
This subclause contains standard dynamic model specifications grouped into packages by standard function block (type of equipment being modelled). In the CIM, standard dynamic models are expressed by means of a class named with the standard model name and attributes reflecting each of the parameters necessary to describe the behaviour of an instance of the standard model.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/StandardModels/1.0
version(no tag)1.0.0
▶SynchronousMachineDynamicsi
Package notes
For conventional power generating units (e.g., thermal, hydro, combustion turbine), a synchronous machine model represents the electrical characteristics of the generator and the mechanical characteristics of the turbine-generator rotational inertia. Large industrial motors or groups of similar motors can be represented by individual motor models which are represented as generators with negative active power in the static (power flow) data. The interconnection with the electrical network equations can differ among simulation tools. The tool only needs to know the synchronous machine to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/SynchronousMachineDynamics/1.0
version(no tag)1.0.0
CHANGED{448F8675-D39C-4fe0-9450-2791AE603EFC}
Package notes
For conventional power generating units (e.g., thermal, hydro, combustion turbine), a synchronous machine model represents the electrical characteristics of the generator and the mechanical characteristics of the turbine-generator rotational inertia. Large industrial motors or groups of similar motors can be represented by individual motor models which are represented as generators with negative active power in the static (power flow) data. The interconnection with the electrical network equations can differ among simulation tools. The tool only needs to know the synchronous machine to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/SynchronousMachineDynamics/1.0
version(no tag)1.0.0
Changed classes (4)
▶⚙SynchronousMachineDetailedi
Class notes
All synchronous machine detailed types use a subset of the same data parameters and input/output variables. The several variations differ in the following ways: - the number of equivalent windings that are included; - the way in which saturation is incorporated into the model; - whether or not “subtransient saliency” (<i>X''q</i> not = <i>X''d</i>) is represented. It is not necessary for each simulation tool to have separate models for each of the model types. The same model can often be used for several types by alternative logic within the model. Also, differences in saturation representation might not result in significant model performance differences so model substitutions are often acceptable.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{B272216C-A098-436d-80C8-02AD11F5B97F}
Class notes
All synchronous machine detailed types use a subset of the same data parameters and input/output variables. The several variations differ in the following ways: - the number of equivalent windings that are included; - the way in which saturation is incorporated into the model; - whether or not “subtransient saliency” (<i>X''q</i> not = <i>X''d</i>) is represented. It is not necessary for each simulation tool to have separate models for each of the model types. The same model can often be used for several types by alternative logic within the model. Also, differences in saturation representation might not result in significant model performance differences so model substitutions are often acceptable.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
saturationFactori{43DE8A9C-88A1-48c1-BC53-2022481FD579}show detailsdid not existFloat [0..1]Saturation factor at rated terminal voltage (<i>S1</i>) (>= 0). Defined by defined by <i>S</i>(<i>E1</i>) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,02.
Attribute notes
Saturation factor at rated terminal voltage (<i>S1</i>) (>= 0). Defined by defined by <i>S</i>(<i>E1</i>) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
NamesaturationFactor
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
saturationFactor120i{E4937370-1EC7-4358-8FC2-3A6D3AF17808}show detailsdid not existFloat [0..1]Saturation factor at 120 % of rated terminal voltage (<i>S12</i>) (>= RotatingMachineDynamics.saturationFactor). Defined by <i>S</i>(<i>E2</i>) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,12.
Attribute notes
Saturation factor at 120 % of rated terminal voltage (<i>S12</i>) (>= RotatingMachineDynamics.saturationFactor). Defined by <i>S</i>(<i>E2</i>) in the SynchronousMachineSaturationParameters diagram. Typical value = 0,12.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
NamesaturationFactor120
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙SynchronousMachineDynamicsi
Class notes
Synchronous machine whose behaviour is described by reference to a standard model expressed in one of the following forms: - simplified (or classical), where a group of generators or motors is not modelled in detail; - detailed, in equivalent circuit form; - detailed, in time constant reactance form; or <font color="#0f0f0f">- by definition of a user-defined model.</font> <font color="#0f0f0f">It is a common practice to represent small generators by a negative load rather than by a dynamic generator model when performing dynamics simulations. In this case, a SynchronousMachine in the static model is not represented by anything in the dynamics model, instead it is treated as an ordinary load.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><font color="#0f0f0f">Synchronous machine parameters such as <i>Xl, Xd, Xp</i> etc. are actually used as inductances in the models,</font> but are commonly referred to as reactances since, at nominal frequency, the PU values are the same. However, some references use the symbol <i>L</i> instead of <i>X</i>.</li> </ol>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{575BECE2-4C08-40c3-9B81-1C8E6F4FCF8C}
Class notes
Synchronous machine whose behaviour is described by reference to a standard model expressed in one of the following forms: - simplified (or classical), where a group of generators or motors is not modelled in detail; - detailed, in equivalent circuit form; - detailed, in time constant reactance form; or <font color="#0f0f0f">- by definition of a user-defined model.</font> <font color="#0f0f0f">It is a common practice to represent small generators by a negative load rather than by a dynamic generator model when performing dynamics simulations. In this case, a SynchronousMachine in the static model is not represented by anything in the dynamics model, instead it is treated as an ordinary load.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><font color="#0f0f0f">Synchronous machine parameters such as <i>Xl, Xd, Xp</i> etc. are actually used as inductances in the models,</font> but are commonly referred to as reactances since, at nominal frequency, the PU values are the same. However, some references use the symbol <i>L</i> instead of <i>X</i>.</li> </ol>
⇄Links
BaselineMechanicalLoadDynamics role MechanicalLoadDynamics [0..1] → SynchronousMachineDynamics role SynchronousMachineDynamics [0..1]
→
DestinationMechanicalLoadDynamics role MechanicalLoadDynamics [0..1] → SynchronousMachineDynamics role SynchronousMachineDynamics [0..1]
Source end
no changes
Target end — SynchronousMachineDynamics
BaselineDestination
RoleNoteSynchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or AsynchronousMachineDyanmics.Synchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or AsynchronousMachineDyanmicsAsynchronousMachineDynamics.
BaselineCrossCompoundTurbineGovernorDynamics role CrossCompoundTurbineGovernorDyanmics [0..1] → SynchronousMachineDynamics role HighPressureSynchronousMachineDynamics [1]
→
DestinationCrossCompoundTurbineGovernorDynamics role CrossCompoundTurbineGovernorDyanmicsCrossCompoundTurbineGovernorDynamics [0..1] → SynchronousMachineDynamics role HighPressureSynchronousMachineDynamics [1]
Source end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
RoleCrossCompoundTurbineGovernorDyanmicsCrossCompoundTurbineGovernorDynamics
Target end
no changes
▶⚙SynchronousMachineModelKind«enumeration»i
Class notes
Type of synchronous machine model used in dynamic simulation applications.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{EE3419FE-0A7A-4b84-9D7B-AB4A48EE501D}
Class notes
Type of synchronous machine model used in dynamic simulation applications.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
subtransienti{D2B83ED1-6190-4d28-B8E7-4227C3C9F4DC}show details [1..1] [1..1]Subtransient synchronous machine model. Subtransient synchronous machine model. In order to model type SubtransientSilentPole standard model type the SynchronousMachineTimeConstantReactance.modelType shall be set to subtransient, .rotorType shall be set to salientPole and the attributes SynchronousMachineDetailed.saturationFactorQAxis and SynchronousMachineDetailed.saturationFactor120QAxisthe are either not exchanged or set to 0. In order to model type SubtransientRoundRotor standard model type the SynchronousMachineTimeConstantReactance.modelType shall be set to subtransient, .rotorType shall be set to is roundRotor and the following attributes are required: – SynchronousMachineTimeConstantReactance.xQuadTrans – SynchronousMachineTimeConstantReactance.tpqo – SynchronousMachineDetailed.saturationFactorQAxis – SynchronousMachineDetailed.saturationFactor120QAxis – RotatingMachineDynamics.saturationFactor – RotatingMachineDynamics.saturationFactor120.
Attribute notes (destination, redlined)
Subtransient synchronous machine model. Subtransient synchronous machine model. In order to model type SubtransientSilentPole standard model type the SynchronousMachineTimeConstantReactance.modelType shall be set to subtransient, .rotorType shall be set to salientPole and the attributes SynchronousMachineDetailed.saturationFactorQAxis and SynchronousMachineDetailed.saturationFactor120QAxisthe are either not exchanged or set to 0. In order to model type SubtransientRoundRotor standard model type the SynchronousMachineTimeConstantReactance.modelType shall be set to subtransient, .rotorType shall be set to is roundRotor and the following attributes are required: – SynchronousMachineTimeConstantReactance.xQuadTrans – SynchronousMachineTimeConstantReactance.tpqo – SynchronousMachineDetailed.saturationFactorQAxis – SynchronousMachineDetailed.saturationFactor120QAxis – RotatingMachineDynamics.saturationFactor – RotatingMachineDynamics.saturationFactor120.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
subtransientSimplifiedi{3A6850C7-98D5-4f40-8A3D-4A7E868646EC}show details [1..1] [1..1]Simplified version of subtransient synchronous machine model where magnetic coupling between the direct- and quadrature- axes is ignored. Therefore if the SynchronousMachineTimeConstantReactance.modelType is set to subtransientSimplified and SynchronousMachineTimeConstantReactance.rotorType is set to roundRotor the attributes SynchronousMachineDetailed.saturationFactorQAxis, SynchronousMachineDetailed.saturationFactor120QAxis and RotatingMachineDynamics.statorResistance are either not exchanged or set to 0.
Attribute notes (destination, redlined)
Simplified version of subtransient synchronous machine model where magnetic coupling between the direct- and quadrature- axes is ignored. Therefore if the SynchronousMachineTimeConstantReactance.modelType is set to subtransientSimplified and SynchronousMachineTimeConstantReactance.rotorType is set to roundRotor the attributes SynchronousMachineDetailed.saturationFactorQAxis, SynchronousMachineDetailed.saturationFactor120QAxis and RotatingMachineDynamics.statorResistance are either not exchanged or set to 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙SynchronousMachineTimeConstantReactancei
Class notes (destination, redlined)
Synchronous machine detailed modelling types are defined by the combination of the attributes SynchronousMachineTimeConstantReactance.modelType and SynchronousMachineTimeConstantReactance.rotorType. Parameter details: <ol> <li>The “p” in the time-related attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpdo refers to <i>T'do</i>.</li> <li>The parameters used for models expressed in time constant reactance form include:</li> </ol> - RotatingMachine.ratedS (<i>MVAbase</i>); - RotatingMachineDynamics.damping (<i>D</i>); - RotatingMachineDynamics.inertia (<i>H</i>); - RotatingMachineDynamics.saturationFactor (<i>S1</i>); - RotatingMachineDynamics.saturationFactor120 (<i>S12</i>); - RotatingMachineDynamics.statorLeakageReactance (<i>Xl</i>); - RotatingMachineDynamics.statorResistance (<i>Rs</i>); - SynchronousMachineTimeConstantReactance.ks (<i>Ks</i>); - SynchronousMachineDetailed.saturationFactorQAxis (<i>S1q</i>); - SynchronousMachineDetailed.saturationFactor120QAxis (<i>S12q</i>); - SynchronousMachineDetailed.efdBaseRatio; - SynchronousMachineDetailed.ifdBaseType; - .xDirectSync (<i>Xd</i>); - .xDirectTrans (<i>X'd</i>); - .xDirectSubtrans (<i>X''d</i>); - .xQuadSync (<i>Xq</i>); - .xQuadTrans (<i>X'q</i>); - .xQuadSubtrans (<i>X''q</i>); - .tpdo (<i>T'do</i>); - .tppdo (<i>T''do</i>); - .tpqo (<i>T'qo</i>); - .tppqo (<i>T''qo</i>); - .tc. Synchronous machine detailed modelling types are defined by the combination of the attributes SynchronousMachineTimeConstantReactance.modelType and SynchronousMachineTimeConstantReactance.rotorType. Parameter details: <ol> <li>The “p” in the time-related attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpdo refers to <i>T'do</i>.</li> </ol>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C6F04365-226C-4457-AE52-86A30D76F764}
Class notes (destination, redlined)
Synchronous machine detailed modelling types are defined by the combination of the attributes SynchronousMachineTimeConstantReactance.modelType and SynchronousMachineTimeConstantReactance.rotorType. Parameter details: <ol> <li>The “p” in the time-related attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpdo refers to <i>T'do</i>.</li> <li>The parameters used for models expressed in time constant reactance form include:</li> </ol> - RotatingMachine.ratedS (<i>MVAbase</i>); - RotatingMachineDynamics.damping (<i>D</i>); - RotatingMachineDynamics.inertia (<i>H</i>); - RotatingMachineDynamics.saturationFactor (<i>S1</i>); - RotatingMachineDynamics.saturationFactor120 (<i>S12</i>); - RotatingMachineDynamics.statorLeakageReactance (<i>Xl</i>); - RotatingMachineDynamics.statorResistance (<i>Rs</i>); - SynchronousMachineTimeConstantReactance.ks (<i>Ks</i>); - SynchronousMachineDetailed.saturationFactorQAxis (<i>S1q</i>); - SynchronousMachineDetailed.saturationFactor120QAxis (<i>S12q</i>); - SynchronousMachineDetailed.efdBaseRatio; - SynchronousMachineDetailed.ifdBaseType; - .xDirectSync (<i>Xd</i>); - .xDirectTrans (<i>X'd</i>); - .xDirectSubtrans (<i>X''d</i>); - .xQuadSync (<i>Xq</i>); - .xQuadTrans (<i>X'q</i>); - .xQuadSubtrans (<i>X''q</i>); - .tpdo (<i>T'do</i>); - .tppdo (<i>T''do</i>); - .tpqo (<i>T'qo</i>); - .tppqo (<i>T''qo</i>); - .tc. Synchronous machine detailed modelling types are defined by the combination of the attributes SynchronousMachineTimeConstantReactance.modelType and SynchronousMachineTimeConstantReactance.rotorType. Parameter details: <ol> <li>The “p” in the time-related attribute names is a substitution for a “prime” in the usual parameter notation, e.g. tpdo refers to <i>T'do</i>.</li> </ol>
Class 'SynchronousMachineTimeConstantReactance' has no other changes. The shows its notes and every changed property.
Changed diagrams (18)
▶▦Simplifiedi
Diagram notes
This diagram describes the simplified synchronous generator model. Parameter details: <ol> <li>The model is often used for gross equivalents of parts of a system that are not represented in detail. In this case the MVA rating would be the combined rating of all generators in the equivalenced area.</li> <li><i>Rs </i>+ <i>jXp</i> would be the short-circuit equivalent impedance at the location of the equivalent generator on the generator MVA rating base. Inertia constant (<i>H</i>) would be typical or average values for the generators in the equivalenced area.</li> <li>The internal reactance (<i>Xp</i>) can be labelled in different ways (<i>X’, X”, X’d, X”d</i>) by different simulation tools.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:42:582022-03-18 21:43:18
CHANGED{807D0F70-D75B-4eae-96B3-F0DDE58EC763}
Diagram notes
This diagram describes the simplified synchronous generator model. Parameter details: <ol> <li>The model is often used for gross equivalents of parts of a system that are not represented in detail. In this case the MVA rating would be the combined rating of all generators in the equivalenced area.</li> <li><i>Rs </i>+ <i>jXp</i> would be the short-circuit equivalent impedance at the location of the equivalent generator on the generator MVA rating base. Inertia constant (<i>H</i>) would be typical or average values for the generators in the equivalenced area.</li> <li>The internal reactance (<i>Xp</i>) can be labelled in different ways (<i>X’, X”, X’d, X”d</i>) by different simulation tools.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:42:582022-03-18 21:43:18
Diagram 'Simplified' has no other changes. The shows its notes and every changed property.
▶▦SubtransientRoundRotori
Diagram notes
The subtransient round rotor type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransient and .rotorType = roundRotor. The complete equivalent circuit is used with two rotor windings in each axis. <font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd </i>(<i>XadIfd</i>) and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to <i>Efd</i> in steady-state. </font> Parameter details: <ol> <li><font color="#0f0f0f"><i>X''q</i> can be assumed to be equal to <i>X''d</i> (no subtransient saliency).</font></li> <li><font color="#0f0f0f">Saturation is modelled in both the direct- and quadrature- axes.</font></li> <li><font color="#0f0f0f">For generators, the following parameters can be omitted with defaults shown: <i>X''q </i>(= <i>X''d</i>), <i>Ks</i> (= 0), <i>S1q</i> (= <i>S1</i>), <i>S12q</i> (= <i>S12</i>), <i>Tc</i> (= 0).</font></li> <li><font color="#0f0f0f">For motors, the following parameter is not used: <i>X''q</i>.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:44:422022-03-18 21:43:31
CHANGED{00259068-CA37-48ad-A2A8-2893497879EA}
Diagram notes
The subtransient round rotor type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransient and .rotorType = roundRotor. The complete equivalent circuit is used with two rotor windings in each axis. <font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd </i>(<i>XadIfd</i>) and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to <i>Efd</i> in steady-state. </font> Parameter details: <ol> <li><font color="#0f0f0f"><i>X''q</i> can be assumed to be equal to <i>X''d</i> (no subtransient saliency).</font></li> <li><font color="#0f0f0f">Saturation is modelled in both the direct- and quadrature- axes.</font></li> <li><font color="#0f0f0f">For generators, the following parameters can be omitted with defaults shown: <i>X''q </i>(= <i>X''d</i>), <i>Ks</i> (= 0), <i>S1q</i> (= <i>S1</i>), <i>S12q</i> (= <i>S12</i>), <i>Tc</i> (= 0).</font></li> <li><font color="#0f0f0f">For motors, the following parameter is not used: <i>X''q</i>.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:44:422022-03-18 21:43:31
Diagram 'SubtransientRoundRotor' has no other changes. The shows its notes and every changed property.
▶▦SubtransientRoundRotorSimplifiedi
Diagram notes
The subtransient round rotor simplified type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplified and .rotorKind = roundRotor. It is a simplified version of subtransient round rotor type, magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit and one equivalent damper circuit, <i>X'd</i> not = <i>X''d</i>.</li> <li>Quadrature-axis with two equivalent damper circuit,<i> X''q</i> not = <i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, X''d, T'do, T''do</i> and <i>Xq, X'q, X''q, T'qo, T''qo</i>.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 06:59:402022-03-18 21:44:54
CHANGED{9CC1DB49-E7E3-4524-8A45-A2ACACB234C4}
Diagram notes
The subtransient round rotor simplified type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplified and .rotorKind = roundRotor. It is a simplified version of subtransient round rotor type, magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit and one equivalent damper circuit, <i>X'd</i> not = <i>X''d</i>.</li> <li>Quadrature-axis with two equivalent damper circuit,<i> X''q</i> not = <i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, X''d, T'do, T''do</i> and <i>Xq, X'q, X''q, T'qo, T''qo</i>.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 06:59:402022-03-18 21:44:54
Diagram 'SubtransientRoundRotorSimplified' has no other changes. The shows its notes and every changed property.
▶▦SubtransientRoundRotorSimplifiedDirectAxisi
Diagram notes
The subtransient round rotor simplified direct-axis type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplifiedDirectAxis and .rotorKind = roundRotor. It is a simplified version of a subtransient round rotor type with no damper circuit on the <i>d</i>-axis. This simplification contributes to a reduction in computational effort by reducing the order of the differential equation system. The <i>q</i>-axis has two equivalent rotor windings. Magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit only, no equivalent damper circuit. Approximation: <i>X'd </i>= <i>X''d</i>.</li> <li>Quadrature-axis with two equivalent damper circuit, <i>X''q</i> not = <i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, T'do</i> and <i>Xq, X'q, X''q, T'qo, T''qo</i>.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 07:00:352022-03-18 21:44:37
CHANGED{C5E62B62-C37F-4f8b-BD89-14506F3D33F3}
Diagram notes
The subtransient round rotor simplified direct-axis type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplifiedDirectAxis and .rotorKind = roundRotor. It is a simplified version of a subtransient round rotor type with no damper circuit on the <i>d</i>-axis. This simplification contributes to a reduction in computational effort by reducing the order of the differential equation system. The <i>q</i>-axis has two equivalent rotor windings. Magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit only, no equivalent damper circuit. Approximation: <i>X'd </i>= <i>X''d</i>.</li> <li>Quadrature-axis with two equivalent damper circuit, <i>X''q</i> not = <i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, T'do</i> and <i>Xq, X'q, X''q, T'qo, T''qo</i>.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 07:00:352022-03-18 21:44:37
Diagram 'SubtransientRoundRotorSimplifiedDirectAxis' has no other changes. The shows its notes and every changed property.
▶▦SubtransientSalientPolei
Diagram notes
The subtransient salient pole type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransient and .rotorKind = salientPole. The <i>d</i>-axis equivalent circuit is the same as for the subtransient round rotor type. The <i>q</i>-axis has only one equivalent rotor winding, which can be labelled as transient (<i>X'q</i>) or subtransient (<i>X''q</i>); <i>X'q</i> is used for the CIM description. <font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd (XadIfd) </i>and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to<i> Efd</i> in steady-state. </font> Parameter details: <ol> <li><i>X''q</i> (=<i>X'q</i>) is assumed to be equal to <i>X''d</i> (no subtransient saliency).</li> <li>Saturation is modelled in the <i>d</i>-axis only.</li> <li>For generators, the following input parameters can be omitted with default shown: <i>X'q</i> (=<i>X''d</i>), <i>X''q</i> (=<i>X''d</i>), <i>T''qo</i>, <i>Ks</i> (=0), <i>S1q</i> (=0), <i>S12q </i>(=0), <i>Tc</i> (=0).</li> <li>For motors, the following input parameters are not used: <i>X'q, X''q, T''qo</i>.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:45:092022-03-18 21:43:48
CHANGED{F24EFF76-4677-4af2-AA8A-0679762303C6}
Diagram notes
The subtransient salient pole type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransient and .rotorKind = salientPole. The <i>d</i>-axis equivalent circuit is the same as for the subtransient round rotor type. The <i>q</i>-axis has only one equivalent rotor winding, which can be labelled as transient (<i>X'q</i>) or subtransient (<i>X''q</i>); <i>X'q</i> is used for the CIM description. <font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd (XadIfd) </i>and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to<i> Efd</i> in steady-state. </font> Parameter details: <ol> <li><i>X''q</i> (=<i>X'q</i>) is assumed to be equal to <i>X''d</i> (no subtransient saliency).</li> <li>Saturation is modelled in the <i>d</i>-axis only.</li> <li>For generators, the following input parameters can be omitted with default shown: <i>X'q</i> (=<i>X''d</i>), <i>X''q</i> (=<i>X''d</i>), <i>T''qo</i>, <i>Ks</i> (=0), <i>S1q</i> (=0), <i>S12q </i>(=0), <i>Tc</i> (=0).</li> <li>For motors, the following input parameters are not used: <i>X'q, X''q, T''qo</i>.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:45:092022-03-18 21:43:48
Diagram 'SubtransientSalientPole' has no other changes. The shows its notes and every changed property.
▶▦SubtransientSalientPoleSimplifiedi
Diagram notes
The subtransient salient pole simplified type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplified and .rotorKind = salientPole. It is a simplified version of subtransient salient pole type, magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit and one equivalent damper circuit, <i>X'd</i> not = <i>X''d</i>.</li> <li>Quadrature-axis with only one equivalent damper circuit, which is labeled as subtransient (<i>X''q</i>), <i>X''q</i> =<i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, X''d, T'do, T''do and Xq, X''q, T''qo</i>.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 07:00:022022-03-18 21:44:45
CHANGED{7BC83FB7-BE1A-4d88-BA2C-F8BD230FC827}
Diagram notes
The subtransient salient pole simplified type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplified and .rotorKind = salientPole. It is a simplified version of subtransient salient pole type, magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit and one equivalent damper circuit, <i>X'd</i> not = <i>X''d</i>.</li> <li>Quadrature-axis with only one equivalent damper circuit, which is labeled as subtransient (<i>X''q</i>), <i>X''q</i> =<i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, X''d, T'do, T''do and Xq, X''q, T''qo</i>.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 07:00:022022-03-18 21:44:45
Diagram 'SubtransientSalientPoleSimplified' has no other changes. The shows its notes and every changed property.
▶▦SubtransientSalientPoleSimplifiedDirectAxisi
Diagram notes
The subtransient salient pole simplified direct-axis type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplifiedDirectAxis and .rotorKind = salientPole. It is a simplified version of a subtransient salient pole type with no damper circuit on the <i>d</i>-axis. This simplification contributes to a reduction in computational effort by reducing the order of the differential equation system. The <i>q</i>-axis has only one equivalent rotor winding. Magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit only, no equivalent damper circuit. Approximation: <i>X'd</i> = <i>X''d</i>.</li> <li>Quadrature-axis with only one equivalent damper circuit, which is labelled as subtransient (<i>X''q</i>), <i>X''q</i> =<i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, T'do</i> and <i>Xq, X''q, T''qo</i>.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 09:02:322022-03-18 21:44:28
CHANGED{0AB869AE-42B7-44e9-A4EA-88DCE6F18FE9}
Diagram notes
The subtransient salient pole simplified direct-axis type is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientSimplifiedDirectAxis and .rotorKind = salientPole. It is a simplified version of a subtransient salient pole type with no damper circuit on the <i>d</i>-axis. This simplification contributes to a reduction in computational effort by reducing the order of the differential equation system. The <i>q</i>-axis has only one equivalent rotor winding. Magnetic coupling between the direct- and quadrature- axes is ignored. Parameter details: <ol> <li>The effects of speed variation are neglected.</li> <li>No armature resistance.</li> <li>No saturation effects.</li> <li>No subtransient saliency.</li> <li>Direct-axis with field circuit only, no equivalent damper circuit. Approximation: <i>X'd</i> = <i>X''d</i>.</li> <li>Quadrature-axis with only one equivalent damper circuit, which is labelled as subtransient (<i>X''q</i>), <i>X''q</i> =<i>X'q</i>.</li> <li>For generators and motors the following input parameters are needed: <i>Xd, X'd, T'do</i> and <i>Xq, X''q, T''qo</i>.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 09:02:322022-03-18 21:44:28
Diagram 'SubtransientSalientPoleSimplifiedDirectAxis' has no other changes. The shows its notes and every changed property.
▶▦SubtransientTypeFi
Diagram notes
The subtransient type F is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientTypeF. This model is the WECC type F model with uniform inductance rotor modelling; shaft speed effects are neglected. It has a similar level of detail to the subtransient round rotor type but permits subtransient saliency (<i>X''q </i>not = <i>X''d</i>) and models saturation differently. The subtransient round rotor type can usually be substituted without significant loss of accuracy. Saturation is modelled in both the direct- and quadrature- axes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 06:58:342022-03-18 21:45:06
CHANGED{407ECF1A-A778-4d43-8CB6-A33DBDC0D26B}
Diagram notes
The subtransient type F is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientTypeF. This model is the WECC type F model with uniform inductance rotor modelling; shaft speed effects are neglected. It has a similar level of detail to the subtransient round rotor type but permits subtransient saliency (<i>X''q </i>not = <i>X''d</i>) and models saturation differently. The subtransient round rotor type can usually be substituted without significant loss of accuracy. Saturation is modelled in both the direct- and quadrature- axes.
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 06:58:342022-03-18 21:45:06
Diagram 'SubtransientTypeF' has no other changes. The shows its notes and every changed property.
▶▦SubtransientTypeJi
Diagram notes
The subtransient type J is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientTypeJ. This model is the WECC type J model with uniform inductance ratios rotor modelling with modified saturation model; shaft speed effects are neglected. This model is the same as subtransient type F but includes the effect of generator loading on saturation. With the usage of the saturation constant (<i>Ks</i>) parameter, it allows reproduction of the measured "V curves" over the whole range of reactive power, particularly on some hydro (salient pole) machines. Saturation is modelled in both the direct- and quadrature- axes.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 07:04:422022-03-18 21:45:00
CHANGED{9BE00E90-A37A-493d-BF40-8871FFFDF99C}
Diagram notes
The subtransient type J is modelled using one of the concrete child classes of the SynchronousMachineDetailed class. If the SynchronousMachineTimeConstantReactance class is used, .modelType = subtransientTypeJ. This model is the WECC type J model with uniform inductance ratios rotor modelling with modified saturation model; shaft speed effects are neglected. This model is the same as subtransient type F but includes the effect of generator loading on saturation. With the usage of the saturation constant (<i>Ks</i>) parameter, it allows reproduction of the measured "V curves" over the whole range of reactive power, particularly on some hydro (salient pole) machines. Saturation is modelled in both the direct- and quadrature- axes.
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 07:04:422022-03-18 21:45:00
Diagram 'SubtransientTypeJ' has no other changes. The shows its notes and every changed property.
▶▦SynchronousEquivalentCircuiti
Diagram notes
In each axis, the branches represent the stator leakage reactance (<i>Xl</i>) and resistance (<i>Rs</i>), the magnetizing reactance (<i>Xad, Xaq</i>), the physical field winding (<i>Rfd, Xfd</i>) on the rotor, and equivalent windings for eddy current flow in the rotor iron.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-06-11 09:10:512022-03-18 21:44:18
CHANGED{08ED8281-5888-4894-8894-93B0D735B450}
Diagram notes
In each axis, the branches represent the stator leakage reactance (<i>Xl</i>) and resistance (<i>Rs</i>), the magnetizing reactance (<i>Xad, Xaq</i>), the physical field winding (<i>Rfd, Xfd</i>) on the rotor, and equivalent windings for eddy current flow in the rotor iron.
▤Metadata
BaselineDestination
ModifiedDate2017-06-11 09:10:512022-03-18 21:44:18
Diagram 'SynchronousEquivalentCircuit' has no other changes. The shows its notes and every changed property.
▶▦SynchronousGeneratorInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for a synchronous generator.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-09-15 22:01:512022-03-18 21:41:43
CHANGED{94863F11-DB5A-4e77-A2B2-A277A59E5089}
Diagram notes
This diagram illustrates the inputs and outputs for a synchronous generator.
▤Metadata
BaselineDestination
ModifiedDate2013-09-15 22:01:512022-03-18 21:41:43
Diagram 'SynchronousGeneratorInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶▦SynchronousGeneratorMechanicalEquationi
Diagram notes
The mechanical equations for all the variations of the synchronous generator model are the same and can be represented by the SynchronousGeneratorMechanicalEquation block diagram. Parameter details: <ol> <li>All variables are PU on generator MVA base except angle, which is in radians.</li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> <li>The input to the mechanical equations can be either <i>Pm</i> or <i>Tm</i> depending on the application program. Application programs using <i>Pm</i> as the input with the damping feedback subtracted from <i>Pm</i> will need to increase <i>D</i> by 1 as shown. In that case, the damping feedback to the torque summing point is not used.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:42:062022-03-18 21:42:23
CHANGED{F4B81F54-0CAA-43ef-86E5-CC1C71090886}
Diagram notes
The mechanical equations for all the variations of the synchronous generator model are the same and can be represented by the SynchronousGeneratorMechanicalEquation block diagram. Parameter details: <ol> <li>All variables are PU on generator MVA base except angle, which is in radians.</li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> <li>The input to the mechanical equations can be either <i>Pm</i> or <i>Tm</i> depending on the application program. Application programs using <i>Pm</i> as the input with the damping feedback subtracted from <i>Pm</i> will need to increase <i>D</i> by 1 as shown. In that case, the damping feedback to the torque summing point is not used.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:42:062022-03-18 21:42:23
Diagram 'SynchronousGeneratorMechanicalEquation' has no other changes. The shows its notes and every changed property.
▶▦SynchronousGeneratorPhasori
Diagram notes
Diagram details: <ol> <li>The definition of <i>d</i>- and <i>q</i>-axis variables is based on the SynchronousGeneratorPhasor diagram (counter-clockwise rotation) for the case of an overexcited generator (generating reactive power).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-02 21:11:332022-03-18 21:42:48
CHANGED{2F987EEE-14E4-45df-888F-5871CA580BE3}
Diagram notes
Diagram details: <ol> <li>The definition of <i>d</i>- and <i>q</i>-axis variables is based on the SynchronousGeneratorPhasor diagram (counter-clockwise rotation) for the case of an overexcited generator (generating reactive power).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-02 21:11:332022-03-18 21:42:48
Diagram 'SynchronousGeneratorPhasor' has no other changes. The shows its notes and every changed property.
▶▦SynchronousMachineDynamicsi
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the synchronous machine dynamics model. An association between the SynchronousMachineDynamics class and the SynchronousMachine class provides a means for relating the dynamics model to the static model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-07-20 19:30:132022-03-18 21:42:00
CHANGED{54E9C659-8B6C-4948-A2ED-1F2B84C0A17C}
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the synchronous machine dynamics model. An association between the SynchronousMachineDynamics class and the SynchronousMachine class provides a means for relating the dynamics model to the static model.
▤Metadata
BaselineDestination
ModifiedDate2017-07-20 19:30:132022-03-18 21:42:00
▦Diagram
addedchangedmoved or resized
Baseline
SynchronousMachineDynamics (baseline)
Destination
SynchronousMachineDynamics (destination)
Connectors 1 rerouted · 1 labels movedhover a connector to outline the elements it joins
reroutedRotatingMachineDynamics – DynamicsFunctionBlock
labels movedSynchronousMachineDynamics – SynchronousMachine
▶▦SynchronousMachineSaturationParametersi
Diagram notes
This diagram shows the synchronous machine saturation parameters. Parameter details: <ol> <li>The quantity <i>OA</i><i><sub>i</sub></i> in amperes is normally called Ifag (which means field current at rated voltage, open circuit on the air gap (no saturation) line). <i>OB</i><i><sub>i</sub></i> in amperes isnormally called Ifn (which means field current at rated voltage with no load on the machine).</li> <li>Saturation factors for generators are given by RotatingMachineDynamics.saturationFactor and RotatingMachineDynamics.saturationFactor120. </li> <li>For exciters, the values are given in the attributes for each standard excitation system model.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:42:09
CHANGED{CF13A3D0-AB58-49b7-82DC-DA72A7F5D53D}
Diagram notes
This diagram shows the synchronous machine saturation parameters. Parameter details: <ol> <li>The quantity <i>OA</i><i><sub>i</sub></i> in amperes is normally called Ifag (which means field current at rated voltage, open circuit on the air gap (no saturation) line). <i>OB</i><i><sub>i</sub></i> in amperes isnormally called Ifn (which means field current at rated voltage with no load on the machine).</li> <li>Saturation factors for generators are given by RotatingMachineDynamics.saturationFactor and RotatingMachineDynamics.saturationFactor120. </li> <li>For exciters, the values are given in the attributes for each standard excitation system model.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:42:09
Diagram 'SynchronousMachineSaturationParameters' has no other changes. The shows its notes and every changed property.
▶▦SynchronousMotorInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for a synchronous motor.
Diagram metadata — changes
BaselineDestination
ModifiedDate2012-09-02 12:10:292022-03-18 21:41:51
CHANGED{371B02E6-1F58-432a-B212-4BD4D15215F2}
Diagram notes
This diagram illustrates the inputs and outputs for a synchronous motor.
▤Metadata
BaselineDestination
ModifiedDate2012-09-02 12:10:292022-03-18 21:41:51
Diagram 'SynchronousMotorInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶▦SynchronousMotorMechanicalEquationi
Diagram notes
The mechanical equations for all variations of the synchronous motor model are the same and can be represented by the SynchronousMotorMechanicalEquation diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:42:372022-03-18 21:42:35
CHANGED{88E02CC8-D4F0-4e2e-994C-671A0D647CE4}
Diagram notes
The mechanical equations for all variations of the synchronous motor model are the same and can be represented by the SynchronousMotorMechanicalEquation diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:42:372022-03-18 21:42:35
Diagram 'SynchronousMotorMechanicalEquation' has no other changes. The shows its notes and every changed property.
▶▦SynchronousMotorPhasori
Diagram notes
Diagram details: <ol> <li>The definition of <i>d</i>- and <i>q</i>-axis variables is based on the SynchronousMotorPhasor diagram (counter-clockwise rotation) for the case of a motor consuming active power and overexcited (generating reactive power).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-24 15:41:152022-03-18 21:42:57
CHANGED{4AA54732-4338-405e-854B-1FE56956C9FE}
Diagram notes
Diagram details: <ol> <li>The definition of <i>d</i>- and <i>q</i>-axis variables is based on the SynchronousMotorPhasor diagram (counter-clockwise rotation) for the case of a motor consuming active power and overexcited (generating reactive power).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-24 15:41:152022-03-18 21:42:57
Diagram 'SynchronousMotorPhasor' has no other changes. The shows its notes and every changed property.
▶AsynchronousMachineDynamicsi
Package notes (destination, redlined)
An asynchronous machine model represents a (induction) generator or motor with no external connection to the rotor windings, e.g. a squirrel-cage induction machine. The interconnection with the electrical network equations can differ among simulation tools. The program only needs to know the terminal to which this asynchronous machine is connected in order to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models. The asynchronous machine model is used to model wind generators type 1 and type 2. For these, normal practice is to include the rotor flux transients and neglect the stator flux transients.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/AsynchronousMachineDynamics/1.0
version(no tag)1.0.0
CHANGED{5D284657-A8B5-4b22-A1BE-60220021422B}
Package notes (destination, redlined)
An asynchronous machine model represents a (induction) generator or motor with no external connection to the rotor windings, e.g. a squirrel-cage induction machine. The interconnection with the electrical network equations can differ among simulation tools. The program only needs to know the terminal to which this asynchronous machine is connected in order to establish the correct interconnection. The interconnection with the motor’s equipment could also differ due to input and output signals required by standard models. The asynchronous machine model is used to model wind generators type 1 and type 2. For these, normal practice is to include the rotor flux transients and neglect the stator flux transients.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/AsynchronousMachineDynamics/1.0
version(no tag)1.0.0
Package 'AsynchronousMachineDynamics' has no changes to the 3 classes it contains.
Changed diagrams (6)
▶▦AsynchronousEquivalentCircuiti
Diagram notes
In each axis, the branches represent the stator leakage reactance (<i>Xl</i>) and resistance (<i>Rs</i>), the magnetizing reactance (<i>Xm</i>), and the resistance and leakage reactance of equivalent windings (<i>Rr1, Xlr1,</i> etc.) on the rotor.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-11-23 20:20:162022-03-18 21:46:41
CHANGED{1AB02177-CD45-45be-8319-8D675849DBB4}
Diagram notes
In each axis, the branches represent the stator leakage reactance (<i>Xl</i>) and resistance (<i>Rs</i>), the magnetizing reactance (<i>Xm</i>), and the resistance and leakage reactance of equivalent windings (<i>Rr1, Xlr1,</i> etc.) on the rotor.
▤Metadata
BaselineDestination
ModifiedDate2017-11-23 20:20:162022-03-18 21:46:41
Diagram 'AsynchronousEquivalentCircuit' has no other changes. The shows its notes and every changed property.
▶▦AsynchronousGeneratorInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for an asynchronous generator.
Diagram metadata — changes
BaselineDestination
ModifiedDate2012-09-12 14:04:082022-03-18 21:47:15
CHANGED{508BEF21-72E7-40d7-ADEB-9B16B392F9B4}
Diagram notes
This diagram illustrates the inputs and outputs for an asynchronous generator.
▤Metadata
BaselineDestination
ModifiedDate2012-09-12 14:04:082022-03-18 21:47:15
Diagram 'AsynchronousGeneratorInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶▦AsynchronousGeneratorMechanicalEquationi
Diagram notes
The mechanical equations for all the variations of the asynchronous generator model are the same and can be represented by the AsynchronousGeneratorMechanicalEquation block diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i><i> </i>is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:46:072022-03-18 21:46:55
CHANGED{CEB8A696-CBC8-460a-9858-400F2662F00C}
Diagram notes
The mechanical equations for all the variations of the asynchronous generator model are the same and can be represented by the AsynchronousGeneratorMechanicalEquation block diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i><i> </i>is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:46:072022-03-18 21:46:55
Diagram 'AsynchronousGeneratorMechanicalEquation' has no other changes. The shows its notes and every changed property.
▶▦AsynchronousMachineDynamicsi
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the asynchronous machine dynamics model. An association between the AsynchronousMachineDynamics class and the AsynchronousMachine class provides a means for relating the dynamics model to the static model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-07-20 19:30:132022-03-18 21:47:02
CHANGED{25AB5834-2B99-4846-9C8F-855D6A80D650}
Diagram notes
This diagram shows static power system model classes and dynamics model classes related to the asynchronous machine dynamics model. An association between the AsynchronousMachineDynamics class and the AsynchronousMachine class provides a means for relating the dynamics model to the static model.
▤Metadata
BaselineDestination
ModifiedDate2017-07-20 19:30:132022-03-18 21:47:02
▦Diagram
addedchanged
Baseline
AsynchronousMachineDynamics (baseline)
Destination
AsynchronousMachineDynamics (destination)
Connectors 1 labels movedhover a connector to outline the elements it joins
labels movedAsynchronousMachineDynamics – AsynchronousMachine
▶▦AsynchronousMotorInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for an asynchronous motor.
Diagram metadata — changes
BaselineDestination
ModifiedDate2012-09-12 14:04:082022-03-18 21:47:09
CHANGED{FD6932D3-3F95-433e-8786-2706E27F18F0}
Diagram notes
This diagram illustrates the inputs and outputs for an asynchronous motor.
▤Metadata
BaselineDestination
ModifiedDate2012-09-12 14:04:082022-03-18 21:47:09
Diagram 'AsynchronousMotorInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶▦AsynchronousMotorMechanicalEquationi
Diagram notes
The mechanical equations for all variations of the asynchronous motor model are the same and can be represented by the AsynchronousMotorMechanicalEquation diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:46:542022-03-18 21:46:48
CHANGED{5DA69A8A-0553-402c-AF5F-BBC9B60692FD}
Diagram notes
The mechanical equations for all variations of the asynchronous motor model are the same and can be represented by the AsynchronousMotorMechanicalEquation diagram. Parameter details: <ol> <li>All variables are PU on motor MVA base except angle, which is in radians. </li> <li><i>omega</i><i><sub>0</sub></i> is the system synchronous frequency in radians per s. <i>omega</i><i><sub>ref</sub></i> is the PU system frequency (or isolated area frequency), which can be constant at the initial frequency or vary during a simulation depending on the application program.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:46:542022-03-18 21:46:48
Diagram 'AsynchronousMotorMechanicalEquation' has no other changes. The shows its notes and every changed property.
▶TurbineGovernorDynamicsi
Package notes (destination, redlined)
The turbine-governor model is linked to one or two synchronous generators and determines the shaft mechanical power (<i>Pm</i>) or torque (<i>Tm</i>) for the generator model. Unlike IEEE standard models for other function blocks, the three IEEE turbine-governor standard models (GovHydroIEEE0, GovHydroIEEE2, and GovSteamIEEE1) are documented in IEEE Transactions, not in IEEE standards. For that reason, diagrams are supplied for those models. A 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, provides updated information on a variety of models including IEEE, vendor and reliability authority models. Fully incorporating the results of that report into the CIM dynamics model is a future effort.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/TurbineGovernorDynamics/1.0
version(no tag)1.0.0
CHANGED{40DA7439-D5DD-4608-85C0-87CF5444B24E}
Package notes (destination, redlined)
The turbine-governor model is linked to one or two synchronous generators and determines the shaft mechanical power (<i>Pm</i>) or torque (<i>Tm</i>) for the generator model. Unlike IEEE standard models for other function blocks, the three IEEE turbine-governor standard models (GovHydroIEEE0, GovHydroIEEE2, and GovSteamIEEE1) are documented in IEEE Transactions, not in IEEE standards. For that reason, diagrams are supplied for those models. A 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, provides updated information on a variety of models including IEEE, vendor and reliability authority models. Fully incorporating the results of that report into the CIM dynamics model is a future effort.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/TurbineGovernorDynamics/1.0
version(no tag)1.0.0
Added classes (20)
▶⚙CombinedCycleGasTurbineDynamicsi
Class notes
Gas turbines used for combined cycle power plants.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameCombinedCycleGasTurbineDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{10231D92-E5F5-4f90-95C7-1AFD24ADF810}
Class notes
Gas turbines used for combined cycle power plants.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameCombinedCycleGasTurbineDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovCIGREGT
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEGT1
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
DestinationCombinedCycleGasTurbineDynamics role CombinedCycleGasTurbineDynamics [1..*] → SteamTurbineGeneratorDynamics role SteamTurbineGeneratorDynamics [1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality1..*
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleCombinedCycleGasTurbineDynamics
RoleNoteThe gas turbine dynamics model part of a combined cycle power plant.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSteamTurbineGeneratorDynamics
RoleNoteThe steam turbine and a heat-recovery steam generator connected to this gas turbine of a combined cycle power plant.
Scopepublic
TargetScopeinstance
▶⚙GovCIGREGTi
Class notes
CIGRE gas turbine model. The major difference between this model and GovCT1 is the inclusion of a second order transfer function to represent gas turbine dynamics, if necessary, and a polynomial fit of the maximum power output limit as a function of ambient air-temperature and shaft speed with a simple user-defined look-up table. Reference: IEEE PES-TR1, 3.1.2.4.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovCIGREGT
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{7FBAFA72-1EB6-4fac-9545-2F8E8533FC16}
Class notes
CIGRE gas turbine model. The major difference between this model and GovCT1 is the inclusion of a second order transfer function to represent gas turbine dynamics, if necessary, and a polynomial fit of the maximum power output limit as a function of ambient air-temperature and shaft speed with a simple user-defined look-up table. Reference: IEEE PES-TR1, 3.1.2.4.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovCIGREGT
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
aseti{6D81773A-8F63-4845-ACC2-C99B2A0C77EA}show detailsdid not existPU [0..1]Acceleration control setpoint (Aset). Typical value = 0.
Attribute notes
Acceleration control setpoint (Aset). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameaset
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
dbdi{FC04EC28-6057-4ac7-9D02-29ACE6B57CF9}show detailsdid not existPU [0..1]Speed governor deadband (dbd). Typical value = 0.
Attribute notes
Speed governor deadband (dbd). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedbd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
erri{D1E3C02D-0050-44cf-A000-B753ADC0F159}show detailsdid not existPU [0..1]Maximum Speed governor error (err). Typical value = 1.
Attribute notes
Maximum Speed governor error (err). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameerr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
fmi{C97B5F65-1FE1-4539-A703-B14743BB9280}show detailsdid not existBoolean [0..1]Speed sensitivity selector (Fm). True means Fm=1. False means the speed signal is selected. Typical value = true.
Attribute notes
Speed sensitivity selector (Fm). True means Fm=1. False means the speed signal is selected. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefm
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
fxi{6016321F-E07A-4306-82AF-30EF214EC69B}show detailsdid not existString [0..1]User-defined lookup table (y=F(x)).
Attribute notes
User-defined lookup table (y=F(x)).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefx
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
kdgi{9D05AD4D-FB63-4565-B7A1-D8E00D184338}show detailsdid not existPU [0..1]Governor derivative gain (Kdg). Typical value = 1.
Attribute notes
Governor derivative gain (Kdg). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{6DD7155C-CBF6-459e-9413-7BE6E6B777A9}show detailsdid not existPU [0..1]Acceleration control integral gain (Kia). Typical value = 10.
Attribute notes
Acceleration control integral gain (Kia). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kigi{EA320441-462F-4bfc-913C-0CFD792F5AE1}show detailsdid not existPU [0..1]Governor integral gain (Kig). Typical value = 2.
Attribute notes
Governor integral gain (Kig). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekig
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kimwi{D18B968A-1A00-4e78-918A-0D95CB8311E1}show detailsdid not existPU [0..1]Power controller integral gain (Kimw). Typical value = 0.
Attribute notes
Power controller integral gain (Kimw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekimw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiti{29564621-8EBD-4081-B5D6-1191EBDD0FF0}show detailsdid not existPU [0..1]Load limiter integral gain (Kit). Typical value = 0,2.
Attribute notes
Load limiter integral gain (Kit). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekit
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{156F9E4D-388B-4c09-833B-4A7F5DD8E54F}show detailsdid not existPU [0..1]Acceleration control proportional gain (Kpa). Typical value = 0.
Attribute notes
Acceleration control proportional gain (Kpa). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpgi{77F874C0-D282-4494-8194-BEDB48D838E7}show detailsdid not existPU [0..1]Governor proportional gain (Kpg). Typical value = 10.
Attribute notes
Governor proportional gain (Kpg). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpmwi{4B8BD671-6051-4f10-A4C2-D5A30752B8D8}show detailsdid not existPU [0..1]Power controller proportional gain (Kpmw). Typical value = 0.
Attribute notes
Power controller proportional gain (Kpmw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpmw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpti{0A7DDFB1-C83E-464c-A836-B36FC7D6025F}show detailsdid not existPU [0..1]Load limiter proportional gain (Kpt). Typical value = 1.
Attribute notes
Load limiter proportional gain (Kpt). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kti{EF36E889-772C-481c-B124-6B6B68733EA7}show detailsdid not existPU [0..1]Turbine gain (Kt). Typical value = 1,5.
Attribute notes
Turbine gain (Kt). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
maxi{E428C30A-351D-49f6-9918-A269F98777B5}show detailsdid not existPU [0..1]Governor maximum output (Max). Typical value = 1,05.
Attribute notes
Governor maximum output (Max). Typical value = 1,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
mini{A47E0692-35BF-4093-A368-DF8B666D48CB}show detailsdid not existPU [0..1]Governor minimum output (Min). Typical value = 0.
Attribute notes
Governor minimum output (Min). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rfmaxi{C0D2F642-CF40-4988-9499-22D5A8E01597}show detailsdid not existPU [0..1]Power controller maximum output (Rfmax). Typical value = 0,1.
Attribute notes
Power controller maximum output (Rfmax). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerfmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rfmini{004556DE-5345-4306-9B25-34A9A26893FA}show detailsdid not existPU [0..1]Power controller minimum output (Rfmin). Typical value = -0,1.
Attribute notes
Power controller minimum output (Rfmin). Typical value = -0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerfmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{71684969-7802-417c-B03D-E4A1BB7D7B21}show detailsdid not existPU [0..1]Permanent droop on electrical power (Rp). Typical value = 0,04.
Attribute notes
Permanent droop on electrical power (Rp). Typical value = 0,04.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rvi{D71DEAF2-EFA9-453a-ACED-0EF31492CD2D}show detailsdid not existPU [0..1]Permanent droop on valve position (Rv). Typical value = 0.
Attribute notes
Permanent droop on valve position (Rv). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerv
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{FF89C2E3-EDDA-4017-AF5A-3E8596589FBD}show detailsdid not existSeconds [0..1]Acc. control differentiator time constant (Ta) (>=0). Typical value = 0,1.
Attribute notes
Acc. control differentiator time constant (Ta) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{A13F6274-0132-4c25-A53C-2C5724EBBF76}show detailsdid not existSeconds [0..1]Temperature detection lag time constant (Td) (>=0). Typical value = 15.
Attribute notes
Temperature detection lag time constant (Td) (>=0). Typical value = 15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdgi{E00800FE-7BEC-4f9f-9262-FBA1D72EF7D1}show detailsdid not existSeconds [0..1]Governor derivative controller time constant (Tdg) (>=0). Typical value = 0,1.
Attribute notes
Governor derivative controller time constant (Tdg) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tlimiti{A61E0BAD-3043-4dfc-9FF8-543DD33046CA}show detailsdid not existPU [0..1]Load limiter reference value (Tlimit). Typical value = 0,9167.
Attribute notes
Load limiter reference value (Tlimit). Typical value = 0,9167.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametlimit
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tni{1DEF481E-5621-439e-AF9B-174D47455F89}show detailsdid not existSeconds [0..1]Temperature detection lead time constant (Tn) (>=0). Typical value = 10.
Attribute notes
Temperature detection lead time constant (Tn) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametn
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{14FA3E28-C3AC-4299-A0E4-87FB9DB5F99E}show detailsdid not existSeconds [0..1]Electrical power transducer time constant (Tp) (>=0). Typical value = 5.
Attribute notes
Electrical power transducer time constant (Tp) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{F054DCF8-CD74-4485-829E-E42F9C0A42DB}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
ttd1i{0EA3618C-7943-4385-A09D-C693E1A2F862}show detailsdid not existSeconds [0..1]Turbine lag time constant (Ttd1) (>=0). Typical value = 0,5.
Attribute notes
Turbine lag time constant (Ttd1) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettd1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttd2i{72DF1919-5601-4882-ABD1-C7B94444F21D}show detailsdid not existSeconds [0..1]Turbine lag time constant (Ttd2) (>=0). Typical value = 0.
Attribute notes
Turbine lag time constant (Ttd2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettd2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tthcpi{872487E4-3E4B-4d55-8E44-C50F58A8A6C0}show detailsdid not existSeconds [0..1]Thermocouple time constant (Tthcp) (>=0). Typical value = 3.
Attribute notes
Thermocouple time constant (Tthcp) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametthcp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttn1i{833B0BCA-B659-4a99-BDB1-8E26D8B1805B}show detailsdid not existSeconds [0..1]Turbine lead time constant (Ttn1) (>=0). Typical value = 0.
Attribute notes
Turbine lead time constant (Ttn1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettn1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttn2i{94E71A9D-53FC-442d-BD24-7D27790BA459}show detailsdid not existSeconds [0..1]Turbine lead time constant (Ttn2) (>=0). Typical value = 0.
Attribute notes
Turbine lead time constant (Ttn2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettn2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tvi{A5CB1EB2-AD0D-4e1d-A391-CC8CC8D8EF6E}show detailsdid not existSeconds [0..1]Actuator time constant (Tv) (>=0). Typical value = 0,5.
Attribute notes
Actuator time constant (Tv) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametv
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vmaxi{A9C76B00-0EF5-4fa6-8CD1-C8496622F432}show detailsdid not existPU [0..1]Maximum valve position (Vmax). Typical value = 1,05.
Attribute notes
Maximum valve position (Vmax). Typical value = 1,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmini{1634F28B-067C-49db-8737-967D2F383D21}show detailsdid not existPU [0..1]Minimum valve position (Vmin). Typical value = 0.
Attribute notes
Minimum valve position (Vmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
wfoi{2A4D1650-3F34-47bb-BDCC-AB5B3E8402D8}show detailsdid not existPU [0..1]No load fuel flow (Wfo). Typical value = 0,25.
Attribute notes
No load fuel flow (Wfo). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namewfo
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovCIGREGT
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEGT1i
Class notes
Simplified gas turbine model. Reference: IEEE PES-TR1, 3.1.2.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEGT1
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0FF5C988-7501-4be8-BD24-4AB6D823CFAF}
Class notes
Simplified gas turbine model. Reference: IEEE PES-TR1, 3.1.2.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEGT1
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
di{FF4257CA-47EB-457e-9248-04FCCB431C49}show detailsdid not existFloat [0..1]Inverse of permanent droop (D). Typical value = 25.
Attribute notes
Inverse of permanent droop (D). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Named
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
dbdi{356FEA32-3D57-4311-A47F-9D50C444C8A6}show detailsdid not existPU [0..1]Speed governor deadband (dbd). Typical value = 0.
Attribute notes
Speed governor deadband (dbd). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedbd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
fxi{4E1877DD-8882-4222-8337-CA8B20C3CC1B}show detailsdid not existString [0..1]User-defined lookup table (y=F(x)).
Attribute notes
User-defined lookup table (y=F(x)).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefx
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
ideli{4ECE60C7-8622-4987-9690-CA21421034E4}show detailsdid not existPU [0..1]Speed deviation for governor error limit change (idel). Typical value = 1.
Attribute notes
Speed deviation for governor error limit change (idel). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameidel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdgi{D41B5501-4A22-4196-9E35-A4248433D52C}show detailsdid not existPU [0..1]Governor derivative gain (Kdg). Typical value = 0,1.
Attribute notes
Governor derivative gain (Kdg). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kigi{6E8EA126-C71C-479c-BCEA-56BD303105BE}show detailsdid not existPU [0..1]Governor integral gain (Kig). Typical value = 0,1.
Attribute notes
Governor integral gain (Kig). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekig
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kimwi{66F145A0-224F-4db4-B9FE-EACD0AA83362}show detailsdid not existPU [0..1]Power controller integral gain (Kimw). Typical value = 0.
Attribute notes
Power controller integral gain (Kimw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekimw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiti{9C7FF4A9-2D70-4783-A278-9604572E443F}show detailsdid not existPU [0..1]Load limiter integral gain (Kit). Typical value = 0,67.
Attribute notes
Load limiter integral gain (Kit). Typical value = 0,67.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekit
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpgi{9FC46C3B-C9AA-49df-AB7E-66DB4E4AD631}show detailsdid not existPU [0..1]Governor proportional gain (Kpg). Typical value = 0,5.
Attribute notes
Governor proportional gain (Kpg). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpmwi{D368282F-5793-4f8e-8F8A-F231585EC10F}show detailsdid not existPU [0..1]Power controller proportional gain (Kpmw). Typical value = 0.
Attribute notes
Power controller proportional gain (Kpmw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpmw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpti{3BFC89B9-1F1F-459a-AC2F-A377F61C64DC}show detailsdid not existPU [0..1]Load limiter proportional gain (Kpt). Typical value = 2.
Attribute notes
Load limiter proportional gain (Kpt). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kti{BAA343B0-1791-4367-ADC7-28553A32D59E}show detailsdid not existPU [0..1]Turbine gain (Kt). Typical value = 1,5.
Attribute notes
Turbine gain (Kt). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
lim1i{75CF8273-1D26-4f07-8330-6CF8BC814097}show detailsdid not existPU [0..1]Speed governor error first limit (lim1). Typical value = 10.
Attribute notes
Speed governor error first limit (lim1). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namelim1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
lim2i{D5E4B98E-3E99-4031-B2A6-D78350447B50}show detailsdid not existPU [0..1]Speed governor error second limit (lim2). Typical value = 10.
Attribute notes
Speed governor error second limit (lim2). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namelim2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
maxi{4A9D6F22-C180-40c0-9541-9EAF9D02DFDF}show detailsdid not existPU [0..1]Governor maximum output (Max). Typical value = 1,05.
Attribute notes
Governor maximum output (Max). Typical value = 1,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
mini{A41A4E6D-F2EA-45a7-829D-12210B94BC99}show detailsdid not existPU [0..1]Governor minimum output (Min). Typical value = 0.
Attribute notes
Governor minimum output (Min). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rfmaxi{2B323C18-BA28-4046-8172-A0E263DAD342}show detailsdid not existPU [0..1]Power controller maximum output (Rfmax). Typical value = 0,1.
Attribute notes
Power controller maximum output (Rfmax). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerfmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rfmini{43468398-EF90-4f1c-9547-77D6EFE17B3B}show detailsdid not existPU [0..1]Power controller minimum output (Rfmin). Typical value = -0,1.
Attribute notes
Power controller minimum output (Rfmin). Typical value = -0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerfmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{1A3A4031-BEE3-4e56-88CB-81596F77CCA5}show detailsdid not existSeconds [0..1]Temperature detection lag time constant (Td) (>=0). Typical value = 5.
Attribute notes
Temperature detection lag time constant (Td) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdgi{8B372EBE-BCB8-40d2-963D-D4B72D772B54}show detailsdid not existSeconds [0..1]Governor derivative controller time constant (Tdg) (>=0). Typical value = 0,1.
Attribute notes
Governor derivative controller time constant (Tdg) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tlimiti{B52AF3C4-70D4-4476-B220-6BB774007E27}show detailsdid not existPU [0..1]Load limiter reference value (Tlimit). Typical value = 0,9167.
Attribute notes
Load limiter reference value (Tlimit). Typical value = 0,9167.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametlimit
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tni{1AF40BF6-C7CD-4746-B1B2-83A2BD6218B9}show detailsdid not existSeconds [0..1]Temperature detection lead time constant (Tn) (>=0). Typical value = 4.
Attribute notes
Temperature detection lead time constant (Tn) (>=0). Typical value = 4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametn
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{A89ED385-B95D-4811-8693-D983522E8A84}show detailsdid not existSeconds [0..1]Electrical power transducer time constant (Tp) (>=0). Typical value = 5.
Attribute notes
Electrical power transducer time constant (Tp) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{D273AE17-369F-40b8-B557-18D1C3358230}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of SG) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of SG) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
ttd1i{175B4023-AACD-4983-82CD-257C41834AB1}show detailsdid not existSeconds [0..1]Turbine lag time constant (Ttd1) (>=0). Typical value = 0,5.
Attribute notes
Turbine lag time constant (Ttd1) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettd1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttd2i{C558A042-78A1-4c3b-8D15-C48F1C3EB1E6}show detailsdid not existSeconds [0..1]Turbine lag time constant (Ttd2) (>=0). Typical value = 0.
Attribute notes
Turbine lag time constant (Ttd2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettd2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tthcpi{10187F95-DC4D-4673-84B3-1C3B624547D0}show detailsdid not existSeconds [0..1]Thermocouple time constant (Tthcp) (>=0). Typical value = 3.
Attribute notes
Thermocouple time constant (Tthcp) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametthcp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttn1i{E2144D6F-B302-4d97-B724-291FE63E392A}show detailsdid not existSeconds [0..1]Turbine lead time constant (Ttn1) (>=0). Typical value = 0.
Attribute notes
Turbine lead time constant (Ttn1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettn1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
ttn2i{24A7E712-AF52-46b4-86D9-7B26A74A107B}show detailsdid not existSeconds [0..1]Turbine lead time constant (Ttn2) (>=0). Typical value = 0.
Attribute notes
Turbine lead time constant (Ttn2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namettn2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tvi{72E3883A-8961-4f91-BD19-3C7D57DB4F46}show detailsdid not existSeconds [0..1]Actuator time constant (Tv) (>=0). Typical value = 0,5.
Attribute notes
Actuator time constant (Tv) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametv
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vmaxi{EE53CEA8-C1E8-4f40-A926-A71AA7290EA7}show detailsdid not existPU [0..1]Maximum valve position (Vmax). Typical value = 1,05.
Attribute notes
Maximum valve position (Vmax). Typical value = 1,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmini{3E395CF8-6268-43ca-ADE3-24D097F6D000}show detailsdid not existPU [0..1]Minimum valve position (Vmin). Typical value = 0.
Attribute notes
Minimum valve position (Vmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
wfoi{E49FF9AB-2613-4ba3-90AE-6F7AC7D00A7D}show detailsdid not existPU [0..1]No load fuel flow (Wfo). Typical value = 0,25.
Attribute notes
No load fuel flow (Wfo). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namewfo
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEGT1
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEHydroDDi
Class notes
Double-derivative hydro governor. Reference: IEEE PES-TR1, 4.2, Figure 4-5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroDD
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{85FD6D0B-0448-4199-9DCA-1B20537DA518}
Class notes
Double-derivative hydro governor. Reference: IEEE PES-TR1, 4.2, Figure 4-5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroDD
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
db1i{C11796F7-3369-4782-AEC4-616B053CB1F3}show detailsdid not existPU [0..1]Dead-band width (db1). Typical value = 0.
Attribute notes
Dead-band width (db1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db2i{FEF3B9BD-C1CE-49e8-8455-514DAB399133}show detailsdid not existPU [0..1]Unintentional dead-band (db2). Typical value = 0.
Attribute notes
Unintentional dead-band (db2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
flagi{87C70AE5-D32D-452b-8C1E-D40FD129F34F}show detailsdid not existBoolean [0..1]Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute notes
Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameflag
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
gmaxi{B090C453-DF4E-4d8b-BFFF-1BF0A0C98F60}show detailsdid not existPU [0..1]Maximum gate opening (Gmax). Typical value = 1.
Attribute notes
Maximum gate opening (Gmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gmini{9C3170FD-D9CD-4064-BA6F-BF95D7F1F170}show detailsdid not existPU [0..1]Minimum gate opening (Gmin). Typical value = 0.
Attribute notes
Minimum gate opening (Gmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{D1C1B5D9-682F-4b2e-86FE-4B5BAC86976C}show detailsdid not existPU [0..1]Derivative gain (Kd). Typical value = 5.
Attribute notes
Derivative gain (Kd). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{A64B80BC-D382-4f74-A457-F8C969EEA8E1}show detailsdid not existPU [0..1]Integral gain (Ki). Typical value = 0,5.
Attribute notes
Integral gain (Ki). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{86E4EB0D-73CF-48d7-ADEF-79D9B05FB6CA}show detailsdid not existPU [0..1]Maximum gate opening (Pmax). Typical value = 1.
Attribute notes
Maximum gate opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{69C262D3-5C15-4df6-9C65-D913DF2F83F7}show detailsdid not existPU [0..1]Minimum gate opening (Pmin). Typical value = 0.
Attribute notes
Minimum gate opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{B78D78DA-73F8-461d-BC4B-162CEC1D5862}show detailsdid not existPU [0..1]Steady state droop (Rp). Typical value = 0,05.
Attribute notes
Steady state droop (Rp). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{6A8EA68C-4D94-482d-9E77-A3F1B8DBB604}show detailsdid not existSeconds [0..1]Input filter time constant (Td) (>=0). Typical value = 0.
Attribute notes
Input filter time constant (Td) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{A536A0A5-C808-432b-ACDC-43C72798A8B0}show detailsdid not existSeconds [0..1]Derivative time constant (Tf) (>=0). Typical value = 0,25.
Attribute notes
Derivative time constant (Tf) (>=0). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{2969005B-E495-41c8-9B4A-E551F2552663}show detailsdid not existFloat [0..1]Gate servo inverse of gain (Tg). Typical value = 0,1.
Attribute notes
Gate servo inverse of gain (Tg). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{D6F39126-96D8-495a-B2BD-C0147D552FF9}show detailsdid not existSeconds [0..1]Gate servo time constant (Tp) (>=0). Typical value = 0.
Attribute notes
Gate servo time constant (Tp) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{3C321A5B-51AC-40f2-932B-18D9D7227652}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tti{AFFB951A-36BF-4f34-996A-D9B92307F110}show detailsdid not existSeconds [0..1]Power measurement time constant (Tt) (>=0). Typical value = 1.
Attribute notes
Power measurement time constant (Tt) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namett
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
velcli{C2E8547F-347C-47b3-BD23-3CE3A0798527}show detailsdid not existPU [0..1]Maximum gate closing velocity (Vel_cl). Typical value = -1.
Attribute notes
Maximum gate closing velocity (Vel_cl). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
velopi{76219679-404E-428a-B864-CDC13F175B10}show detailsdid not existPU [0..1]Maximum gate opening velocity (Vel_op). Typical value = 1.
Attribute notes
Maximum gate opening velocity (Vel_op). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelop
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroDD
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEHydroLLi
Class notes
Lead-lag hydro governor. Reference: IEEE PES-TR1, 4.2, Figure 4-6.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroLL
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{4FD5D7DC-2D62-436b-A7BD-5EB50D523981}
Class notes
Lead-lag hydro governor. Reference: IEEE PES-TR1, 4.2, Figure 4-6.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroLL
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
db1i{76E24050-905B-4a8e-81B2-6C83665CD743}show detailsdid not existPU [0..1]Dead band (db1). Typical value = 0.
Attribute notes
Dead band (db1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db2i{A3A3A1FD-5FD1-43c6-9DDA-8A19A4F9C725}show detailsdid not existPU [0..1]Dead band (db2). Typical value = 0.
Attribute notes
Dead band (db2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
flagi{C7EBEB0A-5305-441d-B85C-4DDF3E2FDC7A}show detailsdid not existBoolean [0..1]Power feedback selector (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute notes
Power feedback selector (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameflag
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
gmaxi{9970CB82-6E69-466f-920B-14A1CCE53AD7}show detailsdid not existPU [0..1]Maximum governor output (Gmax). Typical value = 1.
Attribute notes
Maximum governor output (Gmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gmini{4EDA03EE-79BD-4125-9FDB-8A21C6F60B5D}show detailsdid not existPU [0..1]Minimum governor output (Gmin). Typical value = 0.
Attribute notes
Minimum governor output (Gmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{3317E4C8-847E-42b0-BFA6-DE5D3AB8FB20}show detailsdid not existFloat [0..1]Integral gain (Ki). Typical value = 0,5.
Attribute notes
Integral gain (Ki). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{0A1FD490-54F5-4d29-B598-CE8B7525135E}show detailsdid not existPU [0..1]Maximum gate opening (Pmax). Typical value = 1.
Attribute notes
Maximum gate opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{F365523A-48D3-4451-A2E1-24F6A0CDB3CC}show detailsdid not existPU [0..1]Minimum gate opening (Pmin). Typical value = 0.
Attribute notes
Minimum gate opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{C8833440-D6C5-47c1-B8A4-7AF54E51A3BD}show detailsdid not existFloat [0..1]Permanent droop (Rp). Typical value = 0,05.
Attribute notes
Permanent droop (Rp). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{2BF9F91D-2269-4d5f-B2FE-082C15EA6720}show detailsdid not existSeconds [0..1]First lead-lag lead time constant (T1) (>=0). Typical value = 3,5.
Attribute notes
First lead-lag lead time constant (T1) (>=0). Typical value = 3,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t2i{08C6D007-FD90-4122-9FE2-079DD2511439}show detailsdid not existSeconds [0..1]First lead-lag lag time constant (T2) (>=0). Typical value = 1.
Attribute notes
First lead-lag lag time constant (T2) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t3i{77A0911E-16AC-486f-A689-835F7700AE59}show detailsdid not existSeconds [0..1]Second lead-lag lead time constant (T3) (>=0). Typical value = 3,5.
Attribute notes
Second lead-lag lead time constant (T3) (>=0). Typical value = 3,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t4i{527EFB61-AF86-43ce-9D1D-F0F95F824192}show detailsdid not existSeconds [0..1]Second lead-lag lag time constant (T4) (>=0). Typical value = 1.
Attribute notes
Second lead-lag lag time constant (T4) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t5i{354AA2E7-44CF-4c67-85EE-987EE7BDFF41}show detailsdid not existSeconds [0..1]Third lead-lag lead time constant (T5) (>=0). Typical value = 0.
Attribute notes
Third lead-lag lead time constant (T5) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet5
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t6i{E2D05EF7-D41D-4f8e-B28C-27C2DC76741C}show detailsdid not existSeconds [0..1]Third lead-lag lag time constant (T6) (>=0). Typical value = 0.
Attribute notes
Third lead-lag lag time constant (T6) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet6
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{9176E10D-5B1E-4989-BC2F-E73EC0633C91}show detailsdid not existSeconds [0..1]Speed input filte time constant (Td) (>=0). Typical value = 0,1.
Attribute notes
Speed input filte time constant (Td) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{C21D3A6F-687E-45ab-8159-0902D1EDAE71}show detailsdid not existFloat [0..1]Gate servo inverse of gain (Tg). Typical value = 0,2.
Attribute notes
Gate servo inverse of gain (Tg). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{A82CD8B7-8544-4d16-82BA-A57A4CEFF35F}show detailsdid not existFloat [0..1]Gate servo time constant (Tp). Typical value = 0.
Attribute notes
Gate servo time constant (Tp). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{8CA40C53-7317-4270-82E2-290DAEB35295}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tti{EAA33D7E-B765-4934-BDC4-094F13BD4479}show detailsdid not existSeconds [0..1]Electical power filter time constant (Tt) (>=0). Typical value = 2.
Attribute notes
Electical power filter time constant (Tt) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namett
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
velcli{889996DE-3DC1-4087-BFE2-F2D578246A3B}show detailsdid not existPU [0..1]Maximum gate closing velocity (Vel_cl). Typical value = -1.
Attribute notes
Maximum gate closing velocity (Vel_cl). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
velopi{A3B8B8EB-5D34-4d63-8324-BBC957833742}show detailsdid not existPU [0..1]Maximum gate opening velocity (Vel_op). Typical value = 1.
Attribute notes
Maximum gate opening velocity (Vel_op). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelop
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroLL
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEHydroMechi
Class notes
Mechanical hydraulic governor model. Reference: IEEE PES-TR1, 4.2, Figure 4-3.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroMech
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{9468B473-2547-47ca-A0F8-460D95E44A68}
Class notes
Mechanical hydraulic governor model. Reference: IEEE PES-TR1, 4.2, Figure 4-3.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroMech
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
db1i{4CC21B4E-00BE-47d9-9374-B99079F9C0AA}show detailsdid not existPU [0..1]Deadband width (db1). Typical value = 0.
Attribute notes
Deadband width (db1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db2i{E2F16FD9-DD56-4d2b-96CF-532726DA9CA9}show detailsdid not existPU [0..1]Unintentional deadband (db2). Typical value = 0.
Attribute notes
Unintentional deadband (db2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
mwbasei{36DE3829-EE15-4cc5-85FB-055812B85398}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{FE8DA23D-C160-47aa-B7C1-DA71B4ED1580}show detailsdid not existPU [0..1]Maximum gate opening (Pmax). Typical value = 1.
Attribute notes
Maximum gate opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{21FAC7B7-D762-49b6-99D7-0B503C083DC6}show detailsdid not existPU [0..1]Minimum gate opening (Pmin). Typical value = 0.
Attribute notes
Minimum gate opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{211CEFEF-FF48-48ad-8BA5-AD812E02A7F1}show detailsdid not existPU [0..1]Permanent droop (Rp). Typical value = 0,05.
Attribute notes
Permanent droop (Rp). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rti{F3AFDCA3-BA55-4cf9-857C-D9366D83A332}show detailsdid not existPU [0..1]Temporary droop (Rt). Typical value = 0,5.
Attribute notes
Temporary droop (Rt). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namert
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{865527AF-08E7-4112-A2C0-EA22A16B0929}show detailsdid not existSeconds [0..1]Gate servo time constant (Tg) (>=0). Typical value = 0,5.
Attribute notes
Gate servo time constant (Tg) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{EEE10E80-EE40-4ff7-AB76-32F8EA091900}show detailsdid not existSeconds [0..1]Pilot servo valve time constant (Tp) (>=0). Typical value = 0,03.
Attribute notes
Pilot servo valve time constant (Tp) (>=0). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tri{A91F9504-16F0-4858-84A8-7B1CB876AF1B}show detailsdid not existSeconds [0..1]Dashpot time constant (Tr) (>=0). Typical value = 12.
Attribute notes
Dashpot time constant (Tr) (>=0). Typical value = 12.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
velcli{C249E27F-598E-4057-BF87-3E0633F1184E}show detailsdid not existFloat [0..1]Maximum gate closing velocity (Vel_cl). Typical value = -0,3.
Attribute notes
Maximum gate closing velocity (Vel_cl). Typical value = -0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelcl
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
velopi{EC8803D6-9D3A-4730-B472-8E4AF7CA97F1}show detailsdid not existFloat [0..1]Maximum gate opening velocity (Vel_op). Typical value = 0,3.
Attribute notes
Maximum gate opening velocity (Vel_op). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelop
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroMech
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEHydroPIDi
Class notes
Hydro PID governor. Reference: IEEE PES-TR1, 4.2, Figure 4-4.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroPID
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{021EFC6D-E8C6-49df-9D4D-7CCCA9005884}
Class notes
Hydro PID governor. Reference: IEEE PES-TR1, 4.2, Figure 4-4.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroPID
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
db1i{27415FAB-E27A-4ed7-A34E-8963DA3B5B9D}show detailsdid not existPU [0..1]Dead band (db1). Typical value = 0.
Attribute notes
Dead band (db1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db2i{9F6A5015-088E-4e1d-9AEA-60BA07AB0F67}show detailsdid not existPU [0..1]Dead band (db2). Typical value = 0.
Attribute notes
Dead band (db2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
flagi{4E3FF7C6-274D-400b-9DDE-6AECD4D14E44}show detailsdid not existBoolean [0..1]Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute notes
Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameflag
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
gmaxi{C8A8B75A-686D-4774-B976-C5C9583A8DBD}show detailsdid not existPU [0..1]Maximum governor output (Gmax). Typical value = 1.
Attribute notes
Maximum governor output (Gmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gmini{70FBDC3D-1ACE-47f0-865B-00D9D10605B7}show detailsdid not existPU [0..1]Minimum governor output (Gmin). Typical value = 0.
Attribute notes
Minimum governor output (Gmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{C9B64D25-8005-4ec1-9D35-BBC7CCCF2304}show detailsdid not existPU [0..1]Derivative gain (Kd). Typical value = 0,1.
Attribute notes
Derivative gain (Kd). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{FA68734C-1E44-4232-B203-DE7E9A796173}show detailsdid not existPU [0..1]Integral gain (Ki). Typical value = 0,2.
Attribute notes
Integral gain (Ki). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{29BBC577-5D5C-4338-83E9-1B8D45972159}show detailsdid not existPU [0..1]Proportional gain (Kp). Typical value = 2.
Attribute notes
Proportional gain (Kp). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{79A68481-3C81-4db1-AE12-594B93004C18}show detailsdid not existPU [0..1]Maximum gate opening (Pmax). Typical value = 1.
Attribute notes
Maximum gate opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{1F725EFB-9575-491b-8BD2-264D987AC415}show detailsdid not existPU [0..1]Minimum gate opening (Pmin). Typical value = 0.
Attribute notes
Minimum gate opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{0BAB29D6-7B40-4482-9AF2-141078C09002}show detailsdid not existPU [0..1]Permanent droop (Rp). Typical value = 0,05.
Attribute notes
Permanent droop (Rp). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{19A58955-C0CC-4ec0-9C56-F64C6157F2B8}show detailsdid not existSeconds [0..1]Input filter time constant (Td) (>=0). Typical value = 0,1.
Attribute notes
Input filter time constant (Td) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{E669D13B-056C-4247-9100-A5AD74FA12EE}show detailsdid not existSeconds [0..1]Derivative time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Derivative time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{41DFE533-D146-4988-BDBD-5070EE7CCDD7}show detailsdid not existFloat [0..1]Gate servo inverse of gain (Tg). Typical value = 0,5.
Attribute notes
Gate servo inverse of gain (Tg). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{8E9C93F7-5EE1-431e-B5F1-0F64A57A9EC1}show detailsdid not existSeconds [0..1]Gate servo time constant (Tp) (>=0). Typical value = 0,1.
Attribute notes
Gate servo time constant (Tp) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{B5FC71AC-DB2B-473d-AE6C-DBEFD1A12CED}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tti{6E1D4DAA-A81D-4199-9E5D-B05B8E3B9CC9}show detailsdid not existSeconds [0..1]Power measurement time constant (Tt) (>=0). Typical value = 0,5.
Attribute notes
Power measurement time constant (Tt) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namett
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
velcli{C79CBBED-7320-4719-8643-27A8FB02F9CE}show detailsdid not existPU [0..1]Maximum gate closing velocity (Vel_cl). Typical value = -0,3.
Attribute notes
Maximum gate closing velocity (Vel_cl). Typical value = -0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
velopi{4C6AB528-368D-4d8c-AAAB-44DBB4DF753E}show detailsdid not existPU [0..1]Maximum gate opening velocity (Vel_op). Typical value = 0,3.
Attribute notes
Maximum gate opening velocity (Vel_op). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelop
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroPID
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovIEEEHydroPIDspti
Class notes
Hydro PID governor with set-point control and nonlinear compensation. Reference: IEEE PES-TR1, 4.2, Figure 4-7.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroPIDspt
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{48D31FA2-1E8A-4c10-B8CE-B9C1FD9B06E4}
Class notes
Hydro PID governor with set-point control and nonlinear compensation. Reference: IEEE PES-TR1, 4.2, Figure 4-7.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovIEEEHydroPIDspt
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
db1i{459BD6A6-DEEF-4d0a-87D0-E995B9D390C6}show detailsdid not existPU [0..1]Dead band (db1). Typical value = 0.
Attribute notes
Dead band (db1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db2i{5C8FF8DB-3E63-4d50-AE5F-08EC8ECC110A}show detailsdid not existPU [0..1]Dead band (db2). Typical value = 0.
Attribute notes
Dead band (db2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
db3i{A44CF4C8-1401-4ce5-8FE4-BC5D6EED4093}show detailsdid not existPU [0..1]Dead band (db3). Typical value = 0.
Attribute notes
Dead band (db3). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedb3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
flagi{91231E7C-8B35-4851-91DB-A3402A9D36A4}show detailsdid not existBoolean [0..1]Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute notes
Droop switch (Flag). True means electrical power (Flag=1). False means mechanical feedback (Flag=0). Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameflag
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
gi{4F16DBF1-7A3D-4bc7-B74D-70D66C21BB5D}show detailsdid not existString [0..1](G).
Attribute notes
(G).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameg
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
gmaxi{E7068E5B-54BC-416d-995C-D39EF599A86B}show detailsdid not existPU [0..1]Maximum governor output (Gmax). Typical value = 1.
Attribute notes
Maximum governor output (Gmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gmini{7EF2506F-C3A9-4410-8733-49B9E683B9F2}show detailsdid not existPU [0..1]Minimum governor output (Gmin). Typical value = 0.
Attribute notes
Minimum governor output (Gmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{EDE46907-AB3E-4460-AF4D-7FB24A9448CB}show detailsdid not existFloat [0..1]Compensation factor (Ka). Typical value = 0,1.
Attribute notes
Compensation factor (Ka). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{111E32C6-DCD8-464b-B5AB-81D0F5D1EF2A}show detailsdid not existPU [0..1]Derivative gain (Kd). Typical value = 0,1.
Attribute notes
Derivative gain (Kd). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{02E86CD5-63D3-4c27-8796-420E96495E22}show detailsdid not existFloat [0..1]Setpoint control factor (Kf). Typical value = 0.
Attribute notes
Setpoint control factor (Kf). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{9F19A15A-4644-4259-A77B-1F86E8F7CECF}show detailsdid not existPU [0..1]Integral gain (Ki). Typical value = 0,5.
Attribute notes
Integral gain (Ki). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{E5EDF0B6-7488-408e-AA96-8AC38D9B7C87}show detailsdid not existPU [0..1]Proportional gain (Kp). Typical value = 5.
Attribute notes
Proportional gain (Kp). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{A0AC21F2-7691-41cb-A7A1-2092E228A34A}show detailsdid not existPU [0..1]Maximum gate opening (Pmax). Typical value = 1.
Attribute notes
Maximum gate opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{613208B0-125E-4633-BE27-05243B69901C}show detailsdid not existPU [0..1]Minimum gate opening (Pmin). Typical value = 0.
Attribute notes
Minimum gate opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rpi{D796881F-6C60-4222-A41E-AF706311B106}show detailsdid not existPU [0..1]Permanent droop (Rp). Typical value = 0,05.
Attribute notes
Permanent droop (Rp). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namerp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{B30B6D82-5EBB-4272-BD58-81B92B0E4601}show detailsdid not existSeconds [0..1]Input filter time constant (Td) (>=0). Typical value = 0,1.
Attribute notes
Input filter time constant (Td) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{516E30AA-6B9A-4d4a-A366-EE54A87964A7}show detailsdid not existSeconds [0..1]Derivative time constant (Tf) (>=0). Typical value = 0,1.
Attribute notes
Derivative time constant (Tf) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{68E658F8-99D4-4610-A254-5D6BE9C4F7F2}show detailsdid not existFloat [0..1]Gate servo inverse of gain (Tg). Typical value = 0,5.
Attribute notes
Gate servo inverse of gain (Tg). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tpi{81EB7ED3-6E05-43bc-8389-63F2203DA774}show detailsdid not existSeconds [0..1]Gate servo time constant (Tp) (>=0). Typical value = 0,1.
Attribute notes
Gate servo time constant (Tp) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametp
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{445E8049-6D33-4252-A064-8074F6FAAF28}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tti{C782B5C1-6F18-4ce4-BDD3-1BF5F0EA39F0}show detailsdid not existSeconds [0..1]Power measurement time constant (Tt) (>=0). Typical value = 2.
Attribute notes
Power measurement time constant (Tt) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namett
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
velcli{2B42EA1C-0C62-4442-B753-0AFA331EE3EC}show detailsdid not existPU [0..1]Maximum gate closing velocity (Vel_cl). Typical value = -0,33.
Attribute notes
Maximum gate closing velocity (Vel_cl). Typical value = -0,33.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
velopi{E7ECDB87-DA53-495a-92E7-59E2AD474CDE}show detailsdid not existPU [0..1]Maximum gate opening velocity (Vel_op). Typical value = 0,33.
Attribute notes
Maximum gate opening velocity (Vel_op). Typical value = 0,33.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevelop
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroPIDspt
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovSteamIEEEG1Augi
Class notes
Augmented IEEEG1 steam turbine-governor model with simplified boiler dynamics and coordinate control. Reference: IEEE PES-TR1, 2.3.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovSteamIEEEG1Aug
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{6E31CCA3-2740-46de-B116-FAE66A67CD59}
Class notes
Augmented IEEEG1 steam turbine-governor model with simplified boiler dynamics and coordinate control. Reference: IEEE PES-TR1, 2.3.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovSteamIEEEG1Aug
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
dbd1i{A5144FEB-671C-42a7-AD43-99525A32B147}show detailsdid not existPU [0..1]Speed deviation deadband (dbd1). Typical value = 0.
Attribute notes
Speed deviation deadband (dbd1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedbd1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
fmaxi{6AB54C5E-669E-495e-9503-BE6CEC74C5B9}show detailsdid not existPU [0..1]Maximum boiler controller output (fmax). Typical value = 1,2.
Attribute notes
Maximum boiler controller output (fmax). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
fmini{01A3662B-3382-460f-A38B-5FE0D1FDFDEA}show detailsdid not existPU [0..1]Minimum boiler controller output (fmin). Typical value = 0,1.
Attribute notes
Minimum boiler controller output (fmin). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki{C8006488-67F1-46b7-9E57-878230DA3B8C}show detailsdid not existPU [0..1]Governor gain (K). Typical value = 25.
Attribute notes
Governor gain (K). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k1i{999755AB-E229-4b9f-B503-4F57D2AE9D14}show detailsdid not existPU [0..1]Fraction of HP shaft power first boiler pass (K1). Typical value = 0,2.
Attribute notes
Fraction of HP shaft power first boiler pass (K1). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k3i{245193BF-8726-4e43-AD2F-849D6110C6EB}show detailsdid not existPU [0..1]Fraction of HP shaft power second boiler pass (K3). Typical value = 0,3.
Attribute notes
Fraction of HP shaft power second boiler pass (K3). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k5i{EFE4F01D-EE7E-4cec-85A7-ED783F24FFF2}show detailsdid not existPU [0..1]Fraction of HP shaft power third boiler pass (K5). Typical value = 0,5.
Attribute notes
Fraction of HP shaft power third boiler pass (K5). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek5
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k7i{E51B2E8C-BB49-453e-947A-B67769E18AB0}show detailsdid not existPU [0..1]Fraction of HP shaft power fourth boiler pass (K7). Typical value = 0.
Attribute notes
Fraction of HP shaft power fourth boiler pass (K7). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek7
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kbi{F0C7240D-0705-4738-B2C4-607769186ED9}show detailsdid not existPU [0..1]Load reference control speed deviation bias (Kb). Typical value = 0,02.
Attribute notes
Load reference control speed deviation bias (Kb). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kifi{810FE5DF-D19E-4cab-875D-038D61E0B182}show detailsdid not existPU [0..1]Boiler controller integral gain (Kif). Typical value = 0,1.
Attribute notes
Boiler controller integral gain (Kif). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekif
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kipi{675F2F1C-FD69-47ed-8A03-02CE57E7EC2A}show detailsdid not existFloat [0..1]Load reference servo inverse time constant (Kip). Typical value = 5.
Attribute notes
Load reference servo inverse time constant (Kip). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekip
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
kli{AEEEFCE0-52AF-4356-AA70-ABFBCB968AC6}show detailsdid not existPU [0..1]Load reference feedback gain (Kl). Typical value = 1.
Attribute notes
Load reference feedback gain (Kl). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmi{39C529DB-5F1A-4fca-9B15-408F60D4C050}show detailsdid not existPU [0..1]Pressure drop adjustment factor (Km). Typical value = 0.
Attribute notes
Pressure drop adjustment factor (Km). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmwi{B6905B87-FF8A-4c1d-89C4-AE7A0DFB2C05}show detailsdid not existPU [0..1]Load demand to pressure setpoint gain (Kmw). Typical value = 0,02.
Attribute notes
Load demand to pressure setpoint gain (Kmw). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekmw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpeleci{D764ADBD-EE41-4f0b-919B-E658B047D530}show detailsdid not existPU [0..1]MW transducer gain (Kpelec). Typical value = 0.
Attribute notes
MW transducer gain (Kpelec). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpelec
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pdbi{C7248850-3EB0-4f33-B926-C6661447C9E3}show detailsdid not existPU [0..1]Pressure error to load reference deadband (pdb). Typical value = 0,001.
Attribute notes
Pressure error to load reference deadband (pdb). Typical value = 0,001.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepdb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{8F99F8E3-B3B6-4dbe-BB08-DDE254F53B87}show detailsdid not existPU [0..1]Maximum valve opening (Pmax). Typical value = 1.
Attribute notes
Maximum valve opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{0B104E45-0D6E-4b5d-AEFB-043BB5914902}show detailsdid not existPU [0..1]Minimum valve opening (Pmin). Typical value = 0.
Attribute notes
Minimum valve opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
presrefi{7D798C1B-ABAE-42ab-8F2A-B44CD33E7E59}show detailsdid not existPU [0..1]Reference pressure (Pres_ref). Typical value = 1.
Attribute notes
Reference pressure (Pres_ref). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepresref
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rmaxi{8F61914B-521F-4ce2-AF09-C38538DFC9EC}show detailsdid not existPU [0..1]Load reference gradient upper limit (rmax). Typical value = 1.
Attribute notes
Load reference gradient upper limit (rmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namermax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rmini{705767C4-BB24-48ab-AE06-3B731F6EF007}show detailsdid not existPU [0..1]Load reference gradient lower limit (rmin). Typical value = -1.
Attribute notes
Load reference gradient lower limit (rmin). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namermin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{96F65CEE-EDAB-4fbc-B0AD-E7E5C6DB5EE3}show detailsdid not existSeconds [0..1]Governor lag time constant (T1) (>=0). Typical value = 0,2.
Attribute notes
Governor lag time constant (T1) (>=0). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t2i{14859402-1DF5-492e-AE3E-27877566D4B5}show detailsdid not existSeconds [0..1]Governor lead time constant (T2) (>=0). Typical value = 1.
Attribute notes
Governor lead time constant (T2) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t3i{0DDA19C9-BE1D-4bea-B98D-BA6642C1A1B3}show detailsdid not existSeconds [0..1]Valve positioner time constant (T3) (>=0). Typical value = 0,5.
Attribute notes
Valve positioner time constant (T3) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t4i{051051E1-443F-42d3-A6DE-212495D02049}show detailsdid not existSeconds [0..1]Inlet piping/steam bowl time constant (T4) (>=0). Typical value = 0,3.
Attribute notes
Inlet piping/steam bowl time constant (T4) (>=0). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t5i{6BA62B10-4DA9-4be0-95ED-4595F9B24249}show detailsdid not existSeconds [0..1]Second boiler pass time constant (T5) (>=0). Typical value = 5.
Attribute notes
Second boiler pass time constant (T5) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet5
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t6i{5673B7DF-11DF-4eef-A989-7F7FCEB3D94D}show detailsdid not existSeconds [0..1]Third boiler pass time constant (T6) (>=0). Typical value = 0,5.
Attribute notes
Third boiler pass time constant (T6) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet6
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t7i{2A7DB713-E194-4120-AC12-768D7FCFB057}show detailsdid not existSeconds [0..1]Fourth boiler pass time constant (T7) (>=0). Typical value = 0.
Attribute notes
Fourth boiler pass time constant (T7) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet7
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{EFF125B7-E2FA-4159-9E27-70A35F9B45EA}show detailsdid not existSeconds [0..1]Boiler storage time constant (Td) (>=0). Typical value = 750.
Attribute notes
Boiler storage time constant (Td) (>=0). Typical value = 750.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{571BEE38-B8E6-45de-A2F1-6357E1E30C7E}show detailsdid not existSeconds [0..1]Fuel supply time constant (Tf) (>=0). Typical value = 25.
Attribute notes
Fuel supply time constant (Tf) (>=0). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tpeleci{A66796A3-3639-4e92-94E8-8EC35F237AA4}show detailsdid not existSeconds [0..1]MW transducer time constant (Tpelec) (>=0). Typical value = 10.
Attribute notes
MW transducer time constant (Tpelec) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametpelec
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{D452363A-F7EB-40cc-BDD3-8BD3B170D500}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{8B73FDAF-0F1C-43e2-8EB5-C52419B4718A}show detailsdid not existSeconds [0..1]Waterwall time constant (Tw) (>=0). Typical value = 7.
Attribute notes
Waterwall time constant (Tw) (>=0). Typical value = 7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
uci{BD30386A-139A-49b2-BE06-0B00B8D3171A}show detailsdid not existPU [0..1]Maximum vave losing velocity (Uc). Typical value = -0,3.
Attribute notes
Maximum vave losing velocity (Uc). Typical value = -0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameuc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
uoi{9B883A29-CB5E-4bc6-8760-91B6BAE71930}show detailsdid not existPU [0..1]Maximum valve opening velocity (Uo). Typical value = 0,3.
Attribute notes
Maximum valve opening velocity (Uo). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameuo
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmaxi{88808EB0-BAFB-494b-93EE-B7A8ABAC817D}show detailsdid not existPU [0..1]Load reference upper limit (vmax). Typical value = 1,2.
Attribute notes
Load reference upper limit (vmax). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmini{B414D2E5-663E-45d0-8ED5-445B15A39304}show detailsdid not existPU [0..1]Load reference lower limit (vmin). Typical value = 0,2.
Attribute notes
Load reference lower limit (vmin). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovSteamIEEEG1Aug
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙GovSteamIEEETGOV5i
Class notes
Detailed steam turbine-governor model with boiler system, IEEE TGOV5. Reference: IEEE PES-TR1, 2.4.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovSteamIEEETGOV5
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{9D56E07F-A033-464a-ABD9-8BCCA8C713E3}
Class notes
Detailed steam turbine-governor model with boiler system, IEEE TGOV5. Reference: IEEE PES-TR1, 2.4.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameGovSteamIEEETGOV5
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
bi{199407BE-D880-4cec-988E-8EF8B6B08CAD}show detailsdid not existPU [0..1]Load reference control frequency bias (B). Typical value = 0,04.
Attribute notes
Load reference control frequency bias (B). Typical value = 0,04.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
c1i{EB1533A7-2D71-4d9a-9FE3-810A330F5181}show detailsdid not existPU [0..1]Pressure drop coefficient (C1). Typical value = 0,2.
Attribute notes
Pressure drop coefficient (C1). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namec1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
c2i{D0D6DED2-6951-4965-BFA9-65339B1203C7}show detailsdid not existPU [0..1]Pressure error bias gain (C2). Typical value = 0.
Attribute notes
Pressure error bias gain (C2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namec2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
c3i{609C4ABD-3A89-4a8f-9652-FF293D2FBDA0}show detailsdid not existPU [0..1]Pressure setpoint adjustment (C3). Typical value = 1.
Attribute notes
Pressure setpoint adjustment (C3). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namec3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
cbi{5C15D5F9-71DF-49e8-9B26-3F9DEF2A0195}show detailsdid not existSeconds [0..1]Boiler storage time constant (Cb). Typical value = 750.
Attribute notes
Boiler storage time constant (Cb). Typical value = 750.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namecb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
cmaxi{5B746185-D8F0-42a7-B81A-F535E80D181F}show detailsdid not existPU [0..1]Maximum boiler controller output (Cmax). Typical value = 1,2.
Attribute notes
Maximum boiler controller output (Cmax). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namecmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
cmini{0E900418-26F5-45ff-BC2D-8367AEA2E055}show detailsdid not existPU [0..1]Minimum boiler controller output (Cmin). Typical value = 0,1.
Attribute notes
Minimum boiler controller output (Cmin). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namecmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
dpei{469BC59C-29FE-4d29-A581-94DC33FFA4DB}show detailsdid not existPU [0..1]Pressure error to load reference deadband (dPe). Typical value = 0.
Attribute notes
Pressure error to load reference deadband (dPe). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedpe
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki{436EAF91-F8ED-4829-960C-164B02675C72}show detailsdid not existPU [0..1]Governor gain (K). Typical value = 25.
Attribute notes
Governor gain (K). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k1i{E4A07358-B249-4aab-BA53-A7DA614D1924}show detailsdid not existPU [0..1]Fraction of 1st shaft power first boiler pass (K1). Typical value = 0,2.
Attribute notes
Fraction of 1st shaft power first boiler pass (K1). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k10i{E3FE81CC-74DC-4311-AF37-7DD19A73CF53}show detailsdid not existPU [0..1]Main steam flow anticipation gain (K10). Typical value = 0,1.
Attribute notes
Main steam flow anticipation gain (K10). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek10
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k11i{351BB4BE-BA84-4a0d-B447-A55A4F2F019D}show detailsdid not existPU [0..1]Load demand anticipation gain (K11). Typical value = 0,1.
Attribute notes
Load demand anticipation gain (K11). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek11
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k12i{FA447622-8CE5-4efc-949D-11C46D6B2480}show detailsdid not existPU [0..1]Pressure error bias gain (K12). Typical value = 0,02.
Attribute notes
Pressure error bias gain (K12). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek12
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k13i{36A3620D-ADF2-446a-B3AA-EA74AE80AE92}show detailsdid not existPU [0..1]Load demand to pressure setpoint gain (K13). Typical value = 0,02.
Attribute notes
Load demand to pressure setpoint gain (K13). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek13
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k14i{11A915F5-FAC1-4bd1-A9A0-DAD50F8C1E49}show detailsdid not existFloat [0..1]Load reference servo inverse time constant (K14). Typical value = 5.
Attribute notes
Load reference servo inverse time constant (K14). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek14
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
k2i{669FFBF6-0BCD-44d3-8488-3CF4B2937CE4}show detailsdid not existPU [0..1]Fraction of 2nd shaft power first boiler pass (K2). Typical value = 0.
Attribute notes
Fraction of 2nd shaft power first boiler pass (K2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k3i{83E54113-30F3-42e7-9D11-F24337DDF924}show detailsdid not existPU [0..1]Fraction of 1st shaft power second boiler pass (K3). Typical value = 0,3.
Attribute notes
Fraction of 1st shaft power second boiler pass (K3). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k4i{271A6257-3463-4b28-9E9B-76C6BE3D5BE5}show detailsdid not existPU [0..1]Fraction of 2nd shaft power second boiler pass (K4). Typical value = 0.
Attribute notes
Fraction of 2nd shaft power second boiler pass (K4). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek4
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k5i{523EE709-4386-45aa-803B-225127E2E3BD}show detailsdid not existPU [0..1]Fraction of 1st shaft power third boiler pass (K5). Typical value = 0,5.
Attribute notes
Fraction of 1st shaft power third boiler pass (K5). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek5
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k6i{DF8B7DD3-5F39-4be8-9176-EAFE978642F3}show detailsdid not existPU [0..1]Fraction of 2nd shaft power third boiler pass (K6). Typical value = 0.
Attribute notes
Fraction of 2nd shaft power third boiler pass (K6). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek6
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k7i{32B16E9B-E7AA-4d0b-B3AE-39DD19DF10DC}show detailsdid not existPU [0..1]Fraction of 1st shaft power fourth boiler pass (K7). Typical value = 0.
Attribute notes
Fraction of 1st shaft power fourth boiler pass (K7). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek7
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k8i{A70D444B-6E17-4fe9-91BB-6E24B28AEEF9}show detailsdid not existPU [0..1]Fraction of 2nd shaft power fourth boiler pass (K8). Typical value = 0.
Attribute notes
Fraction of 2nd shaft power fourth boiler pass (K8). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek8
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k9i{E63FB28C-4F91-4f27-AE0C-84A472540640}show detailsdid not existPU [0..1]Pressure drop adjustment factor (K9). Typical value = 0.
Attribute notes
Pressure drop adjustment factor (K9). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek9
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{42170979-7EC5-4ce3-9E03-3FE7EE527616}show detailsdid not existPU [0..1]Boiler controller integral gain (Ki). Typical value = 0,02.
Attribute notes
Boiler controller integral gain (Ki). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kli{5AEE8A7F-61D1-4f70-ABE7-4FA7A9F1B07F}show detailsdid not existPU [0..1]Load reference feedback gain (Kl). Typical value = 1.
Attribute notes
Load reference feedback gain (Kl). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmwi{1B1D1849-BD89-4a6c-84E2-1EA090BFFE05}show detailsdid not existPU [0..1]MW transducer gain (Kmw). Typical value = 0.
Attribute notes
MW transducer gain (Kmw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekmw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
lmaxi{E3022416-9F2E-429e-BFEE-E138F6AA8F10}show detailsdid not existPU [0..1]Load reference upper limit (Lmax). Typical value = 1,2.
Attribute notes
Load reference upper limit (Lmax). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namelmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
lmini{6410127F-3DC5-49b4-9871-05B8F564ECAE}show detailsdid not existPU [0..1]Load reference lower limit (Lmin). Typical value = 0,2.
Attribute notes
Load reference lower limit (Lmin). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namelmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmaxi{AC24EF14-23CB-46b8-AA97-A89544254446}show detailsdid not existPU [0..1]Maximum valve opening (Pmax). Typical value = 1.
Attribute notes
Maximum valve opening (Pmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pmini{5106956B-E892-4ec7-B4BD-91B6297826EB}show detailsdid not existPU [0..1]Minimum valve opening (Pmin). Typical value = 0.
Attribute notes
Minimum valve opening (Pmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rmaxi{AF976EDB-A142-40f0-B2CD-0D77FA58FDC9}show detailsdid not existPU [0..1]Load reference gradient upper limit (Rmax). Typical value = 0,3.
Attribute notes
Load reference gradient upper limit (Rmax). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namermax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
rmini{00CD423C-F838-41db-AE65-A629B944E485}show detailsdid not existPU [0..1]Load reference gradient lower limit (Rmin). Typical value = -0,3.
Attribute notes
Load reference gradient lower limit (Rmin). Typical value = -0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namermin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{CE885668-CFF6-49d9-9F11-EF633896C6BB}show detailsdid not existSeconds [0..1]Governor lag time constant (T1) (>=0). Typical value = 0.
Attribute notes
Governor lag time constant (T1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t2i{A5D4DC15-3416-4de0-B7B9-147EA11D8CD1}show detailsdid not existSeconds [0..1]Governor lead time constant (T2) (>=0). Typical value = 0.
Attribute notes
Governor lead time constant (T2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t3i{2F54EEEB-70BB-46f2-AA70-2FC25F91053B}show detailsdid not existSeconds [0..1]Valve positioner time constant (T3) (>=0). Typical value = 0,1.
Attribute notes
Valve positioner time constant (T3) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t4i{9516B144-F3F1-49b7-AF9C-01555609B514}show detailsdid not existSeconds [0..1]Inlet piping/steam bowl time constant (T4) (>=0). Typical value = 0,3.
Attribute notes
Inlet piping/steam bowl time constant (T4) (>=0). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t5i{C1852551-94E4-4a84-8308-DAE019D1D255}show detailsdid not existSeconds [0..1]Second boiler pass time constant (T5) (>=0). Typical value = 5.
Attribute notes
Second boiler pass time constant (T5) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet5
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t6i{7C122D34-B13A-4b16-B776-D446E3912932}show detailsdid not existSeconds [0..1]Third boiler pass time constant (T6) (>=0). Typical value = 1.
Attribute notes
Third boiler pass time constant (T6) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet6
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t7i{4E44E10B-431C-4e6b-8444-5FA3468483D8}show detailsdid not existSeconds [0..1]Fourth boiler pass time constant (T7) (>=0). Typical value = 0.
Attribute notes
Fourth boiler pass time constant (T7) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet7
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{65CA6788-F5B1-4eef-B75F-669C8122BE58}show detailsdid not existSeconds [0..1]Fuel supply delay time (Td) (>=0). Typical value = 60.
Attribute notes
Fuel supply delay time (Td) (>=0). Typical value = 60.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{CBC27A99-A2B4-41f0-BFA8-350FEA25B6F1}show detailsdid not existSeconds [0..1]Fuel supply time constant (Tf) (>=0). Typical value = 25.
Attribute notes
Fuel supply time constant (Tf) (>=0). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tii{498A79A8-B228-42fe-9DD2-DB5940DB5772}show detailsdid not existSeconds [0..1]Boiler controller proportional lead time constant (Ti) (>=0). Typical value = 90.
Attribute notes
Boiler controller proportional lead time constant (Ti) (>=0). Typical value = 90.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameti
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tmwi{CD08712C-6C9B-475c-A672-E87F980EA0E3}show detailsdid not existSeconds [0..1]MW transducer time constant (Tmw) (>=0). Typical value = 10.
Attribute notes
MW transducer time constant (Tmw) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametmw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tri{5E1F27F4-F789-4e54-8D5D-D6DEAF01D018}show detailsdid not existSeconds [0..1]Boiler controller rate lead time constant (Tr) (>=0). Typical value = 60.
Attribute notes
Boiler controller rate lead time constant (Tr) (>=0). Typical value = 60.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tr1i{47277A84-628F-4bd3-AE7F-5A571F938BDC}show detailsdid not existSeconds [0..1]Boiler controller lag time constant (Tr1) (>=0). Typical value = 6.
Attribute notes
Boiler controller lag time constant (Tr1) (>=0). Typical value = 6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametr1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
trate1i{4940847C-1304-41af-A454-03775937F088}show detailsdid not existActivePower [0..1]Turbine rated power, 1st shaft (Trate1). Typical value = 0.
Attribute notes
Turbine rated power, 1st shaft (Trate1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate1
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
trate2i{5BFE35C8-FDCC-452b-99F2-ECC1DD2DC252}show detailsdid not existActivePower [0..1]Turbine rated power, 2nd shaft (Trate2). Typical value = 0.
Attribute notes
Turbine rated power, 2nd shaft (Trate2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate2
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{D087DC5D-3FA5-4ae5-8738-82330CD9BA2C}show detailsdid not existSeconds [0..1]Waterwall time constant (Tw) (>=0). Typical value = 7.
Attribute notes
Waterwall time constant (Tw) (>=0). Typical value = 7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
uci{E4729731-37D2-42f5-9CF8-66B0B7A70CBF}show detailsdid not existPU [0..1]Maximum valve closing rate (Uc). Typical value = -0,25.
Attribute notes
Maximum valve closing rate (Uc). Typical value = -0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameuc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
uoi{222C76B1-5589-4b0e-8465-068797784027}show detailsdid not existPU [0..1]Maximum valve opening rate (Uo). Typical value = 0,25.
Attribute notes
Maximum valve opening rate (Uo). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameuo
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovSteamIEEETGOV5
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCrossCompoundTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙HydroGovernorDynamicsi
Class notes
Hydro governor function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameHydroGovernorDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{C5623CAA-E4C6-4e1c-A9F2-71FCA289EE49}
Class notes
Hydro governor function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameHydroGovernorDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroPIDspt
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroDD
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroPID
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroLL
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovIEEEHydroMech
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
DestinationHydroGovernorDynamics role HydroGovernorDynamics [1] → HydroWaterColumnDynamics role HydroWaterColumnDynamics [1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHydroGovernorDynamics
RoleNoteThe hydro governor that has a hydro water column model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHydroWaterColumnDynamics
RoleNoteThe hydro water model of this hydro governor model.
Scopepublic
TargetScopeinstance
▶⚙HydroWaterColumnDynamicsi
Class notes
Hydro water column function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameHydroWaterColumnDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{4D1728E2-0AFF-4bce-93CD-19C69AD77B55}
Class notes
Hydro water column function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameHydroWaterColumnDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinearA
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinear
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWClinear
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinearB
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCgen
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
DestinationHydroGovernorDynamics role HydroGovernorDynamics [1] → HydroWaterColumnDynamics role HydroWaterColumnDynamics [1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHydroGovernorDynamics
RoleNoteThe hydro governor that has a hydro water column model.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleHydroWaterColumnDynamics
RoleNoteThe hydro water model of this hydro governor model.
Scopepublic
TargetScopeinstance
▶⚙SteamTurbineGeneratorDynamicsi
Class notes
Steam turbine (ST) and a heat-recovery steam generator (HRSG) function block<font color="#0f0f0f">.</font>
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameSteamTurbineGeneratorDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0E50BC92-F22E-4e38-BE2A-054FDEA9F0AE}
Class notes
Steam turbine (ST) and a heat-recovery steam generator (HRSG) function block<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameSteamTurbineGeneratorDynamics
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbCIGREHRSGST
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEGenericHRSGST
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
DestinationCombinedCycleGasTurbineDynamics role CombinedCycleGasTurbineDynamics [1..*] → SteamTurbineGeneratorDynamics role SteamTurbineGeneratorDynamics [1]
Link metadata
BaselineDestination
DirectionUnspecified
IsLeaffalse
IsRootfalse
TypeAssociation
Source end
BaselineDestination
Cardinality1..*
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleCombinedCycleGasTurbineDynamics
RoleNoteThe gas turbine dynamics model part of a combined cycle power plant.
Scopepublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality1
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregationnone
IsChangeablenone
IsNavigabletrue
Orderingfalse
RoleSteamTurbineGeneratorDynamics
RoleNoteThe steam turbine and a heat-recovery steam generator connected to this gas turbine of a combined cycle power plant.
Scopepublic
TargetScopeinstance
▶⚙TurbCIGREHRSGSTi
Class notes
CIGRE heat-recovery steam generator (HRSG) and a steam turbine model. Reference: IEEE PES-TR1, 3.2.2.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbCIGREHRSGST
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{09AAE73A-DFE2-46a8-9E06-D98E65B6E74E}
Class notes
CIGRE heat-recovery steam generator (HRSG) and a steam turbine model. Reference: IEEE PES-TR1, 3.2.2.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbCIGREHRSGST
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
bvi{B8A8794B-2201-44cc-A585-B68B345DDAFB}show detailsdid not existPU [0..1]Steam dynamics constant (Bv). Typical value = 0,316227.
Attribute notes
Steam dynamics constant (Bv). Typical value = 0,316227.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namebv
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gtrate1i{99EF4CA9-B093-4035-9DCD-819BCF7429F2}show detailsdid not existActivePower [0..1]First gas turbine rated power (GTrate1). Typical value = 0.
Attribute notes
First gas turbine rated power (GTrate1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegtrate1
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
gtrate2i{D6C04163-1D34-4b11-B116-3D0887191591}show detailsdid not existActivePower [0..1]Second gas turbine rated power (GTrate2). Typical value = 0.
Attribute notes
Second gas turbine rated power (GTrate2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegtrate2
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
gtrate3i{B975E772-FDB6-441e-8156-B9A55B97E1F2}show detailsdid not existActivePower [0..1]Third gas turbine rated power (GTrate3). Typical value = 0.
Attribute notes
Third gas turbine rated power (GTrate3). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegtrate3
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
gtrate4i{FB8F238D-F5E3-4b29-B537-D0121909AA3A}show detailsdid not existActivePower [0..1]Fourth gas turbine rated power (GTrate4). Typical value = 0.
Attribute notes
Fourth gas turbine rated power (GTrate4). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegtrate4
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{E7684D08-5ECB-45b4-98AF-75736677E9A7}show detailsdid not existPU [0..1]Bypass valve control integral gain (Ki). Typical value = 2.
Attribute notes
Bypass valve control integral gain (Ki). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmi{9108CABA-3709-4e81-8E93-2F3D2301261C}show detailsdid not existPU [0..1]Steam dynamics constant (Km). Typical value = 0,15.
Attribute notes
Steam dynamics constant (Km). Typical value = 0,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{FD26FAE2-FD97-46dc-A203-B30855F8E6DA}show detailsdid not existPU [0..1]Bypass valve control proportional gain (Kp). Typical value = 10.
Attribute notes
Bypass valve control proportional gain (Kp). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pgtqgi{673ADF6B-42C4-4235-AF01-F7840826FAA6}show detailsdid not existString [0..1] (PgtQg).
Attribute notes
(PgtQg).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepgtqg
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
predi{F82F9BE9-DDEE-4823-AFC9-898CBEC2D82E}show detailsdid not existString [0..1] (Pred).
Attribute notes
(Pred).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepred
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
prefi{E8F021C8-6AA7-4e99-8377-0CEA017B7864}show detailsdid not existPU [0..1]Reference for minimum power (Pref). Typical value = 0,25.
Attribute notes
Reference for minimum power (Pref). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepref
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qsi{7B7E1560-5DF1-4749-9011-B22EFC29901C}show detailsdid not existPU [0..1]Input flow bias (Qs). Typical value = 0,1.
Attribute notes
Input flow bias (Qs). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqs
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{957C6D0E-97BC-4025-A2A7-3DD04719E5C9}show detailsdid not existSeconds [0..1]Turbine lag time constant (Td) (>=0). Typical value = 10.
Attribute notes
Turbine lag time constant (Td) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdrumi{CBE11E71-A51D-40c0-9FC6-64B9F90B0B60}show detailsdid not existSeconds [0..1]Steam drum time constant (Tdrum) (>=0). Typical value = 300.
Attribute notes
Steam drum time constant (Tdrum) (>=0). Typical value = 300.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdrum
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tni{28CB56F7-CFB4-41b0-ABF6-99A4C68D801F}show detailsdid not existSeconds [0..1]Turbine lead time constant (Tn) (>=0). Typical value = 3.
Attribute notes
Turbine lead time constant (Tn) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametn
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{AC1D5930-42BC-422b-990F-F8DAED2CA1CB}show detailsdid not existActivePower [0..1]Steam turbine rated power (Trate). Typical value = 0.
Attribute notes
Steam turbine rated power (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tvi{217E251A-CEFD-428e-B473-E5A528D2CDA7}show detailsdid not existSeconds [0..1]Bypass valve time constant (Tv) (>=0). Typical value = 0,5.
Attribute notes
Bypass valve time constant (Tv) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametv
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbCIGREHRSGST
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEGenericHRSGSTi
Class notes
Generic heat-recovery steam generator (HRSG) and a steam turbine model. Reference: IEEE PES-TR1, 3.2.1.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEGenericHRSGST
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{88FE36EB-97E7-43c7-9374-A5CB616B2BEF}
Class notes
Generic heat-recovery steam generator (HRSG) and a steam turbine model. Reference: IEEE PES-TR1, 3.2.1.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEGenericHRSGST
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
bvi{585479B8-713B-42f0-8B81-95240C4658B7}show detailsdid not existPU [0..1]Steam dynamics constant (Bv). Typical value = 0,316227.
Attribute notes
Steam dynamics constant (Bv). Typical value = 0,316227.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namebv
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{C235B73F-E1D4-4481-9778-0FA79DF8C885}show detailsdid not existPU [0..1]Bypass valve control integral gain (Ki). Typical value = 2.
Attribute notes
Bypass valve control integral gain (Ki). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmi{EACE373F-6951-4002-82A0-D4165DFEF91D}show detailsdid not existPU [0..1]Steam dynamics constant (Km). Typical value = 0,15.
Attribute notes
Steam dynamics constant (Km). Typical value = 0,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{4917E263-C679-4fb5-8173-2E9AE33583B2}show detailsdid not existPU [0..1]Bypass valve control proportional gain (Kp). Typical value = 10.
Attribute notes
Bypass valve control proportional gain (Kp). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
pgtqgi{A20455AE-D8A9-4725-95F8-26E5840461CC}show detailsdid not existString [0..1] (PgtQg).
Attribute notes
(PgtQg).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepgtqg
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
predi{A61DBB16-63EB-46fd-9104-26B9AC647607}show detailsdid not existString [0..1] (Pred).
Attribute notes
(Pred).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepred
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
prefi{48679180-03BC-4a76-B61E-17FA58A220F8}show detailsdid not existPU [0..1]Reference for minimum power (Pref). Typical value = 0,5.
Attribute notes
Reference for minimum power (Pref). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namepref
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qsi{AC1EB13A-78B8-4d31-B6E1-FFE16F0DAC5F}show detailsdid not existPU [0..1]Input flow bias (Qs). Typical value = 0,1.
Attribute notes
Input flow bias (Qs). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqs
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdi{0C878793-F726-4d02-819B-EC2A386F4C38}show detailsdid not existSeconds [0..1]Turbine lag time constant (Td) (>=0). Typical value = 10.
Attribute notes
Turbine lag time constant (Td) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdrumi{D05DBA27-7E4B-4a0b-A9D8-622B4CEB2BA2}show detailsdid not existSeconds [0..1]Steam drum time constant (Tdrum) (>=0). Typical value = 300.
Attribute notes
Steam drum time constant (Tdrum) (>=0). Typical value = 300.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdrum
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tni{9F7B6BED-59AA-4497-9186-33D53F698DC4}show detailsdid not existSeconds [0..1]Turbine lead time constant (Tn) (>=0). Typical value = 3.
Attribute notes
Turbine lead time constant (Tn) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametn
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{EF2239D9-B580-4785-8F4B-A13361448D27}show detailsdid not existActivePower [0..1]Steam turbine rated power (Trate). Typical value = 0.
Attribute notes
Steam turbine rated power (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tvi{8ADAC262-E5B9-4629-BDD4-49A18AD0A7D1}show detailsdid not existSeconds [0..1]Bypass valve time constant (Tv) (>=0). Typical value = 0,5.
Attribute notes
Bypass valve time constant (Tv) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametv
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEGenericHRSGST
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEHydroWCgeni
Class notes
General form of idealized linear turbine-water column model. Reference: IEEE PES-TR1, 4.3, Figure 4-9.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCgen
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{4EA01FB2-B1D0-4ea4-8004-F2A096A5B9AC}
Class notes
General form of idealized linear turbine-water column model. Reference: IEEE PES-TR1, 4.3, Figure 4-9.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCgen
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
a11i{176C98D6-7044-427e-A5CE-7A6B7C0C4AE5}show detailsdid not existFloat [0..1]Partial derivative a11 (a11). Typical value = 0,5.
Attribute notes
Partial derivative a11 (a11). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea11
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
a13i{405AAF6D-EB7A-4aa9-8F95-A03605967772}show detailsdid not existFloat [0..1]Partial derivative a13 (a13). Typical value = 1.
Attribute notes
Partial derivative a13 (a13). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea13
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
a21i{37F72343-C812-40a9-9E9F-A17F4488FB19}show detailsdid not existFloat [0..1]Partial derivative a21 (a21). Typical value = 1,5.
Attribute notes
Partial derivative a21 (a21). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea21
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
a23i{021A8FC7-279F-480e-9D5D-0824A272E593}show detailsdid not existFloat [0..1]Partial derivative a23 (a23). Typical value = 1.
Attribute notes
Partial derivative a23 (a23). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea23
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{4B553271-1127-461b-B37E-816DD26AF3B7}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{AB8364BD-C86E-4a37-97C5-9298F7DC77A2}show detailsdid not existSeconds [0..1]Water starting time constant (Tw) (>=0). Typical value = 0,75.
Attribute notes
Water starting time constant (Tw) (>=0). Typical value = 0,75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCgen
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEHydroWClineari
Class notes
Linear turbine-water column model. Reference: IEEE PES-TR1, 4.3, Figure 4-8.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWClinear
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{4B2CA87C-866B-47d3-9F63-D18A044E6621}
Class notes
Linear turbine-water column model. Reference: IEEE PES-TR1, 4.3, Figure 4-8.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWClinear
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
tratei{BAE7CFCE-03E7-404f-8B52-41AA1070B43D}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{2BFF676C-FA1D-4aab-A811-688C1C3A90B4}show detailsdid not existSeconds [0..1]Water starting time constant (Tw) (>=0). Typical value = 0,75.
Attribute notes
Water starting time constant (Tw) (>=0). Typical value = 0,75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWClinear
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEHydroWCNonLineari
Class notes
Nonlinear turbine-water column model (inelastic) with gate vs. power gain. Reference: IEEE PES-TR1, 4.3, Figure 4-15.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinear
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{398D5EEE-8199-4632-86C2-0CD1AEF0EE6A}
Class notes
Nonlinear turbine-water column model (inelastic) with gate vs. power gain. Reference: IEEE PES-TR1, 4.3, Figure 4-15.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinear
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ati{74943CC3-F2E9-4c29-B83C-BE32D87D337B}show detailsdid not existPU [0..1]Turbine gain (At). Typical value = 1,2.
Attribute notes
Turbine gain (At). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameat
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
dti{CF83A797-E4EF-4c41-BE20-F488D93939B4}show detailsdid not existPU [0..1]Turbine damping factor (Dt). Typical value = 0.
Attribute notes
Turbine damping factor (Dt). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gpmi{D78E3505-9713-4e9b-96BE-D390EC3308F6}show detailsdid not existString [0..1] (GPm).
Attribute notes
(GPm).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namegpm
Scale0
Scopepublic
Staticfalse
TypeString
UpperBound1
Tagged values — changes
BaselineDestination
none
h0i{7A5A9BE0-82FA-4879-954E-C930B73BA19B}show detailsdid not existPU [0..1]Turbine nominal head (H0). Typical value = 1.
Attribute notes
Turbine nominal head (H0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameh0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qnli{9FDB3084-A39B-41db-8D4D-8CB38F71960F}show detailsdid not existPU [0..1]No-load turbine flow at nominal head (Qnl). Typical value = 0,08.
Attribute notes
No-load turbine flow at nominal head (Qnl). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqnl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{FC5995CE-F12B-4838-BCB0-BE3543A9F133}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the gererator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the gererator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{D4524FB2-7849-4f47-B1E1-8D0710C51160}show detailsdid not existSeconds [0..1]Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute notes
Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinear
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEHydroWCNonLinearAi
Class notes
Conventional nonlinear turbine-water column model (inelastic). Reference: IEEE PES-TR1, 4.3, Figure 4-10a.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinearA
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{A4E5429A-8FBF-4a2f-AEE8-AD691EADCB77}
Class notes
Conventional nonlinear turbine-water column model (inelastic). Reference: IEEE PES-TR1, 4.3, Figure 4-10a.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinearA
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ati{238BDC2F-9626-4c7d-ACD9-9182653C7B7F}show detailsdid not existPU [0..1]Turbine gain (At). Typical value = 1,2.
Attribute notes
Turbine gain (At). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameat
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
dti{39B31BE3-7538-46dc-9EF0-13A15FDF0CCD}show detailsdid not existPU [0..1]Turbine damping factor (Dt). Typical value = 0.
Attribute notes
Turbine damping factor (Dt). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
h0i{9685F293-F9BA-4085-9427-97AD2BF21BA6}show detailsdid not existPU [0..1]Turbine head (H0). Typical value = 1.
Attribute notes
Turbine head (H0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameh0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qnli{3CB3CD52-E97E-46a5-AE83-69EBF6CFE26A}show detailsdid not existPU [0..1]No-load flow at nominal head (Qnl). Typical value = 0,08.
Attribute notes
No-load flow at nominal head (Qnl). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqnl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{74C59CED-64A5-4a0c-8BF8-D0CACF5BB1FA}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{8D7F1244-F997-492a-98C1-CA4FD1DE9309}show detailsdid not existSeconds [0..1]Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute notes
Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinearA
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙TurbIEEEHydroWCNonLinearBi
Class notes
Modified nonlinear turbine-water column model (inelastic). Reference: IEEE PES-TR1, 4.3, Figure 4-10b.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinearB
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{80EB5DE0-3584-4a62-AA4C-AE0D7368AA31}
Class notes
Modified nonlinear turbine-water column model (inelastic). Reference: IEEE PES-TR1, 4.3, Figure 4-10b.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameTurbIEEEHydroWCNonLinearB
ParentPackageTurbineGovernorDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ati{2117DD81-51E6-4848-B076-C617EF269767}show detailsdid not existPU [0..1]Turbine gain (At). Typical value = 1,2.
Attribute notes
Turbine gain (At). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameat
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
betai{11D2E9AF-4236-4f0e-8806-7D587BE0864B}show detailsdid not existFloat [0..1]Water pressure coefficient (beta). Typical value = 0,1.
Attribute notes
Water pressure coefficient (beta). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namebeta
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
dti{8BA5F283-5024-4981-A019-76924E0E6ED3}show detailsdid not existPU [0..1]Turbine damping factor (Dt). Typical value = 0.
Attribute notes
Turbine damping factor (Dt). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
h0i{2EB7CAA4-B40A-4886-9A92-D66C3077B2C7}show detailsdid not existPU [0..1]Turbine head (H0). Typical value = 1.
Attribute notes
Turbine head (H0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameh0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qnli{6585126D-B994-40f2-B7F6-0DA64100B694}show detailsdid not existPU [0..1]No-load flow at nominal head (Qnl). Typical value = 0,08.
Attribute notes
No-load flow at nominal head (Qnl). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqnl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tratei{978C3AF4-E3D5-4913-8609-D146CD07864B}show detailsdid not existActivePower [0..1]Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute notes
Turbine rated power (0 => Trate=Prated of the generator) (Trate). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
twi{7DEAB060-0096-4280-A486-55F43989132A}show detailsdid not existSeconds [0..1]Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute notes
Water inertia time constant (Tw) (>=0). Typical value = 0,75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbIEEEHydroWCNonLinearB
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed classes (23)
▶⚙CrossCompoundTurbineGovernorDynamicsi
Class notes (destination, redlined)
Turbine-governor cross-compound function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model. </font>In case the model operates with one synchronous machine, all associations to SynchronousMachineDynamics shall point to the same synchronous machine.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{9C543894-7669-4bd9-B389-C68E4C167F6E}
Class notes (destination, redlined)
Turbine-governor cross-compound function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model. </font>In case the model operates with one synchronous machine, all associations to SynchronousMachineDynamics shall point to the same synchronous machine.
⇄Links
Source end
no changes
Target end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
EndTurbineGovernorDynamicsCrossCompoundTurbineGovernorDynamics
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovSteamIEEETGOV5
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCrossCompoundTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Source end
no changes
Target end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
EndTurbineGovernorDynamicsCrossCompoundTurbineGovernorDynamics
BaselineCrossCompoundTurbineGovernorDynamics role CrossCompoundTurbineGovernorDyanmics [0..1] → SynchronousMachineDynamics role HighPressureSynchronousMachineDynamics [1]
→
DestinationCrossCompoundTurbineGovernorDynamics role CrossCompoundTurbineGovernorDyanmicsCrossCompoundTurbineGovernorDynamics [0..1] → SynchronousMachineDynamics role HighPressureSynchronousMachineDynamics [1]
Source end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
RoleCrossCompoundTurbineGovernorDyanmicsCrossCompoundTurbineGovernorDynamics
Target end
no changes
▶⚙GovCT1i
Class notes (destination, redlined)
General model for any prime mover with a PID governor, used primarily for combustion turbine and combined cycle units. This model can be used to represent a variety of prime movers controlled by PID governors. It is suitable, for example, for the representation of: <ul> <li>gas turbine and single shaft combined cycle turbines</li> </ul> <ul> <li>diesel engines with modern electronic or digital governors </li> </ul> <ul> <li>steam turbines where steam is supplied from a large boiler drum or a large header whose pressure is substantially constant over the period under study</li> <li>simple hydro turbines in dam configurations where the water column length is short and water inertia effects are minimal.</li> </ul> Additional information on this model is available in the 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, 3.1.2.3 pages 3- to 4 (GGOV1).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{EC304C29-08AD-426b-BEBF-8167E8655879}
Class notes (destination, redlined)
General model for any prime mover with a PID governor, used primarily for combustion turbine and combined cycle units. This model can be used to represent a variety of prime movers controlled by PID governors. It is suitable, for example, for the representation of: <ul> <li>gas turbine and single shaft combined cycle turbines</li> </ul> <ul> <li>diesel engines with modern electronic or digital governors </li> </ul> <ul> <li>steam turbines where steam is supplied from a large boiler drum or a large header whose pressure is substantially constant over the period under study</li> <li>simple hydro turbines in dam configurations where the water column length is short and water inertia effects are minimal.</li> </ul> Additional information on this model is available in the 2012 IEEE report, <i><u>Dynamic Models for Turbine-Governors in Power System Studies</u></i>, 3.1.2.3 pages 3- to 4 (GGOV1).
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
deltati{95AC0C6B-7DE6-4c80-A148-6182853BCB77}show detailsdid not existFloat [0..1]Correction factor (delta t) to adapt the unit of the acceleration limiter gain (Ka) from pu/s to pu. Default value is 1 if the attribute is not exchanged.
Attribute notes
Correction factor (delta t) to adapt the unit of the acceleration limiter gain (Ka) from pu/s to pu. Default value is 1 if the attribute is not exchanged.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedeltat
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovCT2i
Class notes
General governor with frequency-dependent fuel flow limit. This model is a modification of the GovCT1<b> </b>model in order to represent the frequency-dependent fuel flow limit of a specific gas turbine manufacturer.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{0A73B225-89A2-4f10-A1F2-E0FEB59F2980}
Class notes
General governor with frequency-dependent fuel flow limit. This model is a modification of the GovCT1<b> </b>model in order to represent the frequency-dependent fuel flow limit of a specific gas turbine manufacturer.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
deltati{16ADC17B-F173-475c-959C-2E7972C7F15B}show detailsdid not existFloat [0..1]Correction factor (delta t) to adapt the unit of the acceleration limiter gain (Ka) from pu/s to pu. Default value is 1 if the attribute is not exchanged.
Attribute notes
Correction factor (delta t) to adapt the unit of the acceleration limiter gain (Ka) from pu/s to pu. Default value is 1 if the attribute is not exchanged.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namedeltat
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovGAST2i
Class notes
Gas turbine.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C2365E2F-CF56-49c5-A63D-1736696A686A}
Class notes
Gas turbine.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
cf2i{189FE130-752A-47d1-A143-C0AEA8CBEC8A}show detailsPU [0..1]PU [0..1]Coefficient defining fuel flow where power output is 0 % (<i>Cf2</i>). Synchronous but no output. Typically 0,23 x K<sub>hhv</sub> (23 % fuel flow).
Attribute notes (destination, redlined)
Coefficient defining fuel flow where power output is 0 % (<i>Cf2</i>). Synchronous but no output. Typically 0,23 x K<sub>hhv</sub> (23 % fuel flow).
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovGAST3i
Class notes
Generic turbogas with acceleration and temperature controller.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{153BECCA-9710-4d48-8BEC-30215D859B61}
Class notes
Generic turbogas with acceleration and temperature controller.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{72241B01-A867-4ee3-A325-38AF8AECE93C}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovGAST4i
Class notes
Generic turbogas.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{77197C40-C093-43f7-B2FA-434AC89EE019}
Class notes
Generic turbogas.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{B11C3689-4600-48be-AD53-2A0B61728F05}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovGASTWDi
Class notes (destination, redlined)
Woodward™ gas turbine governor. [Footnote: Woodward gas turbines are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.] .
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{659A678F-7407-4f04-82AE-D55250A64A93}
Class notes (destination, redlined)
Woodward™ gas turbine governor. [Footnote: Woodward gas turbines are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.] .
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ai{E9B2E67F-148B-45f5-A20F-290EAC2978B6}show detailsFloat [0..1]Float [0..1]Valve positioner (<i>A</i>). Typical value = 1.
Attribute notes (destination, redlined)
Valve positioner (<i>A</i>). Typical value = 1.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
af1i{BAD3FD6B-543F-439f-9916-B601A0F797C7}show detailsPU [0..1]PU [0..1]Exhaust temperature parameter (<i>Af1</i>). Typical value = 700.
Attribute notes (destination, redlined)
Exhaust temperature parameter (<i>Af1</i>). Typical value = 700.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
af2i{8F604F6A-68EC-440f-91F8-1903348F2EED}show detailsPU [0..1]PU [0..1]Coefficient equal to 0,5(1-speed) (<i>Af2</i>). Typical value = -0,299.
Attribute notes (destination, redlined)
Coefficient equal to 0,5(1-speed) (<i>Af2</i>). Typical value = -0,299.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
bi{E1B8747C-D70F-4508-8F4B-E1DF1E2C7281}show detailsFloat [0..1]Float [0..1]Valve positioner (<i>B</i>). Typical value = 0,5.
Attribute notes (destination, redlined)
Valve positioner (<i>B</i>). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
bf1i{0DE33289-2AED-4ef1-A029-0FF07549AE7B}show detailsPU [0..1]PU [0..1](<i>Bf1</i>). <i>Bf1</i> = <i>E</i>(1-<i>w</i>) where <i>E</i> (speed sensitivity coefficient) is 0,55 to 0,65 x <i>Tr</i>. Typical value = 550.
Attribute notes (destination, redlined)
(<i>Bf1</i>). <i>Bf1</i> = <i>E</i>(1-<i>w</i>) where <i>E</i> (speed sensitivity coefficient) is 0,55 to 0,65 x <i>Tr</i>. Typical value = 550.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
bf2i{90C76F60-AA06-47bf-A995-F69246EA0A22}show detailsPU [0..1]PU [0..1]Turbine torque coefficient K<sub>hhv</sub> (depends on heating value of fuel stream in combustion chamber) (<i>Bf2</i>). Typical value = 1,3.
Attribute notes (destination, redlined)
Turbine torque coefficient K<sub>hhv</sub> (depends on heating value of fuel stream in combustion chamber) (<i>Bf2</i>). Typical value = 1,3.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
ci{96C07468-DA80-4933-A3E9-A775511108A5}show detailsFloat [0..1]Float [0..1]Valve positioner (<i>C</i>). Typical value = 1.
Attribute notes (destination, redlined)
Valve positioner (<i>C</i>). Typical value = 1.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
cf2i{9938F6C5-6F70-4a1b-8FF1-783310424DEC}show detailsPU [0..1]PU [0..1]Coefficient defining fuel flow where power output is 0 % (<i>Cf2</i>). Synchronous but no output. Typically 0,23 x K<sub>hhv </sub>(23 % fuel flow). Typical value = 0,5.
Attribute notes (destination, redlined)
Coefficient defining fuel flow where power output is 0 % (<i>Cf2</i>). Synchronous but no output. Typically 0,23 x K<sub>hhv </sub>(23 % fuel flow). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
ecri{E2649AC7-0447-4721-9286-0CD92F82CCDA}show detailsSeconds [0..1]Seconds [0..1]Combustion reaction time delay (<i>Ecr</i>) (>= 0). Typical value = 0,01.
Attribute notes (destination, redlined)
Combustion reaction time delay (<i>Ecr</i>) (>= 0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
etdi{2F025F5E-0E6E-46d0-993B-12FD2DAB66E5}show detailsSeconds [0..1]Seconds [0..1]Turbine and exhaust delay (<i>Etd</i>) (>= 0). Typical value = 0,02.
Attribute notes (destination, redlined)
Turbine and exhaust delay (<i>Etd</i>) (>= 0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
k3i{1BF22E14-F29C-4c06-BA62-F729E97EC481}show detailsPU [0..1]PU [0..1]Ratio of fuel adjustment (<i>K3</i>). Typical value = 0,77.
Attribute notes (destination, redlined)
Ratio of fuel adjustment (<i>K3</i>). Typical value = 0,77.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
k4i{062F1807-AE26-43a1-A4EB-CA47829BD673}show detailsPU [0..1]PU [0..1]Gain of radiation shield (<i>K4</i>). Typical value = 0,8.
Attribute notes (destination, redlined)
Gain of radiation shield (<i>K4</i>). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
k5i{65F461A9-A23A-45d1-AF07-6636C1A51130}show detailsPU [0..1]PU [0..1]Gain of radiation shield (<i>K5</i>). Typical value = 0,2.
Attribute notes (destination, redlined)
Gain of radiation shield (<i>K5</i>). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
k6i{25B6A870-C68F-4285-9372-FF25F758DCAE}show detailsPU [0..1]PU [0..1]Minimum fuel flow (<i>K6</i>). Typical value = 0,23.
Attribute notes (destination, redlined)
Minimum fuel flow (<i>K6</i>). Typical value = 0,23.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kdi{3CD8EA5C-A3F3-464d-8F75-C955E8B5D411}show detailsPU [0..1]PU [0..1]Drop governor gain (<i>Kd</i>). Typical value = 5.
Attribute notes (destination, redlined)
Drop governor gain (<i>Kd</i>). Typical value = 5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kdroopi{53BE233F-E597-435e-9EE8-32762D5769E2}show detailsPU [0..1]PU [0..1]Permanent droop (<i>Kdroop</i>) (>= 0). Typical value = 0,05.
Attribute notes (destination, redlined)
Permanent droop (<i>Kdroop</i>) (>= 0). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kfi{18034879-9FB3-4d8d-B4AC-B70FF2FB3DC7}show detailsPU [0..1]PU [0..1]Fuel system feedback (<i>Kf</i>). Typical value = 0.
Attribute notes (destination, redlined)
Fuel system feedback (<i>Kf</i>). Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kii{06B18E6E-3F42-45f8-B5AC-CFA014647CB1}show detailsPU [0..1]PU [0..1]Isochronous Governor Gain (<i>Ki</i>). Typical value = 5.
Attribute notes (destination, redlined)
Isochronous Governor Gain (<i>Ki</i>). Typical value = 5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kpi{DF1A90F2-14A2-4959-BD6B-91F3FDF6721C}show detailsPU [0..1]PU [0..1]PID proportional gain (<i>Kp</i>). Typical value = 15.
Attribute notes (destination, redlined)
PID proportional gain (<i>Kp</i>). Typical value = 15.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
mwbasei{AD1058DB-3580-425e-B7B4-E620AF7591E9}show detailsActivePower [0..1]ActivePower [0..1]Base for power values, turbine rated power (<i>MWbase</i>) (> 0). Unit = MW. Typical value = 0.
Attribute notes (destination, redlined)
Base for power values, turbine rated power (<i>MWbase</i>) (> 0). Unit = MW. Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
ti{4496FC4C-2076-4835-B622-0B5A8D831F1B}show detailsSeconds [0..1]Seconds [0..1]Fuel control time constant (<i>T</i>) (>= 0). Typical value = 0.
Attribute notes (destination, redlined)
Fuel control time constant (<i>T</i>) (>= 0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
t3i{4F3EC56D-F128-4311-9955-FC1FD2B3109A}show detailsSeconds [0..1]Seconds [0..1]Radiation shield time constant (<i>T3</i>) (>= 0). Typical value = 15.
Attribute notes (destination, redlined)
Radiation shield time constant (<i>T3</i>) (>= 0). Typical value = 15.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
t4i{BF2AFDA2-E1A3-4d2a-BD38-29DE53C2B114}show detailsSeconds [0..1]Seconds [0..1]Thermocouple time constant (<i>T4</i>) (>= 0). Typical value = 2,5.
Attribute notes (destination, redlined)
Thermocouple time constant (<i>T4</i>) (>= 0). Typical value = 2,5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
t5i{65E05FB4-5E10-4954-AB84-0D5158770FC3}show detailsSeconds [0..1]Seconds [0..1]Temperature control time constant (<i>T5</i>) (>= 0). Typical value = 3.
Attribute notes (destination, redlined)
Temperature control time constant (<i>T5</i>) (>= 0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tci{8989E83E-350D-412e-ABFF-98F4620A653A}show detailsTemperature [0..1]Temperature [0..1]Temperature control (<i>Tc</i>). Typical value = 955.
Attribute notes (destination, redlined)
Temperature control (<i>Tc</i>). Typical value = 955.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tcdi{7AD2404F-9868-475e-AABD-B43E58786C38}show detailsSeconds [0..1]Seconds [0..1]Compressor discharge time constant (<i>Tcd</i>) (>= 0). Typical value = 0,1.
Attribute notes (destination, redlined)
Compressor discharge time constant (<i>Tcd</i>) (>= 0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tdi{1794CD83-3D07-4080-8914-B555130719A7}show detailsSeconds [0..1]Seconds [0..1]Power transducer time constant (<i>Td</i>) (>= 0). Typical value = 0,2.
Attribute notes (destination, redlined)
Power transducer time constant (<i>Td</i>) (>= 0). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tfi{68DE0768-EB04-4763-AC7A-F51498FE937D}show detailsSeconds [0..1]Seconds [0..1]Fuel system time constant (<i>Tf</i>) (>= 0). Typical value = 0,4.
Attribute notes (destination, redlined)
Fuel system time constant (<i>Tf</i>) (>= 0). Typical value = 0,4.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tmaxi{A2026E04-2E46-4d23-80A9-26CB247809C0}show detailsPU [0..1]PU [0..1]Maximum Turbine limit (<i>Tmax</i>) (> GovGASTWD.tmin). Typical value = 1.
Attribute notes (destination, redlined)
Maximum Turbine limit (<i>Tmax</i>) (> GovGASTWD.tmin). Typical value = 1.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tmini{A222E8D5-F51E-4667-947A-E3692AF0E7E7}show detailsPU [0..1]PU [0..1]Minimum turbine limit (<i>Tmin</i>) (< GovGASTWD.tmax). Typical value = 0.
Attribute notes (destination, redlined)
Minimum turbine limit (<i>Tmin</i>) (< GovGASTWD.tmax). Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tri{B2CC37AB-1ED9-4fb3-82E1-13EB499510E7}show detailsTemperature [0..1]Temperature [0..1]Rated temperature (<i>Tr</i>). Typical value = 955.
Attribute notes (destination, redlined)
Rated temperature (<i>Tr</i>). Typical value = 955.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tratei{775688D9-771C-42f5-ADFB-94FBF83CC532}show detailsActivePower [0..1]removed from model
Attribute notes (baseline)
Turbine rating (<i>Trate</i>). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
Nametrate
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
tti{F80ED7EC-E304-4138-962C-26E978B77294}show detailsSeconds [0..1]Seconds [0..1]Temperature controller integration rate (<i>Tt</i>) (>= 0). Typical value = 400.
Attribute notes (destination, redlined)
Temperature controller integration rate (<i>Tt</i>) (>= 0). Typical value = 400.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovHydro1i
Class notes
Basic hydro turbine governor.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{43B50912-F9F9-458f-AFDF-36ADB06FB9A6}
Class notes
Basic hydro turbine governor.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
gmaxi{9446DBF8-C9AF-401c-B824-104D8ABBCBD7}show detailsPU [0..1]PU [0..1]Maximum gate opening (<i>Gmax</i>) (> 0 and > GovHydroGovHydro1.gmin). Typical value = 1.
Attribute notes (destination, redlined)
Maximum gate opening (<i>Gmax</i>) (> 0 and > GovHydroGovHydro1.gmin). Typical value = 1.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
velmi{DE782CB5-7653-4c66-A929-C9019477CF51}show detailsFloat [0..1]Float [0..1]Maximum gate velocity (<i>Vlem</i>) (> 0). The limit is applied on the state variable of the integrator. Typical value = 0,2.
Attribute notes (destination, redlined)
Maximum gate velocity (<i>Vlem</i>) (> 0). The limit is applied on the state variable of the integrator. Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovHydro4i
Class notes (destination, redlined)
Hydro turbine and governor. Represents plants with straight-forward penstock configurations and hydraulic governors of the traditional 'dashpot' type. This model can be used to represent simple, Francis/Pelton or Kaplan turbines.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{4E8A3071-7AC6-490c-A12C-5BD140E8D992}
Class notes (destination, redlined)
Hydro turbine and governor. Represents plants with straight-forward penstock configurations and hydraulic governors of the traditional 'dashpot' type. This model can be used to represent simple, Francis/Pelton or Kaplan turbines.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
uci{2F511A10-938D-4c28-BD41-6A175D8D353C}show detailsFloat [0..1]Float [0..1]Max gate closing velocity (<i>Uc</i>) (< 0). Typical value = -0,2.
Attribute notes (destination, redlined)
Max gate closing velocity (<i>Uc</i>) (< 0). Typical value = -0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
uoi{ED6AEE7C-0928-4df9-86D1-0BBB70F8EBE1}show detailsFloat [0..1]Float [0..1]Max gate opening velocity (<i>Uo</i>) (> 0). Typical value = 0,2.
Attribute notes (destination, redlined)
Max gate opening velocity (<i>Uo</i>) (> 0). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovHydroDDi
Class notes
Double derivative hydro governor and turbine.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{0767E4BD-4883-4280-85D8-D84895677D6E}
Class notes
Double derivative hydro governor and turbine.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
pmini{21E787D0-EE26-4c1e-A519-45645C9BD889}show detailsPU [0..1]PU [0..1]Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (>< GovHydroDD.pmax). Typical value = 0.
Attribute notes (destination, redlined)
Minimum gate opening, PU of <i>MWbase</i> (<i>Pmin</i>) (>< GovHydroDD.pmax). Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovHydroFrancisi
Class notes
Detailed hydro unit - Francis model. This model can be used to represent three types of governors. A schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton, is provided in the DetailedHydroModelHydraulicSystem diagram.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{340132B0-5FB9-4bc4-B48C-ED58E4386135}
Class notes
Detailed hydro unit - Francis model. This model can be used to represent three types of governors. A schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton, is provided in the DetailedHydroModelHydraulicSystem diagram.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{AFD8821F-970F-4953-B43F-9C1FB218F190}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovHydroPeltoni
Class notes
Detailed hydro unit - Pelton model. This model can be used to represent the dynamic related to water tunnel and surge chamber. The DetailedHydroModelHydraulicSystem diagram, located under the GovHydroFrancis class, provides a schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{93F7CE4F-A7AD-4c0a-A714-1F6BB59E4CF2}
Class notes
Detailed hydro unit - Pelton model. This model can be used to represent the dynamic related to water tunnel and surge chamber. The DetailedHydroModelHydraulicSystem diagram, located under the GovHydroFrancis class, provides a schematic of the hydraulic system of detailed hydro unit models, such as Francis and Pelton.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{D4AE3321-45BD-445f-9FE1-7B54571153E6}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovHydroPID2i
Class notes (destination, redlined)
Hydro turbine and governor. Represents plants with straightforward penstock configurations and "three term" electro-hydraulic governors (i.e. Woodward<sup>TM</sup> electronic). [Footnote: Woodward electronic governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{7BD580D8-6A60-452c-A8B8-3D5C4376B87A}
Class notes (destination, redlined)
Hydro turbine and governor. Represents plants with straightforward penstock configurations and "three term" electro-hydraulic governors (i.e. Woodward<sup>TM</sup> electronic). [Footnote: Woodward electronic governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
g3i{FFEE1F3A-A081-4dec-826D-FB4527175C75}show detailsdid not existPU [0..1]Intermediate gate opening (<i>G3</i>). Typical value = 0.
Attribute notes
Intermediate gate opening (<i>G3</i>). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameg3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
gmini{C638F1C1-57F1-498a-91CE-56CAA8F479A9}show detailsPU [0..1]PU [0..1]Minimum gate opening (<i>Gmin</i>) (>< GovHydroPID2.gmax). Typical value = 0.
Attribute notes (destination, redlined)
Minimum gate opening (<i>Gmin</i>) (>< GovHydroPID2.gmax). Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
p0i{5590CAFB-71F8-4da8-889C-D49355E8C1F0}show detailsdid not existPU [0..1]Power at gate opening <i>G0</i> (<i>P0</i>). Typical value = 0.
Attribute notes
Power at gate opening <i>G0</i> (<i>P0</i>). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovHydroWEHi
Class notes (destination, redlined)
Woodward<sup>TM </sup>electric hydro governor. [Footnote: Woodward electric hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{44F7E8EE-7150-4a8b-B451-EB756B45B2C3}
Class notes (destination, redlined)
Woodward<sup>TM </sup>electric hydro governor. [Footnote: Woodward electric hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
fp1i{1916E846-ED5F-4813-BA63-8C3EFDFE76B5}show detailsPU [0..1]PU [0..1]Flow P1 (<i>Fp1</i>). Turbine flow value for point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P1 (<i>Fp1</i>). Turbine flow value for point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp10i{4EA2E0CD-8F91-4aac-BECF-170592984B28}show detailsPU [0..1]PU [0..1]Flow P10 (<i>Fp10</i>). Turbine flow value for point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P10 (<i>Fp10</i>). Turbine flow value for point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp2i{7E25342F-C381-4549-8E29-7298D378987F}show detailsPU [0..1]PU [0..1]Flow P2 (<i>Fp2</i>). Turbine flow value for point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P2 (<i>Fp2</i>). Turbine flow value for point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp3i{78D35C8A-4CE5-4c92-A35D-AB0CFB535856}show detailsPU [0..1]PU [0..1]Flow P3 (<i>Fp3</i>). Turbine flow value for point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P3 (<i>Fp3</i>). Turbine flow value for point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp4i{21066FBB-3F5E-492c-86D7-A9046294A620}show detailsPU [0..1]PU [0..1]Flow P4 (<i>Fp4</i>). Turbine flow value for point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P4 (<i>Fp4</i>). Turbine flow value for point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp5i{7DED80F8-F034-49c5-8687-FC3838D5885E}show detailsPU [0..1]PU [0..1]Flow P5 (<i>Fp5</i>). Turbine flow value for point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P5 (<i>Fp5</i>). Turbine flow value for point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp6i{344C9FCA-23FE-4e7f-A035-07A5CD93B8DA}show detailsPU [0..1]PU [0..1]Flow P6 (<i>Fp6</i>). Turbine flow value for point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P6 (<i>Fp6</i>). Turbine flow value for point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp7i{B99854AF-E5A3-41a0-91F0-1EDE86523725}show detailsPU [0..1]PU [0..1]Flow P7 (<i>Fp7</i>). Turbine flow value for point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P7 (<i>Fp7</i>). Turbine flow value for point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp8i{2B40A8AB-32F3-41b5-A657-FDBDAB8A14E3}show detailsPU [0..1]PU [0..1]Flow P8 (<i>Fp8</i>). Turbine flow value for point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P8 (<i>Fp8</i>). Turbine flow value for point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
fp9i{BD244D13-5805-4f39-A0D4-6AB400B42DFA}show detailsPU [0..1]PU [0..1]Flow P9 (<i>Fp9</i>). Turbine flow value for point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Flow P9 (<i>Fp9</i>). Turbine flow value for point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss1i{7D878D2D-2290-494e-ABE1-2E30138DBADA}show detailsPU [0..1]PU [0..1]Pmss flow P1 (<i>Pmss1</i>). Mechanical power output for turbine flow point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P1 (<i>Pmss1</i>). Mechanical power output for turbine flow point 1 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss10i{D1502FC1-74AE-4abe-9D8B-3A91C9B34B75}show detailsPU [0..1]PU [0..1]Pmss flow P10 (<i>Pmss10</i>). Mechanical power output for turbine flow point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P10 (<i>Pmss10</i>). Mechanical power output for turbine flow point 10 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss2i{93ADB708-1FCF-46a7-A1FE-84B92459F065}show detailsPU [0..1]PU [0..1]Pmss flow P2 (<i>Pmss2</i>). Mechanical power output for turbine flow point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P2 (<i>Pmss2</i>). Mechanical power output for turbine flow point 2 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss3i{CEC08DD4-FC8C-4e17-9617-C88CF79F807C}show detailsPU [0..1]PU [0..1]Pmss flow P3 (<i>Pmss3</i>). Mechanical power output for turbine flow point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P3 (<i>Pmss3</i>). Mechanical power output for turbine flow point 3 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss4i{375B46F3-DFA0-48be-8747-B26DED2033EB}show detailsPU [0..1]PU [0..1]Pmss flow P4 (<i>Pmss4</i>). Mechanical power output for turbine flow point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P4 (<i>Pmss4</i>). Mechanical power output for turbine flow point 4 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss5i{569E9FF0-4F73-4459-BC27-4C496AD9EA29}show detailsPU [0..1]PU [0..1]Pmss flow P5 (<i>Pmss5</i>). Mechanical power output for turbine flow point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P5 (<i>Pmss5</i>). Mechanical power output for turbine flow point 5 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss6i{7515B1CA-A07C-4ee5-8977-871CAAF88680}show detailsPU [0..1]PU [0..1]Pmss flow P6 (<i>Pmss6</i>). Mechanical power output for turbine flow point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P6 (<i>Pmss6</i>). Mechanical power output for turbine flow point 6 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss7i{C7FE804F-AB3E-41fd-B89C-259FED97771C}show detailsPU [0..1]PU [0..1]Pmss flow P7 (<i>Pmss7</i>). Mechanical power output for turbine flow point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P7 (<i>Pmss7</i>). Mechanical power output for turbine flow point 7 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss8i{0021E92F-92DC-4c3b-8AF2-459A6CD9859C}show detailsPU [0..1]PU [0..1]Pmss flow P8 (<i>Pmss8</i>). Mechanical power output for turbine flow point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P8 (<i>Pmss8</i>). Mechanical power output for turbine flow point 8 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
pmss9i{9F0CD115-B416-4c42-AC39-07560AE20E0D}show detailsPU [0..1]PU [0..1]Pmss flow P9 (<i>Pmss9</i>). Mechanical power output for turbine flow point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute notes (destination, redlined)
Pmss flow P9 (<i>Pmss9</i>). Mechanical power output for turbine flow point 9 for lookup table representing PU mechanical power on machine MVA rating as a function of turbine flow.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovHydroWPIDi
Class notes (destination, redlined)
Woodward<sup>TM</sup> PID hydro governor. [Footnote: Woodward PID hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{61178980-5C8E-4adf-925A-DF8A56CCE23B}
Class notes (destination, redlined)
Woodward<sup>TM</sup> PID hydro governor. [Footnote: Woodward PID hydro governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
regi{943CF738-EE1C-47da-A25F-0C2EEC63695D}show detailsPU [0..1]PU [0..1]Permanent drop (<i>Reg</i>) (>=0).
Attribute notes (destination, redlined)
Permanent drop (<i>Reg</i>) (>=0).
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙GovSteam1i
Class notes
Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband and nonlinear valve gain added).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{05E9615F-2E7C-44a0-BB2E-93B6EB601232}
Class notes
Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband and nonlinear valve gain added).
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{11EA8F80-CAD5-44e3-8893-3FBF11D33D5F}show detailsActivePower [0..1]ActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute notes (destination, redlined)
Base for power values (<i>MWbase</i>) (> 0). Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
mwbaseLPi{DA7110A6-BA79-4e51-8FED-B8BBAFB2A63F}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamemwbaseLP
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Source end
no changes
Target end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
EndTurbineGovernorDynamicsCrossCompoundTurbineGovernorDynamics
▶⚙GovSteam2i
Class notes
Simplified governor.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{21648324-C0D1-4125-855B-CCCA46600E7B}
Class notes
Simplified governor.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{4FE1F56D-B68F-4226-A526-F049EC2BB6EC}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovSteamBBi
Class notes (destination, redlined)
European governor model. Brown Boveri (BB) steam turbine governor model.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{BAF42F15-B5DF-4b1f-B240-5A70C71826A4}
Class notes (destination, redlined)
European governor model. Brown Boveri (BB) steam turbine governor model.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{10059372-81D7-4e2f-B335-F0890E0BAAE2}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovSteamCCi
Class notes
Cross compound turbine governor. Unlike tandem compound units, cross compound units are not on the same shaft.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{710F836E-E997-4363-8621-0F02146A82A9}
Class notes
Cross compound turbine governor. Unlike tandem compound units, cross compound units are not on the same shaft.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{7D26F55F-866C-4dc1-9929-4475EF721953}show detailsActivePower [0..1]ActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute notes (destination, redlined)
Base for power values (<i>MWbase</i>) (> 0). Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
mwbaseLPi{1F3C8B7E-A3AA-4e75-AA22-DACF523681C1}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamemwbaseLP
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovSteamFV4i
Class notes
Detailed electro-hydraulic governor for steam unit.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{5ACC759A-302F-4057-9506-893267597F7F}
Class notes
Detailed electro-hydraulic governor for steam unit.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{42BBEA35-BD7B-4a76-8859-5BFB14B12AFF}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0). Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemwbase
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙GovSteamIEEE1i
Class notes
IEEE steam turbine governor model. Ref<font color="#0f0f0f">erence: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, <i><u>Dynamic Models for Steam and Hydro Turbines in Power System Studies</u></i>, page 1904.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{0C56115D-6698-4d80-ACEC-59C9609E8EB6}
Class notes
IEEE steam turbine governor model. Ref<font color="#0f0f0f">erence: IEEE Transactions on Power Apparatus and Systems, November/December 1973, Volume PAS-92, Number 6, <i><u>Dynamic Models for Steam and Hydro Turbines in Power System Studies</u></i>, page 1904.</font>
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mwbasei{D7E35874-9E7E-401b-8C00-EFF8CE6D581B}show detailsActivePower [0..1]ActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0)<i>. </i>Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute notes (destination, redlined)
Base for power values (<i>MWbase</i>) (> 0)<i>. </i>Used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the high pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
mwbaseLPi{42EEBD4F-BC37-431f-B746-4A992FE371BA}show detailsdid not existActivePower [0..1]Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute notes
Base for power values (<i>MWbase</i>) (> 0)<i>.</i> It is not used when single synchronous machine is connected. In cases where two synchronous machines are connected this attribute is used for the low pressure unit. Unit = MW.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamemwbaseLP
Scale0
Scopepublic
Staticfalse
TypeActivePower
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Source end
no changes
Target end — CrossCompoundTurbineGovernorDynamics
BaselineDestination
EndTurbineGovernorDynamicsCrossCompoundTurbineGovernorDynamics
▶⚙GovSteamSGOi
Class notes
Simplified steam turbine governor.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{EEEBBC29-3B6E-49a6-A1C1-354A867CE94F}
Class notes
Simplified steam turbine governor.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
pmini{4C92810B-55D6-4f56-B1FD-381DF7F8F6E7}show detailsSeconds [0..1]PU [0..1]Lower power limit (<i>Pmin</i>) (>= 0 and < GovSteamSGO.pmax).
Attribute notes
Lower power limit (<i>Pmin</i>) (>= 0 and < GovSteamSGO.pmax).
Attribute metadata — changes
BaselineDestination
TypeSecondsPU
Tagged values — changes
BaselineDestination
no changes
▶⚙TurbineGovernorDynamicsi
Class notes
Turbine-governor function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C759C48A-48F3-4038-8572-625367012530}
Class notes
Turbine-governor function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndSteamTurbineGeneratorDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndCombinedCycleGasTurbineDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndHydroWaterColumnDynamics
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndGovSteamIEEEG1Aug
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndTurbineGovernorDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Added diagrams (2)
▶▦GasTurbineGovernorDynamicsi
Diagram notes
This diagram shows dynamic standard model gaz turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata — changes
BaselineDestination
Authortsaxton
CreatedDate2021-03-21 06:44:33
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:56:19
NameGasTurbineGovernorDynamics
PackageEAPK_40DA7439_D5DD_4608_85C0_87CF5444B24E
ParentPackageTurbineGovernorDynamics
ADDED{3639F204-9BE3-448b-A437-52099DA95456}
Diagram notes
This diagram shows dynamic standard model gaz turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
▤Metadata
BaselineDestination
Authortsaxton
CreatedDate2021-03-21 06:44:33
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:56:19
NameGasTurbineGovernorDynamics
PackageEAPK_40DA7439_D5DD_4608_85C0_87CF5444B24E
ParentPackageTurbineGovernorDynamics
▦Diagram
Baseline
Diagram did not exist in the baseline model.
Destination
GasTurbineGovernorDynamics (destination)
▶▦HydroTurbineGovernorDynamicsi
Diagram notes
This diagram shows dynamic standard model hydro turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata — changes
BaselineDestination
Authortsaxton
CreatedDate2021-03-21 06:45:04
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:56:13
NameHydroTurbineGovernorDynamics
PackageEAPK_40DA7439_D5DD_4608_85C0_87CF5444B24E
ParentPackageTurbineGovernorDynamics
ADDED{5DD835FF-3AB1-450d-9050-A786FC349923}
Diagram notes
This diagram shows dynamic standard model hydro turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
▤Metadata
BaselineDestination
Authortsaxton
CreatedDate2021-03-21 06:45:04
DiagramTypeClassDiagram
ModifiedDate2022-03-18 21:56:13
NameHydroTurbineGovernorDynamics
PackageEAPK_40DA7439_D5DD_4608_85C0_87CF5444B24E
ParentPackageTurbineGovernorDynamics
▦Diagram
Baseline
Diagram did not exist in the baseline model.
Destination
HydroTurbineGovernorDynamics (destination)
Changed diagrams (44)
▶▦DetailedHydroModelHydraulicSystemi
Diagram notes
This diagram illustrates the detailed hydro model of a hydraulic system.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:52:44
CHANGED{5CD3330F-E877-4c51-8B59-11B821110962}
Diagram notes
This diagram illustrates the detailed hydro model of a hydraulic system.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:52:44
Diagram 'DetailedHydroModelHydraulicSystem' has no other changes. The shows its notes and every changed property.
▶▦GovCT1i
Diagram notes (destination, redlined)
This diagram describes the GovCT1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>The range of fuel valve travel and of fuel flow is unity. Thus the largest possible value of <i>Vmax</i> is 1,0 and the smallest possible value of <i>Vmin</i> is zero. <i>Vmax</i> can, however, be reduced below unity to represent a loading limit imposed by the operator or a supervisory control system. For gas turbines <i>Vmin</i> should normally be greater than zero and less than <i>Wfnl</i> to represent a minimum firing limit. The value of the fuel flow at maximum output shall be less than, or equal to unity, depending on the value of <i>Kturb</i>.</li> <li>The load limiter module can be used to impose a maximum output limit such as an exhaust temperature limit. To do this the time constant <i>Tfload </i>should be set to represent the time constant in the measurement of temperature (or other signal), and the gains of the limiter, <i>Kpload </i>and <i>Kiload</i>, should be set to give prompt stable control when on limit. The load limit can be deactivated by setting the parameter <i>Ldref </i>to a high value.</li> <li>This model includes a simple representation of a supervisory load controller. This controller is active if the parameter <i>Kimw</i> is non-zero. The load controller is a slow acting reset loop that adjusts the speed/load reference of the turbine governor to hold the electrical power output of the unit at its initial condition value. This value is stored in the parameter <i>Pmwset</i> (which equals <i>Pe</i>, initial generated power) when the model is initialized, and can be changed thereafter. The load controller shall be adjusted to respond gently relative to the speed governor.</li> <li>The parameters <i>Aset</i>, <i>Ka</i>, and <i>Ta</i> describe an acceleration limiter. <i>Ta</i> shall be non-zero, but the acceleration limiter can be disabled by setting <i>Aset </i>to a large value, such as 1.</li> <li>The parameters <i>Tsa</i> and <i>Tsb</i> are provided to augment the exhaust gas temperature measurement subsystem in gas turbines. For example, they can be set to values such as 4,0 and 5,0, to represent the ‘radiation shield’ element of large gas turbines.</li> <li>The parameters <i>Rup</i> and <i>Rdown</i> specify the maximum rate of increase and decrease of the output of the load limit controller (<i>Kpload</i> /<i> Kiload</i>). These parameters should normally be set, or defaulted to 99 / -99, but can be given particular values to represent the temperature limit controls of some General Electric<sup>TM</sup> heavy-duty engine controls. [Footnote: GE heavy-duty engine controls are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]</li> <li>The fuel flow command <i>fsr </i>is determined by whichever is lowest of <i>fsrt</i>, <i>fsra</i>, and <i>fsrn</i>. Although not explicitly shown in the GovCT1 diagram, the signals that are not in control track <i>fsr</i> so that they do not “windup” beyond that value. This represents GE gas turbine control practice but might not be true for other controller designs.</li> <li>As shown in the GovCT1 diagram, when <i>Kpgov</i> is non-zero, the governor PI control is implemented to “track” <i>fsr</i> to prevent windup when <i>fsr</i> is limited by another signal (<i>fsrt</i>, <i>fsra</i>) or <i>Vmax</i>/<i>Vmi</i>n. If <i>Kpgov</i> is zero, the integral path is implemented directly. The same applies to the load limiter PI control with regard to <i>Kpload</i>.</li> <li>TheIn cases parameterwhere <i>delta tDm</i> inequals the0 block diagram is the simulation<i>Dm</i> timeloop step. It is not exchanged with the datasetactive. In cases where applications are using variable time step the results of the simulations could be different. In such situations the application applies a default value which is 0,001.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-08 09:14:252022-03-18 21:55:30
CHANGED{60B40F19-5A47-43ea-A012-81B1DD2003D6}
Diagram notes (destination, redlined)
This diagram describes the GovCT1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>The range of fuel valve travel and of fuel flow is unity. Thus the largest possible value of <i>Vmax</i> is 1,0 and the smallest possible value of <i>Vmin</i> is zero. <i>Vmax</i> can, however, be reduced below unity to represent a loading limit imposed by the operator or a supervisory control system. For gas turbines <i>Vmin</i> should normally be greater than zero and less than <i>Wfnl</i> to represent a minimum firing limit. The value of the fuel flow at maximum output shall be less than, or equal to unity, depending on the value of <i>Kturb</i>.</li> <li>The load limiter module can be used to impose a maximum output limit such as an exhaust temperature limit. To do this the time constant <i>Tfload </i>should be set to represent the time constant in the measurement of temperature (or other signal), and the gains of the limiter, <i>Kpload </i>and <i>Kiload</i>, should be set to give prompt stable control when on limit. The load limit can be deactivated by setting the parameter <i>Ldref </i>to a high value.</li> <li>This model includes a simple representation of a supervisory load controller. This controller is active if the parameter <i>Kimw</i> is non-zero. The load controller is a slow acting reset loop that adjusts the speed/load reference of the turbine governor to hold the electrical power output of the unit at its initial condition value. This value is stored in the parameter <i>Pmwset</i> (which equals <i>Pe</i>, initial generated power) when the model is initialized, and can be changed thereafter. The load controller shall be adjusted to respond gently relative to the speed governor.</li> <li>The parameters <i>Aset</i>, <i>Ka</i>, and <i>Ta</i> describe an acceleration limiter. <i>Ta</i> shall be non-zero, but the acceleration limiter can be disabled by setting <i>Aset </i>to a large value, such as 1.</li> <li>The parameters <i>Tsa</i> and <i>Tsb</i> are provided to augment the exhaust gas temperature measurement subsystem in gas turbines. For example, they can be set to values such as 4,0 and 5,0, to represent the ‘radiation shield’ element of large gas turbines.</li> <li>The parameters <i>Rup</i> and <i>Rdown</i> specify the maximum rate of increase and decrease of the output of the load limit controller (<i>Kpload</i> /<i> Kiload</i>). These parameters should normally be set, or defaulted to 99 / -99, but can be given particular values to represent the temperature limit controls of some General Electric<sup>TM</sup> heavy-duty engine controls. [Footnote: GE heavy-duty engine controls are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.]</li> <li>The fuel flow command <i>fsr </i>is determined by whichever is lowest of <i>fsrt</i>, <i>fsra</i>, and <i>fsrn</i>. Although not explicitly shown in the GovCT1 diagram, the signals that are not in control track <i>fsr</i> so that they do not “windup” beyond that value. This represents GE gas turbine control practice but might not be true for other controller designs.</li> <li>As shown in the GovCT1 diagram, when <i>Kpgov</i> is non-zero, the governor PI control is implemented to “track” <i>fsr</i> to prevent windup when <i>fsr</i> is limited by another signal (<i>fsrt</i>, <i>fsra</i>) or <i>Vmax</i>/<i>Vmi</i>n. If <i>Kpgov</i> is zero, the integral path is implemented directly. The same applies to the load limiter PI control with regard to <i>Kpload</i>.</li> <li>TheIn cases parameterwhere <i>delta tDm</i> inequals the0 block diagram is the simulation<i>Dm</i> timeloop step. It is not exchanged with the datasetactive. In cases where applications are using variable time step the results of the simulations could be different. In such situations the application applies a default value which is 0,001.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-08 09:14:252022-03-18 21:55:30
Diagram 'GovCT1' has no other changes. The shows its notes and every changed property.
▶▦GovCT2i
Diagram notes (destination, redlined)
This diagram describes the GovCT2 turbine governor model. Parameter Details: <ol> <li>The frequency-dependent limit reduces the <i>Vmax</i> limit on fuel flow signal (<i>fsr</i>). For normal operation, the limiter performs no action. When frequency (generator speed) drops below <i>Flim1</i>, the highest frequency data point, the desired value for the power limit (<i>Plim</i>) is determined by linear interpolation between associated data pairs. The maximum value of the limiter (<i>Vmax</i>) will ramp to the <i>fsr</i> value corresponding to <i>Plim</i> (<i>Plim </i>/ <i>Kturb</i> + <i>Wfnl</i>) at the <i>Prate</i> ramp rate. <i>Plim</i> will be updated as the frequency changes. If the frequency subsequently rises back above <u>Flim1</u>, the value of the limit will ramp up at the rate <i>Prate</i> back to the normal value of <i>Vmax</i>.</li> <li>The frequency-dependent limit is defined by a set of up to 10 pairs of points relating frequency (generator speed in Hz) and power. The points shall be monotonically decreasing in both the magnitude of frequency and power. If fewer than 10 points are needed to define the relationship, values of zero shall be entered for the remaining frequencies and power limits. The value of the last non-zero data pair is used as a lower limit, that is, the last two values are not extrapolated to calculate lower power limits. If there is only one set of frequency and power limits, those values will be used as a single limit of power applied at that frequency and below.</li> <li>Refer to the GovCT1 model for other parameter details. Aside from the frequency-dependent limit, GovCT2 is identical to GovCT1, except that the temperature fuel command <i>fsrt</i> does not track <i>fsr</i> when it is not in control. Instead, it stays at its upper limit (1.).</li> <li>The <i>Kpgov</i>/<i>Kigov</i> and <i>Kpload</i>/<i>Kiload</i> controllers include tracking logic to ensure smooth transfer between active controllers. This logic is not shown on the GovCT2 diagram.</li> <li><i>Pmwset</i> equals <i>Pe</i>, initial generated power.</li> <li>TheIn cases parameterwhere <i>delta tDm</i> inequals the0 block diagram is the simulation<i>Dm</i> timeloop step. It is not exchanged with the datasetactive. In cases where applications are using variable time step the results of the simulations could be different. In such situations the application applies a default value which is 0,001.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 22:05:312022-03-18 21:55:20
CHANGED{FB40153B-5AA6-4459-A5EC-D6045D5B11F0}
Diagram notes (destination, redlined)
This diagram describes the GovCT2 turbine governor model. Parameter Details: <ol> <li>The frequency-dependent limit reduces the <i>Vmax</i> limit on fuel flow signal (<i>fsr</i>). For normal operation, the limiter performs no action. When frequency (generator speed) drops below <i>Flim1</i>, the highest frequency data point, the desired value for the power limit (<i>Plim</i>) is determined by linear interpolation between associated data pairs. The maximum value of the limiter (<i>Vmax</i>) will ramp to the <i>fsr</i> value corresponding to <i>Plim</i> (<i>Plim </i>/ <i>Kturb</i> + <i>Wfnl</i>) at the <i>Prate</i> ramp rate. <i>Plim</i> will be updated as the frequency changes. If the frequency subsequently rises back above <u>Flim1</u>, the value of the limit will ramp up at the rate <i>Prate</i> back to the normal value of <i>Vmax</i>.</li> <li>The frequency-dependent limit is defined by a set of up to 10 pairs of points relating frequency (generator speed in Hz) and power. The points shall be monotonically decreasing in both the magnitude of frequency and power. If fewer than 10 points are needed to define the relationship, values of zero shall be entered for the remaining frequencies and power limits. The value of the last non-zero data pair is used as a lower limit, that is, the last two values are not extrapolated to calculate lower power limits. If there is only one set of frequency and power limits, those values will be used as a single limit of power applied at that frequency and below.</li> <li>Refer to the GovCT1 model for other parameter details. Aside from the frequency-dependent limit, GovCT2 is identical to GovCT1, except that the temperature fuel command <i>fsrt</i> does not track <i>fsr</i> when it is not in control. Instead, it stays at its upper limit (1.).</li> <li>The <i>Kpgov</i>/<i>Kigov</i> and <i>Kpload</i>/<i>Kiload</i> controllers include tracking logic to ensure smooth transfer between active controllers. This logic is not shown on the GovCT2 diagram.</li> <li><i>Pmwset</i> equals <i>Pe</i>, initial generated power.</li> <li>TheIn cases parameterwhere <i>delta tDm</i> inequals the0 block diagram is the simulation<i>Dm</i> timeloop step. It is not exchanged with the datasetactive. In cases where applications are using variable time step the results of the simulations could be different. In such situations the application applies a default value which is 0,001.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 22:05:312022-03-18 21:55:20
Diagram 'GovCT2' has no other changes. The shows its notes and every changed property.
▶▦GovGASTi
Diagram notes
This diagram describes the GovGAST turbine governor model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:48:212022-03-18 21:55:11
CHANGED{4F2A3413-B0E7-411e-82B8-FF63DD1F438F}
Diagram notes
This diagram describes the GovGAST turbine governor model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:48:212022-03-18 21:55:11
Diagram 'GovGAST' has no other changes. The shows its notes and every changed property.
▶▦GovGAST1i
Diagram notes (destination, redlined)
This diagram describes the GovGAST1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><i>Rmax</i>, <i>Linc</i>, <i>Tltr</i>, <i>Ltrate</i> represent a loading rate limit subsystem. For small excursions about a steady load, the fuel valve can open at a rate of <i>Rmax</i> PU / s. The time constant, <i>Tltr</i>, is used to obtain a long term average valve position. When a large output increase is called for, the fuel valve is allowed to open at the full rate only until the valve opening has moved ahead of the long term average position by <i>Linc</i> PU. After this the valve is permitted to open only at the rate, <i>Ltrat</i>, until the long term average position catches up.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However,If ifall <i>Vmax</i>values >are 1,0,set theto inputzero andthe outputnonlinear aregain scaledis by bypassed.<i>Vmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero values, the defaultrelationship curveshown (betweenin 0,0the ,GovSteamInputSpeedDeadband 0,0diagram andof 1,0the ,GovSteam1 1,0) will be usedmodel.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:50:252022-03-18 21:55:04
CHANGED{D22326D8-1ADA-4300-8A3C-91C66C862355}
Diagram notes (destination, redlined)
This diagram describes the GovGAST1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><i>Rmax</i>, <i>Linc</i>, <i>Tltr</i>, <i>Ltrate</i> represent a loading rate limit subsystem. For small excursions about a steady load, the fuel valve can open at a rate of <i>Rmax</i> PU / s. The time constant, <i>Tltr</i>, is used to obtain a long term average valve position. When a large output increase is called for, the fuel valve is allowed to open at the full rate only until the valve opening has moved ahead of the long term average position by <i>Linc</i> PU. After this the valve is permitted to open only at the rate, <i>Ltrat</i>, until the long term average position catches up.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However,If ifall <i>Vmax</i>values >are 1,0,set theto inputzero andthe outputnonlinear aregain scaledis by bypassed.<i>Vmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero values, the defaultrelationship curveshown (betweenin 0,0the ,GovSteamInputSpeedDeadband 0,0diagram andof 1,0the ,GovSteam1 1,0) will be usedmodel.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:50:252022-03-18 21:55:04
Diagram 'GovGAST1' has no other changes. The shows its notes and every changed property.
▶▦GovGAST2i
Diagram notes
This diagram describes the GovGAST2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Temperature control output is set to output of speed governor when temperature control input changes from positive to negative.</li> <li><i>F1</i> = <i>Tr</i> – <i>Af1</i>(1 – <i>Wf1</i>) – <i>Bf1</i>(<i>delta omega</i>).</li> <li><i>F2</i> = <i>Af2</i> + <i>Bf2</i>(<i>Wf2</i>) – <i>Cf2</i>(<i>delta omega</i>).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-28 07:54:462022-03-18 21:54:58
CHANGED{B1514175-70F2-4fc7-BA57-612449DCD3C5}
Diagram notes
This diagram describes the GovGAST2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Temperature control output is set to output of speed governor when temperature control input changes from positive to negative.</li> <li><i>F1</i> = <i>Tr</i> – <i>Af1</i>(1 – <i>Wf1</i>) – <i>Bf1</i>(<i>delta omega</i>).</li> <li><i>F2</i> = <i>Af2</i> + <i>Bf2</i>(<i>Wf2</i>) – <i>Cf2</i>(<i>delta omega</i>).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-28 07:54:462022-03-18 21:54:58
Diagram 'GovGAST2' has no other changes. The shows its notes and every changed property.
▶▦GovGAST3i
Diagram notes
This diagram describes the GovGAST3 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li><i>omega</i> has units of PU speed.</li> <li>Function for exhaust temperature calculation shown in GovGAST3ExhaustTemperature diagram.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:49:342022-03-18 21:54:49
CHANGED{8C75BDAD-AEC3-4b9b-9A86-2311B4A46669}
Diagram notes
This diagram describes the GovGAST3 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li><i>omega</i> has units of PU speed.</li> <li>Function for exhaust temperature calculation shown in GovGAST3ExhaustTemperature diagram.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:49:342022-03-18 21:54:49
Diagram 'GovGAST3' has no other changes. The shows its notes and every changed property.
▶▦GovGAST3ExhaustTemperaturei
Diagram notes
This diagram illustrates the function for exhaust temperature calculation.
Diagram metadata — changes
BaselineDestination
ModifiedDate2014-12-14 11:59:012022-03-18 21:54:40
CHANGED{48956452-E1DC-46ae-8A8F-2020A98BB3CE}
Diagram notes
This diagram illustrates the function for exhaust temperature calculation.
▤Metadata
BaselineDestination
ModifiedDate2014-12-14 11:59:012022-03-18 21:54:40
Diagram 'GovGAST3ExhaustTemperature' has no other changes. The shows its notes and every changed property.
▶▦GovGAST4i
Diagram notes
This diagram describes the GovGAST4 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li><i>omega</i> has units of PU speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:49:592022-03-18 21:54:30
CHANGED{7FA6AA3D-A148-4337-B527-11C22D37ECDA}
Diagram notes
This diagram describes the GovGAST4 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li><i>omega</i> has units of PU speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:49:592022-03-18 21:54:30
Diagram 'GovGAST4' has no other changes. The shows its notes and every changed property.
▶▦GovGASTWDi
Diagram notes
This diagram describes the GovGASTWD turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Temperature control output is set to output of speed governor when temperature control input changes from positive to negative.</li> <li><i>F1</i> = <i>Tr</i> – <i>Af1</i>(1 – <i>Wf1</i>) – <i>Bf1</i>(<i>delta omega</i>)</li> <li><i>F2</i> = <i>Af2</i> + <i>Bf2</i>(<i>Wf2</i>) – <i>Cf2</i>(<i>delta omega</i>).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:50:252022-03-18 21:54:22
CHANGED{6187C537-3497-46d0-8180-70B0C0BE68C0}
Diagram notes
This diagram describes the GovGASTWD turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Temperature control output is set to output of speed governor when temperature control input changes from positive to negative.</li> <li><i>F1</i> = <i>Tr</i> – <i>Af1</i>(1 – <i>Wf1</i>) – <i>Bf1</i>(<i>delta omega</i>)</li> <li><i>F2</i> = <i>Af2</i> + <i>Bf2</i>(<i>Wf2</i>) – <i>Cf2</i>(<i>delta omega</i>).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:50:252022-03-18 21:54:22
Diagram 'GovGASTWD' has no other changes. The shows its notes and every changed property.
▶▦GovHydro1i
Diagram notes
This diagram describes the GovHydro1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>The gates travel over a range of 1,0 PU from fully closed to fully opened. The gate position is normally greater than zero at zero power and normally less than 1,0 when power is 1,0 PU. <i>Gmax </i>and <i>Gmin</i> are operating limits.</li> <li><i>Dturb</i> has units of delta P (PU of mwcap) /delta speed (PU).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 13:18:192022-03-18 21:54:12
CHANGED{C5F99F17-E2BA-4546-A91C-831C18F5DEA3}
Diagram notes
This diagram describes the GovHydro1 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>The gates travel over a range of 1,0 PU from fully closed to fully opened. The gate position is normally greater than zero at zero power and normally less than 1,0 when power is 1,0 PU. <i>Gmax </i>and <i>Gmin</i> are operating limits.</li> <li><i>Dturb</i> has units of delta P (PU of mwcap) /delta speed (PU).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 13:18:192022-03-18 21:54:12
Diagram 'GovHydro1' has no other changes. The shows its notes and every changed property.
▶▦GovHydro2i
Diagram notes (destination, redlined)
This diagram describes the GovHydro2 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>This turbine governor model is a reasonable approximation to the performance of simple hydro plants for small motions of the gates about a given load, but it represents the variation of water inertia effect with load only if the values of the turbine parameters are properly adjusted by the user as load is varied. For idealized turbine model, set <i>Kturb</i> = 1,0, <i>Aturb</i> = -1,0, <i>Bturb </i>= 0,5.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0.) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. However The (0,0 if, <i>Pmax</i>0,0) >and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For compatibility with older versions of this model: <i>Kturb</i> = a23, <i>Aturb</i> = a11 – a13 x a21/a23, <i>Bturb</i> = a11.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:50:462022-03-18 21:54:03
CHANGED{0B70A04D-3C50-4585-9748-A58624CB55BB}
Diagram notes (destination, redlined)
This diagram describes the GovHydro2 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>This turbine governor model is a reasonable approximation to the performance of simple hydro plants for small motions of the gates about a given load, but it represents the variation of water inertia effect with load only if the values of the turbine parameters are properly adjusted by the user as load is varied. For idealized turbine model, set <i>Kturb</i> = 1,0, <i>Aturb</i> = -1,0, <i>Bturb </i>= 0,5.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0.) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. However The (0,0 if, <i>Pmax</i>0,0) >and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For compatibility with older versions of this model: <i>Kturb</i> = a23, <i>Aturb</i> = a11 – a13 x a21/a23, <i>Bturb</i> = a11.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:50:462022-03-18 21:54:03
Diagram 'GovHydro2' has no other changes. The shows its notes and every changed property.
▶▦GovHydro3i
Diagram notes (destination, redlined)
This diagram describes the GovHydro3 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However, ifIf <i>Pmax</i>all >values 1,0,are theset inputto andzero outputthe arenonlinear scaledgain byis bypassed.<i>Pmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero, the defaultrelationship hydroshown curvein (betweenthe (0,0GovSteamInputSpeedDeadband ,diagram 0,0)of andthe (1,0GovSteam1 , 1,0)) will be usedmodel.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:51:042022-03-18 21:53:56
CHANGED{84C45516-C8EC-4caa-86F0-960725E32F18}
Diagram notes (destination, redlined)
This diagram describes the GovHydro3 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However, ifIf <i>Pmax</i>all >values 1,0,are theset inputto andzero outputthe arenonlinear scaledgain byis bypassed.<i>Pmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero, the defaultrelationship hydroshown curvein (betweenthe (0,0GovSteamInputSpeedDeadband ,diagram 0,0)of andthe (1,0GovSteam1 , 1,0)) will be usedmodel.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:51:042022-03-18 21:53:56
Diagram 'GovHydro3' has no other changes. The shows its notes and every changed property.
▶▦GovHydro4i
Diagram notes
This diagram describes the GovHydro4 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The GovHydro4 model can be used to represent three different standard model variants: simple, Francis/Pelton and Kaplan.</li> <li>The gates travel over a range of 1 to 0 PU from fully closed to fully opened. The gates are at a position greater than zero at zero power and, normally, less than 1 PU when power is 1 PU. <i>Gmax </i>and <i>Gmin</i> are operating limits.</li> <li>The following parameter combinations are used by the variants to represent gate-head-flow power characteristics:</li> </ol> - Simple: the line with slope A<i>t</i> and intercept <i>Qnl</i> describes the gate opening-to-turbine power characteristic (as shown in the GovHydro4SimpleHydroTurbine diagram). This curve is proportional to turbine power, with the constant of proportionality being a function of available head. This constant is specified by the turbine gain, <i>At</i>. Parameters <i>Gv0</i> to <i>Gv5</i>, <i>Pgv0</i> to <i>Pgv5, and Bgv0</i> to <i>Bgv5</i> are not considered. - Francis/Pelton turbine model: (<i>Gv0</i>, <i>Pgv0</i>) thru (<i>Gv5</i>, <i>Pgv5</i>) are used to describe the non-linear gate opening-to-turbine power characteristic (as shown in the GovHydro4FrancisPeltonTurbine diagram). <i>Bgv0</i> to <i>Bgv5</i> are not considered. - Kaplan turbine model: (<i>Gv0</i>, <i>Pgv0</i>) thru (<i>Gv5</i>, <i>Pgv5</i>) and (<i>Gv0</i>, <i>Bv0</i>) thru (<i>Gv5</i>, <i>Bgv5</i>) are used to describe the non-linear characteristics of gate opening-to-turbine power and gate opening-to-blade angle (as shown in the GovHydro4KaplanTurbine diagram).<font color="#7030a0"> </font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-13 10:09:542022-03-18 21:53:45
CHANGED{1F0F6C06-17AA-478a-A4CC-81739074A9F3}
Diagram notes
This diagram describes the GovHydro4 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The GovHydro4 model can be used to represent three different standard model variants: simple, Francis/Pelton and Kaplan.</li> <li>The gates travel over a range of 1 to 0 PU from fully closed to fully opened. The gates are at a position greater than zero at zero power and, normally, less than 1 PU when power is 1 PU. <i>Gmax </i>and <i>Gmin</i> are operating limits.</li> <li>The following parameter combinations are used by the variants to represent gate-head-flow power characteristics:</li> </ol> - Simple: the line with slope A<i>t</i> and intercept <i>Qnl</i> describes the gate opening-to-turbine power characteristic (as shown in the GovHydro4SimpleHydroTurbine diagram). This curve is proportional to turbine power, with the constant of proportionality being a function of available head. This constant is specified by the turbine gain, <i>At</i>. Parameters <i>Gv0</i> to <i>Gv5</i>, <i>Pgv0</i> to <i>Pgv5, and Bgv0</i> to <i>Bgv5</i> are not considered. - Francis/Pelton turbine model: (<i>Gv0</i>, <i>Pgv0</i>) thru (<i>Gv5</i>, <i>Pgv5</i>) are used to describe the non-linear gate opening-to-turbine power characteristic (as shown in the GovHydro4FrancisPeltonTurbine diagram). <i>Bgv0</i> to <i>Bgv5</i> are not considered. - Kaplan turbine model: (<i>Gv0</i>, <i>Pgv0</i>) thru (<i>Gv5</i>, <i>Pgv5</i>) and (<i>Gv0</i>, <i>Bv0</i>) thru (<i>Gv5</i>, <i>Bgv5</i>) are used to describe the non-linear characteristics of gate opening-to-turbine power and gate opening-to-blade angle (as shown in the GovHydro4KaplanTurbine diagram).<font color="#7030a0"> </font>
▤Metadata
BaselineDestination
ModifiedDate2017-10-13 10:09:542022-03-18 21:53:45
Diagram 'GovHydro4' has no other changes. The shows its notes and every changed property.
▶▦GovHydro4FrancisPeltonTurbinei
Diagram notes
This diagram illustrates the gate-head-flow-power characteristics for a Francis/Pelton turbine model. Parameter details: <ol> <li>The curve described by (<i>Gv0</i>, <i>Pgv0</i>) to (<i>Gv5</i>, <i>Pgv5</i>) describes the relationship of flow through the turbine to stroke of the gate actuating servomotor. </li> <li>If <i>Gv0</i> is greater than 0, the first two data points will be used to extrapolate downward for gate positions less than <i>Gv0</i> If <i>Gv0</i> is a negative number or zero, the default hydro curve (between (0,0 , 0,0) and (1,0 , 1,0)) will be used.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-10 20:47:572022-03-18 21:53:30
CHANGED{C2A10131-4098-400e-A72B-1A417E4A6E61}
Diagram notes
This diagram illustrates the gate-head-flow-power characteristics for a Francis/Pelton turbine model. Parameter details: <ol> <li>The curve described by (<i>Gv0</i>, <i>Pgv0</i>) to (<i>Gv5</i>, <i>Pgv5</i>) describes the relationship of flow through the turbine to stroke of the gate actuating servomotor. </li> <li>If <i>Gv0</i> is greater than 0, the first two data points will be used to extrapolate downward for gate positions less than <i>Gv0</i> If <i>Gv0</i> is a negative number or zero, the default hydro curve (between (0,0 , 0,0) and (1,0 , 1,0)) will be used.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-10 20:47:572022-03-18 21:53:30
Diagram 'GovHydro4FrancisPeltonTurbine' has no other changes. The shows its notes and every changed property.
▶▦GovHydro4KaplanTurbinei
Diagram notes
This diagram illustrates the non-linear characteristics of gate opening-to-turbine power and gate opening-to-blade angle for a Kaplan turbine model. Parameter details: <ol> <li>The curve described by (<i>Gv0</i>, <i>Pgv0</i>) to (<i>Gv5</i>, <i>Pgv5</i>) describes the relationship of flow through the turbine to stroke of the gate actuating servomotor. </li> <li>If <i>Gv0</i> is greater than 0, the first two data points will be used to extrapolate downward for gate positions less than <i>Gv0</i> If <i>Gv0</i> is a negative number or zero, the default hydro curve (between (0,0 , 0,0) and (1,0 , 1,0)) will be used.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-10 20:56:412022-03-18 21:53:21
CHANGED{BFECFB7B-066D-4fe9-92E7-ABE51E38344C}
Diagram notes
This diagram illustrates the non-linear characteristics of gate opening-to-turbine power and gate opening-to-blade angle for a Kaplan turbine model. Parameter details: <ol> <li>The curve described by (<i>Gv0</i>, <i>Pgv0</i>) to (<i>Gv5</i>, <i>Pgv5</i>) describes the relationship of flow through the turbine to stroke of the gate actuating servomotor. </li> <li>If <i>Gv0</i> is greater than 0, the first two data points will be used to extrapolate downward for gate positions less than <i>Gv0</i> If <i>Gv0</i> is a negative number or zero, the default hydro curve (between (0,0 , 0,0) and (1,0 , 1,0)) will be used.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-10 20:56:412022-03-18 21:53:21
Diagram 'GovHydro4KaplanTurbine' has no other changes. The shows its notes and every changed property.
▶▦GovHydro4SimpleHydroTurbinei
Diagram notes
This diagram illustrates the gate-head-flow-power characteristics for a simple general purpose model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-10 07:53:492022-03-18 21:53:38
CHANGED{EE5764AC-E7EF-48b5-8F4C-8915A794889F}
Diagram notes
This diagram illustrates the gate-head-flow-power characteristics for a simple general purpose model.
▤Metadata
BaselineDestination
ModifiedDate2017-10-10 07:53:492022-03-18 21:53:38
Diagram 'GovHydro4SimpleHydroTurbine' has no other changes. The shows its notes and every changed property.
▶▦GovHydroDDi
Diagram notes (destination, redlined)
This diagram describes the GovHydroDD turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Tf </i>is input as zero, but<i> K1</i> or <i>K2</i> is not zero, <i>Tf</i> is set to a small value (4 times integration time step). If <i>Bturb</i> x <i>Tturb</i> is less than 4 times integration time step, <i>Tturb</i> is set to zero to bypass the block.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax</i>0,0) >and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero values,(only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For a hydro turbine, set <i>Tturb</i> = <i>Tw</i> (water starting time), set <i>Aturb</i> = -1,0 and <i>Bturb</i> = 0,5. For a diesel engine or two-shaft gas turbine, set <i>Aturb</i> = 0,8 and <i>Bturb</i> = 1,0 and <i>Tturb</i> = 1 s. For a small steam turbine with a non-reheat steam supply or a single- shaft gas turbine, set <i>Aturb</i> = 0,0 and <i>Bturb</i> = 1,0 and <i>Tturb</i> = 0,2 s.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:51:242022-03-18 21:53:10
CHANGED{0AF7C99D-429B-4ff3-9C77-9BF1980BB22F}
Diagram notes (destination, redlined)
This diagram describes the GovHydroDD turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Tf </i>is input as zero, but<i> K1</i> or <i>K2</i> is not zero, <i>Tf</i> is set to a small value (4 times integration time step). If <i>Bturb</i> x <i>Tturb</i> is less than 4 times integration time step, <i>Tturb</i> is set to zero to bypass the block.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax</i>0,0) >and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero values,(only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For a hydro turbine, set <i>Tturb</i> = <i>Tw</i> (water starting time), set <i>Aturb</i> = -1,0 and <i>Bturb</i> = 0,5. For a diesel engine or two-shaft gas turbine, set <i>Aturb</i> = 0,8 and <i>Bturb</i> = 1,0 and <i>Tturb</i> = 1 s. For a small steam turbine with a non-reheat steam supply or a single- shaft gas turbine, set <i>Aturb</i> = 0,0 and <i>Bturb</i> = 1,0 and <i>Tturb</i> = 0,2 s.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:51:242022-03-18 21:53:10
Diagram 'GovHydroDD' has no other changes. The shows its notes and every changed property.
▶▦GovHydroFrancisi
Diagram notes
This diagram describes the GovHydroFrancis turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>Rated hydraulic head, <i>Hn</i> in metres, and rated flow, <i>Qn</i> in cubic metres per s, are the design parameters of the hydraulic system capability.</li> <li>Hydraulic system head attributes (<i>Zsfc</i>, <i>H1</i>, <i>H2</i>) are in metres but in the block diagram are in PU on base of <i>Hn</i> in metres.</li> <li>Hydraulic area attributes (<i>Av0</i>, A<i>v1</i>) are in square metres but in the block diagram are in PU on base of <i>Qn </i>/ <i>Hn</i> in square metres per s.</li> <li><i>omega</i> has units of PU speed.</li> <li>Non-linear gain and efficiency equations are shown in GovHydroFrancisNonLinearGainAndEfficiency diagram.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 14:51:302022-03-18 21:53:02
CHANGED{1055BAFE-ECFE-418f-97D6-0980C9FBCF16}
Diagram notes
This diagram describes the GovHydroFrancis turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>Rated hydraulic head, <i>Hn</i> in metres, and rated flow, <i>Qn</i> in cubic metres per s, are the design parameters of the hydraulic system capability.</li> <li>Hydraulic system head attributes (<i>Zsfc</i>, <i>H1</i>, <i>H2</i>) are in metres but in the block diagram are in PU on base of <i>Hn</i> in metres.</li> <li>Hydraulic area attributes (<i>Av0</i>, A<i>v1</i>) are in square metres but in the block diagram are in PU on base of <i>Qn </i>/ <i>Hn</i> in square metres per s.</li> <li><i>omega</i> has units of PU speed.</li> <li>Non-linear gain and efficiency equations are shown in GovHydroFrancisNonLinearGainAndEfficiency diagram.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 14:51:302022-03-18 21:53:02
Diagram 'GovHydroFrancis' has no other changes. The shows its notes and every changed property.
▶▦GovHydroFrancisNonLinearGainAndEfficiencyi
Diagram notes
This diagram illustrates the non-linear gain and efficiency equations.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:52:52
CHANGED{A46015A8-C955-442c-BFCC-8702588D795E}
Diagram notes
This diagram illustrates the non-linear gain and efficiency equations.
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:52:52
Diagram 'GovHydroFrancisNonLinearGainAndEfficiency' has no other changes. The shows its notes and every changed property.
▶▦GovHydroIEEE0i
Diagram notes
This diagram describes the CIM model interpretation of the IEEE simplified hydro governor-turbine model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:11:232022-03-18 21:55:56
CHANGED{E09FBF11-424F-42a7-BC8B-68E09C460BF8}
Diagram notes
This diagram describes the CIM model interpretation of the IEEE simplified hydro governor-turbine model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:11:232022-03-18 21:55:56
Diagram 'GovHydroIEEE0' has no other changes. The shows its notes and every changed property.
▶▦GovHydroIEEE2i
Diagram notes (destination, redlined)
This diagram describes the CIM model interpretation of the IEEE hydro turbine governor model representing plants with straightforward penstock configurations and hydraulic-dashpot governors. Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>This turbine governor model is a reasonable approximation to the performance of simple hydro plants for small motions of the gates about a given load, but it represents the variation of water inertia effect with load only if the values of the turbine parameters are properly adjusted by the user as load is varied. For idealized turbine model, set <i>Kturb</i> = 1, <i>Aturb</i> = -1, <i>Bturb</i> = 0,5.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The output is not allowed to go beyond 0,0 and 1,0. However, if <i>Pmax</i> > 1,0, the input and output are scaled by <i>Pmax</i>. If <i>Gv1</i> is a negative number or zero values, the default hydro curve (between 0,0 , 0,0 and 1,0 , 1,0) will be used.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:47:482022-03-18 21:55:47
CHANGED{B91F40D1-1ADB-46b4-909C-D1C3DA82C9EB}
Diagram notes (destination, redlined)
This diagram describes the CIM model interpretation of the IEEE hydro turbine governor model representing plants with straightforward penstock configurations and hydraulic-dashpot governors. Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>This turbine governor model is a reasonable approximation to the performance of simple hydro plants for small motions of the gates about a given load, but it represents the variation of water inertia effect with load only if the values of the turbine parameters are properly adjusted by the user as load is varied. For idealized turbine model, set <i>Kturb</i> = 1, <i>Aturb</i> = -1, <i>Bturb</i> = 0,5.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The output is not allowed to go beyond 0,0 and 1,0. However, if <i>Pmax</i> > 1,0, the input and output are scaled by <i>Pmax</i>. If <i>Gv1</i> is a negative number or zero values, the default hydro curve (between 0,0 , 0,0 and 1,0 , 1,0) will be used.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:47:482022-03-18 21:55:47
Diagram 'GovHydroIEEE2' has no other changes. The shows its notes and every changed property.
▶▦GovHydroPeltoni
Diagram notes
This diagram describes the GovHydroPelton turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>Rated hydraulic head, <i>Hn,</i> in metres, and rated flow, <i>Qn,</i> in cubic metres per s, are the design parameters of the hydraulic system capability.</li> <li>Hydraulic system head attributes (<i>Zsfc</i>, <i>H1</i>, <i><u>H2</u></i>) are in metres but in the block diagram are in PU on base of <i>Hn</i> in metres.</li> <li>Hydraulic area attributes (<i>Av0</i>, A<i>v1</i>) are in square metres but in the block diagram are in PU on base of <i>Qn </i>/ <i>Hn</i> in square metres per s.</li> <li><i>omega</i> has units of PU speed.</li> <li>Non-linear gains and efficiency shown in GovHydroPeltonNonLinearGainAndEfficiency diagram.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:53:212022-03-18 21:52:37
CHANGED{AA274458-60D6-4da2-A538-A6518CE877AE}
Diagram notes
This diagram describes the GovHydroPelton turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>Rated hydraulic head, <i>Hn,</i> in metres, and rated flow, <i>Qn,</i> in cubic metres per s, are the design parameters of the hydraulic system capability.</li> <li>Hydraulic system head attributes (<i>Zsfc</i>, <i>H1</i>, <i><u>H2</u></i>) are in metres but in the block diagram are in PU on base of <i>Hn</i> in metres.</li> <li>Hydraulic area attributes (<i>Av0</i>, A<i>v1</i>) are in square metres but in the block diagram are in PU on base of <i>Qn </i>/ <i>Hn</i> in square metres per s.</li> <li><i>omega</i> has units of PU speed.</li> <li>Non-linear gains and efficiency shown in GovHydroPeltonNonLinearGainAndEfficiency diagram.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:53:212022-03-18 21:52:37
Diagram 'GovHydroPelton' has no other changes. The shows its notes and every changed property.
▶▦GovHydroPeltonNonLinearGainAndEfficiencyi
Diagram notes
This diagram illustrates the non-linear gain and efficiency equations.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-17 15:43:262022-03-18 21:52:28
CHANGED{D8697E9E-00A7-4f6c-A843-21EBA6487805}
Diagram notes
This diagram illustrates the non-linear gain and efficiency equations.
▤Metadata
BaselineDestination
ModifiedDate2017-09-17 15:43:262022-03-18 21:52:28
Diagram 'GovHydroPeltonNonLinearGainAndEfficiency' has no other changes. The shows its notes and every changed property.
▶▦GovHydroPIDi
Diagram notes (destination, redlined)
This diagram describes the GovHydroPID turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>If <i>Tf</i> is zero, but <i>Kd</i> is not zero, <i>Tf</i> is set to a small value (4 times integration time step).</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax</i>0,0) >and (1,0 the, input1,0) andpoints output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For a hydro turbine, set <i>Tturb</i> = <i>Tw</i> (water starting time), set <i>Aturb</i> = -1 and <i>Bturb</i> = 0,5. For a diesel engine or two-shaft gas turbine, set <i>Aturb</i> = 0,8 and <i>Bturb</i> = 1 and <i>Tturb</i> = 1 s. For a small steam turbine with a non-reheat steam supply or a single- shaft gas turbine, set <i>Aturb</i> = 0 and <i>Bturb</i> = 1 and <i>Tturb</i> = 0 s.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:51:432022-03-18 21:52:20
CHANGED{3BA0197C-3EE5-42c8-A8E0-1310FB78B0AD}
Diagram notes (destination, redlined)
This diagram describes the GovHydroPID turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>If <i>Tf</i> is zero, but <i>Kd</i> is not zero, <i>Tf</i> is set to a small value (4 times integration time step).</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax</i>0,0) >and (1,0 the, input1,0) andpoints output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> <li>For a hydro turbine, set <i>Tturb</i> = <i>Tw</i> (water starting time), set <i>Aturb</i> = -1 and <i>Bturb</i> = 0,5. For a diesel engine or two-shaft gas turbine, set <i>Aturb</i> = 0,8 and <i>Bturb</i> = 1 and <i>Tturb</i> = 1 s. For a small steam turbine with a non-reheat steam supply or a single- shaft gas turbine, set <i>Aturb</i> = 0 and <i>Bturb</i> = 1 and <i>Tturb</i> = 0 s.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamInputSpeedDeadband diagram of the GovSteam1 model.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:51:432022-03-18 21:52:20
Diagram 'GovHydroPID' has no other changes. The shows its notes and every changed property.
▶▦GovHydroPID2i
Diagram notes (destination, redlined)
This diagram describes the GovHydroPID2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The gates travel over a range of 1,0 PU from fully closed to fully opened. The gates are at a position greater than zero at zero power and, normally, less than 1,0 when power is 1,0 PU.</li> <li><i>G0</i>, <i>P0</i>, G<i>1</i>, <i>P1</i>, <i>G2</i>, <i>P2</i>, <i>G3</i> and <i>P3</i> specify the variation of power with gate <i>G3 > G2</i> > <i>G1</i> > <i>G0</i>.</li> <li>This model uses a simplified turbine-penstock model that does not account for the variation of the water inertia effect with gate opening. To make this model correspond to other models using the "classical" turbine-penstock model, set <i>Atw</i> to unity. To approximate water inertia effects at part load, <i>Atw</i> can be set to the PU gate opening about which perturbations are centred.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:54:162022-03-18 21:52:13
CHANGED{A2EFD39D-D1BF-4662-BBB9-7F1F4CB6059C}
Diagram notes (destination, redlined)
This diagram describes the GovHydroPID2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The gates travel over a range of 1,0 PU from fully closed to fully opened. The gates are at a position greater than zero at zero power and, normally, less than 1,0 when power is 1,0 PU.</li> <li><i>G0</i>, <i>P0</i>, G<i>1</i>, <i>P1</i>, <i>G2</i>, <i>P2</i>, <i>G3</i> and <i>P3</i> specify the variation of power with gate <i>G3 > G2</i> > <i>G1</i> > <i>G0</i>.</li> <li>This model uses a simplified turbine-penstock model that does not account for the variation of the water inertia effect with gate opening. To make this model correspond to other models using the "classical" turbine-penstock model, set <i>Atw</i> to unity. To approximate water inertia effects at part load, <i>Atw</i> can be set to the PU gate opening about which perturbations are centred.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:54:162022-03-18 21:52:13
Diagram 'GovHydroPID2' has no other changes. The shows its notes and every changed property.
▶▦GovHydroRi
Diagram notes (destination, redlined)
This diagram describes the GovHydroR turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However,If ifall <i>Pmax</i>values >are 1,0,set theto inputzero andthe outputnonlinear aregain scaledis by bypassed.<i>Pmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero, the defaultrelationship hydroshown curvein (betweenthe (0,0GovSteamInputSpeedDeadband ,diagram 0,0)of andthe (1,0GovSteam1 , 1,0)) will be usedmodel.</font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:51:592022-03-18 21:52:05
CHANGED{480E8F16-7C83-4f77-9E03-C534E15D7E8F}
Diagram notes (destination, redlined)
This diagram describes the GovHydroR turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The output is not allowed to go beyond 0,0 and 1,0. The (0,0 , 0,0) and (1,0 , 1,0) points canare beexchanged assumedexplicitly. The outputcharacteristic shall have isonly notpositive allowedvalues toor gozero beyond(only 0,0for andone 1,0point). However,If ifall <i>Pmax</i>values >are 1,0,set theto inputzero andthe outputnonlinear aregain scaledis by bypassed.<i>Pmax</ili>. If <ili>Gv1</ifont color="#0f0f0f">The isintentional ainput negativespeed numberdeadband orfollows zero, the defaultrelationship hydroshown curvein (betweenthe (0,0GovSteamInputSpeedDeadband ,diagram 0,0)of andthe (1,0GovSteam1 , 1,0)) will be usedmodel.</font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:51:592022-03-18 21:52:05
Diagram 'GovHydroR' has no other changes. The shows its notes and every changed property.
▶▦GovHydroWEHi
Diagram notes
This diagram describes the GovHydroWEH turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear relationship between gate position and water flow can be input with up to 5 points specified by pairs of .gv<i>n</i> and .fl<i>n</i> attributes.</li> <li>The nonlinear relationship between turbine flow and mechanical power output (on machine MVA rating) can be input with up to 10 points specified by pairs of .fp<i>n</i> and .pmss<i>n</i> attributes.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:52:232022-03-18 21:51:56
CHANGED{FEEBD5DB-2368-4b71-A035-AB2AB13027B8}
Diagram notes
This diagram describes the GovHydroWEH turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The nonlinear relationship between gate position and water flow can be input with up to 5 points specified by pairs of .gv<i>n</i> and .fl<i>n</i> attributes.</li> <li>The nonlinear relationship between turbine flow and mechanical power output (on machine MVA rating) can be input with up to 10 points specified by pairs of .fp<i>n</i> and .pmss<i>n</i> attributes.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:52:232022-03-18 21:51:56
Diagram 'GovHydroWEH' has no other changes. The shows its notes and every changed property.
▶▦GovHydroWPIDi
Diagram notes (destination, redlined)
This diagram describes the GovHydroWPID turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The nonlinear gain between gate position and power can be input with up to 36 points. The (0,0output ,is 0,0)not pointallowed canto bego assumed.beyond In this model0,0 <i>Gv3and </i>= 1,0. andThe the(0,0 output, is0,0) notand allowed to go above (1,0. However, if <i>Pmax</i> > 1,0,) thepoints input and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:52:462022-03-18 21:51:46
CHANGED{8B463146-1121-4176-8F1B-C432721ED450}
Diagram notes (destination, redlined)
This diagram describes the GovHydroWPID turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The nonlinear gain between gate position and power can be input with up to 36 points. The (0,0output ,is 0,0)not pointallowed canto bego assumed.beyond In this model0,0 <i>Gv3and </i>= 1,0. andThe the(0,0 output, is0,0) notand allowed to go above (1,0. However, if <i>Pmax</i> > 1,0,) thepoints input and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only thefor defaultone hydropoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:52:462022-03-18 21:51:46
Diagram 'GovHydroWPID' has no other changes. The shows its notes and every changed property.
▶▦GovSteam0i
Diagram notes
This diagram describes the GovSteam0 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>To represent a non-reheat turbine set <i>T2</i>= 0 and <i>T3</i> to about 0,5 s. For reheat turbine, set <i>T2</i> = <i>T3</i> x (HP turbine fraction).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:51:35
CHANGED{D01C30E7-19FC-4b50-803E-CA3F958B456E}
Diagram notes
This diagram describes the GovSteam0 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>To represent a non-reheat turbine set <i>T2</i>= 0 and <i>T3</i> to about 0,5 s. For reheat turbine, set <i>T2</i> = <i>T3</i> x (HP turbine fraction).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-01 15:39:532022-03-18 21:51:35
Diagram 'GovSteam0' has no other changes. The shows its notes and every changed property.
▶▦GovSteam1i
Diagram notes (destination, redlined)
This diagram describes the GovSteam1 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>For a tandem-compound turbine, the parameters <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8</i> are ignored. For a cross-compound turbine, two generators are connected to this turbine-governor model.</li> <li>Each generator shall be represented in the load flow by data on its own MVA base. The values of <i>K1</i>, <i>K3</i>, <i>K5</i>, and <i>K7</i> shall be specified to describe the proportionate development of power on the first turbine shaft. <i>K2</i>, <i>K4</i>, K<i>6</i>, and <i>K8</i> shall describe the second turbine shaft. Normally <i>K1</i> + <i>K3</i> + <i>K5</i> + <i>K7</i> = 1,0 and <i>K2</i> + <i>K4</i> + <i>K6</i> + <i>K8</i> = 1,0 (if second generator is present).</li> <li>The division of power between the two shafts is in proportion to the MW values of MVA bases of the two generators. The initial condition load flow should, therefore, have the two generators loaded to the same fraction of each one’s MVAMW base.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamIEEE1InputSpeedDeadbandGovSteamInputSpeedDeadband diagram.</font></li> <li><font color="#0f0f0f">The unintentional deadband can be used to represent backlash hysteresis in the control components by the relationship shown in the GovSteamIEEE1BacklashHysteresisGovSteamBacklashHysteresis diagram.</font></li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax0,0) </i>>and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only for theone defaultpoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:53:082022-03-18 21:51:27
CHANGED{A656F5D9-0CB1-4057-B328-4273A3BDB129}
Diagram notes (destination, redlined)
This diagram describes the GovSteam1 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>For a tandem-compound turbine, the parameters <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8</i> are ignored. For a cross-compound turbine, two generators are connected to this turbine-governor model.</li> <li>Each generator shall be represented in the load flow by data on its own MVA base. The values of <i>K1</i>, <i>K3</i>, <i>K5</i>, and <i>K7</i> shall be specified to describe the proportionate development of power on the first turbine shaft. <i>K2</i>, <i>K4</i>, K<i>6</i>, and <i>K8</i> shall describe the second turbine shaft. Normally <i>K1</i> + <i>K3</i> + <i>K5</i> + <i>K7</i> = 1,0 and <i>K2</i> + <i>K4</i> + <i>K6</i> + <i>K8</i> = 1,0 (if second generator is present).</li> <li>The division of power between the two shafts is in proportion to the MW values of MVA bases of the two generators. The initial condition load flow should, therefore, have the two generators loaded to the same fraction of each one’s MVAMW base.</li> <li><font color="#0f0f0f">The intentional input speed deadband follows the relationship shown in the GovSteamIEEE1InputSpeedDeadbandGovSteamInputSpeedDeadband diagram.</font></li> <li><font color="#0f0f0f">The unintentional deadband can be used to represent backlash hysteresis in the control components by the relationship shown in the GovSteamIEEE1BacklashHysteresisGovSteamBacklashHysteresis diagram.</font></li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. HoweverThe (0,0 if, <i>Pmax0,0) </i>>and (1,0 , the1,0) inputpoints and output are scaledexchanged byexplicitly. <i>Pmax</i>.The Ifcharacteristic <i>Gv1</i>shall ishave aonly negativepositive numbervalues or zero, (only for theone defaultpoint). curveIf (betweenall (0,0values ,are 0,0)set andto (1,0zero ,the 1,0))nonlinear willgain beis usedbypassed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:53:082022-03-18 21:51:27
Diagram 'GovSteam1' has no other changes. The shows its notes and every changed property.
▶▦GovSteam1BacklashHysteresisi
Diagram notes
This diagram illustrates the backlash hysteresis.
Diagram metadata — changes
BaselineDestination
ModifiedDate2014-12-14 17:44:482022-03-18 21:51:19
CHANGED{38A99959-2C6B-4390-9783-FAD1EEC79C14}
Diagram notes
This diagram illustrates the backlash hysteresis.
▤Metadata
BaselineDestination
ModifiedDate2014-12-14 17:44:482022-03-18 21:51:19
Diagram 'GovSteam1BacklashHysteresis' has no other changes. The shows its notes and every changed property.
▶▦GovSteam1InputSpeedDeadbandi
Diagram notes (destination, redlined)
This diagram illustrates the input speed deadband. This diagram illustrates the input speed deadband. <font color="#0f0f0f">This intentional input speed deadband follows the definition specified in IEEE Technical report PES-TR1, 2013, Appendix B.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2014-12-14 17:45:402022-03-18 21:51:06
CHANGED{8B4C1367-8F28-44c3-BE9C-D265E377FB3B}
Diagram notes (destination, redlined)
This diagram illustrates the input speed deadband. This diagram illustrates the input speed deadband. <font color="#0f0f0f">This intentional input speed deadband follows the definition specified in IEEE Technical report PES-TR1, 2013, Appendix B.</font>
▤Metadata
BaselineDestination
ModifiedDate2014-12-14 17:45:402022-03-18 21:51:06
Diagram 'GovSteam1InputSpeedDeadband' has no other changes. The shows its notes and every changed property.
▶▦GovSteam2i
Diagram notes
This diagram describes the GovSteam2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>This model can be used for both thermal and hydro power plants.</li> <li><i>omega</i> has units of per unit speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:56:112022-03-18 21:50:56
CHANGED{B572F224-2EC2-44a9-9BE6-AF3DF55801FF}
Diagram notes
This diagram describes the GovSteam2 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>This model can be used for both thermal and hydro power plants.</li> <li><i>omega</i> has units of per unit speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:56:112022-03-18 21:50:56
Diagram 'GovSteam2' has no other changes. The shows its notes and every changed property.
▶▦GovSteamBBi
Diagram notes
This diagram describes the GovSteamBB turbine governor model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 19:56:242022-03-18 21:50:46
CHANGED{41CD4E91-0C11-41aa-ACF8-492A99061486}
Diagram notes
This diagram describes the GovSteamBB turbine governor model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 19:56:242022-03-18 21:50:46
Diagram 'GovSteamBB' has no other changes. The shows its notes and every changed property.
▶▦GovSteamCCi
Diagram notes (destination, redlined)
This diagram describes the GovSteamCC turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Both generators shall be present and in service.</li> <li>Each generator shall be represented in the load flow by data stated on its own MVA base. The division of power between the two turbines is determined by the values of <i>MWbase</i> of the two generators, not by the values of <i>Fhp</i> and <i>Flp</i>.</li> <li>The rotor speed reference values (<i>omegaref</i>) are the respective reference values of the units, each of which has its own separate shaft with each its own generator and exciter.</li> <li><i>V</i> is the terminal voltage.</li> <li><i>Fhp</i> and <i>Flp</i> can be used to represent the presence of dual reheat stages for a single turbine. If there is only one reheat stage, between the HP and LP turbines, <i>Fhp</i> and <i>Flp</i> should normally be unity and zero, respectively, and <i>T5lp</i> should be set to the reheater time constant.</li> <li><i>Dhp</i> and <i>Dlp</i> give a rough approximation of the damping of intermachine speed oscillations by electromagnetic effects. When the generators are represented by the round rotor model with proper values for subtransient time constants, this damping is represented accurately in the generator electrical torques and <i>Dhp</i> and <i>Dlp</i> should be set to zero.</li> <li>If any of the time constants are zero, they are bypassed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:53:302022-03-18 21:50:36
CHANGED{B041B35D-9147-4488-8E9C-C3E996210B4B}
Diagram notes (destination, redlined)
This diagram describes the GovSteamCC turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>Both generators shall be present and in service.</li> <li>Each generator shall be represented in the load flow by data stated on its own MVA base. The division of power between the two turbines is determined by the values of <i>MWbase</i> of the two generators, not by the values of <i>Fhp</i> and <i>Flp</i>.</li> <li>The rotor speed reference values (<i>omegaref</i>) are the respective reference values of the units, each of which has its own separate shaft with each its own generator and exciter.</li> <li><i>V</i> is the terminal voltage.</li> <li><i>Fhp</i> and <i>Flp</i> can be used to represent the presence of dual reheat stages for a single turbine. If there is only one reheat stage, between the HP and LP turbines, <i>Fhp</i> and <i>Flp</i> should normally be unity and zero, respectively, and <i>T5lp</i> should be set to the reheater time constant.</li> <li><i>Dhp</i> and <i>Dlp</i> give a rough approximation of the damping of intermachine speed oscillations by electromagnetic effects. When the generators are represented by the round rotor model with proper values for subtransient time constants, this damping is represented accurately in the generator electrical torques and <i>Dhp</i> and <i>Dlp</i> should be set to zero.</li> <li>If any of the time constants are zero, they are bypassed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:53:302022-03-18 21:50:36
Diagram 'GovSteamCC' has no other changes. The shows its notes and every changed property.
▶▦GovSteamEUi
Diagram notes (destination, redlined)
This diagram describes the GovSteamEU turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of turbine MW capability <i>MWbase</i>.</li> <li>To represent a non-reheat turbine, set <i>Trh</i> = 0 and <i>Tlp</i> to about 0,5 s.</li> <li><i>F(v)</i> is minimum value selection.</li> <li>Frequency (<i>f</i>) is local (nodal) frequency.</li> <li>The model enables different values for Pe and Pm (Pm = Pe+delta P this power balance is ensured by the swing equation). But the problem is in per unit system. If Pe and Pm are per units on generator MVA base, than the input to the power transducer should be multiplied by the correction factor KN= generator MVA base /turbine mwbase and on the contrary, output should be divided by the same factor.</li> <li>The typical values are assuming parallel operation. However, the model can also be used with a set of parameters that enables island operation. The model contains the superimposed power control (because it is a normal operating regime), but it enables proportional speed control as well - Pe=(Pref-deltaf x kfcor), supposed that in the steady state delta f is close to delta omega for abs(delta f)>db1.</li> <li>The model works only under the assumption of zero resistive and mechanical losses, when in the steady state equality applies: Pe = Pm. This is based on the assumption that in the vast majority of calculations, these losses are not considered anyway, as they do not have a major effect on dynamic stability.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:38:162022-03-18 21:50:27
CHANGED{628C3E15-4D1E-4288-89BA-09553D5B6768}
Diagram notes (destination, redlined)
This diagram describes the GovSteamEU turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of turbine MW capability <i>MWbase</i>.</li> <li>To represent a non-reheat turbine, set <i>Trh</i> = 0 and <i>Tlp</i> to about 0,5 s.</li> <li><i>F(v)</i> is minimum value selection.</li> <li>Frequency (<i>f</i>) is local (nodal) frequency.</li> <li>The model enables different values for Pe and Pm (Pm = Pe+delta P this power balance is ensured by the swing equation). But the problem is in per unit system. If Pe and Pm are per units on generator MVA base, than the input to the power transducer should be multiplied by the correction factor KN= generator MVA base /turbine mwbase and on the contrary, output should be divided by the same factor.</li> <li>The typical values are assuming parallel operation. However, the model can also be used with a set of parameters that enables island operation. The model contains the superimposed power control (because it is a normal operating regime), but it enables proportional speed control as well - Pe=(Pref-deltaf x kfcor), supposed that in the steady state delta f is close to delta omega for abs(delta f)>db1.</li> <li>The model works only under the assumption of zero resistive and mechanical losses, when in the steady state equality applies: Pe = Pm. This is based on the assumption that in the vast majority of calculations, these losses are not considered anyway, as they do not have a major effect on dynamic stability.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:38:162022-03-18 21:50:27
Diagram 'GovSteamEU' has no other changes. The shows its notes and every changed property.
▶▦GovSteamFV2i
Diagram notes (destination, redlined)
This diagram describes the GovSteamFV2 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>Valve position is determined by the time curve. The valve position is either 1 or 0.</li> <li><i>Ti</i> (Initial time to begin fast valving) is a user-defined parameteraction/input aton the timesimulation. ofThe theparameter simulation and is not exchanged. <i>Ti</i> is assumed to be 0,1 s. It is used to review the effect of the fast valving.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 21:51:372022-03-18 21:50:17
CHANGED{81894D61-1EE1-4f76-9FD9-BADCF2410D9B}
Diagram notes (destination, redlined)
This diagram describes the GovSteamFV2 turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>Valve position is determined by the time curve. The valve position is either 1 or 0.</li> <li><i>Ti</i> (Initial time to begin fast valving) is a user-defined parameteraction/input aton the timesimulation. ofThe theparameter simulation and is not exchanged. <i>Ti</i> is assumed to be 0,1 s. It is used to review the effect of the fast valving.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 21:51:372022-03-18 21:50:17
Diagram 'GovSteamFV2' has no other changes. The shows its notes and every changed property.
▶▦GovSteamFV3i
Diagram notes (destination, redlined)
This diagram describes the GovSteamFV3 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The gains <i>K1</i>, <i>K2</i>, <i>K3</i> describe the division of power output among turbine stages. Normally, <i>K1</i> + <i>K2</i> + <i>K3 </i>= 1.</li> <li>The times <i>Ta</i>, <i>Tb</i>, and <i>Tc</i> are all with respect to the initiation time.</li> <li>The value <i>Prmax</i> is a limit on the pressure in the reheater. Normally, this value should be about 1,10 PU.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. However,The ifcharacteristic <i>Pmax</i>shall >have 1,0,only thepositive inputvalues andor outputzero are(only scaledfor byone <i>Pmax</i>point). If <i>Gv1</i>all isvalues aare negativeset numberto or zero values, the defaultnonlinear curvegain (betweenis 0,0 , 0,0 and 1,0 , 1,0) will be usedbypassed.</li> <li><i>Ti </i>(initialInitial time to begin fast valving) is a user-defined parameteraction/input aton the time of the simulation. andThe itparameter is not exchanged. <i>Ti</i> is assumed to be 0,1 s. It is used to review the effect of the fast valving.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-08 09:39:042022-03-18 21:50:09
CHANGED{9B3CA587-9EA4-40d5-B91B-64E5895208F4}
Diagram notes (destination, redlined)
This diagram describes the GovSteamFV3 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The gains <i>K1</i>, <i>K2</i>, <i>K3</i> describe the division of power output among turbine stages. Normally, <i>K1</i> + <i>K2</i> + <i>K3 </i>= 1.</li> <li>The times <i>Ta</i>, <i>Tb</i>, and <i>Tc</i> are all with respect to the initiation time.</li> <li>The value <i>Prmax</i> is a limit on the pressure in the reheater. Normally, this value should be about 1,10 PU.</li> <li>The nonlinear gain between gate position and power can be input with up to 6 points. The (0,0 , 0,0) and (1,0 , 1,0) points can be assumed. The output is not allowed to go beyond 0,0 and 1,0. However,The ifcharacteristic <i>Pmax</i>shall >have 1,0,only thepositive inputvalues andor outputzero are(only scaledfor byone <i>Pmax</i>point). If <i>Gv1</i>all isvalues aare negativeset numberto or zero values, the defaultnonlinear curvegain (betweenis 0,0 , 0,0 and 1,0 , 1,0) will be usedbypassed.</li> <li><i>Ti </i>(initialInitial time to begin fast valving) is a user-defined parameteraction/input aton the time of the simulation. andThe itparameter is not exchanged. <i>Ti</i> is assumed to be 0,1 s. It is used to review the effect of the fast valving.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-08 09:39:042022-03-18 21:50:09
Diagram 'GovSteamFV3' has no other changes. The shows its notes and every changed property.
▶▦GovSteamFV4i
Diagram notes
This diagram describes the GovSteamFV4 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>This model can be used for steam units in coordinated control, not belonging to a combined-cycle power plant.</li> <li><i>omega</i> has units of per unit speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:00:582022-03-18 21:49:59
CHANGED{34F6E736-59B7-4047-879A-9CF1945755BC}
Diagram notes
This diagram describes the GovSteamFV4 turbine governor model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>PU parameters are on base of MW capability of the turbine.</li> <li>This model can be used for steam units in coordinated control, not belonging to a combined-cycle power plant.</li> <li><i>omega</i> has units of per unit speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:00:582022-03-18 21:49:59
Diagram 'GovSteamFV4' has no other changes. The shows its notes and every changed property.
▶▦GovSteamIEEE1i
Diagram notes (destination, redlined)
This diagram describes the CIM model interpretation of the IEEE steam turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>For a tandem-compound turbine the parameters <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8</i> are ignored. For a cross-compound turbine, two generators are connected to this turbine-governor model.</li> <li>Each generator shall be represented in the load flow by data on its own MVA base. The values of <i>K1</i>, <i>K3</i>, <i>K5</i>, and <i>K7</i> shall be specified to describe the proportionate development of power on the first turbine shaft. <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8 </i>shall describe the second turbine shaft. Normally <i>K1 </i>+<i> K3</i> + <i>K5</i> + <i>K7 </i>= 1,0 and <i>K2</i> + <i>K4</i> + <i>K6</i> + <i>K8 </i>= 1,0 (if second generator is present).</li> <li>The division of power between the two shafts is in proportion to the MW values of MVA bases of the two generators. The initial condition load flow should, therefore, have the two generators loaded to the same fraction of each one’s MVAMW base.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 22:03:062022-03-18 21:55:38
CHANGED{7F80EA17-B77B-41dc-BAA9-23AF5D0817F1}
Diagram notes (destination, redlined)
This diagram describes the CIM model interpretation of the IEEE steam turbine governor model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>PU parameters are on base of <i>MWbase</i>, which is normally the MW capability of the turbine.</li> <li>For a tandem-compound turbine the parameters <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8</i> are ignored. For a cross-compound turbine, two generators are connected to this turbine-governor model.</li> <li>Each generator shall be represented in the load flow by data on its own MVA base. The values of <i>K1</i>, <i>K3</i>, <i>K5</i>, and <i>K7</i> shall be specified to describe the proportionate development of power on the first turbine shaft. <i>K2</i>, <i>K4</i>, <i>K6</i>, and <i>K8 </i>shall describe the second turbine shaft. Normally <i>K1 </i>+<i> K3</i> + <i>K5</i> + <i>K7 </i>= 1,0 and <i>K2</i> + <i>K4</i> + <i>K6</i> + <i>K8 </i>= 1,0 (if second generator is present).</li> <li>The division of power between the two shafts is in proportion to the MW values of MVA bases of the two generators. The initial condition load flow should, therefore, have the two generators loaded to the same fraction of each one’s MVAMW base.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 22:03:062022-03-18 21:55:38
Diagram 'GovSteamIEEE1' has no other changes. The shows its notes and every changed property.
▶▦GovSteamSGOi
Diagram notes
This diagram describes the GovSteamSGO turbine governor model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:01:192022-03-18 21:49:50
CHANGED{04448909-5CB7-4335-825C-EBCDAD935D84}
Diagram notes
This diagram describes the GovSteamSGO turbine governor model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:01:192022-03-18 21:49:50
Diagram 'GovSteamSGO' has no other changes. The shows its notes and every changed property.
▶▦SteamTurbineGovernorDynamicsrenamed from TurbineGovernorDynamicsi
Diagram notes (destination, redlined)
This diagram shows dynamic standard model steam turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 21:48:152022-03-18 21:56:05
NameTurbineGovernorDynamicsSteamTurbineGovernorDynamics
CHANGED{D646BBA5-04C5-4745-9D16-606392088DF9}
Diagram notes (destination, redlined)
This diagram shows dynamic standard model steam turbine-governor classes and their inheritance from the TurbineGovernorDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 21:48:152022-03-18 21:56:05
NameTurbineGovernorDynamicsSteamTurbineGovernorDynamics
▦Diagram
addedremovedchangedmoved or resized
Baseline
SteamTurbineGovernorDynamics (baseline)
Destination
SteamTurbineGovernorDynamics (destination)
Connectors 2 added · 21 removed · 10 rerouted · 3 labels movedhover a connector to outline the elements it joins
addedGovSteamIEEEG1Aug – TurbineGovernorDynamics
addedGovSteamIEEETGOV5 – CrossCompoundTurbineGovernorDynamics
removed(not in this model) – TurbineGovernorDynamics
removedGovGAST – TurbineGovernorDynamics
removedGovGAST1 – TurbineGovernorDynamics
removedGovGAST2 – TurbineGovernorDynamics
removedGovGAST3 – TurbineGovernorDynamics
removedGovGAST4 – TurbineGovernorDynamics
removedGovGASTWD – TurbineGovernorDynamics
removedGovHydro1 – TurbineGovernorDynamics
removedGovHydro2 – TurbineGovernorDynamics
removedGovHydro3 – TurbineGovernorDynamics
removedGovHydro4 – TurbineGovernorDynamics
removedGovHydroDD – TurbineGovernorDynamics
removedGovHydroFrancis – TurbineGovernorDynamics
removedGovHydroIEEE0 – TurbineGovernorDynamics
removedGovHydroIEEE2 – TurbineGovernorDynamics
removedGovHydroPID – TurbineGovernorDynamics
removedGovHydroPID2 – TurbineGovernorDynamics
removedGovHydroPelton – TurbineGovernorDynamics
removedGovHydroR – TurbineGovernorDynamics
removedGovHydroWEH – TurbineGovernorDynamics
removedGovHydroWPID – TurbineGovernorDynamics
reroutedCrossCompoundTurbineGovernorDynamics – DynamicsFunctionBlock
reroutedGovCT1 – TurbineGovernorDynamics
reroutedGovCT2 – TurbineGovernorDynamics
reroutedGovSteam1 – CrossCompoundTurbineGovernorDynamics
reroutedGovSteamEU – TurbineGovernorDynamics
reroutedGovSteamFV2 – TurbineGovernorDynamics
reroutedGovSteamFV3 – TurbineGovernorDynamics
reroutedGovSteamFV4 – TurbineGovernorDynamics
reroutedGovSteamIEEE1 – CrossCompoundTurbineGovernorDynamics
reroutedGovSteamSGO – TurbineGovernorDynamics
labels movedCrossCompoundTurbineGovernorDynamics – SynchronousMachineDynamics
labels movedCrossCompoundTurbineGovernorDynamics – SynchronousMachineDynamics
labels movedSynchronousMachineDynamics – TurbineGovernorDynamics
▶▦TurbineGovernorInterconnectionAndVariablesi
Diagram notes (destination, redlined)
This diagram illustrates the inputs and outputs for a turbine-governor. Some turbine-governor models are used in cross-compound interconnections, e.g. GovSteam1, where they are connected to two generators (synchronous machines). Diagram details: <ol> <li><i>Pref </i>is usually held constant for stability analysis, but can be determined by a user-defined model or, for long-term dynamics, an area-wide automatic generation control (AGC) model. For some models, <i>Pref </i>has units of PU speed instead of PU power.</li> <li>All turbine-governor models have either mwbase or trate as a parameter. The vastparameter is specified explicitly majorityin ofthe turbine-governor models havebecause the <i>MWbase<input/i>outputs are assumed to be in the base defined by mwbase (connected generator base), the required conversions for this are to be handled by each vendor as specifically required in each software. This conversion is a parametersoftware specific interface need and this is why it is not part of any model specification. This If this parameter correspondsis present it shall correspond to GeneratingUnitRotatingMachine.ratedPowerFactor * RotatingMachine.ratedS.ratedGrossMaxP</li> <li>Some turbine governors diagrams have deltaomega as an input other fromjust theomega. ProductionIn packagegeneral, butall isturbine specifiedgovernors explicitlyconsider indeltaomega theas Dynamicsinput packageassuming tothe supportfollowing userelation ofwith athe differentspeed: valuedeltaomega by= transient(speed analysis– tools,1) ifin neededpu.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:47:202022-03-18 21:56:27
CHANGED{741D4617-BC05-4225-A5C8-382BEB02A4A5}
Diagram notes (destination, redlined)
This diagram illustrates the inputs and outputs for a turbine-governor. Some turbine-governor models are used in cross-compound interconnections, e.g. GovSteam1, where they are connected to two generators (synchronous machines). Diagram details: <ol> <li><i>Pref </i>is usually held constant for stability analysis, but can be determined by a user-defined model or, for long-term dynamics, an area-wide automatic generation control (AGC) model. For some models, <i>Pref </i>has units of PU speed instead of PU power.</li> <li>All turbine-governor models have either mwbase or trate as a parameter. The vastparameter is specified explicitly majorityin ofthe turbine-governor models havebecause the <i>MWbase<input/i>outputs are assumed to be in the base defined by mwbase (connected generator base), the required conversions for this are to be handled by each vendor as specifically required in each software. This conversion is a parametersoftware specific interface need and this is why it is not part of any model specification. This If this parameter correspondsis present it shall correspond to GeneratingUnitRotatingMachine.ratedPowerFactor * RotatingMachine.ratedS.ratedGrossMaxP</li> <li>Some turbine governors diagrams have deltaomega as an input other fromjust theomega. ProductionIn packagegeneral, butall isturbine specifiedgovernors explicitlyconsider indeltaomega theas Dynamicsinput packageassuming tothe supportfollowing userelation ofwith athe differentspeed: valuedeltaomega by= transient(speed analysis– tools,1) ifin neededpu.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:47:202022-03-18 21:56:27
Diagram 'TurbineGovernorInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶TurbineLoadControllerDynamicsi
Package notes
A turbine load controller acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/TurbineLoadControllerDynamics/1.0
version(no tag)1.0.0
CHANGED{F0E43C7F-6E03-4b93-B0AF-2111023CA155}
Package notes
A turbine load controller acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/TurbineLoadControllerDynamics/1.0
version(no tag)1.0.0
Changed classes (1)
▶⚙TurbLCFB1i
Class notes (destination, redlined)
Turbine load controller model developed by WECC. This model represents a supervisory turbine load controller that acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference. This model is intended to represent slow reset 'outer loop' controllers managing the action of the turbine governor.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{B04FCA7C-DB3E-4dcc-B991-F9B87BBC1330}
Class notes (destination, redlined)
Turbine load controller model developed by WECC. This model represents a supervisory turbine load controller that acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference. This model is intended to represent slow reset 'outer loop' controllers managing the action of the turbine governor.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
emaxi{5293C632-28A0-45d4-9820-4AF63CE2AFC8}show detailsPU [0..1]PU [0..1]Maximum control error (<i>Emax</i>) (see parameter detail 4). Typical value = 0,021.
Attribute notes (destination, redlined)
Maximum control error (<i>Emax</i>) (see parameter detail 4). Typical value = 0,021.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
irmaxi{594A2700-90F0-4ca2-9FB3-0FAD84B96E2C}show detailsPU [0..1]PU [0..1]Maximum turbine speed/load reference bias (<i>Irmax</i>) (see parameter detail 3). Typical value = 0,025. Typical range is 0.025 to 0.05.
Attribute notes (destination, redlined)
Maximum turbine speed/load reference bias (<i>Irmax</i>) (see parameter detail 3). Typical value = 0,025. Typical range is 0.025 to 0.05.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
kii{5AA55CDC-9469-4f03-B327-AE36DD877738}show detailsPU [0..1]PU [0..1]Integral gain (<i>Ki</i>). Typical valuerange is 0,005 =to 0,2.
Attribute notes (destination, redlined)
Integral gain (<i>Ki</i>). Typical valuerange is 0,005 =to 0,2.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
tpeleci{D74FEDF5-5775-47aa-B051-49EF1F447195}show detailsSeconds [0..1]Seconds [0..1]Power transducer time constant (<i>Tpelec</i>) (>= 0). Typical value = 02. Typical range is 2 to 5.
Attribute notes (destination, redlined)
Power transducer time constant (<i>Tpelec</i>) (>= 0). Typical value = 02. Typical range is 2 to 5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
Changed diagrams (2)
▶▦TurbineLoadControllerDynamicsi
Diagram notes
This diagram shows dynamic standard model turbine load controller classes and their inheritance from the TurbineLoadControllerDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-09-12 09:44:452022-03-18 22:26:20
CHANGED{EA37FCB1-4727-4ecd-94F5-0C25650651A1}
Diagram notes
This diagram shows dynamic standard model turbine load controller classes and their inheritance from the TurbineLoadControllerDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2016-09-12 09:44:452022-03-18 22:26:20
▦Diagram
addedchanged
Baseline
TurbineLoadControllerDynamics (baseline)
Destination
TurbineLoadControllerDynamics (destination)
▶▦TurbLCFB1i
Diagram notes
This diagram describes the TurbLCFB1 turbine load controller model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The load reference of this supervisory load control loop is accessible as the parameter, <i>Pmwset</i>. <i>Pmwset </i>is given a value automatically when the model is initialized. This value overwrites any value entered prior to initialization.</li> <li>The controller acts by applying a bias to the turbine-governor speed load reference, P<i>ref</i>. This reference is initialized in the normal manner by the turbine-governor model.</li> <li>The output of the controller is limited to plus or minus <i>Irmax</i>. To prevent the controller from adjusting the turbine power excessively, <i>Irmax</i> should not exceed approximately one half of the governor droop or approximately 0,025 PU.</li> <li>The error limit, <i>Emax</i>, is intended to set a maximum rate of change of turbine power. If limitation of load change rate is desired, <i>Emax</i> should be set such that <i>Emax</i> = (max rate, PU / s) x (droop of governor in PU) / <i>Ki</i>. Note that governor droop used in this calculation shall be in PU relative to the base power, <i>MWbase</i>, of the turbine. Note, also, that some governor models (such as GovSteamIEEE1) have their droop specified by the value of a gain whose value is the reciprocal of the droop. For example, in GovSteamIEEE1 the droop is specified by the gain, <i>K</i>, whose typical value is 1 / 0,04 = 25.</li> <li>This model recognizes the two alternative ways of specifying the turbine-governor load reference. In models such as GovCT1 and GovHydro1, the reference is a speed setpoint. In other models such as GovSteamIEEE1, the reference is a PU load value. The references are generally as follows: 1) speed reference (1 + (initial power or valve position) x (droop)), 2) load reference (0 + (initial power or valve position)). The parameters of TurbLCFB1 shall always be set on the basis of a governor speed reference.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:09:302022-03-18 22:26:14
CHANGED{4A7FB195-8B7F-4e30-AD41-EDEB07530A49}
Diagram notes
This diagram describes the TurbLCFB1 turbine load controller model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li>The load reference of this supervisory load control loop is accessible as the parameter, <i>Pmwset</i>. <i>Pmwset </i>is given a value automatically when the model is initialized. This value overwrites any value entered prior to initialization.</li> <li>The controller acts by applying a bias to the turbine-governor speed load reference, P<i>ref</i>. This reference is initialized in the normal manner by the turbine-governor model.</li> <li>The output of the controller is limited to plus or minus <i>Irmax</i>. To prevent the controller from adjusting the turbine power excessively, <i>Irmax</i> should not exceed approximately one half of the governor droop or approximately 0,025 PU.</li> <li>The error limit, <i>Emax</i>, is intended to set a maximum rate of change of turbine power. If limitation of load change rate is desired, <i>Emax</i> should be set such that <i>Emax</i> = (max rate, PU / s) x (droop of governor in PU) / <i>Ki</i>. Note that governor droop used in this calculation shall be in PU relative to the base power, <i>MWbase</i>, of the turbine. Note, also, that some governor models (such as GovSteamIEEE1) have their droop specified by the value of a gain whose value is the reciprocal of the droop. For example, in GovSteamIEEE1 the droop is specified by the gain, <i>K</i>, whose typical value is 1 / 0,04 = 25.</li> <li>This model recognizes the two alternative ways of specifying the turbine-governor load reference. In models such as GovCT1 and GovHydro1, the reference is a speed setpoint. In other models such as GovSteamIEEE1, the reference is a PU load value. The references are generally as follows: 1) speed reference (1 + (initial power or valve position) x (droop)), 2) load reference (0 + (initial power or valve position)). The parameters of TurbLCFB1 shall always be set on the basis of a governor speed reference.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:09:302022-03-18 22:26:14
Diagram 'TurbLCFB1' has no other changes. The shows its notes and every changed property.
▶MechanicalLoadDynamicsi
Package notes
A mechanical load represents the variation in a motor's shaft torque or power as a function of shaft speed.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/MechanicalLoadDynamics/1.0
version(no tag)1.0.0
CHANGED{54ED4DD8-2593-43f5-9A32-43679D605D36}
Package notes
A mechanical load represents the variation in a motor's shaft torque or power as a function of shaft speed.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/MechanicalLoadDynamics/1.0
version(no tag)1.0.0
Changed classes (1)
▶⚙MechanicalLoadDynamicsi
Class notes
Mechanical load function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{3C5B6644-5E53-4330-8E77-595A2B1335DD}
Class notes
Mechanical load function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
⇄Links
BaselineMechanicalLoadDynamics role MechanicalLoadDynamics [0..1] → SynchronousMachineDynamics role SynchronousMachineDynamics [0..1]
→
DestinationMechanicalLoadDynamics role MechanicalLoadDynamics [0..1] → SynchronousMachineDynamics role SynchronousMachineDynamics [0..1]
Source end
no changes
Target end — SynchronousMachineDynamics
BaselineDestination
RoleNoteSynchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or AsynchronousMachineDyanmics.Synchronous machine model with which this mechanical load model is associated. MechanicalLoadDynamics shall have either an association to SynchronousMachineDynamics or AsynchronousMachineDyanmicsAsynchronousMachineDynamics.
Changed diagrams (3)
▶▦MechanicalLoadDynamicsi
Diagram notes
This diagram shows dynamic standard model mechanical load classes and their inheritance from the MechanicalLoadDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-09-15 22:01:522022-03-18 22:26:36
CHANGED{5653B8A5-52C9-401e-811E-69E155E17018}
Diagram notes
This diagram shows dynamic standard model mechanical load classes and their inheritance from the MechanicalLoadDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2013-09-15 22:01:522022-03-18 22:26:36
▦Diagram
addedchanged
Baseline
MechanicalLoadDynamics (baseline)
Destination
MechanicalLoadDynamics (destination)
▶▦MechanicalLoadEquationsi
Diagram notes
This diagram illustrates the equations for a mechanical load.
Diagram metadata — changes
BaselineDestination
ModifiedDate2014-12-14 11:57:112022-03-18 22:26:43
CHANGED{2AB508AF-0216-42da-B963-C94736211F6F}
Diagram notes
This diagram illustrates the equations for a mechanical load.
▤Metadata
BaselineDestination
ModifiedDate2014-12-14 11:57:112022-03-18 22:26:43
Diagram 'MechanicalLoadEquations' has no other changes. The shows its notes and every changed property.
▶▦MechanicalLoadInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for a mechanical load.
Diagram metadata — changes
BaselineDestination
ModifiedDate2012-08-01 15:57:092022-03-18 22:26:49
CHANGED{6F02C65D-B6D1-405f-805F-26CE81F5A037}
Diagram notes
This diagram illustrates the inputs and outputs for a mechanical load.
▤Metadata
BaselineDestination
ModifiedDate2012-08-01 15:57:092022-03-18 22:26:49
Diagram 'MechanicalLoadInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶ExcitationSystemDynamicsi
Package notes (destination, redlined)
The excitation system model provides the field voltage (<i>Efd</i>) for a synchronous machine model. It is linked to a specific generator (synchronous machine). The representation of all limits used by the models (not including IEEE standard models) shall comply with the representation defined in the Annex E of the IEEE 421.5-2005, unless specified differently in the documentation of the model. The parameters are different for each excitation system model; the same parameter name can have different meaning in different models.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/ExcitationSystemDynamics/1.0
version(no tag)1.0.0
CHANGED{829F67E7-F698-4aa7-95C2-13C616AB6B78}
Package notes (destination, redlined)
The excitation system model provides the field voltage (<i>Efd</i>) for a synchronous machine model. It is linked to a specific generator (synchronous machine). The representation of all limits used by the models (not including IEEE standard models) shall comply with the representation defined in the Annex E of the IEEE 421.5-2005, unless specified differently in the documentation of the model. The parameters are different for each excitation system model; the same parameter name can have different meaning in different models.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/ExcitationSystemDynamics/1.0
version(no tag)1.0.0
▶IEEE4215from2005i
Package notes
Excitation system models from IEEE 421.5-2005.
Package metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
IsLeaffalse
IsRootfalse
NameIEEE4215from2005
ParentPackageExcitationSystemDynamics
Phase1.0
Scopepublic
StatusProposed
TypePackage
Version1.0
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/IEEE4215from2005/1.0
version(no tag)1.0.0
ADDED{D22779BB-015E-4250-9959-87234042A65F}
Package notes
Excitation system models from IEEE 421.5-2005.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/IEEE4215from2005/1.0
version(no tag)1.0.0
Moved classes (20)
▶⚙ExcIEEEAC1Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC1A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC1A. These excitation systems consist of an alternator main exciter with non-controlled rectifiers. Reference: IEEE 421.5-2005, 6.1. According to IEEE 421.5-2016, 7.2 the AC1A excitation system model is being superseded by the model AC1C (ExcIEEEAC1C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{ACDB84C3-576D-4700-8C29-C7C1762CCCC9}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC1A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC1A. These excitation systems consist of an alternator main exciter with non-controlled rectifiers. Reference: IEEE 421.5-2005, 6.1. According to IEEE 421.5-2016, 7.2 the AC1A excitation system model is being superseded by the model AC1C (ExcIEEEAC1C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC1A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC2Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC2A model. The model represents a high initial response field-controlled alternator-rectifier excitation system. The alternator main exciter is used with non-controlled rectifiers. The type AC2A model is similar to that of type AC1A except for the inclusion of exciter time constant compensation and exciter field current limiting elements. Reference: IEEE 421.5-2005, 6.2. According to IEEE 421.5-2016, 7.4 the AC2A excitation system model is being superseded by the model AC2C (ExcIEEEAC2C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{872A1C8E-D47A-438c-9AE6-CC6471983F4A}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC2A model. The model represents a high initial response field-controlled alternator-rectifier excitation system. The alternator main exciter is used with non-controlled rectifiers. The type AC2A model is similar to that of type AC1A except for the inclusion of exciter time constant compensation and exciter field current limiting elements. Reference: IEEE 421.5-2005, 6.2. According to IEEE 421.5-2016, 7.4 the AC2A excitation system model is being superseded by the model AC2C (ExcIEEEAC2C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC2A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC3Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC3A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC3A. These excitation systems include an alternator main exciter with non-controlled rectifiers. The exciter employs self-excitation, and the voltage regulator power is derived from the exciter output voltage. Therefore, this system has an additional nonlinearity, simulated by the use of a multiplier whose inputs are the voltage regulator command signal, <i>Va</i>, and the exciter output voltage, <i>Efd</i>, times <i>K</i><i><sub>R</sub></i>. This model is applicable to excitation systems employing static voltage regulators. Reference: IEEE 421.5-2005, 6.3. According to IEEE 421.5-2016, 7.6 the AC3A excitation system model is being superseded by the model AC3C (ExcIEEEAC3C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{F4168622-5B5F-4acf-A248-E670C038660A}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC3A model. The model represents the field-controlled alternator-rectifier excitation systems designated type AC3A. These excitation systems include an alternator main exciter with non-controlled rectifiers. The exciter employs self-excitation, and the voltage regulator power is derived from the exciter output voltage. Therefore, this system has an additional nonlinearity, simulated by the use of a multiplier whose inputs are the voltage regulator command signal, <i>Va</i>, and the exciter output voltage, <i>Efd</i>, times <i>K</i><i><sub>R</sub></i>. This model is applicable to excitation systems employing static voltage regulators. Reference: IEEE 421.5-2005, 6.3. According to IEEE 421.5-2016, 7.6 the AC3A excitation system model is being superseded by the model AC3C (ExcIEEEAC3C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC3A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC4Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC4A model. The model represents type AC4A alternator-supplied controlled-rectifier excitation system which is quite different from the other types of AC systems. This high initial response excitation system utilizes a full thyristor bridge in the exciter output circuit. The voltage regulator controls the firing of the thyristor bridges. The exciter alternator uses an independent voltage regulator to control its output voltage to a constant value. These effects are not modelled; however, transient loading effects on the exciter alternator are included. Reference: IEEE 421.5-2005, 6.4. According to IEEE 421.5-2016, 7.8 the AC4A excitation system model is being superseded by the model AC4C (ExcIEEEAC4C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{A19ECF3E-99EC-46c1-A2E0-892E351F1F79}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC4A model. The model represents type AC4A alternator-supplied controlled-rectifier excitation system which is quite different from the other types of AC systems. This high initial response excitation system utilizes a full thyristor bridge in the exciter output circuit. The voltage regulator controls the firing of the thyristor bridges. The exciter alternator uses an independent voltage regulator to control its output voltage to a constant value. These effects are not modelled; however, transient loading effects on the exciter alternator are included. Reference: IEEE 421.5-2005, 6.4. According to IEEE 421.5-2016, 7.8 the AC4A excitation system model is being superseded by the model AC4C (ExcIEEEAC4C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC4A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC5Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC5A model. The model represents a simplified model for brushless excitation systems. The regulator is supplied from a source, such as a permanent magnet generator, which is not affected by system disturbances. Unlike other AC models, this model uses loaded rather than open circuit exciter saturation data in the same way as it is used for the DC models. Because the model has been widely implemented by the industry, it is sometimes used to represent other types of systems when either detailed data for them are not available or simplified models are required. Reference: IEEE 421.5-2005, 6.5. According to IEEE 421.5-2016, 7.10 the AC5A excitation system model is being superseded by the model AC5C (ExcIEEEAC5C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{B8C00890-B9AB-4687-8B3C-B194D0BBD8B7}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC5A model. The model represents a simplified model for brushless excitation systems. The regulator is supplied from a source, such as a permanent magnet generator, which is not affected by system disturbances. Unlike other AC models, this model uses loaded rather than open circuit exciter saturation data in the same way as it is used for the DC models. Because the model has been widely implemented by the industry, it is sometimes used to represent other types of systems when either detailed data for them are not available or simplified models are required. Reference: IEEE 421.5-2005, 6.5. According to IEEE 421.5-2016, 7.10 the AC5A excitation system model is being superseded by the model AC5C (ExcIEEEAC5C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC5A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC6Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type AC6A model. The model represents field-controlled alternator-rectifier excitation systems with system-supplied electronic voltage regulators. The maximum output of the regulator, <i>V</i><i><sub>R</sub></i>, is a function of terminal voltage, <i>V</i><i><sub>T</sub></i>. The field current limiter included in the original model AC6A remains in the 2005 update. Reference: IEEE 421.5-2005, 6.6. According to IEEE 421.5-2016, 7.12 the AC6A excitation system model is being superseded by the model AC6C (ExcIEEEAC6C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{52AB8022-3DF9-4f56-8342-FBBD1650B319}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC6A model. The model represents field-controlled alternator-rectifier excitation systems with system-supplied electronic voltage regulators. The maximum output of the regulator, <i>V</i><i><sub>R</sub></i>, is a function of terminal voltage, <i>V</i><i><sub>T</sub></i>. The field current limiter included in the original model AC6A remains in the 2005 update. Reference: IEEE 421.5-2005, 6.6. According to IEEE 421.5-2016, 7.12 the AC6A excitation system model is being superseded by the model AC6C (ExcIEEEAC6C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC6A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC7Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type AC7B model. The model represents excitation systems which consist of an AC alternator with either stationary or rotating rectifiers to produce the DC field requirements. It is an upgrade to earlier AC excitation systems, which replace only the controls but retain the AC alternator and diode rectifier bridge. Reference: IEEE 421.5-2005, 6.7. Note, however, that in IEEE 421.5-2005, the [1 / <i>sT</i><i><sub>E</sub></i>] block is shown as [1 / (1 + <i>sT</i><i><sub>E</sub></i>)], which is incorrect. According to IEEE 421.5-2016, 7.14 the AC7B excitation system model is being superseded by the model AC7C (ExcIEEEAC7C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{7FA5C845-958C-4fde-823A-F43B7912A2C0}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC7B model. The model represents excitation systems which consist of an AC alternator with either stationary or rotating rectifiers to produce the DC field requirements. It is an upgrade to earlier AC excitation systems, which replace only the controls but retain the AC alternator and diode rectifier bridge. Reference: IEEE 421.5-2005, 6.7. Note, however, that in IEEE 421.5-2005, the [1 / <i>sT</i><i><sub>E</sub></i>] block is shown as [1 / (1 + <i>sT</i><i><sub>E</sub></i>)], which is incorrect. According to IEEE 421.5-2016, 7.14 the AC7B excitation system model is being superseded by the model AC7C (ExcIEEEAC7C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC7B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEAC8Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type AC8B model. This model represents a PID voltage regulator with either a brushless exciter or DC exciter. The AVR in this model consists of PID control, with separate constants for the proportional (<i>K</i><i><sub>PR</sub></i>), integral (<i>K</i><i><sub>IR</sub></i>), and derivative (<i>K</i><i><sub>DR</sub></i>) gains. The representation of the brushless exciter (<i>T</i><i><sub>E</sub></i>, <i>K</i><i><sub>E</sub></i>, <i>S</i><i><sub>E</sub></i>, <i>K</i><i><sub>C</sub></i>, <i>K</i><i><sub>D</sub></i>) is similar to the model type AC2A. The type AC8B model can be used to represent static voltage regulators applied to brushless excitation systems. Digitally based voltage regulators feeding DC rotating main exciters can be represented with the AC type AC8B model with the parameters <i>K</i><i><sub>C</sub></i> and <i>K</i><i><sub>D</sub></i> set to 0. For thyristor power stages fed from the generator terminals, the limits <i>V</i><i><sub>RMAX</sub></i> and <i>V</i><i><sub>RMIN</sub></i><i> </i>should be a function of terminal voltage: V<i><sub>T</sub></i> x <i>V</i><i><sub>RMAX</sub></i><sub> </sub>and <i>V</i><i><sub>T</sub></i> x <i>V</i><i><sub>RMIN</sub></i>. Reference: IEEE 421.5-2005, 6.8. According to IEEE 421.5-2016, 7.16 the AC8B excitation system model is being superseded by the model AC8C (ExcIEEEAC8C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{5A5BF11A-2D01-4ab7-9F3E-6F9D0EBA1054}
Class notes (destination, redlined)
IEEE 421.5-2005 type AC8B model. This model represents a PID voltage regulator with either a brushless exciter or DC exciter. The AVR in this model consists of PID control, with separate constants for the proportional (<i>K</i><i><sub>PR</sub></i>), integral (<i>K</i><i><sub>IR</sub></i>), and derivative (<i>K</i><i><sub>DR</sub></i>) gains. The representation of the brushless exciter (<i>T</i><i><sub>E</sub></i>, <i>K</i><i><sub>E</sub></i>, <i>S</i><i><sub>E</sub></i>, <i>K</i><i><sub>C</sub></i>, <i>K</i><i><sub>D</sub></i>) is similar to the model type AC2A. The type AC8B model can be used to represent static voltage regulators applied to brushless excitation systems. Digitally based voltage regulators feeding DC rotating main exciters can be represented with the AC type AC8B model with the parameters <i>K</i><i><sub>C</sub></i> and <i>K</i><i><sub>D</sub></i> set to 0. For thyristor power stages fed from the generator terminals, the limits <i>V</i><i><sub>RMAX</sub></i> and <i>V</i><i><sub>RMIN</sub></i><i> </i>should be a function of terminal voltage: V<i><sub>T</sub></i> x <i>V</i><i><sub>RMAX</sub></i><sub> </sub>and <i>V</i><i><sub>T</sub></i> x <i>V</i><i><sub>RMIN</sub></i>. Reference: IEEE 421.5-2005, 6.8. According to IEEE 421.5-2016, 7.16 the AC8B excitation system model is being superseded by the model AC8C (ExcIEEEAC8C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEAC8B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEDC1Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type DC1A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators (especially the direct-acting rheostatic, rotating amplifier, and magnetic amplifier types). Because this model has been widely implemented by the industry, it is sometimes used to represent other types of systems when detailed data for them are not available or when a simplified model is required. Reference: IEEE 421.5-2005, 5.1. According to IEEE 421.5-2016, 6.2 the DC1A excitation system model is being superseded by the model DC1C (ExcIEEEDC1C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{8045C2BD-5BDB-401f-BB79-0FA9E8E30E27}
Class notes (destination, redlined)
IEEE 421.5-2005 type DC1A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators (especially the direct-acting rheostatic, rotating amplifier, and magnetic amplifier types). Because this model has been widely implemented by the industry, it is sometimes used to represent other types of systems when detailed data for them are not available or when a simplified model is required. Reference: IEEE 421.5-2005, 5.1. According to IEEE 421.5-2016, 6.2 the DC1A excitation system model is being superseded by the model DC1C (ExcIEEEDC1C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
exclimi{A8CC72E6-B221-4df6-8512-901EC73B106A}show detailsBoolean [0..1]Boolean [0..1]An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true.
Attribute notes (destination, redlined)
An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcIEEEDC2Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type DC2A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators having supplies obtained from the generator or auxiliary bus. It differs from the type DC1A model only in the voltage regulator output limits, which are now proportional to terminal voltage <i>V</i><i><sub>T</sub></i>. It is representative of solid-state replacements for various forms of older mechanical and rotating amplifier regulating equipment connected to DC commutator exciters. Reference: IEEE 421.5-2005, 5.2. According to IEEE 421.5-2016, 6.4 the DC2A excitation system model is being superseded by the model DC2C (ExcIEEEDC2C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{3D715368-2991-450d-B9BB-F687CD39CD43}
Class notes (destination, redlined)
IEEE 421.5-2005 type DC2A model. This model represents field-controlled DC commutator exciters with continuously acting voltage regulators having supplies obtained from the generator or auxiliary bus. It differs from the type DC1A model only in the voltage regulator output limits, which are now proportional to terminal voltage <i>V</i><i><sub>T</sub></i>. It is representative of solid-state replacements for various forms of older mechanical and rotating amplifier regulating equipment connected to DC commutator exciters. Reference: IEEE 421.5-2005, 5.2. According to IEEE 421.5-2016, 6.4 the DC2A excitation system model is being superseded by the model DC2C (ExcIEEEDC2C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
exclimi{AE32601D-3E52-4ba7-ADCA-D05656320C2B}show detailsPU [0..1]PU [0..1]An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. Typical value = - 999 which means that there is no limit applied.
Attribute notes (destination, redlined)
An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. Typical value = - 999 which means that there is no limit applied.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcIEEEDC3Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type DC3A model. This model represents older systems, in particular those DC commutator exciters with non-continuously acting regulators that were commonly used before the development of the continuously acting varieties. These systems respond at basically two different rates, depending upon the magnitude of voltage error. For small errors, adjustment is made periodically with a signal to a motor-operated rheostat. Larger errors cause resistors to be quickly shorted or inserted and a strong forcing signal applied to the exciter. Continuous motion of the motor-operated rheostat occurs for these larger error signals, even though it is bypassed by contactor action. Reference: IEEE 421.5-2005, 5.3 and IEEE 421.5-2016, 6.6.
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{BD327C73-BB24-4204-81F0-1D7C0CBE4B73}
Class notes (destination, redlined)
IEEE 421.5-2005 type DC3A model. This model represents older systems, in particular those DC commutator exciters with non-continuously acting regulators that were commonly used before the development of the continuously acting varieties. These systems respond at basically two different rates, depending upon the magnitude of voltage error. For small errors, adjustment is made periodically with a signal to a motor-operated rheostat. Larger errors cause resistors to be quickly shorted or inserted and a strong forcing signal applied to the exciter. Continuous motion of the motor-operated rheostat occurs for these larger error signals, even though it is bypassed by contactor action. Reference: IEEE 421.5-2005, 5.3 and IEEE 421.5-2016, 6.6.
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
exclimi{EE0498C2-5761-48f8-AA0B-F9F0683C01D4}show detailsBoolean [0..1]Boolean [0..1]An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true.
Attribute notes (destination, redlined)
An additional attribute (<i>exclim</i>) not defined in IEEE 421.5-2005. IEEE standard is ambiguous about lower limit on exciter output. true = a lower limit of zero is applied to integrator output false = a lower limit of zero is not applied to integrator output. Typical value = true.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcIEEEDC4Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type DC4B model. These excitation systems utilize a field-controlled DC commutator exciter with a continuously acting voltage regulator having supplies obtained from the generator or auxiliary bus. Parameter details: <ol> <li>The sign of the signal Voel is not correct in IEEE 421.5-2005. The sign in IEEE 421.5-2016 shall be used.</li> </ol> Reference: IEEE 421.5-2005, 5.4. According to IEEE 421.5-2016, 6.7 the DC4B excitation system model is being superseded by the model DC4C (ExcIEEEDC4C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{7E27C1F0-2917-4f37-8B8F-629F0F437CBF}
Class notes (destination, redlined)
IEEE 421.5-2005 type DC4B model. These excitation systems utilize a field-controlled DC commutator exciter with a continuously acting voltage regulator having supplies obtained from the generator or auxiliary bus. Parameter details: <ol> <li>The sign of the signal Voel is not correct in IEEE 421.5-2005. The sign in IEEE 421.5-2016 shall be used.</li> </ol> Reference: IEEE 421.5-2005, 5.4. According to IEEE 421.5-2016, 6.7 the DC4B excitation system model is being superseded by the model DC4C (ExcIEEEDC4C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEDC4B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST1Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type ST1A model. This model represents systems in which excitation power is supplied through a transformer from the generator terminals (or the unit’s auxiliary bus) and is regulated by a controlled rectifier. The maximum exciter voltage available from such systems is directly related to the generator terminal voltage. Reference: IEEE 421.5-2005, 7.1. According to IEEE 421.5-2016, 8.2 the ST1A excitation system model is being superseded by the model ST1C (ExcIEEEST1C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{538E9666-4A7D-4819-9C99-E8601AFE86B3}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST1A model. This model represents systems in which excitation power is supplied through a transformer from the generator terminals (or the unit’s auxiliary bus) and is regulated by a controlled rectifier. The maximum exciter voltage available from such systems is directly related to the generator terminal voltage. Reference: IEEE 421.5-2005, 7.1. According to IEEE 421.5-2016, 8.2 the ST1A excitation system model is being superseded by the model ST1C (ExcIEEEST1C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST1A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST1AUELselectorKind«enumeration»i
Class notes
Types of connections for the UEL input used in ExcIEEEST1A.
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{1A5A9C7E-881D-4271-A694-3409A68164BC}
Class notes
Types of connections for the UEL input used in ExcIEEEST1A.
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST1AUELselectorKind' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST2Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type ST2A model. Some static systems use both current and voltage sources (generator terminal quantities) to comprise the power source. The regulator controls the exciter output through controlled saturation of the power transformer components. These compound-source rectifier excitation systems are designated type ST2A and are represented by ExcIEEEST2A. Reference: IEEE 421.5-2005, 7.2. According to IEEE 421.5-2016, 8.4 the ST2A excitation system model is being superseded by the model ST2C (ExcIEEEST2C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{56B255D8-1684-4542-B654-D5357CAB39A0}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST2A model. Some static systems use both current and voltage sources (generator terminal quantities) to comprise the power source. The regulator controls the exciter output through controlled saturation of the power transformer components. These compound-source rectifier excitation systems are designated type ST2A and are represented by ExcIEEEST2A. Reference: IEEE 421.5-2005, 7.2. According to IEEE 421.5-2016, 8.4 the ST2A excitation system model is being superseded by the model ST2C (ExcIEEEST2C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST2A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST3Ai
Class notes (destination, redlined)
IEEE 421.5-2005 type ST3A model. Some static systems utilize a field voltage control loop to linearize the exciter control characteristic. This also makes the output independent of supply source variations until supply limitations are reached. These systems utilize a variety of controlled-rectifier designs: full thyristor complements or hybrid bridges in either series or shunt configurations. The power source can consist of only a potential source, either fed from the machine terminals or from internal windings. Some designs can have compound power sources utilizing both machine potential and current. These power sources are represented as phasor combinations of machine terminal current and voltage and are accommodated by suitable parameters in model type ST3A which is represented by ExcIEEEST3A. Reference: IEEE 421.5-2005, 7.3. According to IEEE 421.5-2016, 8.6 the ST3A excitation system model is being superseded by the model ST3C (ExcIEEEST3C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{BE50DBC0-E168-4afe-A988-66841022814A}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST3A model. Some static systems utilize a field voltage control loop to linearize the exciter control characteristic. This also makes the output independent of supply source variations until supply limitations are reached. These systems utilize a variety of controlled-rectifier designs: full thyristor complements or hybrid bridges in either series or shunt configurations. The power source can consist of only a potential source, either fed from the machine terminals or from internal windings. Some designs can have compound power sources utilizing both machine potential and current. These power sources are represented as phasor combinations of machine terminal current and voltage and are accommodated by suitable parameters in model type ST3A which is represented by ExcIEEEST3A. Reference: IEEE 421.5-2005, 7.3. According to IEEE 421.5-2016, 8.6 the ST3A excitation system model is being superseded by the model ST3C (ExcIEEEST3C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST3A' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST4Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type ST4B model. This model is a variation of the type ST3A model, with a proportional plus integral (PI) regulator block replacing the lag-lead regulator characteristic that is in the ST3A model. Both potential and compound source rectifier excitation systems are modelled. The PI regulator blocks have non-windup limits that are represented. The voltage regulator of this model is typically implemented digitally. Reference: IEEE 421.5-2005, 7.4. According to IEEE 421.5-2016, 8.8 the ST4B excitation system model is being superseded by the model ST4C (ExcIEEEST4C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{9245EED1-30E1-4f2f-9988-4F1BB548767B}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST4B model. This model is a variation of the type ST3A model, with a proportional plus integral (PI) regulator block replacing the lag-lead regulator characteristic that is in the ST3A model. Both potential and compound source rectifier excitation systems are modelled. The PI regulator blocks have non-windup limits that are represented. The voltage regulator of this model is typically implemented digitally. Reference: IEEE 421.5-2005, 7.4. According to IEEE 421.5-2016, 8.8 the ST4B excitation system model is being superseded by the model ST4C (ExcIEEEST4C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST4B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST5Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type ST5B model. The type ST5B excitation system is a variation of the type ST1A model, with alternative overexcitation and underexcitation inputs and additional limits. The block diagram in the IEEE 421.5 standard has input signal <i>Vc </i>and does not indicate the summation point with <i>Vref</i>. The implementation of the ExcIEEEST5B shall consider summation point with <i>Vref</i>. Reference: IEEE 421.5-2005, 7.5. According to IEEE 421.5-2016, 8.10 the ST5B excitation system model is being superseded by the model ST5C (ExcIEEEST5C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{A3248F33-3B25-4879-9B29-C0E09FAF8695}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST5B model. The type ST5B excitation system is a variation of the type ST1A model, with alternative overexcitation and underexcitation inputs and additional limits. The block diagram in the IEEE 421.5 standard has input signal <i>Vc </i>and does not indicate the summation point with <i>Vref</i>. The implementation of the ExcIEEEST5B shall consider summation point with <i>Vref</i>. Reference: IEEE 421.5-2005, 7.5. According to IEEE 421.5-2016, 8.10 the ST5B excitation system model is being superseded by the model ST5C (ExcIEEEST5C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST5B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST6Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type ST6B model. This model consists of a PI voltage regulator with an inner loop field voltage regulator and pre-control. The field voltage regulator implements a proportional control. The pre-control and the delay in the feedback circuit increase the dynamic response. Parameter details: <ol> <li>The sign of the signal Voel is not correct in IEEE 421.5-2005. The sign in IEEE 421.5-2016 shall be used.</li> </ol> Reference: IEEE 421.5-2005, 7.6. According to IEEE 421.5-2016, 8.12 the ST6B excitation system model is being superseded by the model ST6C (ExcIEEEST6C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{7A625070-2B4A-48c0-BB20-C7C7DD709BC5}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST6B model. This model consists of a PI voltage regulator with an inner loop field voltage regulator and pre-control. The field voltage regulator implements a proportional control. The pre-control and the delay in the feedback circuit increase the dynamic response. Parameter details: <ol> <li>The sign of the signal Voel is not correct in IEEE 421.5-2005. The sign in IEEE 421.5-2016 shall be used.</li> </ol> Reference: IEEE 421.5-2005, 7.6. According to IEEE 421.5-2016, 8.12 the ST6B excitation system model is being superseded by the model ST6C (ExcIEEEST6C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST6B' has no other changes. The shows its notes and every changed property.
▶⚙ExcIEEEST7Bi
Class notes (destination, redlined)
IEEE 421.5-2005 type ST7B model. This model is representative of static potential-source excitation systems. In this system, the AVR consists of a PI voltage regulator. A phase lead-lag filter in series allows the introduction of a derivative function, typically used with brushless excitation systems. In that case, the regulator is of the PID type. In addition, the terminal voltage channel includes a phase lead-lag filter. The AVR includes the appropriate inputs on its reference for overexcitation limiter (OEL1), underexcitation limiter (UEL), stator current limiter (SCL), and current compensator (DROOP). All these limitations, when they work at voltage reference level, keep the PSS (VS signal from PSS) in operation. However, the UEL limitation can also be transferred to the high value (HV) gate acting on the output signal. In addition, the output signal passes through a low value (LV) gate for a ceiling overexcitation limiter (OEL2). Reference: IEEE 421.5-2005, 7.7. According to IEEE 421.5-2016, 8.14 the ST7B excitation system model is being superseded by the model ST7C (ExcIEEEST7C).
Class metadata — changes
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Tagged values — changes
BaselineDestination
no changes
MOVEDfrom ExcitationSystemDynamics{2855D47A-633A-4fdb-8372-F91955B62741}
Class notes (destination, redlined)
IEEE 421.5-2005 type ST7B model. This model is representative of static potential-source excitation systems. In this system, the AVR consists of a PI voltage regulator. A phase lead-lag filter in series allows the introduction of a derivative function, typically used with brushless excitation systems. In that case, the regulator is of the PID type. In addition, the terminal voltage channel includes a phase lead-lag filter. The AVR includes the appropriate inputs on its reference for overexcitation limiter (OEL1), underexcitation limiter (UEL), stator current limiter (SCL), and current compensator (DROOP). All these limitations, when they work at voltage reference level, keep the PSS (VS signal from PSS) in operation. However, the UEL limitation can also be transferred to the high value (HV) gate acting on the output signal. In addition, the output signal passes through a low value (LV) gate for a ceiling overexcitation limiter (OEL2). Reference: IEEE 421.5-2005, 7.7. According to IEEE 421.5-2016, 8.14 the ST7B excitation system model is being superseded by the model ST7C (ExcIEEEST7C).
▤Metadata
BaselineDestination
ParentPackageExcitationSystemDynamicsIEEE4215from2005
Class 'ExcIEEEST7B' has no other changes. The shows its notes and every changed property.
Added diagrams (1)
▶▦IEEE4215from2005i
Diagram notes
The diagram shows the excitation system models from IEEE 421.5-2005.
Diagram metadata — changes
BaselineDestination
AuthorChavdarIvanov
CreatedDate2021-01-02 08:50:53
DiagramTypeClassDiagram
ModifiedDate2022-03-18 22:35:21
NameIEEE4215from2005
PackageEAPK_D22779BB_015E_4250_9959_87234042A65F
ADDED{9FF804D7-2D35-41cd-8F7D-BD196AB7CE97}
Diagram notes
The diagram shows the excitation system models from IEEE 421.5-2005.
▤Metadata
BaselineDestination
AuthorChavdarIvanov
CreatedDate2021-01-02 08:50:53
DiagramTypeClassDiagram
ModifiedDate2022-03-18 22:35:21
NameIEEE4215from2005
PackageEAPK_D22779BB_015E_4250_9959_87234042A65F
▦Diagram
Baseline
Diagram did not exist in the baseline model.
Destination
IEEE4215from2005 (destination)
▶IEEE4215from2016i
Package notes
Excitation system models from IEEE 421.5-2016.
Package metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
IsLeaffalse
IsRootfalse
NameIEEE4215from2016
ParentPackageExcitationSystemDynamics
Phase1.0
Scopepublic
StatusProposed
TypePackage
Version1.0
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/IEEE4215from2016/1.0
version(no tag)1.0.0
ADDED{1E5D2248-C621-443e-98E0-864F168D2479}
Package notes
Excitation system models from IEEE 421.5-2016.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/IEEE4215from2016/1.0
version(no tag)1.0.0
Added classes (31)
▶⚙ExcIEEEAC10Ci
Class notes
IEEE 421.5-2016 AC10C excitation system model. It represents an excitation system with a brushless exciter, which is fed from an independent source or is supplied via the generator terminals. Reference: IEEE 421.5-2016, 7.19.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC10C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{D3BCA569-5804-44f3-8E22-8DABF8B55FFE}
Class notes
IEEE 421.5-2016 AC10C excitation system model. It represents an excitation system with a brushless exciter, which is fed from an independent source or is supplied via the generator terminals. Reference: IEEE 421.5-2016, 7.19.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC10C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kci{7A62544F-552C-4a61-8400-E1F975863A54}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,13.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,13.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{28AE2C7F-E7AB-4b39-87C2-8304753DED2C}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc2i{AAA477C2-66C6-45d4-8D8C-4172C49861F6}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kcri{18F1A8C6-0027-4e92-8EA3-214B3BFB7D4F}show detailsdid not existPU [0..1]Exciter field current regulator proportional gain (Kcr). Typical value = 0.
Attribute notes
Exciter field current regulator proportional gain (Kcr). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekcr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{4BFFFD03-3A98-4903-9F23-2D6977A214E0}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,15.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{0EEE5B6A-E4AD-4b55-9F2A-ED887A00C105}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kexci{952BC804-2DD4-428c-B939-72EF81A78EF1}show detailsdid not existPU [0..1]Exciter field current regulator feedback gain (Kexc). Typical value = 1.
Attribute notes
Exciter field current regulator feedback gain (Kexc). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekexc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{E30CDA41-8D9F-4b9b-A2E7-31053CFA001D}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki2i{B5C2269A-1859-4077-A5D2-CD8F7B82F8B3}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
klimi{0403F12A-2903-4110-B11C-8B014FC379A9}show detailsdid not existPU [0..1]Exciter field current limiter proportional gain (Klim). Typical value = 0.
Attribute notes
Exciter field current limiter proportional gain (Klim). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameklim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{5247FCA1-970C-4e54-9694-4C340D4AB73B}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kri{996A65A5-9F75-4c01-B92A-922638A4A32E}show detailsdid not existPU [0..1]Regulator gain (Kr). Typical value = 600.
Attribute notes
Regulator gain (Kr). Typical value = 600.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kvfei{BD5D4348-A21A-4321-A291-FBF3F223417E}show detailsdid not existPU [0..1]Exciter field current limiter feedback gain (Kvfe). Typical value = 1.
Attribute notes
Exciter field current limiter feedback gain (Kvfe). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekvfe
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{4B7B91C1-0324-4b28-ADAA-AD9BFF70117D}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{3ECC4FD5-2678-4fd6-A56D-E938CBC2A8BB}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{A066E5F7-26DF-4005-92BD-44990C8E93C4}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
swexci{A33C4F3F-B8D7-409f-AC14-CDFEB4AF0A22}show detailsdid not existBoolean [0..1]Exciter field current regulator feedback selector (SWexc). True mean position A. False means position B. Typical value = false.
Attribute notes
Exciter field current regulator feedback selector (SWexc). True mean position A. False means position B. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameswexc
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tb1i{E210F5F8-D9E5-4af3-86F6-4E331E6125D8}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant 1 (Tb1) (>=0). Typical value = 22,5.
Attribute notes
Voltage regulator denominator (lag) time constant 1 (Tb1) (>=0). Typical value = 22,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb2i{C499C4AC-B197-4683-8580-9707595B0BC4}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant 2 (Tb2) (>=0). Typical value = 0,13.
Attribute notes
Voltage regulator denominator (lag) time constant 2 (Tb2) (>=0). Typical value = 0,13.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc1i{0EE15E46-1177-4fbb-8D3E-B71AC9192773}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant 1 (Tc1) (>=0). Typical value = 3.
Attribute notes
Voltage regulator numerator (lead) time constant 1 (Tc1) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc2i{5094C985-67A1-4421-AC7A-73DEF51294C7}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant 2 (Tc2) (>=0). Typical value = 0,9.
Attribute notes
Voltage regulator numerator (lead) time constant 2 (Tc2) (>=0). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{E6400C72-0536-4a19-8794-02B6D8067345}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1,3.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
texci{5AE9E9FF-B763-4f04-A532-34B03E35E4E1}show detailsdid not existSeconds [0..1]Exciter field current regulator measurement time constant (Texc) (>=0). Typical value = 0.
Attribute notes
Exciter field current regulator measurement time constant (Texc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametexc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf1i{F7548DF0-1954-4e6d-9AD5-D26899A9E7C5}show detailsdid not existSeconds [0..1]Exciter field current regulator numerator (lead) time constant (Tf1) (>=0). Typical value = 0,1.
Attribute notes
Exciter field current regulator numerator (lead) time constant (Tf1) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf2i{6444E490-D59A-4205-B4D3-CD5C6A4233C8}show detailsdid not existSeconds [0..1]Exciter field current regulator denominator (lag) time constant (Tf2) (>=0). Typical value = 0,1.
Attribute notes
Exciter field current regulator denominator (lag) time constant (Tf2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{E95FA768-9A8A-4d50-A0BB-D797775EE408}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
tob1i{7EAEAEE6-B55B-483d-80A6-940F437ABF6C}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant 1 (Tob1) (>=0). Typical value = 18.
Attribute notes
OEL regulator denominator (lag) time constant 1 (Tob1) (>=0). Typical value = 18.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tob2i{4199E2C8-3933-462d-A515-1D15D7E4BAED}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant 2 (Tob2) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator denominator (lag) time constant 2 (Tob2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc1i{E314AA79-BD3B-48f5-B8D1-BD5E0F9734A5}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant 1 (Toc1) (>=0). Typical value = 0,9.
Attribute notes
OEL regulator numerator (lead) time constant 1 (Toc1) (>=0). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc2i{D161982E-BBEC-44ef-B696-DE380845C741}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant 2 (Toc2) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator numerator (lead) time constant 2 (Toc2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub1i{B3ACABE2-AEA1-463b-906B-D18E5FBDD8A9}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant 1 (Tub1) (>=0). Typical value = 22,5.
Attribute notes
UEL regulator denominator (lag) time constant 1 (Tub1) (>=0). Typical value = 22,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub2i{313329E8-5103-414e-A9B8-1BD3A9DD732E}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant 2 (Tub2) (>=0). Typical value = 0,13.
Attribute notes
UEL regulator denominator (lag) time constant 2 (Tub2) (>=0). Typical value = 0,13.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc1i{E9BAAD2F-399D-412e-822F-F4AE2EAB72D9}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant 1 (Tuc1) (>=0). Typical value = 3.
Attribute notes
UEL regulator numerator (lead) time constant 1 (Tuc1) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc2i{D6E87E16-6EFA-4004-BBB3-89277CF429F8}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant 2 (Tuc2) (>=0). Typical value = 0,9.
Attribute notes
UEL regulator numerator (lead) time constant 2 (Tuc2) (>=0). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vb1maxi{AFD82325-4EAF-4db3-8199-A48ACC37729A}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vb1max). Typical value = 1,5.
Attribute notes
Maximum available exciter field voltage (Vb1max). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb1max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vb2maxi{7BCFCD69-46D4-45c7-A395-29ED7155D97C}show detailsdid not existPU [0..1]Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute notes
Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb2max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{8ED89D8A-7714-4829-BCB9-61EC4EBB2CD8}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 10.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{C4D57112-5A1C-436d-ADA0-3F38FC5DB15C}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 7,5.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 7,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{B34B84E5-94F7-4082-98F9-C0733CC22962}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfelimi{07FF5DB8-832C-450c-BD4A-023948396712}show detailsdid not existPU [0..1]Exciter field current limiter reference (Vfelim). Typical value = 20.
Attribute notes
Exciter field current limiter reference (Vfelim). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfelim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{35E5AEF6-69A7-44c6-9DC9-A917BC92C9EF}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 44.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 44.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{DE85A950-DCE4-4765-91B4-906AA903F178}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute notes
Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{C249DC52-4841-4c7d-8768-8246BE3C1F7A}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 40.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 40.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{F1D7B8C2-78B0-4dfd-9B37-C7686576C757}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -35.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -35.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmaxi{D09FDC86-5AC9-42a8-A4F9-2DBC97A6C4EF}show detailsdid not existPU [0..1]Maximum PSS regulator output (Vrsmax). Typical value = 20.
Attribute notes
Maximum PSS regulator output (Vrsmax). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmini{8F4FCD48-E257-4f1d-9317-7987FD636588}show detailsdid not existPU [0..1]Minimum PSS regulator output (Vrsmin). Typical value = -20.
Attribute notes
Minimum PSS regulator output (Vrsmin). Typical value = -20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{DDBCB04F-D448-4258-8709-7A0CF0A07D29}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vsInputKindi{C6F0D4DA-44EF-4c75-9637-287F58850BE1}show detailsdid not existVsInputKind [0..1]Alternate PSS input locations (Vs).
Attribute notes
Alternate PSS input locations (Vs).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsInputKind
Scale0
Scopepublic
Staticfalse
TypeVsInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{6B8B004B-2BBA-485c-956C-1CF95F0D3F57}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{AAB36D96-C0D3-41ef-A513-23B4029ABC42}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC10C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC11Ci
Class notes
IEEE 421.5-2016 AC11C excitation system model. It is used to represent a brushless excitation system which is supplied from the generator’s terminals or from a power source independent of the generator (e.g., a permanent magnet generator or a power supply considered independent from the generator terminal conditions). Additionally, it offers a selection of compound circuits, which is added to the exciter field voltage. Reference: IEEE 421.5-2016, 7.20.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC11C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{5ABB944F-ACA2-49c0-AB72-3749605D99D5}
Class notes
IEEE 421.5-2016 AC11C excitation system model. It is used to represent a brushless excitation system which is supplied from the generator’s terminals or from a power source independent of the generator (e.g., a permanent magnet generator or a power supply considered independent from the generator terminal conditions). Additionally, it offers a selection of compound circuits, which is added to the exciter field voltage. Reference: IEEE 421.5-2016, 7.20.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC11C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kbi{169E27E1-EB3F-4f57-BC51-BDBA173528A1}show detailsdid not existPU [0..1]Voltage and UEL regulator derivative gain (Kb). Typical value = 3.
Attribute notes
Voltage and UEL regulator derivative gain (Kb). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kboosti{1C1AA2DF-88BE-444b-849B-EEB31C0B941F}show detailsdid not existPU [0..1]Additive independent source (Kboost). Typical value = 0.
Attribute notes
Additive independent source (Kboost). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekboost
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{5757E2AB-B12B-4194-A8CE-FD9DB3744D33}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,173.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,173.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{B1734577-6347-4b2b-BC77-2E5E9CAC1247}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc2i{64027414-50C8-449b-A8E4-7DBC7E38AB2D}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{0083F4C4-2FBB-4dbb-99BA-B455DE4FDF2C}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{29805942-CCFD-4eea-9580-5526B280E111}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{7062CC34-A81D-48dc-BD22-91ADD04C44CB}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki2i{8B894DFF-F13B-4c80-AD1B-BE1912DBC3F2}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{25AA6B7A-E6C4-44c8-A528-DB5BFF5D6F3B}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{52ADBB13-4EE5-451b-8F4D-99636AB86A69}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpa). Typical value = 30.
Attribute notes
Voltage regulator proportional gain (Kpa). Typical value = 30.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpoi{FF986A04-4246-4870-9B0F-C3D546BA0F66}show detailsdid not existPU [0..1]OEL regulator proportional gain (Kpo). Typical value = 30.
Attribute notes
OEL regulator proportional gain (Kpo). Typical value = 30.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpo
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpui{DF07112C-1067-4ea0-921C-B8F99FC32D40}show detailsdid not existPU [0..1]UEL regulator proportional gain (Kpu). Typical value = 30.
Attribute notes
UEL regulator proportional gain (Kpu). Typical value = 30.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpu
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{35B3A487-82DA-4342-9CB9-87F381C8788C}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{4405CB3C-D6E7-4c7a-A1A0-FECF2E64CBD6}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{F132E171-632E-4528-8DA9-FE1BE729C61D}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{B4D35EF9-36B3-43ef-BB75-30B1BC48C2D4}show detailsdid not existSeconds [0..1]Time constant for derivative element (Tb) (>=0). Typical value = 0,4.
Attribute notes
Time constant for derivative element (Tb) (>=0). Typical value = 0,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{51DFBFB6-E020-4b5c-8C06-2FB4BD4365A1}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,4.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tiai{16CF2E36-411B-470b-95C7-68D83C9FE789}show detailsdid not existSeconds [0..1]Voltage regulator integral time constant (Tia) (>=0). Typical value = 2.
Attribute notes
Voltage regulator integral time constant (Tia) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametia
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tioi{81DA35A0-D636-47e3-B84A-A8AF9A69B1E0}show detailsdid not existSeconds [0..1]OEL regulator integral time constant (Tio) (>=0). Typical value = 2.
Attribute notes
OEL regulator integral time constant (Tio) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametio
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{0B574F7C-826F-40c3-BF47-90C32CED3029}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
tiui{54944605-3912-406e-8495-6BCF82F56AD4}show detailsdid not existSeconds [0..1]UEL regulator integral time constant (Tiu) (>=0). Typical value = 2.
Attribute notes
UEL regulator integral time constant (Tiu) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametiu
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{E2DB8E92-CBF0-46a4-88D2-CEB4AF801509}show detailsdid not existPU [0..1]Maximum exciter output (Vamax). Typical value = 20.
Attribute notes
Maximum exciter output (Vamax). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{0B60DAD0-B313-4a71-B9BE-4353A43FC8F6}show detailsdid not existPU [0..1]Minimum exciter output (Vamin). Typical value = 0.
Attribute notes
Minimum exciter output (Vamin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vb1maxi{79C740AE-DF20-472b-BEF1-4D4656C8D0AB}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vb1max). Typical value = 1,5.
Attribute notes
Maximum available exciter field voltage (Vb1max). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb1max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vb2maxi{96E7D1A1-A6E5-43d6-9B09-D1D697DE321B}show detailsdid not existPU [0..1]Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute notes
Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb2max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vboosti{802C4E4A-27B8-41e7-9035-4A4A8097DBFE}show detailsdid not existPU [0..1]Reference value for applying additive (boost) circuit (Vboost). Typical value = 0.
Attribute notes
Reference value for applying additive (boost) circuit (Vboost). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevboost
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{0D4C00F5-6E72-47b2-9CF4-FFE51FDFA2FD}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 7,4.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 7,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{342C1648-5CF0-42c9-8D40-20D6DA3AD362}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 5,55.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 5,55.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{5D43E76F-62ED-4ca3-95E8-406F516E9465}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{8BB35E33-446B-482e-B581-1DC7B5BA55FA}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 20.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{1E695A89-85A9-4226-8ECF-EB6D2691A64D}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute notes
Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{ACE34922-1167-4b31-AAAD-6F436A85281F}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 20.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{96019E1B-D9F2-4072-9F1B-134BEE046686}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -20.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmaxi{F8D65B58-3BC0-4edc-BA00-8475EC9A8059}show detailsdid not existPU [0..1]Maximum PSS regulator output (Vrsmax). Typical value = 3.
Attribute notes
Maximum PSS regulator output (Vrsmax). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmini{AFB74EA8-2F46-470a-9A4F-2D6C90433EAF}show detailsdid not existPU [0..1]Minimum PSS regulator output (Vrsmin). Typical value = -3.
Attribute notes
Minimum PSS regulator output (Vrsmin). Typical value = -3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{2A451298-3942-43f7-9206-C305A22BFE17}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vsInputKindi{8765FC46-67D1-4974-9783-B8D0E44D12F4}show detailsdid not existVsInputKind [0..1]Alternate PSS input locations (Vs).
Attribute notes
Alternate PSS input locations (Vs).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsInputKind
Scale0
Scopepublic
Staticfalse
TypeVsInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{F8722246-5DCB-4e89-A260-A7C87063D99C}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{F13AF326-F8D4-4bfa-A56F-4B75F46F91F7}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC11C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC1Ci
Class notes
IEEE 421.5-2016 AC1C excitation system model. It consists of an alternator main exciter feeding its output via non-controlled rectifiers. The exciter does not employ self-excitation, and the voltage regulator power is taken from a source that is not affected by external transients. Reference: IEEE 421.5-2016, 7.3.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{D8E1B324-FCBF-4423-8449-49BF037AF7B6}
Class notes
IEEE 421.5-2016 AC1C excitation system model. It consists of an alternator main exciter feeding its output via non-controlled rectifiers. The exciter does not employ self-excitation, and the voltage regulator power is taken from a source that is not affected by external transients. Reference: IEEE 421.5-2016, 7.3.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
efemaxi{D14460D3-184F-4572-9CEF-CE0F8ECACBF6}show detailsdid not existPU [0..1]Maximum exciter field voltage (Efemax). Typical value = 6,3.
Attribute notes
Maximum exciter field voltage (Efemax). Typical value = 6,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efemini{AACF09D9-C640-4cac-9217-7D59126A44C8}show detailsdid not existPU [0..1]Minimum exciter field voltage (Efemin). Typical value = -5,43.
Attribute notes
Minimum exciter field voltage (Efemin). Typical value = -5,43.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{E5082D68-90ED-48e5-8DAC-6D9DA53412CF}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 400.
Attribute notes
Regulator output gain (Ka). Typical value = 400.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{C40664B2-9E25-45a0-99EC-F39E2D9B9446}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{4B27F5C1-73D1-470c-8A3A-078FEF215AAA}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,38.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,38.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{4C5F5CB1-B158-4945-B218-E51C53E313A6}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{75721722-6EA8-458a-AE72-5E611036F585}show detailsdid not existPU [0..1]Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute notes
Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{A7FF2809-5511-4ffa-9B30-72DDB99E7A04}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,1.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{2D0537C4-3723-409e-960F-2D6E7902120B}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,03.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{C6FFF68F-6B08-4f7a-81CC-7745EC0C3743}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,02.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{130023C7-8309-4bcd-9FCA-0A11DDABFA82}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{39AABB12-F366-48f6-8F07-A8BCF55E06CD}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{2542F66E-4F76-4651-BFE2-D6C4F14CEC52}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{90322733-02A2-4c19-9A44-368AD5A31BDF}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{68C93741-217E-499f-9F21-24DC1B8613A1}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 14,5.
Attribute notes
Maximum regulator output (Vamax). Typical value = 14,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{96729FED-53A2-4df4-AAC0-C7A63066F287}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -14,5.
Attribute notes
Minimum regulator output (Vamin). Typical value = -14,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{0F840C81-867C-4467-97EF-CE836ED6A1A6}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,18.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,18.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{F8083A3D-CD93-4268-BEDD-29C32084961C}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,14.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,14.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{A9F3DE2B-B2F0-4d85-8AE9-D7446BB13B9D}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{FD6D8FFC-B184-4148-87BD-3BF65947E893}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 99.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{758028E8-8AE1-4ad2-8568-6F6556708696}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{0BA024E5-3B88-44d6-9E52-71CBFB521CD7}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{5A95241D-54E5-409c-80EF-037659F8DEBC}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC2Ci
Class notes
IEEE 421.5-2016 AC2C excitation system model. It represents a high initial response field controlled alternator-rectifier excitation system. The alternator main exciter is used, feeding its output via non-controlled rectifiers. Reference: IEEE 421.5-2016, 7.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{777943BE-85C8-46aa-B334-96B39A1EEE48}
Class notes
IEEE 421.5-2016 AC2C excitation system model. It represents a high initial response field controlled alternator-rectifier excitation system. The alternator main exciter is used, feeding its output via non-controlled rectifiers. Reference: IEEE 421.5-2016, 7.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
efemaxi{83D58BA8-FF4F-49a5-B5DD-20A3358F162A}show detailsdid not existPU [0..1]Maximum exciter field voltage (Efemax). Typical value = 105.
Attribute notes
Maximum exciter field voltage (Efemax). Typical value = 105.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efemini{F3FD6FDC-3DC2-4fde-841B-71AFD75A4EF6}show detailsdid not existPU [0..1]Minimum exciter field voltage (Efemin). Typical value = -95.
Attribute notes
Minimum exciter field voltage (Efemin). Typical value = -95.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{DDEE80D1-20AA-40f4-859F-0948ABB61D19}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 400.
Attribute notes
Regulator output gain (Ka). Typical value = 400.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kbi{4BE5A568-B150-49c9-AC9B-288B366E7296}show detailsdid not existPU [0..1]Second stage regulator gain (Kb). Typical value = 25.
Attribute notes
Second stage regulator gain (Kb). Typical value = 25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{6B27FADF-2029-4b76-805C-9FE13AF491FE}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,28.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,28.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{CF85B43E-6C02-4dff-95F7-0F88A9398059}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,35.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,35.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{5D1DC5C9-7719-457f-A367-31762063E7C6}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{E7A5C3E1-4CC1-44d2-884D-FA2726594360}show detailsdid not existPU [0..1]Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute notes
Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
khi{283286FA-DF52-4729-849C-3DE96AE67921}show detailsdid not existPU [0..1]Exciter field current regulator feedback gain (Kh). Typical value = 1.
Attribute notes
Exciter field current regulator feedback gain (Kh). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekh
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{0603C288-779B-4fa7-A55E-E7AAD4335EA8}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,037.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,037.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{367E50FA-3DDF-45e4-85D8-F3224D771F1B}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,012.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,012.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{EBA5A136-5EDC-4341-A439-73A047A12B7A}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,01.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{109A2821-9D74-4bb4-B191-DC7F4C82CBE9}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{4A8E658D-159D-402b-9E60-E4B15083D3C7}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{3B9CC675-10B7-493a-8FDC-FE066EFC67D5}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,6.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{04684B79-05F0-40b1-BD0B-174E80D4A286}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{90D6DAAD-A9AC-4f91-9665-4A2989BDF7E4}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 8.
Attribute notes
Maximum regulator output (Vamax). Typical value = 8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{370E321E-EAF9-4012-A438-918CC62A027D}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -8.
Attribute notes
Minimum regulator output (Vamin). Typical value = -8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{572FB83C-D588-49c9-BD68-B8F9F7974BA1}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,4.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{172E7DEC-9CEF-4b92-9505-F587D196F568}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,3.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{4FD60A58-3890-400a-B399-80E90B1BA816}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{92169320-5012-4109-8401-F1D56836370E}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 4,4.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 4,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{AD2646DA-E584-4a34-BC61-1E78FA3676C2}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{E4661EF8-3590-402a-AD96-94B370ACCB13}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{D952E582-26B4-44cb-B5A0-83775F15489C}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC3Ci
Class notes
IEEE 421.5-2016 AC3C excitation system model. It represents represents the field-controlled alternator-rectifier excitation systems which includes an alternator main exciter feeding its output via non-controlled rectifiers. The exciter employs self-excitation and the voltage regulator power is derived from the exciter output voltage. Reference: IEEE 421.5-2016, 7.7.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC3C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1B72EEF9-938C-48e8-91D3-81F07C4E61F8}
Class notes
IEEE 421.5-2016 AC3C excitation system model. It represents represents the field-controlled alternator-rectifier excitation systems which includes an alternator main exciter feeding its output via non-controlled rectifiers. The exciter employs self-excitation and the voltage regulator power is derived from the exciter output voltage. Reference: IEEE 421.5-2016, 7.7.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC3C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
efdni{611562F8-8DB4-4ce7-AD58-FE6FBFD34CBD}show detailsdid not existPU [0..1]Value of EFD at which feedback gain changes (Efdn). Typical value = 2,36.
Attribute notes
Value of EFD at which feedback gain changes (Efdn). Typical value = 2,36.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefdn
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{65710A75-1EF9-49e0-816E-A67EB625EDCD}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 45,62.
Attribute notes
Regulator output gain (Ka). Typical value = 45,62.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{9D96BE6E-D01F-4f8c-B72E-0F5BA44F7F26}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,104.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,104.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{7FDC8F0E-94BF-45cd-9FE9-F219710E7FB2}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,499.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,499.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdri{A4E7A5DE-5697-404e-8FE1-D1C0245E9658}show detailsdid not existPU [0..1]Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute notes
Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{D0672A16-E139-4550-B14C-A4C78031E423}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{7AD39ADE-A4BA-4781-97DE-092AC621444C}show detailsdid not existPU [0..1]Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,143.
Attribute notes
Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,143.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{4987FE23-329F-4bb4-A149-CBC70BD0EAD0}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir). Typical value = 0.
Attribute notes
Voltage regulator integral gain (Kir). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kni{D8EA8B0F-AA6B-477c-AB73-A7DABD9E7E19}show detailsdid not existPU [0..1]Rate feedback excitation system stabilizer gain (Kn). Typical value = 0,05.
Attribute notes
Rate feedback excitation system stabilizer gain (Kn). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekn
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{C2CACE09-68DB-42bd-879D-A2C6D5ED6FB1}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr). Typical value = 1.
Attribute notes
Voltage regulator proportional gain (Kpr). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kri{8566D065-4EB9-42ef-899F-DAB1284298A3}show detailsdid not existPU [0..1]Gain associated with regulator and alternator field power supply (Kr). Typical value = 3,77.
Attribute notes
Gain associated with regulator and alternator field power supply (Kr). Typical value = 3,77.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{55A3C508-12A9-4faa-97DB-132917674405}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 1,143.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 1,143.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{B55B2056-6DDE-4eb7-9A7D-42179BE96B76}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,1.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{0C810B15-2B91-4704-AB0F-D31A4DBB9124}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,013.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,013.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{C5EF16F5-2CB8-414e-B906-FBE5AAF1736E}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{FAE124E1-6437-44df-A4C8-FA8937028532}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdri{D0DC58B0-75B6-4f5e-9D41-2F46884AD7DE}show detailsdid not existSeconds [0..1]Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 1.
Attribute notes
Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{0FFAB728-88BE-4103-B0CA-00583AF936CC}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1,17.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1,17.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{BEBC0252-2B58-4665-8A53-0EA7C830F41C}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{2D5A32B8-503C-4185-8D9A-6C71AD99D17D}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 1.
Attribute notes
Maximum regulator output (Vamax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{B522D3B4-45E4-42e5-95C4-33244FE83BC8}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -0,95.
Attribute notes
Minimum regulator output (Vamin). Typical value = -0,95.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{168EAFAF-C292-477f-81FC-C93E4881C770}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 6,24.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 6,24.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{EB090C90-5682-4c05-BC00-54AC9CC04D16}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 4,68.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 4,68.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{FE2363D0-4221-4ea0-A6C3-A80111A4E835}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0,1.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{717EEF4C-5F10-49ff-9C8F-1BBD23672558}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 16.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{EABC1D86-ADDA-454e-872C-BC73EC4B18BA}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmaxi{62D88F78-FBEA-4b47-94A9-0403E046D617}show detailsdid not existPU [0..1]Maximum PID regulator output (Vpidmax). Typical value = 3,2.
Attribute notes
Maximum PID regulator output (Vpidmax). Typical value = 3,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmini{3623A205-86F4-455e-A714-E1CD27628EB9}show detailsdid not existPU [0..1]Minimum PID regulator output (Vpidmax). Typical value = -3,2.
Attribute notes
Minimum PID regulator output (Vpidmax). Typical value = -3,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{0C5304CF-9098-4a3c-AC8A-F0C088E06831}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{CD489183-045F-4124-93BA-380164490C47}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC4Ci
Class notes
IEEE 421.5-2016 AC4C excitation system model. It is alternator supplied controlled rectifier excitation system. It is a initial response excitation system which utilizes a full thyristor bridge in the exciter output circuit. Reference: IEEE 421.5-2016, 7.9.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{D8BC25D6-66B1-43d2-BBEB-861B2F9D443E}
Class notes
IEEE 421.5-2016 AC4C excitation system model. It is alternator supplied controlled rectifier excitation system. It is a initial response excitation system which utilizes a full thyristor bridge in the exciter output circuit. Reference: IEEE 421.5-2016, 7.9.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{83A0073B-E256-4c4e-97F8-31FC1F516E74}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 200.
Attribute notes
Regulator output gain (Ka). Typical value = 200.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{CDD999B3-6AB0-47cf-A5F5-8CB7912602B0}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{4D8A6FA6-4E2A-4cbd-9855-70F65DD9520B}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,015.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,015.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{E016FD92-BC69-46c5-B513-29E4C64D8B41}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 10.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{BD2EFB7E-E106-4753-96DD-58B7492BB662}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vimaxi{A73B315E-7B3A-44f3-BCDC-49F59B17DF09}show detailsdid not existPU [0..1]Voltage regulator input (voltage error) maximum limit (Vimax). Typical value = 10.
Attribute notes
Voltage regulator input (voltage error) maximum limit (Vimax). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vimini{3C31FFF8-8A77-4986-98EB-0CE80E80DD4F}show detailsdid not existPU [0..1]Voltage regulator input (voltage error) minimum limit (Vimin). Typical value = -10.
Attribute notes
Voltage regulator input (voltage error) minimum limit (Vimin). Typical value = -10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{60221CD0-BB73-45ea-9189-93A2F0BA4B5C}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{16CF0956-3DAF-4622-81D6-85BA3383D21D}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 5,64.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 5,64.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{5BA996F7-E7DD-4ee3-BBD5-98589DB9B271}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -4,53.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -4,53.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{5DE4A4E2-1BBD-4e2f-AECA-3CB913F040C7}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{7098676D-FE36-4455-BDA5-FCAAAA0068E3}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC5Ci
Class notes
IEEE 421.5-2016 AC5C excitation system model. It is a simplified model for brushless excitation systems. The regulator is supplied from a source, such as a permanent magnet generator, which is not affected by system disturbances. Reference: IEEE 421.5-2016, 7.11.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC5C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0EB855B7-7A75-4ad5-BCA7-5CA458B95CC9}
Class notes
IEEE 421.5-2016 AC5C excitation system model. It is a simplified model for brushless excitation systems. The regulator is supplied from a source, such as a permanent magnet generator, which is not affected by system disturbances. Reference: IEEE 421.5-2016, 7.11.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC5C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{B355BAE4-2E36-4a78-BE7D-513D3B6722BB}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 400.
Attribute notes
Regulator output gain (Ka). Typical value = 400.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{96E9BD69-7E2C-4bde-BA99-0DD04C6DD271}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{8291322D-2CFF-49bd-B78D-757E9B147848}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,38.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 0,38.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{D730FB2B-66FA-433d-81E7-AAA6FD3B4813}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{6CF1BA9C-8299-49ae-A9FC-516F43ADE2D8}show detailsdid not existPU [0..1]Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute notes
Rate feedback excitation system stabilizer gain (Kf). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{FD5E1A86-7A0B-41ce-9F95-F2EDCD1732DE}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,86.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,86.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{84ABBE09-58FE-4078-8E6E-03CE189DE8DC}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,5.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{41D86866-B1F1-46f3-9D14-76C22F11F509}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,02.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{287D0D35-77C3-4d77-875B-9347B0C8D71E}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf1i{53FE3EE5-B99C-4109-96CD-B7E3A4180E8C}show detailsdid not existSeconds [0..1]Rate feedback excitation system stabilizer time constant (Tf1) (>=0). Typical value = 1.
Attribute notes
Rate feedback excitation system stabilizer time constant (Tf1) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf2i{DD8A68C5-C0A2-40a7-A11C-E6C0A2A3A0EF}show detailsdid not existSeconds [0..1]Rate feedback excitation system stabilizer time constant (Tf2) (>=0). Typical value = 0.
Attribute notes
Rate feedback excitation system stabilizer time constant (Tf2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf3i{740A7A47-9960-4bd2-9F10-97C1D3F068A3}show detailsdid not existSeconds [0..1]Rate feedback excitation system stabilizer time constant (Tf3) (>=0). Typical value = 0.
Attribute notes
Rate feedback excitation system stabilizer time constant (Tf3) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{CAE82C5B-8CB4-4c2f-A53F-29402B7AA31D}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 7,3.
Attribute notes
Maximum regulator output (Vamax). Typical value = 7,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{1FB0459D-3D7C-4781-AFB4-7D256F6FFE5B}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -7,3.
Attribute notes
Minimum regulator output (Vamin). Typical value = -7,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{874D80CB-F2AA-498e-8A3F-473F57D96E48}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 5,6.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 5,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{739F43DC-5680-401f-A55D-12F8B937588F}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 4,2.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 4,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{41963D74-4463-44b0-A0BA-B122E0CD5361}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{ECE83669-C2BB-4872-89C7-549B02F0A69D}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 99.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{CACB812D-C500-4a98-974D-0F55415A4FF3}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{EFA7C31F-12C1-4883-BA05-839530937207}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{742C8006-AC16-4ef0-B004-2D54B2775644}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC6Ci
Class notes
IEEE 421.5-2016 AC6C excitation system model. It represents field-controlled alternator-rectifier excitation systems with system-supplied electronic voltage regulators. Reference: IEEE 421.5-2016, 7.13.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC6C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1BD5A53B-7BA9-42ba-BA2C-8771E5626059}
Class notes
IEEE 421.5-2016 AC6C excitation system model. It represents field-controlled alternator-rectifier excitation systems with system-supplied electronic voltage regulators. Reference: IEEE 421.5-2016, 7.13.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC6C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
efemaxi{19BF3BA8-2E1F-48ca-A2CE-9816EDAC1233}show detailsdid not existPU [0..1]Maximum exciter field voltage (Efemax). Typical value = 44.
Attribute notes
Maximum exciter field voltage (Efemax). Typical value = 44.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efemini{72684DA3-91F8-47c0-90FD-507344BE83D3}show detailsdid not existPU [0..1]Minimum exciter field voltage (Efemin). Typical value = -36.
Attribute notes
Minimum exciter field voltage (Efemin). Typical value = -36.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{07F3F1FB-E87D-470a-B2E3-FD4A229F2E2C}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 536.
Attribute notes
Regulator output gain (Ka). Typical value = 536.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{E6062327-0766-4ba5-AE98-3EB6E9027D7D}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,173.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,173.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{35AB849D-1084-402c-A17D-C43AEE4CC68B}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,91.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,91.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{71F1D977-F1ED-4799-96AF-C9338E74ADB5}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1,6.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
khi{FF93007F-18AC-40c9-8FE5-9791915B29CC}show detailsdid not existPU [0..1]Exciter field current limiter gain (Kh). Typical value = 92.
Attribute notes
Exciter field current limiter gain (Kh). Typical value = 92.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekh
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{3F842132-2A90-4fd0-9718-45662412BC8B}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,214.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{B4509E67-3B42-4a45-9F24-343B5F1B2D43}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,044.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{998BD1FB-88A9-42f8-8367-4FE3693B2344}show detailsdid not existSeconds [0..1]Regulator output time constant (Ta) (>=0). Typical value = 0,086.
Attribute notes
Regulator output time constant (Ta) (>=0). Typical value = 0,086.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{A75BEB2A-22F1-4ced-80C4-DDEC31833303}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 9.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{F320E40D-D766-4102-AC1D-08FFCD1535DD}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 3.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{947895BD-5DBD-47ac-A809-18882AC45A71}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
thi{5E543C57-9A4E-4607-B30F-0BFFEA043E5A}show detailsdid not existSeconds [0..1]Exciter field current limiter denominator (lag) time constant (Th) (>=0). Typical value = 0,08.
Attribute notes
Exciter field current limiter denominator (lag) time constant (Th) (>=0). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameth
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tji{AC88FAE4-F276-4cc8-A29B-8586B21CAE87}show detailsdid not existSeconds [0..1]Exciter field current limiter numerator (lead) time constant (Tj) (>=0). Typical value = 0,02.
Attribute notes
Exciter field current limiter numerator (lead) time constant (Tj) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametj
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tki{2983D016-2DE3-4858-9899-56D2A46F0EAD}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tk) (>=0). Typical value = 0,18.
Attribute notes
Regulator numerator (lead) time constant (Tk) (>=0). Typical value = 0,18.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametk
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{6A33F094-83F3-4a28-8617-D93E25B3F879}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 75.
Attribute notes
Maximum regulator output (Vamax). Typical value = 75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{ECB08C5E-F930-400d-8E5F-7957E47E6B37}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -75.
Attribute notes
Minimum regulator output (Vamin). Typical value = -75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{78DFFD23-DFDA-4dd0-8F68-895D7E055617}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 7,4.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 7,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{8FC82A1B-2CCC-469a-B381-A63167A74A8A}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 5,55.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 5,55.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{B59B0B45-6025-4b96-8A6A-162B81A57C0E}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfelimi{4780041E-8394-4a02-8010-A4D9CF19B377}show detailsdid not existPU [0..1]Exciter field current limiter reference (Vfelim). Typical value = 19.
Attribute notes
Exciter field current limiter reference (Vfelim). Typical value = 19.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfelim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{52623598-6CD9-4ec3-A12D-8F26D6A94E5F}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 999.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 999.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vhmaxi{6B16CABD-3A1B-47cc-B92C-A5E979B8B916}show detailsdid not existPU [0..1]Exciter field current limiter maximum output (Vhmax). Typical value = 75.
Attribute notes
Exciter field current limiter maximum output (Vhmax). Typical value = 75.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevhmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{EDDF1101-C467-4fb0-B99D-440A0523A485}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{81F14F80-7597-45b3-BA52-9BFDE9281444}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{97008E3A-4C63-47a6-8A9A-8EC345214B8E}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC6C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC7Ci
Class notes
IEEE 421.5-2016 AC7C excitation system model. It consists of an AC alternator with either stationary or rotating rectifiers to produce the DC field requirements. Reference: IEEE 421.5-2016, 7.15.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC7C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{E25F5BB9-E15C-414f-8DA7-8837757638F1}
Class notes
IEEE 421.5-2016 AC7C excitation system model. It consists of an AC alternator with either stationary or rotating rectifiers to produce the DC field requirements. Reference: IEEE 421.5-2016, 7.15.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC7C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kci{DF151317-4BBF-4542-B3C2-6818EB699A9F}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,12.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,12.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{3094A066-23F8-4cbf-80AF-C3162C1275E1}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{A053BBCB-6FE8-4599-ABB1-113E6F164CCB}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 3,3.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 3,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdri{D3C865D6-CB03-48d9-92A3-AFF7F4178757}show detailsdid not existPU [0..1]Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute notes
Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{E1D83A92-B039-45b8-90E3-765D4C18A4CC}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kf1i{439714A6-3A98-4c70-9210-09063330F460}show detailsdid not existPU [0..1]Generator field voltage feedback gain (Kf1). Typical value = 0.
Attribute notes
Generator field voltage feedback gain (Kf1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kf2i{8120B400-3E7E-433b-A1B7-DA4B0EDFCAD9}show detailsdid not existPU [0..1]Exciter field current feedback gain (Kf2). Typical value = 0,08.
Attribute notes
Exciter field current feedback gain (Kf2). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kf3i{A94427EA-85F7-4222-8441-E51F9202E6A0}show detailsdid not existPU [0..1]Rate feedback gain (Kf3). Typical value = 0,01.
Attribute notes
Rate feedback gain (Kf3). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{C1BE855A-5D5A-4eb3-9667-2003DD811113}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{FFB98DB7-0CED-4c14-88B3-371429BB217C}show detailsdid not existPU [0..1]Field current regulator integral gain (Kia). Typical value = 0.
Attribute notes
Field current regulator integral gain (Kia). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{C562556E-6936-4e1b-A92D-BF1802E27994}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir). Typical value = 5,6.
Attribute notes
Voltage regulator integral gain (Kir). Typical value = 5,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kli{C730E5D9-9E3D-4c85-90E9-95CB71E7A3E4}show detailsdid not existPU [0..1]Gain related to negative exciter field current capability (Kl). Typical value = 0.
Attribute notes
Gain related to negative exciter field current capability (Kl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{DF560E58-E769-44f2-8E52-90311BE20E88}show detailsdid not existPU [0..1]Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{48080061-DCDD-48cf-A046-F6BA929CE080}show detailsdid not existPU [0..1]Field current regulator proportional gain (Kpa). Typical value = 112.
Attribute notes
Field current regulator proportional gain (Kpa). Typical value = 112.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{674B6E68-2CA1-4339-9169-822DD0FFAAFA}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr). Typical value = 40.
Attribute notes
Voltage regulator proportional gain (Kpr). Typical value = 40.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kri{81F49292-A5E5-468a-8096-13012920786B}show detailsdid not existPU [0..1]Gain related to regulator and alternator field power supply (Kr). Typical value = 0.
Attribute notes
Gain related to regulator and alternator field power supply (Kr). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{10B69023-5E51-4afb-BB01-D0470AC86B8E}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 3,74.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 3,74.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{E2E44418-6290-4639-99BB-4DDEB7D33FCB}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,32.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,32.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{5DC6ACC6-D765-410e-B035-D3B7E9375624}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
sw2i{C22095BB-D61D-4cc6-BC05-83F29B713D39}show detailsdid not existBoolean [0..1]Power source selector (SW2). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW2). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw2
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tdri{5F5DA0DC-45BA-4376-AEEE-C0746891C9FE}show detailsdid not existSeconds [0..1]Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 1.
Attribute notes
Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{F78730C2-6E42-4a65-A7A6-B1A115296415}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1,2.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{7171DBC9-B10D-4c06-9910-3A073245CF4E}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{463D3527-1A53-401e-8162-2EA0AEA1DB00}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{8100D681-D522-47ab-8641-550C2B7EB5F0}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 65,2.
Attribute notes
Maximum regulator output (Vamax). Typical value = 65,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{31C40C2C-5966-40a7-ABC7-47D2BEBEE96B}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -54.
Attribute notes
Minimum regulator output (Vamin). Typical value = -54.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{5A81EED6-803A-4de5-99A5-A5DEEF2E7FBA}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vbmax). Typical value = 999.
Attribute notes
Maximum available exciter field voltage (Vbmax). Typical value = 999.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{4E7583B3-0119-497e-BEEE-0D057838954B}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 13,6.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 13,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{A719B4C5-023E-4e71-ABAC-E9E1EA9DBF2C}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 10,2.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 10,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{C7F8AB33-60DC-4243-806D-847D2E3DC84A}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{899D6BD3-AC48-428a-8F29-9A8B9A5BBB19}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 23,2.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 23,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{0F791599-1926-4ef7-9D31-C54AEFA05B51}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel).
Attribute notes
Alternate OEL input locations (Voel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{8BCEFCE9-B26E-4fc5-9E93-45027359D360}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 3,2.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 3,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{ED874231-D727-4176-A6EE-D665B69DF991}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -3,2.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -3,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi{C9EAA0BD-AD93-485a-BE73-943F2D496D80}show detailsdid not existBoolean [0..1]Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input after take-over UEL.
Attribute notes
Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input after take-over UEL.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevs
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{8F3B5A52-DEEA-460e-A031-EB3E73975F97}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{1C52473A-C804-4a0e-B68B-C4FC312C9446}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{3D9978DD-7DD1-4524-B788-E008CC1A2266}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC7C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC8Ci
Class notes
IEEE 421.5-2016 AC8C excitation system model. It consists of PID control, with separate constants for the proportional, integral and derivative gains. It can be used to represent static voltage regulators applied to brushless excitation systems. Reference: IEEE 421.5-2016, 7.17.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC8C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{EC22D46E-C68E-4423-A883-6DFE0C9C16A6}
Class notes
IEEE 421.5-2016 AC8C excitation system model. It consists of PID control, with separate constants for the proportional, integral and derivative gains. It can be used to represent static voltage regulators applied to brushless excitation systems. Reference: IEEE 421.5-2016, 7.17.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC8C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{90D6F105-C8A1-4b11-AD00-A3D118A201D5}show detailsdid not existPU [0..1]Rectifier bridge gain (Ka). Typical value = 1.
Attribute notes
Rectifier bridge gain (Ka). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{61886093-6723-4634-A43F-B319A1ADC25E}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,55.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,55.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{3636CEC2-B355-4db3-A3C1-921A086C556C}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{120837DE-2923-445c-923E-92D1478EEB18}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,1.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdri{D44BF2E8-7F8E-48c9-8E35-B75936706FF5}show detailsdid not existPU [0..1]Voltage regulator derivative gain (Kdr). Typical value = 10.
Attribute notes
Voltage regulator derivative gain (Kdr). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{81F1FDF4-F8C4-41ab-BDE8-2BC75D3309CF}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{0D6639D1-0C39-4b47-B808-DF21466CC037}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{AE1D4E19-BA74-40aa-A47B-2C4A3DB4DDC2}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir). Typical value = 5.
Attribute notes
Voltage regulator integral gain (Kir). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{D414853A-3342-4488-A75A-9238B1B5FAF2}show detailsdid not existPU [0..1]Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{68CD0475-BF01-486f-95D2-CB42A7DD2F2D}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr). Typical value = 80.
Attribute notes
Voltage regulator proportional gain (Kpr). Typical value = 80.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{C9B5CCA9-2F46-4ed5-9A37-BC2ACE6F3C3F}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 3.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{05C9E293-9A56-45a5-98B7-927659D03F3E}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,3.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{3606E2E9-5ACB-46a0-8A51-E29167149374}show detailsdid not existBoolean [0..1]Logical switch 1 (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Logical switch 1 (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{81064954-7875-4f56-829E-AF9F42A07197}show detailsdid not existSeconds [0..1]Rectifier bridge time constant (Ta) (>=0). Typical value = 0,01.
Attribute notes
Rectifier bridge time constant (Ta) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdri{4A1FF017-6ABE-427b-B4D7-B51385B2A2DE}show detailsdid not existSeconds [0..1]Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 0,02.
Attribute notes
Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{76D0BC0A-2676-4316-8722-E2F11312EFF1}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1,2.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{E5065C84-5063-46fc-A9E9-14D344850D0E}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{2C2B33E1-6404-4d89-97C3-0BF71B5482D8}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vbmax). Typical value = 1,25.
Attribute notes
Maximum available exciter field voltage (Vbmax). Typical value = 1,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{2CC81F84-A945-442d-86D4-2F24D0026B0B}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 9.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{7D1BD255-234C-4f9b-9415-D464EE431DDD}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 6,5.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 6,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{56720099-8311-4b96-AF5F-05DD93F662A1}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{DF484341-8E7A-495c-BBC2-2031BAEB7EE6}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 6.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{0F6B4B15-DC21-46ab-8B21-B6F5A0ED98E8}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute notes
Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmaxi{807A4B47-8F0C-4745-BBD3-A5AE5E19D28F}show detailsdid not existPU [0..1]Maximum PID regulator output (Vpidmax).
Attribute notes
Maximum PID regulator output (Vpidmax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmini{F095F1E7-0F7C-4034-92BF-445CFCB169DF}show detailsdid not existPU [0..1]Minimum PID regulator output (Vpidmax).
Attribute notes
Minimum PID regulator output (Vpidmax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{FFECD63E-64FB-4714-9C81-2510154B852E}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 35.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 35.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{80DB9E5D-8F5D-4b92-BBAA-4CA38ED532F2}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = 0.
Attribute notes
Minimum regulator output (Vrmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi{D499D1B6-70F7-45c5-A4C3-04B6797D3E90}show detailsdid not existBoolean [0..1]Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input after take-over UEL.
Attribute notes
Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input after take-over UEL.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevs
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{D67A62C3-3BB9-4b21-9C45-D9275250B67C}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{9C863845-E7C6-44c3-BFD8-A9F9AFC02DF0}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{88CF4ED3-0EC0-4458-B922-587DBDBFAABC}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC8C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEAC9Ci
Class notes
IEEE 421.5-2016 AC9C excitation system model. It may be applied to excitation systems consisting of an ac alternator with either stationary or rotating rectifiers. The model consists of a PID type voltage regulator followed by a PI current regulator in cascade. Reference: IEEE 421.5-2016, 7.18.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC9C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{3A8CFD09-B265-4307-BF96-CFBC759AC8C5}
Class notes
IEEE 421.5-2016 AC9C excitation system model. It may be applied to excitation systems consisting of an ac alternator with either stationary or rotating rectifiers. The model consists of a PID type voltage regulator followed by a PI current regulator in cascade. Reference: IEEE 421.5-2016, 7.18.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEAC9C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{6B261B49-515E-47a8-ADF4-95C34F7138C1}show detailsdid not existPU [0..1]Controlled rectifier bridge equivalent gain (Ka). Typical value = 20.
Attribute notes
Controlled rectifier bridge equivalent gain (Ka). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{4D0D13C1-332A-43d7-AF6F-3F96C0F6BB10}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{E2DF0AD0-6412-43d9-B386-6A8C5F43335A}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc2i{7965D6CB-E33D-40d1-9F3C-695C4911D40F}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdi{7049F490-1DC7-4149-93A5-79102DFBF0C3}show detailsdid not existPU [0..1]Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1.
Attribute notes
Demagnetizing factor, function of exciter alternator reactances (Kd). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdri{34BABE78-A838-4962-9D75-1CCCD8E32867}show detailsdid not existPU [0..1]Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute notes
Voltage regulator derivative gain (Kdr). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{0B53E42F-0901-410d-AD07-A5B6CCFE4807}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{BEB2D86D-B150-4043-9B53-A5C2F4CBA645}show detailsdid not existPU [0..1]Exciter field current feedback gain (Kf). Typical value = 0,2.
Attribute notes
Exciter field current feedback gain (Kf). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{A39F9B67-3BD7-45aa-9D13-9DB787558C05}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki2i{DF886606-D1E0-42d4-A7FA-52CAD89D78C0}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{77461EF8-C7D9-417e-823B-5DFB6740B0C2}show detailsdid not existPU [0..1]Field current regulator integral gain (Kia). Typical value = 0.
Attribute notes
Field current regulator integral gain (Kia). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{0B13AD14-FBE3-46f6-B466-5388F0639C70}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir). Typical value = 10.
Attribute notes
Voltage regulator integral gain (Kir). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{C62D66DD-A595-400e-BABA-B9CF15251601}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{A1F5E9CB-4B67-4656-850B-54433F4ECDFA}show detailsdid not existPU [0..1]Field current regulator proportional gain (Kpa). Typical value = 4.
Attribute notes
Field current regulator proportional gain (Kpa). Typical value = 4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{6FCDAA55-84AC-49e1-AD1F-330B2BAC21A0}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr). Typical value = 10.
Attribute notes
Voltage regulator proportional gain (Kpr). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kwi{6BEAEBA6-B4DA-40d0-8433-25CBB2674287}show detailsdid not existPU [0..1]Free wheel equivalent feedback gain (Kw). Typical value = 0.
Attribute notes
Free wheel equivalent feedback gain (Kw). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekw
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
scti{12C60C9E-6956-49bc-A397-43C80BB40311}show detailsdid not existBoolean [0..1]Power stage type selector (Sct). True means it represents a thyristor converter (parameter different than 0 in IEEE model). False means it represents a chopper converter (parameter is set to 0 in IEEE model).
Attribute notes
Power stage type selector (Sct). True means it represents a thyristor converter (parameter different than 0 in IEEE model). False means it represents a chopper converter (parameter is set to 0 in IEEE model).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesct
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
seve1i{AC89BE4B-F49B-4a1d-AB8E-34C79F9C3A27}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,001.
Attribute notes
Exciter saturation factor at exciter output voltage Ve1, Se(Ve1). Typical value = 0,001.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
seve2i{6DE3939F-AE71-4cc8-A797-A53ABF147220}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,01.
Attribute notes
Exciter saturation factor at exciter output voltage Ve2, Se(Ve2). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameseve2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{026CD1A6-5E0C-4dd7-96D7-069596D1CC7D}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{600328BD-D65C-4b29-8BEF-1A54F3AC77A2}show detailsdid not existSeconds [0..1]Controlled rectifier bridge equivalent time constant (Ta) (>=0). Typical value = 0,0018.
Attribute notes
Controlled rectifier bridge equivalent time constant (Ta) (>=0). Typical value = 0,0018.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdri{F3DBEB13-4323-4a0e-8737-5B81CF31D428}show detailsdid not existSeconds [0..1]Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 0,01.
Attribute notes
Lag time constant for derivative channel of PID controller (Tdr) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{8C093F21-D337-43fe-B790-C6D4A71973AC}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{DA196912-ACD7-47f0-AD65-EAA781369EDC}show detailsdid not existSeconds [0..1]Field current feedback time constant (Tf) (>=0). Typical value = 0,01.
Attribute notes
Field current feedback time constant (Tf) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{43222767-27F8-47e8-A198-E7CA342AD5ED}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{9EB68EA3-7E29-4923-8E74-7B9557D8CE97}show detailsdid not existPU [0..1]Maximum current regulator output (Vamax). Typical value = 0,996.
Attribute notes
Maximum current regulator output (Vamax). Typical value = 0,996.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{F50452BF-AC85-4c68-95EC-2A948A3403D7}show detailsdid not existPU [0..1]Minimum current regulator output (Vamin). Typical value = -0,866.
Attribute notes
Minimum current regulator output (Vamin). Typical value = -0,866.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vb1maxi{FC94066B-D8C0-47a6-8FC3-FC884D0398AA}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vb1max). Typical value = 100.
Attribute notes
Maximum available exciter field voltage (Vb1max). Typical value = 100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb1max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vb2maxi{E4DDF706-5B94-470b-8D72-31468B07FC1F}show detailsdid not existPU [0..1]Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute notes
Maximum available compound field voltage (Vb2max). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevb2max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve1i{99D1F9EC-4DBD-48c8-BDCD-D665F12230F4}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,167.
Attribute notes
Exciter output voltage for saturation factor Se(Ve1), (Ve1). Typical value = 4,167.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ve2i{1BAF8AC0-5777-49c6-B8D8-1212F19115FD}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,125.
Attribute notes
Exciter output voltage for saturation factor Se(Ve2), (Ve2). Typical value = 3,125.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameve2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{77E1231F-93A8-4822-8754-253897A0269D}show detailsdid not existPU [0..1]Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute notes
Minimum exciter output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfemaxi{C7C87066-BFF0-45fb-939A-29D846BC56DE}show detailsdid not existPU [0..1]Maximum exciter field current limit reference (Vfemax). Typical value = 16.
Attribute notes
Maximum exciter field current limit reference (Vfemax). Typical value = 16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfwmaxi{8DF51448-7B03-46e1-9655-3CC49E5D54BD}show detailsdid not existPU [0..1]Maximum free wheel feedback (Vfwmax). Typical value = 10.
Attribute notes
Maximum free wheel feedback (Vfwmax). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfwmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vfwmini{EC8B1D35-36AE-4da5-AFBC-568A171B6AD4}show detailsdid not existPU [0..1]Minimum free wheel feedback (Vfwmin). Typical value = 0.
Attribute notes
Minimum free wheel feedback (Vfwmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevfwmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{148471D5-5E64-43b6-8F3F-271A4D03365F}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmaxi{34D9D74F-500C-4a9c-9549-D6A03F002145}show detailsdid not existPU [0..1]Maximum PID regulator output (Vpidmax). Typical value = 1,6.
Attribute notes
Maximum PID regulator output (Vpidmax). Typical value = 1,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpidmini{AF079E82-3B40-4f8a-AE0E-3A39E10EF515}show detailsdid not existPU [0..1]Minimum PID regulator output (Vpidmax). Typical value = 0.
Attribute notes
Minimum PID regulator output (Vpidmax). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpidmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{0F39FD88-95C1-4554-A713-D93AF4B65A92}show detailsdid not existPU [0..1]Maximum rectifier bridge output (Vrmax). Typical value = 19,92.
Attribute notes
Maximum rectifier bridge output (Vrmax). Typical value = 19,92.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{9CCDEE4C-7CBD-44e8-8C6C-47902AF9857E}show detailsdid not existPU [0..1]Minimum rectifier bridge output (Vrmin). Typical value = -17,32.
Attribute notes
Minimum rectifier bridge output (Vrmin). Typical value = -17,32.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{68008D38-46CE-4c83-AFB6-405AB1A0EA8A}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{6DE1955E-3BDA-431a-905F-E9581791EDDD}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{8777FB80-8F7F-4a0d-B79B-7EFC57A408BC}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC9C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEDC1Ci
Class notes
IEEE 421.5-2016 DC1C excitation system model. It is used to represent field controlled DC commutator exciters with continuously acting voltage regulators (especially the direct-acting rheostatic, rotating amplifier, and magnetic amplifier types). Reference: IEEE 421.5-2016, 6.3.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{5D230FCF-A338-4eb4-8FAF-C41D3CA3F12C}
Class notes
IEEE 421.5-2016 DC1C excitation system model. It is used to represent field controlled DC commutator exciters with continuously acting voltage regulators (especially the direct-acting rheostatic, rotating amplifier, and magnetic amplifier types). Reference: IEEE 421.5-2016, 6.3.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
e1i{E125389B-25D9-444a-944B-8A463B63B8F5}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 3,1.
Attribute notes
Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 3,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
e2i{A073C980-581A-4af8-A947-C9EC72B94A3C}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 2,3.
Attribute notes
Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 2,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efdmini{023B969A-F9D8-49ae-A3E0-98EC5CB0EA79}show detailsdid not existPU [0..1]Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute notes
Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefdmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{7EB74FEE-C63A-4189-876C-DF193C8905CB}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 46.
Attribute notes
Regulator output gain (Ka). Typical value = 46.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{9F0DA64C-7C54-459a-A129-E37436CE7FF2}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke).
Attribute notes
Exciter field proportional constant (Ke).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{843FCEF7-C6BA-4143-AE0E-D62D554691A0}show detailsdid not existPU [0..1]Rate feedback gain (Kf). Typical value = 0,1.
Attribute notes
Rate feedback gain (Kf). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
se1i{B697D196-C18B-4d23-869D-17DEE63C327F}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 0,33.
Attribute notes
Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 0,33.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
se2i{18B34D11-510A-4f1e-B0F5-770AC7415C11}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 0,1.
Attribute notes
Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{8EA59B6F-C701-4109-8A36-2EFF02BB9586}show detailsdid not existSeconds [0..1]Regulator time constant (Ta) (>=0). Typical value = 0,06.
Attribute notes
Regulator time constant (Ta) (>=0). Typical value = 0,06.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{6471540F-D4FD-4cde-8703-9DCA9EE1490F}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{9C7F9619-594D-4edf-AE88-B4DA59F70D35}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{0B10FEE2-5121-4e08-B56A-EB28D31448C6}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,46.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,46.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{438C73BB-05D5-4bc3-A33B-A13DFD95D6C9}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{8B0CA961-85CA-4e21-AF01-4F602E01F9C2}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{8821E32B-B474-4dc2-99AE-0385A4D8F0B5}show detailsdid not existPU [0..1]Maximum controller output (Vrmax). Typical value = 1.
Attribute notes
Maximum controller output (Vrmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{29E42A22-8D0F-4718-B176-B979D4A64C92}show detailsdid not existPU [0..1]Minimum controller output (Vrmin). Typical value = 0,9.
Attribute notes
Minimum controller output (Vrmin). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{C38147AF-DE0D-4e0e-AD15-02897577C699}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{8DF2CEFD-662E-4a84-B9C4-3D564287E7D5}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEDC2Ci
Class notes
IEEE 421.5-2016 DC2C excitation system model. It is used to represent field-controlled DC commutator exciters with continuously acting voltage regulators having power supplies derived from the generator or auxiliaries bus. It differs from the Type DC1A model only in the voltage regulator output limits, which are now proportional to terminal voltage magnitude Vt. Reference: IEEE 421.5-2016, 6.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1C1379A6-FD6C-46e2-B77E-C564B1994634}
Class notes
IEEE 421.5-2016 DC2C excitation system model. It is used to represent field-controlled DC commutator exciters with continuously acting voltage regulators having power supplies derived from the generator or auxiliaries bus. It differs from the Type DC1A model only in the voltage regulator output limits, which are now proportional to terminal voltage magnitude Vt. Reference: IEEE 421.5-2016, 6.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
e1i{7813924E-D229-4e8a-B672-75450AEDF94E}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 3,05.
Attribute notes
Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 3,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
e2i{8F8CB209-45F1-49f4-B3D5-19B191626C39}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 2,29.
Attribute notes
Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 2,29.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efdmini{818735C8-91F8-4970-92B4-B5B13637142E}show detailsdid not existPU [0..1]Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute notes
Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefdmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{9B3284A7-E7F0-4403-89B1-7483B50CF6A9}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 300.
Attribute notes
Regulator output gain (Ka). Typical value = 300.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{7FD63A36-48D7-4377-B630-FEF3F8ECF274}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{B31B56D2-248B-46d8-B764-85259605A464}show detailsdid not existPU [0..1]Rate feedback gain (Kf). Typical value = 0,02.
Attribute notes
Rate feedback gain (Kf). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
se1i{544380DD-E084-4068-A632-D502B40439E4}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 0,279.
Attribute notes
Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 0,279.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
se2i{8708CE8E-0418-4c24-9404-B626B3BA9C08}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 0,117.
Attribute notes
Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 0,117.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{043E8B5F-009B-45f4-96A6-9C72C162E15A}show detailsdid not existSeconds [0..1]Regulator time constant (Ta) (>=0). Typical value = 0,01.
Attribute notes
Regulator time constant (Ta) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{ECBCC121-E8F1-4732-8553-61273B124313}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{FC0C9AF9-F6DE-410a-A15C-2824AFD781E6}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{C06EBA46-A07E-452e-9342-C1C293739CD7}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 1,33.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 1,33.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{87253C78-E0D4-48da-A344-67C43CD293F4}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 0,675.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 0,675.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{21C90397-495A-445b-9506-CD4C5B3B2F9C}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{ACD07870-4784-4306-84DF-299EEAEA088B}show detailsdid not existPU [0..1]Maximum controller output (Vrmax). Typical value = 4,95.
Attribute notes
Maximum controller output (Vrmax). Typical value = 4,95.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{F197731E-8CB0-4bf4-A2B6-6682A4141B5B}show detailsdid not existPU [0..1]Minimum controller output (Vrmin). Typical value = -4,9.
Attribute notes
Minimum controller output (Vrmin). Typical value = -4,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{1FACDCFE-7996-4fd3-9025-8C39330A1E05}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{FFBBD716-5F22-4eea-B00B-772EF32EC75F}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEDC4Ci
Class notes
IEEE 421.5-2016 DC4C excitation system model. It utilizes a field-controlled DC commutator exciter with a continuously acting voltage regulator having supplies obtained from the generator or auxiliary services bus. Reference: IEEE 421.5-2016, 6.8.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{7183A825-F612-4fa5-AB78-9537502E7B61}
Class notes
IEEE 421.5-2016 DC4C excitation system model. It utilizes a field-controlled DC commutator exciter with a continuously acting voltage regulator having supplies obtained from the generator or auxiliary services bus. Reference: IEEE 421.5-2016, 6.8.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEDC4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
e1i{16D97DAF-9367-4244-A3C0-489DDADB06C4}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 4,8.
Attribute notes
Exciter output voltage for saturation factor Se(E1), (E1). Typical value = 4,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
e2i{6C632C4E-65F8-49fe-985A-4A89B8D47B07}show detailsdid not existPU [0..1]Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 3,6.
Attribute notes
Exciter output voltage for saturation factor Se(E2), (E2). Typical value = 3,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namee2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
efdmini{1AA6A787-24AD-4939-9417-DAA596B30F78}show detailsdid not existPU [0..1]Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute notes
Minimum generator field voltage (Efdmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefdmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{442174FD-2D3C-4fb5-AD93-E1CC070F6A13}show detailsdid not existPU [0..1]Regulator output gain (Ka). Typical value = 1.
Attribute notes
Regulator output gain (Ka). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kcli{7377EC1E-2902-4e12-85B2-8B9B67BBB46B}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kcl). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kcl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdri{5AE87996-708F-418f-AD0D-8FB771E4955E}show detailsdid not existPU [0..1]Regulator derivative gain (Kdr). Typical value = 20.
Attribute notes
Regulator derivative gain (Kdr). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{2A13D46F-4C71-48d4-A0A8-951871F8C8AA}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{BD91427A-2A06-4779-BC40-F950DDB94172}show detailsdid not existPU [0..1]Rate feedback gain (Kf). Typical value = 0.
Attribute notes
Rate feedback gain (Kf). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{9A912920-51FF-42b5-9086-E1F18B933808}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{C07254F9-1864-48c8-BAEC-B97065B6F2D8}show detailsdid not existPU [0..1]Regulator integral gain (Kir). Typical value = 20.
Attribute notes
Regulator integral gain (Kir). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{AA060F7E-DEB7-4df7-AC7C-DF9CED7B3894}show detailsdid not existPU [0..1]Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{FA41D188-2BE0-4192-BA55-3A4B716E4D6F}show detailsdid not existPU [0..1]Regulator proportional gain (Kpr). Typical value = 80.
Attribute notes
Regulator proportional gain (Kpr). Typical value = 80.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
se1i{A5111129-98B8-4433-8BEF-D0FACFE8DF09}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 1,54.
Attribute notes
Exciter saturation factor at exciter output voltage E1, Se(E1). Typical value = 1,54.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
se2i{8E2DC48D-2781-4ef9-B1A7-6CF47441D86C}show detailsdid not existFloat [0..1]Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 1,26.
Attribute notes
Exciter saturation factor at exciter output voltage E2, Se(E2). Typical value = 1,26.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namese2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{DDBA11AB-DEA7-4fc7-98D5-7720ADEBD0B8}show detailsdid not existBoolean [0..1]Logical switch 1. True means position A. False means position B. Typical value = true.
Attribute notes
Logical switch 1. True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{3F6211AB-354B-4702-9BE5-BF93DD6AD3BF}show detailsdid not existSeconds [0..1]Regulator time constant (Ta) (>=0). Typical value = 0,02.
Attribute notes
Regulator time constant (Ta) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdri{3ABADA90-567D-4b5f-B903-DFA0A343ED98}show detailsdid not existSeconds [0..1]Regulator derivative filter time constant (Tdr) (>=0). Typical value = 0,01.
Attribute notes
Regulator derivative filter time constant (Tdr) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdr
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{D5C2084E-F77C-4fef-867A-6287F5EB021B}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{EBFFBF6E-D3C2-451c-9636-AB494ED9BB25}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{D6219D60-89BD-4e48-B203-AFEBD47A8CD0}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{B49FDFF4-568C-4946-9855-154C9582DC1C}show detailsdid not existPU [0..1]Maximum available exciter field voltage (Vbmax). Typical value = 1,5.
Attribute notes
Maximum available exciter field voltage (Vbmax). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vemini{14D77B73-7EA9-460c-8CE1-7CAFBE55D2D3}show detailsdid not existPU [0..1]Exciter minimum output voltage (Vemin). Typical value = 0.
Attribute notes
Exciter minimum output voltage (Vemin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{4C7ACA55-6928-40cf-9033-D904DED83B48}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{9863A45F-2D32-45af-B474-A686B6929793}show detailsdid not existPU [0..1]Maximum controller output (Vrmax). Typical value = 2,7.
Attribute notes
Maximum controller output (Vrmax). Typical value = 2,7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{AAA5DCB4-BCED-4da5-8715-9DB138AF44B1}show detailsdid not existPU [0..1]Minimum controller output (Vrmin). Typical value = -2,7.
Attribute notes
Minimum controller output (Vrmin). Typical value = -2,7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{40F00829-040B-44b6-BFC2-F292D19C8404}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{31179520-600B-4849-84DA-ADBA86ACE2C8}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point. False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{090A1181-3514-4721-A25E-117988E0C008}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST10Ci
Class notes
IEEE 421.5-2016 ST10C excitation system model. It is a variation of the ST1C and ST5C models. In addition to ST5C model, this model offers alternatives for the application of the stabilizing signal coming from the PSS. It offers the option to apply the PSS signal at the AVR summing junction (voltage reference) and/or at the output of the gate structure, via separate but identical control elements. Furthermore, it offers the flexibility to interconnect the limiter signals at different locations depending on the actual equipment configuration or settings. The ST10C model also offers independent control settings for when a limiter is active, realized by the parallel configuration of lead-lag blocks. Reference: IEEE 421.5-2016, 8.18.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST10C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{98DBB1C6-0267-4588-B2A2-7EC097FAD72F}
Class notes
IEEE 421.5-2016 ST10C excitation system model. It is a variation of the ST1C and ST5C models. In addition to ST5C model, this model offers alternatives for the application of the stabilizing signal coming from the PSS. It offers the option to apply the PSS signal at the AVR summing junction (voltage reference) and/or at the output of the gate structure, via separate but identical control elements. Furthermore, it offers the flexibility to interconnect the limiter signals at different locations depending on the actual equipment configuration or settings. The ST10C model also offers independent control settings for when a limiter is active, realized by the parallel configuration of lead-lag blocks. Reference: IEEE 421.5-2016, 8.18.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST10C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kci{5E87D7C6-748B-4311-B963-E5C750CBEA24}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,01.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{8539105E-3C02-47ef-9F3F-40B827091AEF}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{CCBB910F-B0F7-494e-A9B7-87201807B1EF}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kri{E28D7E55-8A7F-434b-B38B-D5F322DC3AAD}show detailsdid not existPU [0..1]Regulator gain (Kr). Typical value = 500.
Attribute notes
Regulator gain (Kr). Typical value = 500.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{5084FE58-A315-4c20-A648-851075D616E8}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{34F22968-D568-4d91-AD16-65D07F2E4CA9}show detailsdid not existSeconds [0..1]Thyristor bridge firing control equivalent time constant (T1) (>=0). Typical value = 0,004.
Attribute notes
Thyristor bridge firing control equivalent time constant (T1) (>=0). Typical value = 0,004.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb1i{221BFE56-99E1-4e9e-A0C0-2A3825F8ADE8}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant (first block) (Tb1) (>=0). Typical value = 12,5.
Attribute notes
Voltage regulator denominator (lag) time constant (first block) (Tb1) (>=0). Typical value = 12,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb2i{44E163A3-A65A-4d6e-B868-92B08F5D5AF2}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant (second block) (Tb2) (>=0). Typical value = 0,1.
Attribute notes
Voltage regulator denominator (lag) time constant (second block) (Tb2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc1i{B5118037-0CDE-4628-92A4-8EC13DA36689}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant (first block) (Tc1) (>=0). Typical value = 1,5.
Attribute notes
Voltage regulator numerator (lead) time constant (first block) (Tc1) (>=0). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc2i{D68830FE-748D-4677-BA41-6B37224C58C6}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant (second block) (Tc2) (>=0). Typical value = 0,1.
Attribute notes
Voltage regulator numerator (lead) time constant (second block) (Tc2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{7B109AB0-7F12-4828-95AF-5AE10A3F0219}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
tob1i{996D9B85-2A53-4901-A982-BA8C9643F965}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant (first block) (Tob1) (>=0). Typical value = 12,5.
Attribute notes
OEL regulator denominator (lag) time constant (first block) (Tob1) (>=0). Typical value = 12,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tob2i{60805B26-E140-4cd8-AB06-0C65FC1818CA}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant (second block) (Tob2) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator denominator (lag) time constant (second block) (Tob2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc1i{94EF328E-ABD7-4037-B8EB-64E898211C19}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant (first block) (Toc1) (>=0). Typical value = 1,5.
Attribute notes
OEL regulator numerator (lead) time constant (first block) (Toc1) (>=0). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc2i{A760F37C-580B-41b4-BAA9-D5217237F25D}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant (second block) (Toc2) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator numerator (lead) time constant (second block) (Toc2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub1i{466D369F-50FF-4df6-B0D4-0AAC16027FB2}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant (first block) (Tub1) (>=0). Typical value = 12,5.
Attribute notes
UEL regulator denominator (lag) time constant (first block) (Tub1) (>=0). Typical value = 12,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub2i{095A61CD-670D-4e26-B6D8-9C42CEF45E9C}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant (second block) (Tub2) (>=0). Typical value = 0,1.
Attribute notes
UEL regulator denominator (lag) time constant (second block) (Tub2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc1i{0C26A593-A871-429b-B4AF-1F7BAF9E90E8}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant (first block) (Tuc1) (>=0). Typical value = 1,5.
Attribute notes
UEL regulator numerator (lead) time constant (first block) (Tuc1) (>=0). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc2i{1E808518-2BF0-4a0a-BB81-986EE9A7456F}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant (second block) (Tuc2) (>=0). Typical value = 0,1.
Attribute notes
UEL regulator numerator (lead) time constant (second block) (Tuc2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{FCDDD024-0476-4536-BDF7-496C2F0D83C7}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax). Typical value = 1,5.
Attribute notes
Maximum available exciter voltage (Vbmax). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{D6C34F90-1940-4d6c-ABAE-BC9AF2132311}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute notes
Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{52E6B142-15C0-4e3a-8C71-8F9977E5234D}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 10.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{B5B2F6A9-3329-465e-B1EB-FA3EC44E30C8}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -8,7.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -8,7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmaxi{5DCDE2CB-439C-429a-8204-C623A6D7E5C4}show detailsdid not existPU [0..1]Maximum PSS regulator output (Vrsmax). Typical value = 5.
Attribute notes
Maximum PSS regulator output (Vrsmax). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrsmini{75C32D24-74FA-4adc-B627-715B4F10EBE6}show detailsdid not existPU [0..1]Minimum PSS regulator output (Vrsmin). Typical value = -5.
Attribute notes
Minimum PSS regulator output (Vrsmin). Typical value = -5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrsmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{51C6ED1D-5F0D-441b-A8F6-2718629C7E1F}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vsInputKindi{FF568D5B-2644-48f5-9C3B-9BD9021B356B}show detailsdid not existVsInputKind [0..1]Alternate PSS input locations (Vs).
Attribute notes
Alternate PSS input locations (Vs).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsInputKind
Scale0
Scopepublic
Staticfalse
TypeVsInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{2DA63473-1936-490e-A19A-E0AEB2765AAE}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{CDDB4792-669B-467c-9990-4158F610035F}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST10C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST1Ci
Class notes
IEEE 421.5-2016 ST1C excitation system model. It is a potential-source–controlled rectifier excitation system intended to represent systems in which excitation power is supplied through a transformer from the generator terminals or the unit’s auxiliaries bus, and is regulated by a controlled rectifier. Reference: IEEE 421.5-2016, 8.3.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0EFAA11C-E981-4fbb-86A7-24AE6CBD953A}
Class notes
IEEE 421.5-2016 ST1C excitation system model. It is a potential-source–controlled rectifier excitation system intended to represent systems in which excitation power is supplied through a transformer from the generator terminals or the unit’s auxiliaries bus, and is regulated by a controlled rectifier. Reference: IEEE 421.5-2016, 8.3.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST1C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ilri{10BD965B-901D-4e77-A3D1-1E4977701753}show detailsdid not existPU [0..1]Exciter output current limit reference (Ilr). Typical value = 4,4.
Attribute notes
Exciter output current limit reference (Ilr). Typical value = 4,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameilr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{8774C6E8-2D6F-4928-9414-11C598C63A2C}show detailsdid not existPU [0..1]Voltage regulator gain (Ka). Typical value = 210.
Attribute notes
Voltage regulator gain (Ka). Typical value = 210.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{9EB1799B-7778-4356-B87E-37B33C137131}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,038.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,038.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{714D4792-1CAA-4d9b-B21E-85B8F896A531}show detailsdid not existPU [0..1]Rate feedback gain (Kf). Typical value = 0.
Attribute notes
Rate feedback gain (Kf). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
klri{97801F95-3955-47fa-A835-C542A8B5EFBB}show detailsdid not existPU [0..1]Exciter output current limiter gain (Klr). Typical value = 4,54.
Attribute notes
Exciter output current limiter gain (Klr). Typical value = 4,54.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameklr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{D0AD89E9-EB0E-4492-B2FA-ECB61D6AD842}show detailsdid not existSeconds [0..1]Voltage regulator time constant (Ta) (>=0). Typical value = 0.
Attribute notes
Voltage regulator time constant (Ta) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{0ACD657F-0406-46d1-BDD9-896EE1377254}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 1.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb1i{F0B4D1E5-6CAD-4de0-A529-BBEDDC98B80B}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb1) (>=0). Typical value = 0.
Attribute notes
Regulator denominator (lag) time constant (Tb1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{3ECE966A-06F2-4313-BD1D-1D634930F443}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc1i{E66806CE-CBFA-4cc4-B703-34E9915F699F}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc1) (>=0). Typical value = 0.
Attribute notes
Regulator numerator (lead) time constant (Tc1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{2FDC3CBD-2A21-4139-907F-DE41DB53DBE8}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf1) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf1) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{F66EF008-F466-4f9d-845A-087FCDF5D285}show detailsdid not existPU [0..1]Maximum regulator output (Vamax). Typical value = 6,43.
Attribute notes
Maximum regulator output (Vamax). Typical value = 6,43.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{B9A2103B-6B7D-4b29-90C4-0C64DE5DD76D}show detailsdid not existPU [0..1]Minimum regulator output (Vamin). Typical value = -6.
Attribute notes
Minimum regulator output (Vamin). Typical value = -6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vimaxi{07D954FA-BB0B-41ed-85FE-2EFD6745CEC2}show detailsdid not existPU [0..1]Maximum voltage error (regulator input) (Vimax). Typical value = 99.
Attribute notes
Maximum voltage error (regulator input) (Vimax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vimini{8F3E758C-212F-43f2-B40B-79894051FE25}show detailsdid not existPU [0..1]Minimum voltage error (regulator input) (Vimin). Typical value = -99.
Attribute notes
Minimum voltage error (regulator input) (Vimin). Typical value = -99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{32217C4F-099D-4666-AA7B-C570861A7905}show detailsdid not existVoelInputKind [0..1]Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute notes
Alternate OEL input locations (Voel). The value takeOverInnerLoop shall not be used in this model type.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeVoelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{E657A7DB-8E92-4ebf-B402-60464CBBFAA9}show detailsdid not existPU [0..1]Maximum exciter output (Vrmax). Typical value = 6,43.
Attribute notes
Maximum exciter output (Vrmax). Typical value = 6,43.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{50F6B993-0DA1-439d-ADFF-138CDF2F231A}show detailsdid not existPU [0..1]Minimum exciter output (Vrmin). Typical value = -6.
Attribute notes
Minimum exciter output (Vrmin). Typical value = -6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi{C6E0968A-2BCB-4da4-8AC7-F63703EEFCA0}show detailsdid not existBoolean [0..1]Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input at summation point at voltage regulator output.
Attribute notes
Alternate PSS input locations (Vs). True means input at voltage error calculation. False means input at summation point at voltage regulator output.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevs
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{2E63C416-CE33-4643-A6CE-14810B9ED187}show detailsdid not existVsclInputKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeVsclInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{58E9B1EF-6DD6-4b96-AE35-493CD0BE0D25}show detailsdid not existVuelInputKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeVuelInputKind
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST2Ci
Class notes
IEEE 421.5-2016 ST2C excitation system model. It represents compound-source rectifier excitation systems, which utilize both current and voltage sources (generator terminal quantities) to comprise the power source. Reference: IEEE 421.5-2016, 8.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{6AACAA96-8BFA-4289-B736-131E5938D625}
Class notes
IEEE 421.5-2016 ST2C excitation system model. It represents compound-source rectifier excitation systems, which utilize both current and voltage sources (generator terminal quantities) to comprise the power source. Reference: IEEE 421.5-2016, 8.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST2C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
efdmaxi{B9961FE3-C639-4839-8FDB-8EFDAA60556A}show detailsdid not existPU [0..1]Maximum generator field voltage (Efdmax). Typical value = 4,4.
Attribute notes
Maximum generator field voltage (Efdmax). Typical value = 4,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameefdmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kai{684AD1E1-0C42-4ab7-9146-95EEEE4D5CAB}show detailsdid not existPU [0..1]Voltage regulator gain (Ka). Typical value = 120.
Attribute notes
Voltage regulator gain (Ka). Typical value = 120.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{AF015CB9-94DC-4b2c-ACF7-8AA59718C9DB}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,1.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kei{A44FAE0E-4E5C-426e-AEDB-B1C1DC93AA17}show detailsdid not existPU [0..1]Exciter field proportional constant (Ke). Typical value = 1.
Attribute notes
Exciter field proportional constant (Ke). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameke
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{551715F4-B9EB-4c06-84AC-D42F4BE2A2C6}show detailsdid not existPU [0..1]Rate feedback gain (Kf). Typical value = 0,05.
Attribute notes
Rate feedback gain (Kf). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{2EB167EA-09A1-40bc-B8D3-AC2D0B639740}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{0DAA096B-8ACE-49d0-87A0-0AD0345C00D2}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir).
Attribute notes
Voltage regulator integral gain (Kir).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{0276C22C-9F14-4713-A17A-3068788D5936}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 4,88.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 4,88.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{5CCFF115-45A5-45d7-923F-99A9CDC6AD67}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr).
Attribute notes
Voltage regulator proportional gain (Kpr).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{68C8AADE-5AF7-47ac-AE2D-FA99E39861B4}show detailsdid not existSeconds [0..1]Voltage regulator time constant (Ta) (>=0). Typical value = 0,15.
Attribute notes
Voltage regulator time constant (Ta) (>=0). Typical value = 0,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tei{A64E12FA-9DDC-41d1-88D1-D7E5A6F526FE}show detailsdid not existSeconds [0..1]Exciter field time constant (Te) (>=0). Typical value = 0,5.
Attribute notes
Exciter field time constant (Te) (>=0). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namete
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{8F719F3E-8404-4efb-AE1F-68D30BACBB8D}show detailsdid not existSeconds [0..1]Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Rate feedback time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{E3748772-4B24-44bc-9B0B-4AD871FD9FA2}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{B44760A5-6830-4892-A0B9-510C8D9203FC}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax). Typical value = 5,2.
Attribute notes
Maximum available exciter voltage (Vbmax). Typical value = 5,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{36C94AC7-A795-4108-BB8F-02B14C11F3D2}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute notes
Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimaxi{BC72F9A8-CABD-42f0-AFC1-3F7EDED09F42}show detailsdid not existPU [0..1]Maximum regulator output (Vpimax).
Attribute notes
Maximum regulator output (Vpimax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimini{BCCCA832-4EAE-4507-A820-187C582E47FE}show detailsdid not existPU [0..1]Minimum regulator output (Vpimax).
Attribute notes
Minimum regulator output (Vpimax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{4B4333DF-9AF0-4420-97C9-8B2222D3DD59}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 1.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{AF5A9D66-5D97-41d9-BF66-5706217DDBDB}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = 0.
Attribute notes
Minimum regulator output (Vrmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{0005C2AD-5EAF-4e7d-AA41-6B4FBFBE9C6B}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{EDE4FB7C-0F29-42f4-98FB-064FF7EBE49B}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{0F3E3D29-6F5A-4412-8E6F-187501D8EF18}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST3Ci
Class notes
IEEE 421.5-2016 ST3C excitation system model. It utilizes a variety of controlled rectifier designs: full thyristor complements or hybrid bridges in either series or shunt configurations. The power source may consist of only a potential source, either fed from the machine terminals or from internal windings. Some designs may have compound power sources utilizing both machine potential and current. These power sources are represented as phasor combinations of machine terminal current and voltage and are accommodated by suitable parameters in the model. Reference: IEEE 421.5-2016, 8.7.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST3C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1B6C2D99-D75B-4a60-A5B4-A9AD320AE143}
Class notes
IEEE 421.5-2016 ST3C excitation system model. It utilizes a variety of controlled rectifier designs: full thyristor complements or hybrid bridges in either series or shunt configurations. The power source may consist of only a potential source, either fed from the machine terminals or from internal windings. Some designs may have compound power sources utilizing both machine potential and current. These power sources are represented as phasor combinations of machine terminal current and voltage and are accommodated by suitable parameters in the model. Reference: IEEE 421.5-2016, 8.7.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST3C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{F0919965-B15E-4a8b-89FE-424E093CFD5B}show detailsdid not existPU [0..1]Voltage regulator gain (Ka). Typical value = 200.
Attribute notes
Voltage regulator gain (Ka). Typical value = 200.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{3AC5AFA0-BD96-443d-816D-6D5DB716B25F}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kgi{33E456F5-6E87-4b40-8DB1-0DBA1AADC85D}show detailsdid not existPU [0..1]Feedback gain of field current regulator (Kg). Typical value = 1.
Attribute notes
Feedback gain of field current regulator (Kg). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{ECCAF1B5-C553-4e6e-9D91-8C5659AD8167}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{9764CDDD-D72F-4b6c-BE66-50D77A5A4944}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir).
Attribute notes
Voltage regulator integral gain (Kir).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmi{F3D43A6D-AAA5-4bf7-A373-7363D31AB16F}show detailsdid not existPU [0..1]Forward gain of inner loop field regulator (Km). Typical value = 7,93.
Attribute notes
Forward gain of inner loop field regulator (Km). Typical value = 7,93.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{8B0D517D-402E-44c8-A854-4A638F7846FE}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 6,15.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 6,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{9F17034C-E2E0-45bd-AE61-DA97F5951F4D}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr).
Attribute notes
Voltage regulator proportional gain (Kpr).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{0039B99A-645C-485d-8BCC-F4D5BF51374B}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{31004C10-3F58-4cc8-BBEA-CD067BA3B89A}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 10.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{9D48D452-D350-4f67-874D-20DF722348AD}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{A28B9D66-2F24-4737-A37C-5E9B680D5F64}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
tmi{CDFBAF37-E3C0-4152-9930-B06028EBDB5A}show detailsdid not existSeconds [0..1]Forward time constant of inner loop field regulator (Tm) (>=0). Typical value = 0,4.
Attribute notes
Forward time constant of inner loop field regulator (Tm) (>=0). Typical value = 0,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametm
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{E3A6A533-9D1F-447d-92CE-BFADCFDB5838}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax). Typical value = 6,9.
Attribute notes
Maximum available exciter voltage (Vbmax). Typical value = 6,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vgmaxi{638048EE-9321-443a-8678-BB859CF367D7}show detailsdid not existPU [0..1]Maximum field current feedback voltage (Vgmax). Typical value = 5,8.
Attribute notes
Maximum field current feedback voltage (Vgmax). Typical value = 5,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevgmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vimaxi{54DD7011-B3DE-43ff-B3B0-844DE6D15B8F}show detailsdid not existPU [0..1]Maximum voltage error (regulator input) (Vimax). Typical value = 0,2.
Attribute notes
Maximum voltage error (regulator input) (Vimax). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vimini{0E6E4F33-679D-46dc-97E1-381615881196}show detailsdid not existPU [0..1]Minimum voltage error (regulator input) (Vimin). Typical value = -0,2.
Attribute notes
Minimum voltage error (regulator input) (Vimin). Typical value = -0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmaxi{3041ABB0-0931-4d68-B0E3-56913AEB1ED7}show detailsdid not existPU [0..1]Maximum output of field current regulator (Vmmax). Typical value = 1.
Attribute notes
Maximum output of field current regulator (Vmmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmini{BBC61778-0F47-4aa5-9857-AE5E6345ADBD}show detailsdid not existPU [0..1]Minimum output of field current regulator (Vmmin). Typical value = 0.
Attribute notes
Minimum output of field current regulator (Vmmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{1A91680C-C6F1-41be-A903-5375EA0D8CAB}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute notes
Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimaxi{0899FA12-8FB0-4239-BA69-89A8C79E8245}show detailsdid not existPU [0..1]Maximum regulator output (Vpimax).
Attribute notes
Maximum regulator output (Vpimax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimini{26904A97-B3A3-4db2-B433-5B3EDF0B9866}show detailsdid not existPU [0..1]Minimum regulator output (Vpimax).
Attribute notes
Minimum regulator output (Vpimax).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{B0F4ED77-39EC-4dbf-9881-A49975A7D456}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 10.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{A9AEA1A9-E9C4-4bbd-8199-FE356BCF282D}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -10.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{8D592036-18BF-45ce-9C56-9B88E9BDE31B}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{C5245948-BAF6-4cb4-BCAE-2095D12982BA}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{5BDA8AC3-52D4-43cb-9679-B38F7548CA5D}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0,081.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0,081.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST4Ci
Class notes
IEEE 421.5-2016 ST4C excitation system model. This model is a variation of the Type ST3C model, with a proportional-integral (PI) regulator block replacing the lag-lead regulator characteristic that was in the ST3C model. Both potential and compound source rectifier excitation systems are modeled. The PI regulator blocks have nonwindup limits. Reference: IEEE 421.5-2016, 8.9.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{051323CE-F4BE-4079-8722-555B256D373F}
Class notes
IEEE 421.5-2016 ST4C excitation system model. This model is a variation of the Type ST3C model, with a proportional-integral (PI) regulator block replacing the lag-lead regulator characteristic that was in the ST3C model. Both potential and compound source rectifier excitation systems are modeled. The PI regulator blocks have nonwindup limits. Reference: IEEE 421.5-2016, 8.9.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST4C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kci{8233DA07-3B86-4317-B240-F7CC81FC3821}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,113.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,113.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kgi{1F0D9E7A-3FD0-4e6b-A228-1FB510D54524}show detailsdid not existPU [0..1]Feedback gain of field current regulator (Kg). Typical value = 0.
Attribute notes
Feedback gain of field current regulator (Kg). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{2478B81A-8198-4f7a-8009-52A74856491A}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kimi{88077ADC-81BC-490e-A66B-F161FB4C49C3}show detailsdid not existPU [0..1]Forward integral gain of inner loop field regulator (Kim). Typical value = 0.
Attribute notes
Forward integral gain of inner loop field regulator (Kim). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{B2ACBA8B-DB91-4eb9-A6C0-EA8352C0681D}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir).
Attribute notes
Voltage regulator integral gain (Kir).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{85E95889-BACC-48ae-A3C5-D754F3CF30EF}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 9,3.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 9,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpmi{574DF79E-2E42-4f16-9E94-FE77C72C1DFE}show detailsdid not existPU [0..1]Forward proportional gain of inner loop field regulator (Kpm). Typical value = 1.
Attribute notes
Forward proportional gain of inner loop field regulator (Kpm). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{02C007A8-BDF0-4a50-9752-CE4D5D809AE6}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr).
Attribute notes
Voltage regulator proportional gain (Kpr).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{93137122-7810-4fc6-B7C4-871370CE2920}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{75BDFD96-2FD8-4b6e-9D14-DCEBE2BA10B5}show detailsdid not existSeconds [0..1]Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0,2.
Attribute notes
Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{79039DEF-0C3E-4bb1-B6C6-D20A23328301}show detailsdid not existSeconds [0..1]Feedback time constant of field current regulator (Tg) (>=0). Typical value = 0.
Attribute notes
Feedback time constant of field current regulator (Tg) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{609F3500-E782-4cdf-A0CC-097524BE4D6F}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{206051DD-5D8C-4cdd-AEE1-552943AA6962}show detailsdid not existPU [0..1]Maximum exciter output (Vamax). Typical value = 99.
Attribute notes
Maximum exciter output (Vamax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{B75FA577-1DA5-44b0-84E0-B9C55C9677B2}show detailsdid not existPU [0..1]Minimum exciter output (Vamin). Typical value = -99.
Attribute notes
Minimum exciter output (Vamin). Typical value = -99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{284B4A19-0D23-4951-BA14-BAF4A57B9AC7}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax). Typical value = 11,63.
Attribute notes
Maximum available exciter voltage (Vbmax). Typical value = 11,63.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vgmaxi{DDBE7D0A-68C4-4f67-989B-B4321B345291}show detailsdid not existPU [0..1]Maximum feedback voltage for field current regulator (Vgmax). Typical value = 99.
Attribute notes
Maximum feedback voltage for field current regulator (Vgmax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevgmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmaxi{ECB4377D-B718-45c0-BC6D-E33C28AC3599}show detailsdid not existPU [0..1]Maximum output of field current regulator (Vmmax). Typical value = 99.
Attribute notes
Maximum output of field current regulator (Vmmax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmini{65FBDB4C-4BEB-4ce6-8B26-51AB3C6A55E4}show detailsdid not existPU [0..1]Minimum output of field current regulator (Vmmin). Typical value = -99.
Attribute notes
Minimum output of field current regulator (Vmmin). Typical value = -99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{6B3A6775-BE40-46d4-8324-DBAF8CDB0F03}show detailsdid not existInputsST4CKind [0..1]Alternate OEL input locations (Voel).
Attribute notes
Alternate OEL input locations (Voel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST4CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{992BEA21-027E-4933-A192-A3E8DAC08FCC}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 1.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{57C3D4F5-6498-463b-94D9-7B18C0268700}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -0,87.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -0,87.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi{E4B81144-7C24-495b-BDE4-735F10F27600}show detailsdid not existBoolean [0..1]Alternate PSS input locations (Vs). True means input at summation point before take-over UEL. False means input at summation point after take-over UEL.
Attribute notes
Alternate PSS input locations (Vs). True means input at summation point before take-over UEL. False means input at summation point after take-over UEL.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevs
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{2FC0B9E7-C91A-4e85-9EAF-1158EFF2B7D1}show detailsdid not existInputsST4CKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST4CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{1B9C0EEF-E44E-4459-8914-90D69172EE3A}show detailsdid not existInputsST4CKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST4CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{0CB07E18-6498-448b-AA9B-856AE64FD126}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0,124.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0,124.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST5Ci
Class notes
IEEE 421.5-2016 ST5C excitation system model. This model is is a variation of the Type ST1A model, with alternative overexcitation and underexcitation inputs and additional limits. Reference: IEEE 421.5-2016, 8.11.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST5C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1DB55B5C-8A23-4a16-BE60-DE69FDBA1E9C}
Class notes
IEEE 421.5-2016 ST5C excitation system model. This model is is a variation of the Type ST1A model, with alternative overexcitation and underexcitation inputs and additional limits. Reference: IEEE 421.5-2016, 8.11.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST5C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kci{79E2D2D6-B1B1-4af7-99EF-8D5DF1ECF160}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,004.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0,004.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kri{D15F77AE-8097-4121-BC3E-EC7502D61D57}show detailsdid not existPU [0..1]Regulator gain (Kr). Typical value = 200.
Attribute notes
Regulator gain (Kr). Typical value = 200.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{F728958B-CCBB-4cf2-AEAF-66F22DA72105}show detailsdid not existSeconds [0..1]Thyristor bridge firing control equivalent time constant (T1) (>=0). Typical value = 0,004.
Attribute notes
Thyristor bridge firing control equivalent time constant (T1) (>=0). Typical value = 0,004.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb1i{F2354200-47D6-48ea-A77A-29C96B1513E9}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant (first block) (Tb1) (>=0). Typical value = 6.
Attribute notes
Voltage regulator denominator (lag) time constant (first block) (Tb1) (>=0). Typical value = 6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb2i{1C0F866A-31C0-463a-B07E-7BEFBB46F1F3}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant (second block) (Tb2) (>=0). Typical value = 0,01.
Attribute notes
Voltage regulator denominator (lag) time constant (second block) (Tb2) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc1i{783607DD-21E6-4799-9FF0-CB5C00C86593}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant (first block) (Tc1) (>=0). Typical value = 0,8.
Attribute notes
Voltage regulator numerator (lead) time constant (first block) (Tc1) (>=0). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc2i{8441384A-8454-45b0-8722-2DABFF5FD6F0}show detailsdid not existSeconds [0..1]Voltage regulator numerator (lead) time constant (second block) (Tc2) (>=0). Typical value = 0,08.
Attribute notes
Voltage regulator numerator (lead) time constant (second block) (Tc2) (>=0). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tob1i{1C4CAF75-69A1-4895-8875-A76AD9C03530}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant (first block) (Tob1) (>=0). Typical value = 2.
Attribute notes
OEL regulator denominator (lag) time constant (first block) (Tob1) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tob2i{30196296-6245-4eb3-A956-502DC24D08E5}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant (second block) (Tob2) (>=0). Typical value = 0,08.
Attribute notes
OEL regulator denominator (lag) time constant (second block) (Tob2) (>=0). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametob2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc1i{C285ADD8-5861-4462-826F-B76B91C9D722}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant (first block) (Toc1) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator numerator (lead) time constant (first block) (Toc1) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toc2i{768ED62A-13C0-4c3d-8216-6B927E09E870}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant (second block) (Toc2) (>=0). Typical value = 0,08.
Attribute notes
OEL regulator numerator (lead) time constant (second block) (Toc2) (>=0). Typical value = 0,08.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub1i{411CFCDB-3848-47a9-9C6B-575FA87A0C5C}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant (first block) (Tub1) (>=0). Typical value = 10.
Attribute notes
UEL regulator denominator (lag) time constant (first block) (Tub1) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tub2i{49EC527C-8D87-4c9a-B448-4D4ACD547BC4}show detailsdid not existSeconds [0..1]UEL regulator denominator (lag) time constant (second block) (Tub2) (>=0). Typical value = 0,05.
Attribute notes
UEL regulator denominator (lag) time constant (second block) (Tub2) (>=0). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametub2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc1i{24B3A180-552B-44a7-A8AC-A386C965CC93}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant (first block) (Tuc1) (>=0). Typical value = 2.
Attribute notes
UEL regulator numerator (lead) time constant (first block) (Tuc1) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuc2i{47C23511-A4D1-4734-90A5-593B34888F59}show detailsdid not existSeconds [0..1]UEL regulator numerator (lead) time constant (second block) (Tuc2) (>=0). Typical value = 0,1.
Attribute notes
UEL regulator numerator (lead) time constant (second block) (Tuc2) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuc2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{9C5976B9-E7F7-4ba8-BC9A-4A3D6DD53B8F}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute notes
Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{23169CC7-87BF-43e3-B3BB-3AA8E57CC8D8}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 5.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{3D999E6A-5EAC-412f-9191-688A685CF2ED}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -4.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{BC745197-489F-43f4-AFB2-6867C4971AC6}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{F763C33D-8E80-4bf4-B0DF-62FA9DC370A3}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST6Ci
Class notes
IEEE 421.5-2016 ST6C excitation system model. It consists of a PI voltage regulator with an inner loop field voltage regulator and pre-control. The field voltage regulator implements a proportional control. The pre-control and the delay in the feedback circuit increase the dynamic response. Reference: IEEE 421.5-2016, 8.13.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST6C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{19E4BDF8-C940-46dc-957D-91DF52505D6C}
Class notes
IEEE 421.5-2016 ST6C excitation system model. It consists of a PI voltage regulator with an inner loop field voltage regulator and pre-control. The field voltage regulator implements a proportional control. The pre-control and the delay in the feedback circuit increase the dynamic response. Reference: IEEE 421.5-2016, 8.13.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST6C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ilri{A3769DC9-7EEA-482c-A999-433EDFE41BF0}show detailsdid not existPU [0..1]Exciter output current limit reference (Ilr). Typical value = 4,164.
Attribute notes
Exciter output current limit reference (Ilr). Typical value = 4,164.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameilr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{FDFEDF24-8B07-4a8b-8E86-BD8F059900A4}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kcii{8608447F-660B-4028-A01E-AC61BD2718B9}show detailsdid not existPU [0..1]Exciter output current limit adjustment (Kci). Typical value = 1,0577.
Attribute notes
Exciter output current limit adjustment (Kci). Typical value = 1,0577.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekci
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kffi{91C09DDF-1062-435a-B853-760E9005414C}show detailsdid not existPU [0..1]Pre-control gain constant of the inner loop field voltage regulator (Kff). Typical value = 1.
Attribute notes
Pre-control gain constant of the inner loop field voltage regulator (Kff). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekff
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kgi{3A6F9148-58A3-403e-911D-EDABE4232F57}show detailsdid not existPU [0..1]Feedback gain constant of the inner loop field voltage regulator (Kg). Typical value = 1.
Attribute notes
Feedback gain constant of the inner loop field voltage regulator (Kg). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekg
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{3015E095-79F2-45ea-A773-A38E55856F1C}show detailsdid not existPU [0..1]Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Compound circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{8BB0C11A-83C4-40f8-9524-95E3113E511A}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kia). Typical value = 45,094.
Attribute notes
Voltage regulator integral gain (Kia). Typical value = 45,094.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
klri{480CDC08-EEF4-4711-A8DF-EFC53DFDDD67}show detailsdid not existPU [0..1]Exciter output current limiter gain (Klr). Typical value = 17,33.
Attribute notes
Exciter output current limiter gain (Klr). Typical value = 17,33.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameklr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kmi{2DF93F11-987C-4ef9-8698-A521DA099E09}show detailsdid not existPU [0..1]Forward gain constant of the inner loop field voltage regulator (Km). Typical value = 1.
Attribute notes
Forward gain constant of the inner loop field voltage regulator (Km). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekm
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{10BCBB2E-A5EC-4e4b-B20C-A000585C3B96}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{2E15A2A6-95E7-409a-8050-582FE46A2CB8}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpa). Typical value = 18,038.
Attribute notes
Voltage regulator proportional gain (Kpa). Typical value = 18,038.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{B567CCF8-3795-4b5a-86F0-7563F54A841F}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{2A29EF04-996F-418b-9ACB-5537944797A2}show detailsdid not existSeconds [0..1]Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0,02.
Attribute notes
Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{3B30991D-A95F-434a-B204-2C6EA6AC617D}show detailsdid not existSeconds [0..1]Feedback time constant of inner loop field voltage regulator (Tg) (>=0). Typical value = 0,02.
Attribute notes
Feedback time constant of inner loop field voltage regulator (Tg) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{52F5575C-3654-4e9a-8772-C5689E0C5D58}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{D556A214-8354-443a-8CBA-4A26A7E56151}show detailsdid not existPU [0..1]Maximum voltage regulator output (Vamax). Typical value = 4,81.
Attribute notes
Maximum voltage regulator output (Vamax). Typical value = 4,81.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{59778CC7-6184-4eb0-BB33-C57CC3783259}show detailsdid not existPU [0..1]Minimum voltage regulator output (Vamin). Typical value = -3,85.
Attribute notes
Minimum voltage regulator output (Vamin). Typical value = -3,85.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{F49FE98F-8B7E-41b9-9B6E-373E6F600350}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax). Typical value = 99.
Attribute notes
Maximum available exciter voltage (Vbmax). Typical value = 99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmaxi{21157BC8-1899-4be9-91AB-72BBF3C89D93}show detailsdid not existPU [0..1]Maximum rectifier output limit (Vmmax). Typical value = 4,81.
Attribute notes
Maximum rectifier output limit (Vmmax). Typical value = 4,81.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmmini{25D00BED-7366-44d8-AEBB-CC1F17F51F5D}show detailsdid not existPU [0..1]Minimum rectifier output limit (Vmmin). Typical value = -3,85.
Attribute notes
Minimum rectifier output limit (Vmmin). Typical value = -3,85.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{7939E426-5656-4c21-8D66-64661799A2F6}show detailsdid not existInputsST6CKind [0..1]Alternate OEL input locations (Voel).
Attribute notes
Alternate OEL input locations (Voel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST6CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{E7297DC7-75B4-4ddc-9A95-9E3D046BB249}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 4,81.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 4,81.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{79817B70-D8F4-4366-AA62-F03BA567976E}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -3,85.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -3,85.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{A99AC2FB-4C55-49ab-B6DA-B6C06351170D}show detailsdid not existInputsST6CKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST6CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{7FBFAC62-72F5-4373-9A1C-A2632C3A081B}show detailsdid not existInputsST6CKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST6CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{A07C2DB5-D513-46b2-8C9F-AC83D81E694A}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST6C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST7Ci
Class notes
IEEE 421.5-2016 ST7C excitation system model. It is representative of static potential source excitation systems. In this system, the AVR consists of a proportional-integral (PI) voltage regulator. A phase lead-lag filter in series allows introduction of a derivative function, although this is typically used only with brushless excitation systems. In that case, the regulator is of the PID type. In addition, the terminal voltage channel includes a phase lead-lag filter. Reference: IEEE 421.5-2016, 8.15.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST7C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{E572B7F0-946C-466a-9462-AB4D6ED3531C}
Class notes
IEEE 421.5-2016 ST7C excitation system model. It is representative of static potential source excitation systems. In this system, the AVR consists of a proportional-integral (PI) voltage regulator. A phase lead-lag filter in series allows introduction of a derivative function, although this is typically used only with brushless excitation systems. In that case, the regulator is of the PID type. In addition, the terminal voltage channel includes a phase lead-lag filter. Reference: IEEE 421.5-2016, 8.15.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST7C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
khi{791241E9-5D1E-4918-AAC3-B14004891492}show detailsdid not existPU [0..1]Maximum excitation limit gain (Kh). Typical value = 1.
Attribute notes
Maximum excitation limit gain (Kh). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekh
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{43679DCD-045C-42f6-B6FA-9CF6D6D631D3}show detailsdid not existPU [0..1]PI regulator feedback gain (Kia). Typical value = 1.
Attribute notes
PI regulator feedback gain (Kia). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kli{FDB944BC-A006-4ba8-896C-18181105D8E8}show detailsdid not existPU [0..1]Minimum excitation limit gain (Kl). Typical value = 1.
Attribute notes
Minimum excitation limit gain (Kl). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{31651907-C979-4f68-9D43-3CD8A4AA34FE}show detailsdid not existPU [0..1]Voltage regulator gain (Kpa). Typical value = 40.
Attribute notes
Voltage regulator gain (Kpa). Typical value = 40.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{EA5BAC87-4F05-42dd-A790-07321B264068}show detailsdid not existSeconds [0..1]Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0.
Attribute notes
Thyristor bridge firing control equivalent time constant (Ta) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbi{502A3376-0EFA-49c4-A620-628581826642}show detailsdid not existSeconds [0..1]Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 1.
Attribute notes
Regulator denominator (lag) time constant (Tb) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tci{54C35E61-AC42-447c-96B8-E4E2EA087E1A}show detailsdid not existSeconds [0..1]Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute notes
Regulator numerator (lead) time constant (Tc) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{B5E0EDC5-4745-48e2-94DE-64038B877E3B}show detailsdid not existSeconds [0..1]Voltage regulator denominator (lag) time constant (Tf) (>=0). Typical value = 1.
Attribute notes
Voltage regulator denominator (lag) time constant (Tf) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tgi{AECFA631-9C67-4b26-90DF-63CAEB51453E}show detailsdid not existSeconds [0..1]Regulator input filter time constant (Tg) (>=0). Typical value = 1.
Attribute notes
Regulator input filter time constant (Tg) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametg
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tiai{2F09FAAF-28DD-4d57-9CB1-D59A1A60E9AC}show detailsdid not existSeconds [0..1]PI regulator feedback time constant (Tia) (>=0). Typical value = 3.
Attribute notes
PI regulator feedback time constant (Tia) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametia
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vmaxi{BABA0FCA-5CBF-4897-9BE4-E1FE7FA87D4C}show detailsdid not existPU [0..1]Maximum voltage reference (Vmax). Typical value = 1,1.
Attribute notes
Maximum voltage reference (Vmax). Typical value = 1,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vmini{C81352A6-3E70-4d80-BF41-D8D27CD5EBD3}show detailsdid not existPU [0..1]Minimum voltage reference (Vmin). Typical value = 0,9.
Attribute notes
Minimum voltage reference (Vmin). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelInputKindi{E3F92148-A36B-4480-BA4A-E771C7672310}show detailsdid not existInputsST7CKind [0..1]Alternate OEL input locations (Voel).
Attribute notes
Alternate OEL input locations (Voel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevoelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST7CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{6EF15000-2429-4b9a-B085-5361B4B39742}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 5.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{812FCD7F-1DA3-4809-89AB-C60465C7C9FD}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -4,5.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -4,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsclInputKindi{10B19F8C-C0C0-4553-B0F5-617939C92041}show detailsdid not existInputsST7CKind [0..1]Alternate SCL input locations (Vscl).
Attribute notes
Alternate SCL input locations (Vscl).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevsclInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST7CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelInputKindi{3B30DCDE-1F31-4448-A259-E17FAE26514C}show detailsdid not existInputsST7CKind [0..1]Alternate UEL input locations (Vuel).
Attribute notes
Alternate UEL input locations (Vuel).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NamevuelInputKind
Scale0
Scopepublic
Staticfalse
TypeInputsST7CKind
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST7C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST8Ci
Class notes
IEEE 421.5-2016 ST8C excitation system model. It has a PI Type voltage regulator followed by a PI current regulator in cascade. Both regulator blocks have non-windup limits. The cascaded AVR model is based on IEC 60034-16:1991. Reference: IEEE 421.5-2016, 8.16.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST8C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{FDE76095-D30F-4b76-A9B1-0F4D372FB110}
Class notes
IEEE 421.5-2016 ST8C excitation system model. It has a PI Type voltage regulator followed by a PI current regulator in cascade. Both regulator blocks have non-windup limits. The cascaded AVR model is based on IEC 60034-16:1991. Reference: IEEE 421.5-2016, 8.16.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST8C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{7D559997-3DF0-4301-B102-B1C253F5433D}show detailsdid not existPU [0..1]Field current regulator proportional gain (Ka). Typical value = 4,295.
Attribute notes
Field current regulator proportional gain (Ka). Typical value = 4,295.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc1i{ADEDC449-D4BC-4465-A728-5EB2BDD5EFF7}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0,062.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc1). Typical value = 0,062.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kc2i{0BD19E87-BE66-409c-A9EE-ECA194636A8D}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc2). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfi{1EBFE305-B79B-4386-9D95-C12ACE4421A0}show detailsdid not existPU [0..1]Exciter field current feedback gain (Kf). Typical value = 1.
Attribute notes
Exciter field current feedback gain (Kf). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{6ECADC7A-8D2F-4a3c-A8A8-108C81482560}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki2i{EED4513E-3F9B-41b8-976E-D85740297582}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiai{2B3A18B5-53BF-47ff-81B6-22D7DA0C8A11}show detailsdid not existPU [0..1]Field current regulator integral gain (Kia). Typical value = 0.
Attribute notes
Field current regulator integral gain (Kia). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekia
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kiri{B89D1417-EB8B-4d0b-BC0C-E3FBF4E5F0CE}show detailsdid not existPU [0..1]Voltage regulator integral gain (Kir). Typical value = 30.
Attribute notes
Voltage regulator integral gain (Kir). Typical value = 30.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekir
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{D34DB205-E0DC-4cf1-B760-4908BE0FDD66}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpai{3D59A387-7165-47b4-AE62-72F09116A901}show detailsdid not existPU [0..1]Field current regulator proportional gain (Kpa). Typical value = 2,38.
Attribute notes
Field current regulator proportional gain (Kpa). Typical value = 2,38.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpa
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpri{C1DDA5E0-959A-4337-8F3E-32CE50AED571}show detailsdid not existPU [0..1]Voltage regulator proportional gain (Kpr). Typical value = 6,6.
Attribute notes
Voltage regulator proportional gain (Kpr). Typical value = 6,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpr
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{ACCD3977-74E2-48ec-B915-9A1253FDEBAE}show detailsdid not existBoolean [0..1]Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Power source selector (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{F8CAE9A9-DA05-4e47-AC11-18124B868D4A}show detailsdid not existPU [0..1]Controlled rectifier bridge equivalent time constant (Tia) (>=0). Typical value = 0,0017.
Attribute notes
Controlled rectifier bridge equivalent time constant (Tia) (>=0). Typical value = 0,0017.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{74ECCA87-A254-4e22-8AC1-B400703AC92C}show detailsdid not existSeconds [0..1]Field current feedback time constant (Tf) (>=0). Typical value = 0,0226.
Attribute notes
Field current feedback time constant (Tf) (>=0). Typical value = 0,0226.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{14652442-A1F4-490e-897A-4387E1EB3C8F}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vamaxi{BFF13D7A-1BA1-42d5-8DBF-096D8DA9FC48}show detailsdid not existPU [0..1]Maximum field current regulator output (Vamax). Typical value = 1.
Attribute notes
Maximum field current regulator output (Vamax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vamini{D123254C-3137-400b-80E2-5390768716C1}show detailsdid not existPU [0..1]Minimum field current regulator output (Vamin). Typical value = -1.
Attribute notes
Minimum field current regulator output (Vamin). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevamin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmax1i{6CC1D63F-FBEB-4e04-BD62-998E6425B223}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax1). Typical value = 2.
Attribute notes
Maximum available exciter voltage (Vbmax1). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmax2i{5D448261-548F-45f3-8039-3D355403A8B5}show detailsdid not existPU [0..1]Maximum available exciter voltage (Vbmax2). Typical value = 0.
Attribute notes
Maximum available exciter voltage (Vbmax2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{B6F79EE1-17AB-4db1-B786-A9A3A50421DC}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimaxi{859CEEF7-9CE2-412a-BC77-488CEDB5B175}show detailsdid not existPU [0..1]Maximum voltage regulator output (Vpimax). Typical value = 16.
Attribute notes
Maximum voltage regulator output (Vpimax). Typical value = 16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vpimini{1ADF3979-E070-4846-A26B-337137025566}show detailsdid not existPU [0..1]Minimum voltage regulator output (Vpimax). Typical value = -16.
Attribute notes
Minimum voltage regulator output (Vpimax). Typical value = -16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevpimin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{99505A15-75A4-45d5-9C86-BC40F9FAE41D}show detailsdid not existPU [0..1]Maximum field current regulator output (Vrmax). Typical value = 4,27.
Attribute notes
Maximum field current regulator output (Vrmax). Typical value = 4,27.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{61588CF3-00BC-4579-A587-852F2644F951}show detailsdid not existPU [0..1]Minimum field current regulator output (Vrmin). Typical value = -3,64.
Attribute notes
Minimum field current regulator output (Vrmin). Typical value = -3,64.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{A5D5A986-726C-4777-B24B-42FB60FE4B07}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point (voltge error).False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point (voltge error).False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{B495CB5D-F3B2-498c-B996-9E63D4E6D235}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{36BB05F8-C132-4f8d-BA47-33951E8256C2}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST8C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcIEEEST9Ci
Class notes
IEEE 421.5-2016 ST9C excitation system model. It implements a proportional integral (PI) control logic. A differential stage is included in the path of the compensated voltage and the output of the differential stage is also added to the AVR summing point. This differential stage is intended to provide a faster reaction of the regulator in case of large voltage variations. A dead-band function is provided to eliminate the influence of the differential stage for small changes in the compensated voltage. Reference: IEEE 421.5-2016, 8.17.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST9C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{24180A2D-3AA9-4e92-8075-E5AA43719F90}
Class notes
IEEE 421.5-2016 ST9C excitation system model. It implements a proportional integral (PI) control logic. A differential stage is included in the path of the compensated voltage and the output of the differential stage is also added to the AVR summing point. This differential stage is intended to provide a faster reaction of the regulator in case of large voltage variations. A dead-band function is provided to eliminate the influence of the differential stage for small changes in the compensated voltage. Reference: IEEE 421.5-2016, 8.17.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameExcIEEEST9C
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kai{9365E39B-774A-4236-9CE6-01F2E809E748}show detailsdid not existPU [0..1]AVR gain (Ka). Typical value = 12.
Attribute notes
AVR gain (Ka). Typical value = 12.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameka
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kasi{B1C9FEED-E060-4243-93FE-8574768681B4}show detailsdid not existPU [0..1]Power converter gain (proportional to supply voltage) (Kas). Typical value = 6,1.
Attribute notes
Power converter gain (proportional to supply voltage) (Kas). Typical value = 6,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekas
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kci{A1063FBB-30CA-4f2b-8592-B4292DBFBA23}show detailsdid not existPU [0..1]Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute notes
Rectifier loading factor proportional to commutating reactance (Kc). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekc
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kii{07854F16-D77B-4321-B781-C3C9F1428536}show detailsdid not existPU [0..1]Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute notes
Potential circuit (current) gain coefficient (Ki). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{132B1BBA-E9F9-42f6-B648-B69A95BC0A98}show detailsdid not existPU [0..1]Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute notes
Potential circuit (voltage) gain coefficient (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kui{710E2C7D-2E00-407c-B252-7365BB8F324D}show detailsdid not existPU [0..1]Gain associated with activation of takeover UEL (Ku). Typical value = 10000.
Attribute notes
Gain associated with activation of takeover UEL (Ku). Typical value = 10000.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameku
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{E756286E-BE0A-4f82-B19F-7C8395E2C9C1}show detailsdid not existBoolean [0..1]Switch to select exciter supply configuration (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
Switch to select exciter supply configuration (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tai{D8149392-01FB-411b-A3CE-B1FCDECCC2F4}show detailsdid not existSeconds [0..1]Time constant of AVR (Ta) (>=0). Typical value = 2.
Attribute notes
Time constant of AVR (Ta) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameta
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tasi{E1ACF061-C14C-4198-BC66-2CDEBAA0EABE}show detailsdid not existSeconds [0..1]Equivalent time constant of power converter firing control (Tas) (>=0). Typical value = 0,0018.
Attribute notes
Equivalent time constant of power converter firing control (Tas) (>=0). Typical value = 0,0018.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametas
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
taueli{EF9568FC-EE30-4cf1-9EB7-B14753ECC5D0}show detailsdid not existSeconds [0..1]Time constant of underexcitation limiter (Tauel) (>=0). Typical value = 2.
Attribute notes
Time constant of underexcitation limiter (Tauel) (>=0). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametauel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tbdi{1A7135B8-9E84-49d2-9B57-8CC65EB62395}show detailsdid not existSeconds [0..1]Filter time constant of differential part of AVR (Tbd) (>=0). Typical value = 0,03.
Attribute notes
Filter time constant of differential part of AVR (Tbd) (>=0). Typical value = 0,03.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametbd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tcdi{967EC5C6-102B-4dfb-8E1F-9B7FE7D7E2FC}show detailsdid not existSeconds [0..1]Time constant of differential part of AVR (Tcd) (>=0). Typical value = 0,06.
Attribute notes
Time constant of differential part of AVR (Tcd) (>=0). Typical value = 0,06.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametcd
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
titapi{89FD6174-D65A-4fb6-991F-4B76E8F5F3AB}show detailsdid not existAngleDegrees [0..1]Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute notes
Potential circuit phase angle (degrees) (Titap). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametitap
Scale0
Scopepublic
Staticfalse
TypeAngleDegrees
UpperBound1
Tagged values — changes
BaselineDestination
none
vbmaxi{E78E3D08-0DA3-4554-B395-2B917E8ABB27}show detailsdid not existPU [0..1]Maximum limit on exciter voltage based on supply condition (Vbmax). Typical value = 1,2.
Attribute notes
Maximum limit on exciter voltage based on supply condition (Vbmax). Typical value = 1,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voeli{755D6E01-2A84-42bb-AB7D-CF8C45FADDE4}show detailsdid not existBoolean [0..1]Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over.
Attribute notes
Alternate OEL input locations (Voel). True means summation point (voltage error). False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmaxi{0B41C157-CF7F-4dd2-B7B3-F058CB589CC6}show detailsdid not existPU [0..1]Maximum regulator output (Vrmax). Typical value = 1.
Attribute notes
Maximum regulator output (Vrmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vrmini{F49A5DAB-AB2D-44d3-9DF3-5B37C2C0688C}show detailsdid not existPU [0..1]Minimum regulator output (Vrmin). Typical value = -0,866.
Attribute notes
Minimum regulator output (Vrmin). Typical value = -0,866.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevrmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vscli{34DC4413-B929-46e7-8FAF-2B6289095DA0}show detailsdid not existBoolean [0..1]Alternate SCL input locations (Vscl). True means summation point (voltge error).False means take-over.
Attribute notes
Alternate SCL input locations (Vscl). True means summation point (voltge error).False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevscl
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vueli{666A2D59-9A70-4030-927F-FC56CB58E693}show detailsdid not existBoolean [0..1]Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over.
Attribute notes
Alternate UEL input locations (Vuel). True means summation point (voltge error). False means take-over.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuel
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
xli{50B55937-3978-4b2a-B01F-7E6340177C93}show detailsdid not existPU [0..1]Reactance associated with potential source (Xl). Typical value = 0.
Attribute notes
Reactance associated with potential source (Xl). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namexl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
zai{C45284E5-80D4-4146-80FD-DF8DDB6E1B6D}show detailsdid not existFloat [0..1]Dead-band for differential part influence on AVR (Za). Typical value = 0,036.
Attribute notes
Dead-band for differential part influence on AVR (Za). Typical value = 0,036.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameza
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST9C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙InputsST4CKind«enumeration»i
Class notes
Defines the alternate input locations for IEEE ST4C model.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST4CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{736DCFB7-C486-4455-9F80-2F0B317D1327}
Class notes
Defines the alternate input locations for IEEE ST4C model.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST4CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{AD5F9A11-2E17-4f30-8A6D-52E55C05D931}show detailsdid not exist [1..1]Input is at summation point (at voltage error).
Attribute notes
Input is at summation point (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverInnerLoopi{113B784B-A879-44d0-8028-FC9C8281FAE4}show detailsdid not exist [1..1]Input is at take-over at inner-loop output.
Attribute notes
Input is at take-over at inner-loop output.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverInnerLoop
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageRegInputi{DF70142B-03DF-4241-BCA0-F3F1F6AB9609}show detailsdid not exist [1..1]Input is at take-over at voltage regulator input.
Attribute notes
Input is at take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageRegInput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙InputsST6CKind«enumeration»i
Class notes
Defines the alternate input locations for IEEE ST6C model.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST6CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{DA458133-76A4-4791-9625-3094ED2DCD56}
Class notes
Defines the alternate input locations for IEEE ST6C model.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST6CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{CD81BD7E-68AE-4d6d-A850-747E8D29A6B0}show detailsdid not exist [1..1]Input is at summation point (at voltage error).
Attribute notes
Input is at summation point (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
summationPointAVRi{E69EECC4-6E3D-4c47-8852-807532AEE5BB}show detailsdid not exist [1..1]Input is at summation point (at AVR input).
Attribute notes
Input is at summation point (at AVR input).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPointAVR
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverInnerLoopi{DE1DFEB3-6AB0-4460-A351-2DBC6A3964E3}show detailsdid not exist [1..1]Input is at take-over at inner-loop output.
Attribute notes
Input is at take-over at inner-loop output.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverInnerLoop
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageRegInputi{B0AD61C8-0120-42fa-BCCA-E283EE497549}show detailsdid not exist [1..1]Input is at take-over at voltage regulator input.
Attribute notes
Input is at take-over at voltage regulator input.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageRegInput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙InputsST7CKind«enumeration»i
Class notes
Defines the alternate input locations for IEEE ST7C model.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST7CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{27AEBDB2-1C51-4dbb-86BC-F991054665B6}
Class notes
Defines the alternate input locations for IEEE ST7C model.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameInputsST7CKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{667D85CD-3C90-44b8-84D7-150F4F585A99}show detailsdid not exist [1..1]Input is at summation point (voltage reference setpoint).
Attribute notes
Input is at summation point (voltage reference setpoint).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageRefi{76DF17DC-3B6A-40c3-BA4E-46903C90932C}show detailsdid not exist [1..1]Input is at take-over (at voltage reference).
Attribute notes
Input is at take-over (at voltage reference).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageRef
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageRegOutputi{A30C244F-2219-477b-AD04-14EA996F1E9C}show detailsdid not exist [1..1]Input is at take-over (at voltage regulator output).
Attribute notes
Input is at take-over (at voltage regulator output).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageRegOutput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙VoelInputKind«enumeration»i
Class notes
Defines the alternate OEL input locations.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVoelInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{F6A899F0-9C0D-41bb-900D-D5F37645444D}
Class notes
Defines the alternate OEL input locations.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVoelInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{D518E794-C33F-42d3-B2B6-26DA398D2CCB}show detailsdid not exist [1..1]Input is at summation point (at voltage error).
Attribute notes
Input is at summation point (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverInnerLoopi{31E967C3-1ABC-4224-AC2F-A6F7DECB2AC3}show detailsdid not exist [1..1]Input is at take-over (at output of inner loop regulator).
Attribute notes
Input is at take-over (at output of inner loop regulator).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverInnerLoop
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverRegOutputi{2A3690D9-FA3A-40c3-A644-58DCEB8C1D1A}show detailsdid not exist [1..1]Input is at take-over (at voltage regulator output).
Attribute notes
Input is at take-over (at voltage regulator output).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverRegOutput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageErrori{013E4B48-0DA1-402b-BBE6-B13E59A9B391}show detailsdid not exist [1..1]Input is at take-over (at voltage error).
Attribute notes
Input is at take-over (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageError
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙VsclInputKind«enumeration»i
Class notes
Defines the alternate SCL input locations.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVsclInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{C8E052F9-A16D-411b-9F74-29388CD940C0}
Class notes
Defines the alternate SCL input locations.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVsclInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{55E593A8-9878-42fe-BBCC-BFFA827B46AC}show detailsdid not exist [1..1]Input is at summation point (at voltage error).
Attribute notes
Input is at summation point (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverRegOutputi{A0F2BB42-D7E4-4aae-98EA-BB62B7BD3E9C}show detailsdid not exist [1..1]Input is at take-over (at voltage regulator output).
Attribute notes
Input is at take-over (at voltage regulator output).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverRegOutput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageErrori{D11A7FA7-CA9F-40e8-813D-5043BFF76A50}show detailsdid not exist [1..1]Input is at take-over (at voltage error).
Attribute notes
Input is at take-over (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageError
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙VsInputKind«enumeration»i
Class notes
Defines the alternate PSS input locations.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVsInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{D60CCCF4-8582-4e97-99C9-22E2D4D732E9}
Class notes
Defines the alternate PSS input locations.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVsInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
outputAVRi{4C4B0A2F-A29C-407e-B0B8-51AA9449843A}show detailsdid not exist [1..1]Input is at output of AVR (after take-over limits).
Attribute notes
Input is at output of AVR (after take-over limits).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NameoutputAVR
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
voltageErrori{471146BE-8FA3-4066-9372-5C38109C9499}show detailsdid not exist [1..1]Input is at voltage error calculation.
Attribute notes
Input is at voltage error calculation.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamevoltageError
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
voltageErrorOrAfterTakeOveri{7EFBFC66-9C19-4a58-8C42-21DDE19B717F}show detailsdid not exist [1..1]Input is at voltage error or after take-over limits.
Attribute notes
Input is at voltage error or after take-over limits.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamevoltageErrorOrAfterTakeOver
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙VuelInputKind«enumeration»i
Class notes
Defines the alternate UEL input locations.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVuelInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0C328F54-74D1-437a-9463-3DA36761A9F9}
Class notes
Defines the alternate UEL input locations.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameVuelInputKind
ParentPackageIEEE4215from2016
Phase1.0
Scopepublic
StatusProposed
Stereotypeenumeration
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
summationPointi{259B65B7-AD1B-4736-B288-211497BB0265}show detailsdid not exist [1..1]Input is at summation point (at voltage error).
Attribute notes
Input is at summation point (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NamesummationPoint
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverRegOutputi{8F76D656-7AB9-4ffe-BBE5-42F62EFE5707}show detailsdid not exist [1..1]Input is at take-over (at voltage regulator output).
Attribute notes
Input is at take-over (at voltage regulator output).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverRegOutput
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
takeOverVoltageErrori{2F8E3228-0A6A-4f9c-AF6B-06F0027BF21E}show detailsdid not exist [1..1]Input is at take-over (at voltage error).
Attribute notes
Input is at take-over (at voltage error).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound1
NametakeOverVoltageError
Scale0
Scopepublic
Staticfalse
Stereotypeenum
UpperBound1
Tagged values — changes
BaselineDestination
none
Added diagrams (1)
▶▦IEEE4215from2016i
Diagram notes
The diagram shows the excitation system models from IEEE 421.5-2016.
Diagram metadata — changes
BaselineDestination
AuthorChavdarIvanov
CreatedDate2021-01-02 08:51:29
DiagramTypeClassDiagram
ModifiedDate2022-03-18 22:35:16
NameIEEE4215from2016
PackageEAPK_1E5D2248_C621_443e_98E0_864F168D2479
ADDED{4C16AD7A-0DCF-413e-9D8A-DAF869262EDB}
Diagram notes
The diagram shows the excitation system models from IEEE 421.5-2016.
▤Metadata
BaselineDestination
AuthorChavdarIvanov
CreatedDate2021-01-02 08:51:29
DiagramTypeClassDiagram
ModifiedDate2022-03-18 22:35:16
NameIEEE4215from2016
PackageEAPK_1E5D2248_C621_443e_98E0_864F168D2479
▦Diagram
Baseline
Diagram did not exist in the baseline model.
Destination
IEEE4215from2016 (destination)
Changed classes (10)
▶⚙ExcAC3Ai
Class notes
Modified IEEE AC3A alternator-supplied rectifier excitation system with different field current limit.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{442B06CD-43E7-4cc5-9E46-87B65F5E90A8}
Class notes
Modified IEEE AC3A alternator-supplied rectifier excitation system with different field current limit.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ve1i{D09A6721-BE9B-4f17-9DA9-65A9B3882A26}show detailsPU [0..1]PU [0..1]Exciter alternator output voltages back of commutating reactance at which saturation is defined (<i>Ve</i><i><sub>1</sub></i>) (> 0). Typical value = 6.,24.
Attribute notes (destination, redlined)
Exciter alternator output voltages back of commutating reactance at which saturation is defined (<i>Ve</i><i><sub>1</sub></i>) (> 0). Typical value = 6.,24.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcELIN1i
Class notes (destination, redlined)
Static PI transformer fed excitation system ELIN (VATECH) - simplified model. This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. A power system stabilizer with power input is included in the model.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{61B64CDD-C0DC-4805-9FAE-F5CE6F84BE93}
Class notes (destination, redlined)
Static PI transformer fed excitation system ELIN (VATECH) - simplified model. This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. A power system stabilizer with power input is included in the model.
Class 'ExcELIN1' has no other changes. The shows its notes and every changed property.
▶⚙ExcELIN2i
Class notes (destination, redlined)
Detailed excitation system ELIN (VATECH). This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. Power system stabilizer models used in conjunction with this excitation system model: PssELIN2, PssIEEE2B, Pss2B.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{A70C011D-657F-48d6-9773-355DE124B959}
Class notes (destination, redlined)
Detailed excitation system ELIN (VATECH). This model represents an all-static excitation system. A PI voltage controller establishes a desired field current set point for a proportional current controller. The integrator of the PI controller has a follow-up input to match its signal to the present field current. Power system stabilizer models used in conjunction with this excitation system model: PssELIN2, PssIEEE2B, Pss2B.
Class 'ExcELIN2' has no other changes. The shows its notes and every changed property.
▶⚙ExcitationSystemDynamicsi
Class notes
Excitation system function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{F119E4EC-2DC8-4801-B68B-A282AF621324}
Class notes
Excitation system function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC6C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC11C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC7C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC10C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST7C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC9C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST8C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST10C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC8C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST9C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEST6C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEAC2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcIEEEDC1C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndExcitationSystemDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙ExcNIi
Class notes
Bus or solid fed SCR (silicon-controlled rectifier) bridge excitation system model type NI (NVE).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{0CD180C8-EE66-4407-B672-6462C586CCC5}
Class notes
Bus or solid fed SCR (silicon-controlled rectifier) bridge excitation system model type NI (NVE).
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ri{F337910E-26D5-4a91-8B95-BF3FB984C9CD}show detailsPU [0..1]PU [0..1]Ratio of field discharge resistance to field winding resistance <i>rc</i> / <i>rfd</i> (<i>R</i>) (>= 0). If it is 0 it means that the exciter has negative current capability >. If it is greater than 0 it means that the exciter does not have negative current capability. Typical value = 5.
Attribute notes (destination, redlined)
Ratio of field discharge resistance to field winding resistance <i>rc</i> / <i>rfd</i> (<i>R</i>) (>= 0). If it is 0 it means that the exciter has negative current capability >. If it is greater than 0 it means that the exciter does not have negative current capability. Typical value = 5.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcPICi
Class notes (destination, redlined)
Proportional/integral regulator excitation system. This model can be used to represent excitation systems with a proportional-integral (PI) voltage regulator controller.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{059AD67D-F00F-4fff-A769-4267112802A1}
Class notes (destination, redlined)
Proportional/integral regulator excitation system. This model can be used to represent excitation systems with a proportional-integral (PI) voltage regulator controller.
Class 'ExcPIC' has no other changes. The shows its notes and every changed property.
▶⚙ExcREXSi
Class notes (destination, redlined)
General purpose rotating excitation system. This model can be used to represent a wide range of excitation systems whose DC power source is an AC or DC generator. It encompasses IEEE type AC1, AC2, DC1, and DC2 excitation system models.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{F3E4EB5B-1DEA-418b-945D-2F82E47C8600}
Class notes (destination, redlined)
General purpose rotating excitation system. This model can be used to represent a wide range of excitation systems whose DC power source is an AC or DC generator. It encompasses IEEE type AC1, AC2, DC1, and DC2 excitation system models.
Class 'ExcREXS' has no other changes. The shows its notes and every changed property.
▶⚙ExcRQBi
Class notes (destination, redlined)
Excitation system type RQB (four-loop regulator, r?gulateurregulateur quatre boucles, developed in France) primarily used in nuclear or thermal generating units. This excitation system shall be always used together with power system stabilizer type PssRQB.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{1EF393B6-BC78-42f1-B8C7-30791D76FC50}
Class notes (destination, redlined)
Excitation system type RQB (four-loop regulator, r?gulateurregulateur quatre boucles, developed in France) primarily used in nuclear or thermal generating units. This excitation system shall be always used together with power system stabilizer type PssRQB.
Class 'ExcRQB' has no other changes. The shows its notes and every changed property.
▶⚙ExcSCRXi
Class notes
Simple excitation system with generic characteristics typical of many excitation systems; intended for use where negative field current could be a problem.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{A153B28E-4577-4ff7-9EFA-EF47377694D7}
Class notes
Simple excitation system with generic characteristics typical of many excitation systems; intended for use where negative field current could be a problem.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
rcrfdi{E9A327DF-C4C7-4b09-B83B-EB1B93D47B0F}show detailsFloat [0..1]Float [0..1]Ratio of field discharge resistance to field winding resistance ([<i>rc / rfd]</i>). If it is 0 it means that the exciter has negative current capability. If it is greater than 0 it means that the exciter does not have negative current capability. Typical value = 0.
Attribute notes (destination, redlined)
Ratio of field discharge resistance to field winding resistance ([<i>rc / rfd]</i>). If it is 0 it means that the exciter has negative current capability. If it is greater than 0 it means that the exciter does not have negative current capability. Typical value = 0.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
▶⚙ExcSKi
Class notes (destination, redlined)
Slovakian excitation system. UEL and secondary voltage control are included in this model. When this model is used, there cannot be a separate underexcitation limiter or VAr controller model.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{1EE78E1C-0446-48dd-87E8-AA4990E99CB7}
Class notes (destination, redlined)
Slovakian excitation system. UEL and secondary voltage control are included in this model. When this model is used, there cannot be a separate underexcitation limiter or VAr controller model.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
qzi{B38B207C-40F5-4827-9F32-3C70C7E8C6E6}show detailsPU [0..1]removed from model
Attribute notes (baseline)
Desired value (setpoint) of reactive power, manual setting (<i>Qz</i>).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
Nameqz
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
remotei{7C164CD6-B160-4ec5-8EA4-34D336810E57}show detailsBoolean [0..1]Boolean [0..1]Selector to apply automatic calculation in secondary controller model (<i>remote</i>). true = automatic calculation is activated. In this case both signals Qz and Qzs sum up. false = manual set is active; the use of desired value of reactive power (<i>Qz</i>) is required. Typical value = true.
Attribute notes (destination, redlined)
Selector to apply automatic calculation in secondary controller model (<i>remote</i>). true = automatic calculation is activated. In this case both signals Qz and Qzs sum up. false = manual set is active; the use of desired value of reactive power (<i>Qz</i>) is required. Typical value = true.
Attribute metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
sbasei{D15ECA3E-3FD1-4584-B2CC-B70884FCDA83}show detailsApparentPower [0..1]removed from model
Attribute notes (baseline)
Apparent power of the unit (<i>Sbase</i>) (> 0). Unit = MVA. Typical value = 259.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsLiteralfalse
IsOrderedfalse
LowerBound0
Namesbase
Scale0
Scopepublic
Staticfalse
TypeApparentPower
UpperBound1
Tagged values — changes
BaselineDestination
none
Changed diagrams (39)
▶▦ExcAC1Ai
Diagram notes
This diagram describes the ExcAC1A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:11:492022-03-18 22:35:09
CHANGED{3BC63289-3CC4-4580-8A35-5E31F82250C1}
Diagram notes
This diagram describes the ExcAC1A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:11:492022-03-18 22:35:09
Diagram 'ExcAC1A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC2Ai
Diagram notes
This diagram describes the ExcAC2A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed;</li> <li>The upper limit on <i>Ve</i> represents the effect of the field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. In the real system, the limiter is implemented by a low value gate just before <i>Kb</i>. The input to this LV gate is <i>Kl</i> x (<i>Vlr</i> – <i>Vfe</i>). If the values of <i>Kl </i>and <i>Vlr</i> are given, <i>Vfemax </i>can be calculated as <i>Vlr</i> x <i>Kl</i> x <i>Kb</i> / (1 + <i>Kl</i> x <i>Kb</i>).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:12:122022-03-18 22:35:00
CHANGED{99A80F43-4266-4672-B622-92A070C0831C}
Diagram notes
This diagram describes the ExcAC2A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed;</li> <li>The upper limit on <i>Ve</i> represents the effect of the field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. In the real system, the limiter is implemented by a low value gate just before <i>Kb</i>. The input to this LV gate is <i>Kl</i> x (<i>Vlr</i> – <i>Vfe</i>). If the values of <i>Kl </i>and <i>Vlr</i> are given, <i>Vfemax </i>can be calculated as <i>Vlr</i> x <i>Kl</i> x <i>Kb</i> / (1 + <i>Kl</i> x <i>Kb</i>).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:12:122022-03-18 22:35:00
Diagram 'ExcAC2A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC3Ai
Diagram notes
This diagram describes the ExcAC3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>The upper limit on <i>Ve</i> is an approximate representation of the effect of the maximum field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. The lower limit (<i>Vemin</i>) on <i>Ve</i> is an approximate representation of the minimum field voltage limiter. </li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:12:232022-03-18 22:34:51
CHANGED{58587B1A-6E30-4d03-BCB0-510FE3ECB277}
Diagram notes
This diagram describes the ExcAC3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>The upper limit on <i>Ve</i> is an approximate representation of the effect of the maximum field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. The lower limit (<i>Vemin</i>) on <i>Ve</i> is an approximate representation of the minimum field voltage limiter. </li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:12:232022-03-18 22:34:51
Diagram 'ExcAC3A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC4Ai
Diagram notes
This diagram describes the ExcAC4A excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:12:382022-03-18 22:34:43
CHANGED{742AFC8E-71B1-4ed0-B6F0-D0A3BCE4E8B4}
Diagram notes
This diagram describes the ExcAC4A excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:12:382022-03-18 22:34:43
Diagram 'ExcAC4A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC5Ai
Diagram notes
This diagram describes the ExcAC5A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:12:522022-03-18 22:34:36
CHANGED{3BD737FB-4CCF-4940-8AB5-E4FD385048E3}
Diagram notes
This diagram describes the ExcAC5A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:12:522022-03-18 22:34:36
Diagram 'ExcAC5A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC6Ai
Diagram notes
This diagram describes the ExcAC6A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:13:052022-03-18 22:34:28
CHANGED{6E09B3A8-D86C-45f6-89AA-308C96070CAC}
Diagram notes
This diagram describes the ExcAC6A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1 the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:13:052022-03-18 22:34:28
Diagram 'ExcAC6A' has no other changes. The shows its notes and every changed property.
▶▦ExcAC8Bi
Diagram notes
This diagram describes the ExcAC8A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The upper limit on <i>Ve</i> represents the effect of the field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. </li> <li>The non-windup limits are defined as in Annex E of the IEEE 421.5-2005.</li> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:13:192022-03-18 22:34:20
CHANGED{3080055E-B2FC-40a0-B93F-F5B26970344D}
Diagram notes
This diagram describes the ExcAC8A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The upper limit on <i>Ve</i> represents the effect of the field current limiter. If <i>Vfemax</i> is zero, this limit will not be enforced. </li> <li>The non-windup limits are defined as in Annex E of the IEEE 421.5-2005.</li> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:13:192022-03-18 22:34:20
Diagram 'ExcAC8B' has no other changes. The shows its notes and every changed property.
▶▦ExcANSi
Diagram notes
This diagram describes the ExcANS excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>Limits on <i>V</i><i><sub>R</sub></i> signal are modelled as follows: </li> </ol> - If <i>K</i><i><sub>VFIF</sub></i> = 0, then upper limit = <i>V</i><i><sub>RMX</sub></i> and lower limit = <i>V</i><i><sub>RMN</sub></i><i>;</i> - If <i>K</i><i><sub>VFIF</sub></i> = 1 ,then upper limit = <i>I</i><i><sub>FMX</sub></i><i> </i>and lower limit = <i>I</i><i><sub>FMN</sub></i>.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:13:332022-03-18 22:34:11
CHANGED{15CFECD8-BB7C-411f-ABA7-FC5E511A21E3}
Diagram notes
This diagram describes the ExcANS excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>Limits on <i>V</i><i><sub>R</sub></i> signal are modelled as follows: </li> </ol> - If <i>K</i><i><sub>VFIF</sub></i> = 0, then upper limit = <i>V</i><i><sub>RMX</sub></i> and lower limit = <i>V</i><i><sub>RMN</sub></i><i>;</i> - If <i>K</i><i><sub>VFIF</sub></i> = 1 ,then upper limit = <i>I</i><i><sub>FMX</sub></i><i> </i>and lower limit = <i>I</i><i><sub>FMN</sub></i>.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:13:332022-03-18 22:34:11
Diagram 'ExcANS' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR1i
Diagram notes
This diagram describes the ExcAVR1 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:13:512022-03-18 22:34:02
CHANGED{B0B7BEC4-C784-4c2e-B710-4D66EF98A320}
Diagram notes
This diagram describes the ExcAVR1 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:13:512022-03-18 22:34:02
Diagram 'ExcAVR1' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR2i
Diagram notes
This diagram describes the ExcAVR2 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:14:112022-03-18 22:33:55
CHANGED{38AC243E-0F9D-4ece-9B18-292829E90E58}
Diagram notes
This diagram describes the ExcAVR2 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:14:112022-03-18 22:33:55
Diagram 'ExcAVR2' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR3i
Diagram notes
This diagram describes the ExcAVR3 excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The non-windup limit is defined as in Annex E of the IEEE 421.5-2005.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:14:232022-03-18 22:33:46
CHANGED{E82ACE42-FC34-4a42-821B-D8B3EC6E3BA1}
Diagram notes
This diagram describes the ExcAVR3 excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The non-windup limit is defined as in Annex E of the IEEE 421.5-2005.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:14:232022-03-18 22:33:46
Diagram 'ExcAVR3' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR4i
Diagram notes
This diagram describes the ExcAVR4 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:14:382022-03-18 22:33:38
CHANGED{9B65BF31-7D3B-414d-B810-F937938AC002}
Diagram notes
This diagram describes the ExcAVR4 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:14:382022-03-18 22:33:38
Diagram 'ExcAVR4' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR5i
Diagram notes
This diagram describes the ExcAVR5 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:14:532022-03-18 22:33:30
CHANGED{30CE3FE3-AFB3-4e5c-84FC-4FB1A25D9EEB}
Diagram notes
This diagram describes the ExcAVR5 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:14:532022-03-18 22:33:30
Diagram 'ExcAVR5' has no other changes. The shows its notes and every changed property.
▶▦ExcAVR7i
Diagram notes
This diagram describes the ExcAVR7 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:15:072022-03-18 22:33:22
CHANGED{43697363-C097-46b6-93A8-B903638297B5}
Diagram notes
This diagram describes the ExcAVR7 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:15:072022-03-18 22:33:22
Diagram 'ExcAVR7' has no other changes. The shows its notes and every changed property.
▶▦ExcBBCi
Diagram notes
This diagram describes the ExcBBC excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 22:35:482022-03-18 22:33:12
CHANGED{9E2BAC52-C5ED-4a81-AE4B-9D7350B5C14B}
Diagram notes
This diagram describes the ExcBBC excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 22:35:482022-03-18 22:33:12
Diagram 'ExcBBC' has no other changes. The shows its notes and every changed property.
▶▦ExcCZi
Diagram notes
This diagram describes the ExcCZ excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:15:432022-03-18 22:33:04
CHANGED{8DD3C94B-B3D0-497c-BF71-FE5154E95615}
Diagram notes
This diagram describes the ExcCZ excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:15:432022-03-18 22:33:04
Diagram 'ExcCZ' has no other changes. The shows its notes and every changed property.
▶▦ExcDC1Ai
Diagram notes
This diagram describes the ExcDC1A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:15:582022-03-18 22:32:56
CHANGED{079C2FF0-9728-42b1-B677-7EE770450233}
Diagram notes
This diagram describes the ExcDC1A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:15:582022-03-18 22:32:56
Diagram 'ExcDC1A' has no other changes. The shows its notes and every changed property.
▶▦ExcDC2Ai
Diagram notes
This diagram describes the ExcDC2A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:16:152022-03-18 22:32:46
CHANGED{D82BC07E-C76A-44de-8A13-6465138B2B25}
Diagram notes
This diagram describes the ExcDC2A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:16:152022-03-18 22:32:46
Diagram 'ExcDC2A' has no other changes. The shows its notes and every changed property.
▶▦ExcDC3Ai
Diagram notes
This diagram describes the ExcDC3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>If <i>Kr</i> is not zero, the voltage regulator input changes at a constant rate if <i>Verr</i> > <i>Kr</i> or <i>Verr</i> < -<i>Kr</i> as per the IEEE (1968) type 4 model. If <i>Kr</i> is zero, the error signal drives the voltage regulator continuously as per the IEEE (1980) DC3 and IEEE (1992, 2005) DC3A models.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:16:282022-03-18 22:32:37
CHANGED{43D1448F-FB4F-4b65-A517-FDB942FE9EE2}
Diagram notes
This diagram describes the ExcDC3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>If <i>Kr</i> is not zero, the voltage regulator input changes at a constant rate if <i>Verr</i> > <i>Kr</i> or <i>Verr</i> < -<i>Kr</i> as per the IEEE (1968) type 4 model. If <i>Kr</i> is zero, the error signal drives the voltage regulator continuously as per the IEEE (1980) DC3 and IEEE (1992, 2005) DC3A models.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:16:282022-03-18 22:32:37
Diagram 'ExcDC3A' has no other changes. The shows its notes and every changed property.
▶▦ExcDC3A1i
Diagram notes
This diagram describes the ExcDC3A1 excitation system model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd</i> (<i>XadIfd</i>) and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to <i>Efd</i> in steady-state. </font></li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:16:472022-03-18 22:32:29
CHANGED{AA3DFB09-725D-4405-970C-7ECAE1C93F70}
Diagram notes
This diagram describes the ExcDC3A1 excitation system model<font color="#0f0f0f">.</font> <font color="#0f0f0f">Parameter details:</font> <ol> <li><font color="#0f0f0f"><i>Ifd</i> represents <i>LadIfd</i> (<i>XadIfd</i>) and is a voltage proportional to field current in PU (IEEE 421.5-2005, Annex B). It is equal to <i>Efd</i> in steady-state. </font></li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:16:472022-03-18 22:32:29
Diagram 'ExcDC3A1' has no other changes. The shows its notes and every changed property.
▶▦ExcELIN1i
Diagram notes
This diagram describes the ExcELIN1 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:17:092022-03-18 22:32:20
CHANGED{890E0026-DDF2-4caf-9242-A4D792DE4EE4}
Diagram notes
This diagram describes the ExcELIN1 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:17:092022-03-18 22:32:20
Diagram 'ExcELIN1' has no other changes. The shows its notes and every changed property.
▶▦ExcELIN2i
Diagram notes
This diagram describes the ExcELIN2 excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:17:232022-03-18 22:32:11
CHANGED{F6EE912B-684B-498f-9F83-185BF250D88A}
Diagram notes
This diagram describes the ExcELIN2 excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:17:232022-03-18 22:32:11
Diagram 'ExcELIN2' has no other changes. The shows its notes and every changed property.
▶▦ExcHUi
Diagram notes
This diagram describes the ExcHU excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:17:432022-03-18 22:32:02
CHANGED{856E7EF3-AA22-4307-B5EE-21BBD30633EE}
Diagram notes
This diagram describes the ExcHU excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:17:432022-03-18 22:32:02
Diagram 'ExcHU' has no other changes. The shows its notes and every changed property.
▶▦ExcitationSystemDynamicsi
Diagram notes
This diagram shows dynamic standard model excitation system classes and their inheritance from the ExcitationSystemDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 21:49:402022-03-18 22:35:28
CHANGED{6F433799-BA80-4d4a-ABD1-BD898279F311}
Diagram notes
This diagram shows dynamic standard model excitation system classes and their inheritance from the ExcitationSystemDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 21:49:402022-03-18 22:35:28
▦Diagram
addedremovedchangedmoved or resized
Baseline
ExcitationSystemDynamics (baseline)
Destination
ExcitationSystemDynamics (destination)
Connectors 19 removed · 31 reroutedhover a connector to outline the elements it joins
removedExcIEEEAC1A – ExcitationSystemDynamics
removedExcIEEEAC2A – ExcitationSystemDynamics
removedExcIEEEAC3A – ExcitationSystemDynamics
removedExcIEEEAC4A – ExcitationSystemDynamics
removedExcIEEEAC5A – ExcitationSystemDynamics
removedExcIEEEAC6A – ExcitationSystemDynamics
removedExcIEEEAC7B – ExcitationSystemDynamics
removedExcIEEEAC8B – ExcitationSystemDynamics
removedExcIEEEDC1A – ExcitationSystemDynamics
removedExcIEEEDC2A – ExcitationSystemDynamics
removedExcIEEEDC3A – ExcitationSystemDynamics
removedExcIEEEDC4B – ExcitationSystemDynamics
removedExcIEEEST1A – ExcitationSystemDynamics
removedExcIEEEST2A – ExcitationSystemDynamics
removedExcIEEEST3A – ExcitationSystemDynamics
removedExcIEEEST4B – ExcitationSystemDynamics
removedExcIEEEST5B – ExcitationSystemDynamics
removedExcIEEEST6B – ExcitationSystemDynamics
removedExcIEEEST7B – ExcitationSystemDynamics
reroutedExcAC1A – ExcitationSystemDynamics
reroutedExcAC2A – ExcitationSystemDynamics
reroutedExcAC3A – ExcitationSystemDynamics
reroutedExcAC4A – ExcitationSystemDynamics
reroutedExcAC5A – ExcitationSystemDynamics
reroutedExcAC6A – ExcitationSystemDynamics
reroutedExcAC8B – ExcitationSystemDynamics
reroutedExcANS – ExcitationSystemDynamics
reroutedExcAVR1 – ExcitationSystemDynamics
reroutedExcAVR2 – ExcitationSystemDynamics
reroutedExcAVR3 – ExcitationSystemDynamics
reroutedExcAVR4 – ExcitationSystemDynamics
reroutedExcAVR5 – ExcitationSystemDynamics
reroutedExcAVR7 – ExcitationSystemDynamics
reroutedExcBBC – ExcitationSystemDynamics
reroutedExcCZ – ExcitationSystemDynamics
reroutedExcDC1A – ExcitationSystemDynamics
reroutedExcDC3A1 – ExcitationSystemDynamics
reroutedExcELIN1 – ExcitationSystemDynamics
reroutedExcELIN2 – ExcitationSystemDynamics
reroutedExcHU – ExcitationSystemDynamics
reroutedExcNI – ExcitationSystemDynamics
reroutedExcRQB – ExcitationSystemDynamics
reroutedExcSEXS – ExcitationSystemDynamics
reroutedExcSK – ExcitationSystemDynamics
reroutedExcST1A – ExcitationSystemDynamics
reroutedExcST2A – ExcitationSystemDynamics
reroutedExcST3A – ExcitationSystemDynamics
reroutedExcST6B – ExcitationSystemDynamics
reroutedExcitationSystemDynamics – DynamicsFunctionBlock
reroutedExcitationSystemUserDefined – ExcitationSystemDynamics
▶▦ExcitationSystemInterconnectionAndVariablesi
Diagram notes
This diagram illustrates the inputs and outputs for an excitation system model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-17 15:43:272022-03-18 22:35:34
CHANGED{A03B567E-57DC-4a87-B4B8-F6B175D57DDB}
Diagram notes
This diagram illustrates the inputs and outputs for an excitation system model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-17 15:43:272022-03-18 22:35:34
Diagram 'ExcitationSystemInterconnectionAndVariables' has no other changes. The shows its notes and every changed property.
▶▦ExcNIi
Diagram notes (destination, redlined)
This diagram describes the ExcNI excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li><i>R</i> shall either be = 0 (meaning the exciter has negative current capability) or > 0 (meaning the exciter has no negative current capability).</li> <li>The 'Negative Current Logic' block logic uses the <i>R</i> parameter and the <i>Efdn</i> and <i>Ifd</i> inputs. The output <i>Efd</i> is set equal to the input <i>Efdn</i> unless <i>-R</i> x <i>Ifd</i> > 0 and <i>-R</i> x <i>Ifd</i> > <i>Efdn,</i> in which case <i>Efd</i> is set equal to <i>-R</i> x <i>Ifd</i>. This means that the negative current logic is active (<i>R</i> and <i>Ifd</i> are used to calculate <i>Efd</i>) only when the current is positive and the exciter does not have current capability (iExcNI.e. when ExcNi.r is greater than 0).</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-10 09:52:272022-03-18 22:31:53
CHANGED{64148D65-5ACF-4af1-A567-A1984765ED08}
Diagram notes (destination, redlined)
This diagram describes the ExcNI excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li><i>R</i> shall either be = 0 (meaning the exciter has negative current capability) or > 0 (meaning the exciter has no negative current capability).</li> <li>The 'Negative Current Logic' block logic uses the <i>R</i> parameter and the <i>Efdn</i> and <i>Ifd</i> inputs. The output <i>Efd</i> is set equal to the input <i>Efdn</i> unless <i>-R</i> x <i>Ifd</i> > 0 and <i>-R</i> x <i>Ifd</i> > <i>Efdn,</i> in which case <i>Efd</i> is set equal to <i>-R</i> x <i>Ifd</i>. This means that the negative current logic is active (<i>R</i> and <i>Ifd</i> are used to calculate <i>Efd</i>) only when the current is positive and the exciter does not have current capability (iExcNI.e. when ExcNi.r is greater than 0).</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-10-10 09:52:272022-03-18 22:31:53
Diagram 'ExcNI' has no other changes. The shows its notes and every changed property.
▶▦ExcOEX3Ti
Diagram notes
This diagram describes the ExcOEX3T excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:18:302022-03-18 22:31:44
CHANGED{72266274-4F94-4536-B1F9-C830B43505DB}
Diagram notes
This diagram describes the ExcOEX3T excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:18:302022-03-18 22:31:44
Diagram 'ExcOEX3T' has no other changes. The shows its notes and every changed property.
▶▦ExcPICi
Diagram notes
This diagram describes the ExcPIC excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:18:452022-03-18 22:31:34
CHANGED{0F86E828-A6F9-448b-A053-0CDAEA5B8765}
Diagram notes
This diagram describes the ExcPIC excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:18:452022-03-18 22:31:34
Diagram 'ExcPIC' has no other changes. The shows its notes and every changed property.
▶▦ExcREXSi
Diagram notes (destination, redlined)
This diagram describes the ExcREXS excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The rotating exciter can be of either DC or brushless AC type. To model a DC exciter, set <i>Kc</i> = <i>Kd </i>= 0.</li> <li>An AC exciter can be modelled either by setting <i>Kc</i> and <i>Kd</i> to non- zero values to represent the armature reaction of the exciter and the regulation of the rotating rectifier, respectively, or by specifying the saturation factors, <i>Se1</i> and <i>Se2</i>, to represent the excitation-output-voltage curve of the exciter as loaded by the field resistance of the main generator. It is preferable to use the first approach (<i>Kd</i> = 0) since the later approach does not represent the effect of armature reaction in the exciter on its field current and hence invalidates the model when field current is sensed by the voltage regulator.</li> <li>When this model is used to represent a separately-excited exciter, the value of <i>Ke</i> should normally be close to unity. A shunt-excited DC exciter can be modelled by setting <i>Ke</i> to the appropriate small negative value needed to represent the relationship between the exciter's air gap line and field resistance line. Note, though, that this model does not determine the value of <i>Ke</i> automatically when a shunt field DC exciter is being represented</li> <li>The voltage regulator can be of proportional or proportional-plus-integral form. Either <i>Kvp</i> or <i>Kvi</i>, but not both, can be zero.</li> <li>The voltage regulator output can be either the field voltage applied directly to the exciter or the input to an exciter field current regulator by choice of values of <i>Kip</i>,<i> Kii</i>, and <i>Kh</i>. Either or both of <i>Kip</i> and <i>Kii</i> shall be non-zero. If <i>Kii</i> is non-zero, <i>Kh</i> should normally be non-zero.</li> <li>The voltage regulator reference is modified by a volts-per-hertz limiter when shaft speed falls below <i>Nvphz</i>. When the shaft speed is below <i>Nvphz</i> the regulator reference is reduced as follows: effective <i>Vref </i>= <i>Vref</i> (1,0 – <i>Kvphz</i> (speed - <i>Nvphz-</i>speed)) The volts-per-hertz limiter can be disabled by setting <i>Nvphz</i> = 0 or <i>Kvphz</i> = 0.</li> <li>Saturation parameters are given by the IEEE saturation factor definition using the open circuit magnetization of the exciter. Either point [<i>E</i><i><sub>1</sub></i>, <i>S</i>(<i>E</i><i><sub>1</sub></i>) or <i>E</i><i><sub>2</sub></i>, S(<i>E</i><i><sub>2</sub></i>)] can be the higher value and the other the lower.</li> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>The voltage regulator output limits, <i>Vrmax</i> and <i>Vrmin</i>, shall be stated as multiples of the value of exciter field current needed to maintain the exciter output at its base value. The field current limit, <i>Vlr</i>, shall be stated as a multiple of the exciter field current needed to maintain the exciter output at its base value. That is, <i>Vrmax</i> and <i>Vrmin</i> shall be stated in terms of the PU exciter output voltage to which they correspond in the steady state.</li> <li>The regulator output limit flag indicates whether the control power supply for the voltage regulator is a transformer at the generator terminals or an independent source such as a permanent magnet generator. Set <i>Flimf</i> as follows:</li> </ol> - <i>Flimf</i> = 0 the limits on regulator output are <i>Vrmax</i>, <i>Vrmin</i>, <i>Vfmax</i> and <i>Vfmin</i>; - <i>Flimf</i> = 1 the limits on regulator output are (<i>Vrmax</i> x <i>Vterm</i>), (<i>Vrmin</i> x <i>Vterm</i>), (<i>Vfmax</i> x <i>Vterm</i>), and (<i>Vfmin</i> x <i>Vterm</i>). 12. Feedback signal selector uses ExcREXSFeedbackSignalKind, where: - 0 (AVR output signal) = ExcREXSFeedbackSignalKind.fieldVoltage; - 1 (exciter field current) = ExcREXSFeedbackSignalKind.fieldCurent; - 2 (exciter output voltage) = ExcREXSFeedbackSignalKind.outputVoltage.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-10-07 23:56:242022-03-18 22:31:26
CHANGED{7C23360B-2285-4410-990B-D57FBA1603F1}
Diagram notes (destination, redlined)
This diagram describes the ExcREXS excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>The rotating exciter can be of either DC or brushless AC type. To model a DC exciter, set <i>Kc</i> = <i>Kd </i>= 0.</li> <li>An AC exciter can be modelled either by setting <i>Kc</i> and <i>Kd</i> to non- zero values to represent the armature reaction of the exciter and the regulation of the rotating rectifier, respectively, or by specifying the saturation factors, <i>Se1</i> and <i>Se2</i>, to represent the excitation-output-voltage curve of the exciter as loaded by the field resistance of the main generator. It is preferable to use the first approach (<i>Kd</i> = 0) since the later approach does not represent the effect of armature reaction in the exciter on its field current and hence invalidates the model when field current is sensed by the voltage regulator.</li> <li>When this model is used to represent a separately-excited exciter, the value of <i>Ke</i> should normally be close to unity. A shunt-excited DC exciter can be modelled by setting <i>Ke</i> to the appropriate small negative value needed to represent the relationship between the exciter's air gap line and field resistance line. Note, though, that this model does not determine the value of <i>Ke</i> automatically when a shunt field DC exciter is being represented</li> <li>The voltage regulator can be of proportional or proportional-plus-integral form. Either <i>Kvp</i> or <i>Kvi</i>, but not both, can be zero.</li> <li>The voltage regulator output can be either the field voltage applied directly to the exciter or the input to an exciter field current regulator by choice of values of <i>Kip</i>,<i> Kii</i>, and <i>Kh</i>. Either or both of <i>Kip</i> and <i>Kii</i> shall be non-zero. If <i>Kii</i> is non-zero, <i>Kh</i> should normally be non-zero.</li> <li>The voltage regulator reference is modified by a volts-per-hertz limiter when shaft speed falls below <i>Nvphz</i>. When the shaft speed is below <i>Nvphz</i> the regulator reference is reduced as follows: effective <i>Vref </i>= <i>Vref</i> (1,0 – <i>Kvphz</i> (speed - <i>Nvphz-</i>speed)) The volts-per-hertz limiter can be disabled by setting <i>Nvphz</i> = 0 or <i>Kvphz</i> = 0.</li> <li>Saturation parameters are given by the IEEE saturation factor definition using the open circuit magnetization of the exciter. Either point [<i>E</i><i><sub>1</sub></i>, <i>S</i>(<i>E</i><i><sub>1</sub></i>) or <i>E</i><i><sub>2</sub></i>, S(<i>E</i><i><sub>2</sub></i>)] can be the higher value and the other the lower.</li> <li>If <i>Ks</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> <li>The voltage regulator output limits, <i>Vrmax</i> and <i>Vrmin</i>, shall be stated as multiples of the value of exciter field current needed to maintain the exciter output at its base value. The field current limit, <i>Vlr</i>, shall be stated as a multiple of the exciter field current needed to maintain the exciter output at its base value. That is, <i>Vrmax</i> and <i>Vrmin</i> shall be stated in terms of the PU exciter output voltage to which they correspond in the steady state.</li> <li>The regulator output limit flag indicates whether the control power supply for the voltage regulator is a transformer at the generator terminals or an independent source such as a permanent magnet generator. Set <i>Flimf</i> as follows:</li> </ol> - <i>Flimf</i> = 0 the limits on regulator output are <i>Vrmax</i>, <i>Vrmin</i>, <i>Vfmax</i> and <i>Vfmin</i>; - <i>Flimf</i> = 1 the limits on regulator output are (<i>Vrmax</i> x <i>Vterm</i>), (<i>Vrmin</i> x <i>Vterm</i>), (<i>Vfmax</i> x <i>Vterm</i>), and (<i>Vfmin</i> x <i>Vterm</i>). 12. Feedback signal selector uses ExcREXSFeedbackSignalKind, where: - 0 (AVR output signal) = ExcREXSFeedbackSignalKind.fieldVoltage; - 1 (exciter field current) = ExcREXSFeedbackSignalKind.fieldCurent; - 2 (exciter output voltage) = ExcREXSFeedbackSignalKind.outputVoltage.
▤Metadata
BaselineDestination
ModifiedDate2017-10-07 23:56:242022-03-18 22:31:26
Diagram 'ExcREXS' has no other changes. The shows its notes and every changed property.
▶▦ExcRQBi
Diagram notes
This diagram describes the ExcRQB excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:19:182022-03-18 22:31:17
CHANGED{B8ABA46B-D9D5-4abf-85B9-BD7D1869F431}
Diagram notes
This diagram describes the ExcRQB excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:19:182022-03-18 22:31:17
Diagram 'ExcRQB' has no other changes. The shows its notes and every changed property.
▶▦ExcSCRXi
Diagram notes
This diagram describes the ExcSCRX excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:19:362022-03-18 22:31:06
CHANGED{FC510C0C-1A80-4e1e-B573-FE4B87CAF1F5}
Diagram notes
This diagram describes the ExcSCRX excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:19:362022-03-18 22:31:06
Diagram 'ExcSCRX' has no other changes. The shows its notes and every changed property.
▶▦ExcSEXSi
Diagram notes
This diagram describes the ExcSEXS excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:19:532022-03-18 22:30:58
CHANGED{BC17B401-6BE7-48d9-B52C-9F035170999B}
Diagram notes
This diagram describes the ExcSEXS excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:19:532022-03-18 22:30:58
Diagram 'ExcSEXS' has no other changes. The shows its notes and every changed property.
▶▦ExcSKi
Diagram notes (destination, redlined)
This diagram describes the ExcSK excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li><i>Qmax</i> is calculated using this equation: <i>Qmax</i> = <i>K1</i> x <i>Pgen</i> + <i>K2</i>. If the input is below Qmax then the output is 0. Above Qmax output is equal to input.</li> <li><i>Pgen</i> and <i>Qgen</i> are in PU.</li> <li>The part of the model which includes <i>Qmax</i> and <i>Kqob</i> represents back-coupling from the reactive power with statics. It is used for parallel co-operationcooperation with other generators to share the reactive power demand. This can be neglected if the configuration is a single generating unit.</li> <li>The block <i>Fex </i>(<i>In</i>) is modelled as described in IEEE 421.5 - part on rectifier regulation equations.</li> <li><i>Qz</i> is desired value (setpoint) of reactive power, manual setting. </li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:20:132022-03-18 22:30:48
CHANGED{3BA85CB0-C58C-4b53-B054-B765F551A661}
Diagram notes (destination, redlined)
This diagram describes the ExcSK excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li><i>Qmax</i> is calculated using this equation: <i>Qmax</i> = <i>K1</i> x <i>Pgen</i> + <i>K2</i>. If the input is below Qmax then the output is 0. Above Qmax output is equal to input.</li> <li><i>Pgen</i> and <i>Qgen</i> are in PU.</li> <li>The part of the model which includes <i>Qmax</i> and <i>Kqob</i> represents back-coupling from the reactive power with statics. It is used for parallel co-operationcooperation with other generators to share the reactive power demand. This can be neglected if the configuration is a single generating unit.</li> <li>The block <i>Fex </i>(<i>In</i>) is modelled as described in IEEE 421.5 - part on rectifier regulation equations.</li> <li><i>Qz</i> is desired value (setpoint) of reactive power, manual setting. </li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:20:132022-03-18 22:30:48
Diagram 'ExcSK' has no other changes. The shows its notes and every changed property.
▶▦ExcST1Ai
Diagram notes
This diagram describes the ExcST1A excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:20:282022-03-18 22:30:37
CHANGED{4FF6B612-3C04-4747-9D62-867CFAC109C4}
Diagram notes
This diagram describes the ExcST1A excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:20:282022-03-18 22:30:37
Diagram 'ExcST1A' has no other changes. The shows its notes and every changed property.
▶▦ExcST2Ai
Diagram notes
This diagram describes the ExcST2A excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:20:512022-03-18 22:30:28
CHANGED{118AA31A-AE70-4964-80A6-B3D836198F8B}
Diagram notes
This diagram describes the ExcST2A excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:20:512022-03-18 22:30:28
Diagram 'ExcST2A' has no other changes. The shows its notes and every changed property.
▶▦ExcST3Ai
Diagram notes
This diagram describes the ExcST3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> or <i>Ks1</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:21:032022-03-18 22:30:19
CHANGED{FF518C60-CFD3-4964-96D3-686F791C5AF1}
Diagram notes
This diagram describes the ExcST3A excitation system model<font color="#0f0f0f">.</font> Parameter details: <ol> <li>If <i>Ks</i> or <i>Ks1</i> is set to 1, the output (<i>Efd</i>) is multiplied by generator speed.</li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:21:032022-03-18 22:30:19
Diagram 'ExcST3A' has no other changes. The shows its notes and every changed property.
▶▦ExcST4Bi
Diagram notes
This diagram describes the ExcST4B excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:21:242022-03-18 22:30:10
CHANGED{005CC727-92C5-4707-9813-1ABE30290D65}
Diagram notes
This diagram describes the ExcST4B excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:21:242022-03-18 22:30:10
Diagram 'ExcST4B' has no other changes. The shows its notes and every changed property.
▶▦ExcST6Bi
Diagram notes
This diagram describes the ExcST6B excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:21:382022-03-18 22:30:01
CHANGED{5A638E62-61F9-4fe4-9C3F-930ACD77CA31}
Diagram notes
This diagram describes the ExcST6B excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:21:382022-03-18 22:30:01
Diagram 'ExcST6B' has no other changes. The shows its notes and every changed property.
▶▦ExcST7Bi
Diagram notes
This diagram describes the ExcST7B excitation system model<font color="#0f0f0f">.</font>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:21:532022-03-18 22:29:52
CHANGED{B38C483B-48BF-4c70-8974-BBA53061683C}
Diagram notes
This diagram describes the ExcST7B excitation system model<font color="#0f0f0f">.</font>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:21:532022-03-18 22:29:52
Diagram 'ExcST7B' has no other changes. The shows its notes and every changed property.
▶OverexcitationLimiterDynamicsi
Package notes
Overexcitation limiters (OELs) are also referred to as <i>maximum excitation limiters </i>and <i>field current limiters. </i>The possibility of voltage collapse in stressed power systems increases the importance of modelling these limiters in studies of system conditions that cause machines to operate at high levels of excitation for a sustained period, such as voltage collapse or system-islanding. Such events typically occur over a long time frame compared with transient or small-signal stability simulations.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/OverexcitationLimiterDynamics/1.0
version(no tag)1.0.0
CHANGED{CB5C7172-23DD-4cc0-ACF3-557E0496AFCD}
Package notes
Overexcitation limiters (OELs) are also referred to as <i>maximum excitation limiters </i>and <i>field current limiters. </i>The possibility of voltage collapse in stressed power systems increases the importance of modelling these limiters in studies of system conditions that cause machines to operate at high levels of excitation for a sustained period, such as voltage collapse or system-islanding. Such events typically occur over a long time frame compared with transient or small-signal stability simulations.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/OverexcitationLimiterDynamics/1.0
version(no tag)1.0.0
Added classes (4)
▶⚙OverexcLimIEEEOEL2Ci
Class notes
IEEE 421.5-2016 OEL2C overexcitation limiter model. This model is an extension of the OEL model proposed by the IEEE Task Force on Excitation Limiters. This model allows the representation of different OEL actions, such as instantaneous and inverse-time responses. Also, the timed response could follow fixed ramp rates (definite time response) or use ramp rates proportional to the level of overexcitation. Furthermore, this model can represent summation point or takeover OEL implementations. Reference: IEEE 421.5-2016, 10.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL2C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{A375B175-ED01-483b-81FE-9C356923B9BD}
Class notes
IEEE 421.5-2016 OEL2C overexcitation limiter model. This model is an extension of the OEL model proposed by the IEEE Task Force on Excitation Limiters. This model allows the representation of different OEL actions, such as instantaneous and inverse-time responses. Also, the timed response could follow fixed ramp rates (definite time response) or use ramp rates proportional to the level of overexcitation. Furthermore, this model can represent summation point or takeover OEL implementations. Reference: IEEE 421.5-2016, 10.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL2C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
c1i{AD2CBCA5-7A4B-4842-BA35-21AB87A70FFC}show detailsdid not existFloat [0..1]OEL exponent for calculation of IERRinv1 (c1). Typical value = 0.
Attribute notes
OEL exponent for calculation of IERRinv1 (c1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namec1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
c2i{C9AB0DBE-82D3-4968-BA08-5C665741F167}show detailsdid not existFloat [0..1]OEL exponent for calculation of IERRinv2 (c2). Typical value = 2.
Attribute notes
OEL exponent for calculation of IERRinv2 (c2). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namec2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
fixedrdi{57810B81-14BF-44b0-9A48-34F8C5421CC7}show detailsdid not existPU [0..1]OEL fixed cooling-down time output (Fixedrd). Typical value = -0,001.
Attribute notes
OEL fixed cooling-down time output (Fixedrd). Typical value = -0,001.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefixedrd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
fixedrui{F17AFD73-9212-4077-80AA-A9979D6C4703}show detailsdid not existPU [0..1]OEL fixed delay time output (Fixedru). Typical value = 0.
Attribute notes
OEL fixed delay time output (Fixedru). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namefixedru
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdratedi{310BBF0B-E747-4dc3-9614-79E4D2C10CD8}show detailsdid not existPU [0..1]Rated field current (Ifdrated). Typical value = 3.
Attribute notes
Rated field current (Ifdrated). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdrated
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
iinsti{34E3BEF4-0464-42ad-A451-35CF483E8569}show detailsdid not existPU [0..1]OEL instantaneous field current limit (Iinst). Typical value = 6.
Attribute notes
OEL instantaneous field current limit (Iinst). Typical value = 6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameiinst
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ilimi{3262A539-2145-4fbd-8BD2-D31AFCC3F408}show detailsdid not existPU [0..1]OEL thermal field current limit (Ilim). Typical value = 3.
Attribute notes
OEL thermal field current limit (Ilim). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameilim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ireseti{B3005521-5B35-43fb-BED7-7C9AE0221ABE}show detailsdid not existPU [0..1]OEL reset-reference, if OEL is inactive (Ireset). Typical value = 100.
Attribute notes
OEL reset-reference, if OEL is inactive (Ireset). Typical value = 100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameireset
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
itfpui{8D203064-82AF-4905-A690-2994EDC3FB50}show detailsdid not existPU [0..1]OEL reference for inverse time calculations (Itfpu). Typical value = 3.
Attribute notes
OEL reference for inverse time calculations (Itfpu). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameitfpu
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ithoffi{1B0FFFF1-9EF2-4425-BA3E-7A4C70188FD6}show detailsdid not existPU [0..1]OEL reset threshold value (Ithoff). Typical value = 0,05.
Attribute notes
OEL reset threshold value (Ithoff). Typical value = 0,05.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameithoff
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k1i{8EEF4289-669C-4f5e-9BA4-EF5249E33D37}show detailsdid not existPU [0..1]OEL gain for calculation of IERRinv1 (K1). Typical value = 0.
Attribute notes
OEL gain for calculation of IERRinv1 (K1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k2i{812F4E4F-9F81-4f81-AF3B-60725DA8CD4A}show detailsdid not existPU [0..1]OEL gain for calculation of IERRinv2 (K2). Typical value = 0,0296.
Attribute notes
OEL gain for calculation of IERRinv2 (K2). Typical value = 0,0296.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kacti{C3106329-CD16-4056-93C0-32B47414F094}show detailsdid not existPU [0..1]OEL actual value scaling factor (Kact). Typical value = 1.
Attribute notes
OEL actual value scaling factor (Kact). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekact
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kdoeli{5C9E59A9-18C8-43b7-9CBD-41D9000C0DB1}show detailsdid not existPU [0..1]OEL PID regulator differential gain (Kdoel). Typical value = 0.
Attribute notes
OEL PID regulator differential gain (Kdoel). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekdoel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfbi{7DC2E081-0F30-4a8f-B1ED-5067D36A8ACA}show detailsdid not existPU [0..1]OEL timer feedback gain (Kfb). Typical value = 0.
Attribute notes
OEL timer feedback gain (Kfb). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekfb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kioeli{FA21EF9F-11C9-40f6-B60A-462E7A7EB04E}show detailsdid not existPU [0..1]OEL PID regulator integral gain (Kioel). Typical value = 0.
Attribute notes
OEL PID regulator integral gain (Kioel). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekioel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpoeli{9A907AB2-1D7E-4e59-956B-06BD73A1CBBC}show detailsdid not existPU [0..1]OEL PID regulator proportional gain (Kpoel). Typical value = 0,5.
Attribute notes
OEL PID regulator proportional gain (Kpoel). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpoel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
krdi{623051B2-47D4-4d0c-9DD1-0F34FFF073A3}show detailsdid not existPU [0..1]OEL reference ramp-down rate (Krd). Typical value = -1000.
Attribute notes
OEL reference ramp-down rate (Krd). Typical value = -1000.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekrd
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
krui{A0C0F876-7A38-4746-B0F3-C8F8E5E77017}show detailsdid not existPU [0..1]OEL reference ramp-up rate (Kru). Typical value = 1000.
Attribute notes
OEL reference ramp-up rate (Kru). Typical value = 1000.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekru
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kscalei{0D8E4DBA-CC8F-4e8f-B663-40EDF396D131}show detailsdid not existPU [0..1]OEL input signal scaling factor (Kscale). Typical value = 1.
Attribute notes
OEL input signal scaling factor (Kscale). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekscale
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kzrui{B8AF243C-AD9A-40c1-A17B-73D78512B605}show detailsdid not existFloat [0..1]OEL thermal reference release threshold (Kzru). Typical value = 0,99.
Attribute notes
OEL thermal reference release threshold (Kzru). Typical value = 0,99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekzru
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
taoeli{FE1CD88B-98E5-41f0-875A-44DCAD9441D8}show detailsdid not existSeconds [0..1]OEL reference filter time constant (Taoel) (>=0). Typical value = 0,04.
Attribute notes
OEL reference filter time constant (Taoel) (>=0). Typical value = 0,04.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametaoel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb1oeli{89C0C195-0293-468c-B690-C411398E44CE}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant 1 (Tb1oel) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator numerator (lead) time constant 1 (Tb1oel) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb1oel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tb2oeli{635C432D-CE8A-4053-864C-73336883044A}show detailsdid not existSeconds [0..1]OEL regulator numerator (lead) time constant 2 (Tb2oel) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator numerator (lead) time constant 2 (Tb2oel) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametb2oel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc1oeli{381EDB07-2D6A-43c5-9423-6B76FC48D01A}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant 1 (Tc1oel) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator denominator (lag) time constant 1 (Tc1oel) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc1oel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tc2oeli{CD7C14E3-F4F6-46e1-A770-939544EEFB9F}show detailsdid not existSeconds [0..1]OEL regulator denominator (lag) time constant 2 (Tc2oel) (>=0). Typical value = 0,1.
Attribute notes
OEL regulator denominator (lag) time constant 2 (Tc2oel) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametc2oel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tdoeli{5E930841-7DDC-4e7a-B81D-5626F328C5ED}show detailsdid not existSeconds [0..1]OEL PID regulator differential time constant (Tdoel) (>=0). Typical value = 0,1.
Attribute notes
OEL PID regulator differential time constant (Tdoel) (>=0). Typical value = 0,1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdoel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
teni{CB14A368-27DD-44bb-AC41-93093215B984}show detailsdid not existSeconds [0..1]OEL activation delay time (Ten) (>=0). Typical value = 0,2.
Attribute notes
OEL activation delay time (Ten) (>=0). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameten
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tfcli{FB474979-88BC-4a13-91F5-72064A467FF3}show detailsdid not existPU [0..1]OEL timer reference (Tfcl). Typical value = 10.
Attribute notes
OEL timer reference (Tfcl). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametfcl
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tmaxi{2290FB36-767E-4c91-9D16-6A8E7BC45C99}show detailsdid not existPU [0..1]OEL timer maximum level (Tmax). Typical value = 10.
Attribute notes
OEL timer maximum level (Tmax). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tmini{6FD39FDF-B4DE-41c6-BBFC-05039890AB98}show detailsdid not existPU [0..1]OEL timer minimum level (Tmin). Typical value = 0.
Attribute notes
OEL timer minimum level (Tmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
toffi{CB1841B7-0BC7-448b-832C-F23B9CBB9E1E}show detailsdid not existSeconds [0..1]OEL reset delay time (Toff) (>=0). Typical value = 5.
Attribute notes
OEL reset delay time (Toff) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoff
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
troeli{713BC35A-A032-4734-BD5F-2F507A308404}show detailsdid not existSeconds [0..1]OEL input signal filter time constant (Troel) (>=0). Typical value = 0,01.
Attribute notes
OEL input signal filter time constant (Troel) (>=0). Typical value = 0,01.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametroel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vinvmaxi{C8C588ED-EB8E-4b3f-A5AE-AB765C735F02}show detailsdid not existPU [0..1]OEL maximum inverse time output (Vinvmax). Typical value = 100.
Attribute notes
OEL maximum inverse time output (Vinvmax). Typical value = 100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevinvmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vinvmini{695A5A82-2EDF-4ca4-BE73-6084582783FA}show detailsdid not existPU [0..1]OEL minimum inverse time output (Vinvmin). Typical value = 0.
Attribute notes
OEL minimum inverse time output (Vinvmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevinvmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax1i{44B4D3E8-C993-466d-8F32-8B4148CD1308}show detailsdid not existPU [0..1]Maximum OEL output limit (Voelmax1). Typical value = 10.
Attribute notes
Maximum OEL output limit (Voelmax1). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax2i{DD7204F0-7867-4a64-B713-07C6F9B21AAE}show detailsdid not existPU [0..1]Maximum OEL lead-lag 1 output limit (Voelmax2). Typical value = 100.
Attribute notes
Maximum OEL lead-lag 1 output limit (Voelmax2). Typical value = 100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax3i{D9AE1620-3EFD-4a09-91B8-310AA78AB64E}show detailsdid not existPU [0..1]Maximum OEL PID output limit (Voelmax3). Typical value = 100.
Attribute notes
Maximum OEL PID output limit (Voelmax3). Typical value = 100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmin1i{B3CAA2C2-871D-4933-AA61-7CFACFD3E1FD}show detailsdid not existPU [0..1]Minimum OEL output limit (Voelmin1). Typical value = -10.
Attribute notes
Minimum OEL output limit (Voelmin1). Typical value = -10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmin2i{DD359D90-38A9-4a7f-B6A9-92206D487BF2}show detailsdid not existPU [0..1]Minimum OEL lead-lag 1 output limit (Voelmin2). Typical value = -100.
Attribute notes
Minimum OEL lead-lag 1 output limit (Voelmin2). Typical value = -100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmin3i{C5043257-3E36-4f86-946C-E7FF1BCC79A8}show detailsdid not existPU [0..1]Minimum OEL PID output limit (Voelmin3). Typical value = -100.
Attribute notes
Minimum OEL PID output limit (Voelmin3). Typical value = -100.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙OverexcLimIEEEOEL3Ci
Class notes
IEEE 421.5-2016 OEL3C overexcitation limiter model. This model reduces voltage reference and thus terminal voltage in order to reduce field current according to an adjustable time characteristic. The reduction in voltage reference occurs whenever the actual excitation (field current) is greater than a pickup (reference) value. The pickup value is a constant value, which should be sufficient for representation of an OEL system in system studies. It should be recognized that the pickup value could be a function of the cold gas temperature of the generator, but that effect is not represented in this model. Reference: IEEE 421.5-2016, 10.6.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL3C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{0F50F696-195F-487e-982C-BF092B7B4A35}
Class notes
IEEE 421.5-2016 OEL3C overexcitation limiter model. This model reduces voltage reference and thus terminal voltage in order to reduce field current according to an adjustable time characteristic. The reduction in voltage reference occurs whenever the actual excitation (field current) is greater than a pickup (reference) value. The pickup value is a constant value, which should be sufficient for representation of an OEL system in system studies. It should be recognized that the pickup value could be a function of the cold gas temperature of the generator, but that effect is not represented in this model. Reference: IEEE 421.5-2016, 10.6.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL3C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
itfpui{A6ED5517-CCA2-4ef4-9638-3A4FD7C08AF9}show detailsdid not existPU [0..1]OEL timed field current limiter pick up level (Itfpu). Typically, Itfpu is expressed in per unit of the rated value for the selected input variable for the OEL model. Typical value = 3,7.
Attribute notes
OEL timed field current limiter pick up level (Itfpu). Typically, Itfpu is expressed in per unit of the rated value for the selected input variable for the OEL model. Typical value = 3,7.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameitfpu
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k1i{0920383E-9751-4b2b-8899-8A42A372E50A}show detailsdid not existFloat [0..1]Exponent for OEL error calculation (K1). Typical value = 1.
Attribute notes
Exponent for OEL error calculation (K1). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
koeli{A824786B-701C-4bdb-9EA1-703A88694611}show detailsdid not existPU [0..1]OEL gain (Koel). Typical value = 1.
Attribute notes
OEL gain (Koel). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekoel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpoeli{2ABA74BA-73A5-48de-8A5C-68CDDAF6915D}show detailsdid not existPU [0..1]OEL proportional gain (Kpoel). Typical value = 1.
Attribute notes
OEL proportional gain (Kpoel). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpoel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kscalei{77C39AE7-FF0C-4eba-AB33-8CACAE6F38D4}show detailsdid not existPU [0..1]OEL input signal scaling factor (Kscale). The parameter should be calculated based on the selection of the OEL input signal, to match the base value used for expressing Itfpu.
Attribute notes
OEL input signal scaling factor (Kscale). The parameter should be calculated based on the selection of the OEL input signal, to match the base value used for expressing Itfpu.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekscale
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tfi{EFB2942A-CAD6-4a67-B69F-3DAA74DCE4C9}show detailsdid not existSeconds [0..1]OEL field current measurement time constant (Tf) (>=0). Typical value = 0,02.
Attribute notes
OEL field current measurement time constant (Tf) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toeli{3E3C3FAA-B24F-4822-87BB-9C84B9FBF581}show detailsdid not existSeconds [0..1]OEL integral time constant (Toel) (>=0). Typical value = 24.
Attribute notes
OEL integral time constant (Toel) (>=0). Typical value = 24.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax1i{4851A8DE-3A0A-4619-864E-50FB5196415E}show detailsdid not existPU [0..1]OEL integrator maximum output (Voelmax1). Typical value = 0,66.
Attribute notes
OEL integrator maximum output (Voelmax1). Typical value = 0,66.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax2i{EC86AAB6-C468-4e93-B637-2CC6CA55AF5F}show detailsdid not existPU [0..1]OEL maximum output (Voelmax2). Typical value = 0.
Attribute notes
OEL maximum output (Voelmax2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmin1i{9FC2A89B-D3FF-4dd2-AE0C-1FF2EC8703B6}show detailsdid not existPU [0..1]OEL integrator minimum output (Voelmin1). Typical value = -1.
Attribute notes
OEL integrator minimum output (Voelmin1). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmin2i{661CE358-D741-44a9-A4A2-1367A73C58F2}show detailsdid not existPU [0..1]OEL minimum output (Voelmin2). Typical value = -1.
Attribute notes
OEL minimum output (Voelmin2). Typical value = -1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙OverexcLimIEEEOEL4Ci
Class notes
IEEE 421.5-2016 OEL4C overexcitation limiter model. This model acts to modify system excitation to limit reactive power from the generator. When generator reactive power output becomes greater than the adjustable pick-up value, the limiter should act to decrease excitation after a fixed-time delay. This limiter is also sometimes referred to as a var limiter. When applied to a conventional synchronous machine, this var limiter would modify the shape of the capability curve of the equipment and, possibly, reduce the reactive capability in the overexcited region. Reference: IEEE 421.5-2016, 10.7.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL4C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{5B899DEC-20AD-4ef7-89F5-9958F3365E69}
Class notes
IEEE 421.5-2016 OEL4C overexcitation limiter model. This model acts to modify system excitation to limit reactive power from the generator. When generator reactive power output becomes greater than the adjustable pick-up value, the limiter should act to decrease excitation after a fixed-time delay. This limiter is also sometimes referred to as a var limiter. When applied to a conventional synchronous machine, this var limiter would modify the shape of the capability curve of the equipment and, possibly, reduce the reactive capability in the overexcited region. Reference: IEEE 421.5-2016, 10.7.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL4C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
kii{32A69D86-6C77-4ec0-ADDC-45C7F438AC01}show detailsdid not existPU [0..1]OEL integral gain (Ki). Typical value = 1.
Attribute notes
OEL integral gain (Ki). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameki
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpi{4C67EFE7-735D-44ef-83C7-84616DFD3FA6}show detailsdid not existPU [0..1]OEL proportional gain (Kp). Typical value = 1.
Attribute notes
OEL proportional gain (Kp). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekp
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
qrefi{BA5C61AB-9070-4864-BC72-4295928C4D63}show detailsdid not existPU [0..1]OEL timed reactive power limiter pick up level (Qref). Typical value = 0,4.
Attribute notes
OEL timed reactive power limiter pick up level (Qref). Typical value = 0,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameqref
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
tdelayi{C74013BC-FFFD-4917-9502-5FBF78F40F4F}show detailsdid not existSeconds [0..1]OEL integral time constant (Tdelay) (>=0). Typical value = 20.
Attribute notes
OEL integral time constant (Tdelay) (>=0). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametdelay
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vmini{EDBF70CE-2F84-41e1-842E-40F117B51769}show detailsdid not existPU [0..1]OEL minimum output (Vmin). Typical value = -0,2.
Attribute notes
OEL minimum output (Vmin). Typical value = -0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙OverexcLimIEEEOEL5Ci
Class notes
IEEE 421.5-2016 OEL5C overexcitation limiter model. This model represents a take-over type function which replaces the normal input to the firing circuits. The output of the model is the result of either the generator field current regulator or the exciter field current regulator. Reference: IEEE 421.5-2016, 10.8.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL5C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{7084B1E5-CDAB-4914-AAF5-1A0DD4966C9A}
Class notes
IEEE 421.5-2016 OEL5C overexcitation limiter model. This model represents a take-over type function which replaces the normal input to the firing circuits. The output of the model is the result of either the generator field current regulator or the exciter field current regulator. Reference: IEEE 421.5-2016, 10.8.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameOverexcLimIEEEOEL5C
ParentPackageOverexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ibiasi{A92EE41E-1435-425b-B73F-5B1B607474B2}show detailsdid not existPU [0..1]OEL reference bias (Ibias). Typical value = 1.
Attribute notes
OEL reference bias (Ibias). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameibias
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdlimi{4D7E3115-2FD9-4f39-AF8D-40C6D357D0DF}show detailsdid not existPU [0..1]OEL inverse time limit active level (Ifdlim). Typical value = 6,58.
Attribute notes
OEL inverse time limit active level (Ifdlim). Typical value = 6,58.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdlim
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdpui{1BEE3680-B152-4a3b-9C97-59E1C295CE61}show detailsdid not existPU [0..1]OEL inverse time integrator pickup level (Ifdpu). Typical value = 1,02.
Attribute notes
OEL inverse time integrator pickup level (Ifdpu). Typical value = 1,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdpu
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdpulevi{818ED18C-1514-46a8-84CD-8A4805A6EE63}show detailsdid not existPU [0..1]OEL activation logic pickup level (Ifdpulev). Typical value = 1,4.
Attribute notes
OEL activation logic pickup level (Ifdpulev). Typical value = 1,4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdpulev
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdref1i{39157E0E-1890-4ab3-ADA5-9BA1A2DE7B3D}show detailsdid not existPU [0..1]OEL reference 1 (Ifdref1). Typical value = 1,25.
Attribute notes
OEL reference 1 (Ifdref1). Typical value = 1,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdref1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ifdref2i{65192226-283C-4390-9528-B8B086B42047}show detailsdid not existPU [0..1]OEL reference 2 (Ifdref2). Typical value = 1.
Attribute notes
OEL reference 2 (Ifdref2). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdref2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ki{3BD37026-3D8C-41bf-B4AE-7D184125B08C}show detailsdid not existPU [0..1]OEL lead-lag gain (K). Typical value = 1.
Attribute notes
OEL lead-lag gain (K). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k1i{FD05161A-2A84-42b0-A7C3-1296C4C176C4}show detailsdid not existFloat [0..1]Exponent for inverse time function (K1). Typical value = 1.
Attribute notes
Exponent for inverse time function (K1). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
kifdti{D4DA5617-DD45-4ce8-B8DC-3446C7D11447}show detailsdid not existPU [0..1]OEL inverse time leak gain (Kifdt). Typical value = 0,0043.
Attribute notes
OEL inverse time leak gain (Kifdt). Typical value = 0,0043.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekifdt
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kioeli{B653297B-0D20-43d6-821C-A57BA84511AA}show detailsdid not existPU [0..1]OEL integral gain (Kioel). Typical value = 17,36.
Attribute notes
OEL integral gain (Kioel). Typical value = 17,36.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekioel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kivfei{B5BE7B97-D5BE-4699-A7B8-7164D6280FE4}show detailsdid not existPU [0..1]Exciter field current regulator integral gain (Kivfe). Typical value = 0.
Attribute notes
Exciter field current regulator integral gain (Kivfe). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekivfe
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpoeli{0D516EE8-7A32-4f1b-A7B4-B54E04F8AFF6}show detailsdid not existPU [0..1]OEL proportional gain (Kpoel). Typical value = 0,46.
Attribute notes
OEL proportional gain (Kpoel). Typical value = 0,46.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpoel
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kpvfei{296C3B1F-119B-497d-BA34-8F72132D060B}show detailsdid not existPU [0..1]Exciter field current regulator proportional gain (Kpvfe). Typical value = 0.
Attribute notes
Exciter field current regulator proportional gain (Kpvfe). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekpvfe
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kscale1i{AD6D345F-A505-49e5-B962-D93605DBDA33}show detailsdid not existFloat [0..1]Scale factor for OEL input (Kscale1). Typical value = 0,295.
Attribute notes
Scale factor for OEL input (Kscale1). Typical value = 0,295.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekscale1
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
kscale2i{8FAB3D3D-CB6D-4f8f-B547-AC49DECF831A}show detailsdid not existFloat [0..1]Scale factor IFEbase/IFErated (Kscale2). Typical value = 0.
Attribute notes
Scale factor IFEbase/IFErated (Kscale2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekscale2
Scale0
Scopepublic
Staticfalse
TypeFloat
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{EDDB69A1-0398-4190-9190-6781849BDCFA}show detailsdid not existBoolean [0..1]OEL reference logic switch (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
OEL reference logic switch (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tboeli{C8E4AAD9-0BFC-40df-BBEA-834289A8351D}show detailsdid not existSeconds [0..1]OEL lag time constant (Tboel) (>=0). Typical value = 0.
Attribute notes
OEL lag time constant (Tboel) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametboel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tcoeli{52D6839E-6C11-458c-B08C-DCC258A61148}show detailsdid not existSeconds [0..1]OEL lead time constant (Tcoel) (>=0). Typical value = 0.
Attribute notes
OEL lead time constant (Tcoel) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametcoel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tf2i{2B524DE2-D13F-45e7-9B7C-F462071CAF63}show detailsdid not existSeconds [0..1]OEL input transducer time constant (Tf2) (>=0). Typical value = 0.
Attribute notes
OEL input transducer time constant (Tf2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametf2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tifdlevi{8D41B686-FC74-4fa3-9E93-AE66C8A32600}show detailsdid not existSeconds [0..1]OEL activation logic timer setpoint (Tifdlevl) (>=0). Typical value = 1.
Attribute notes
OEL activation logic timer setpoint (Tifdlevl) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametifdlev
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
toeli{21955F41-CAFD-4cff-A0AF-94A56F40465F}show detailsdid not existSeconds [0..1]OEL inverse time integrator time constant (Toel) (>=0). Typical value = 1.
Attribute notes
OEL inverse time integrator time constant (Toel) (>=0). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametoel
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vferefi{6155CC9D-5751-4310-AFC7-3FB1A5BC735A}show detailsdid not existPU [0..1]Exciter field current reference setpoint (Vferef). Typical value = 0.
Attribute notes
Exciter field current reference setpoint (Vferef). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevferef
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmaxi{0313B3DF-0668-4858-B300-B6791DF9DE00}show detailsdid not existPU [0..1]OEL PI control upper limit (Voelmax). Typical value = 1.
Attribute notes
OEL PI control upper limit (Voelmax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmax1i{CE21887F-8CDA-4149-96D8-B159E1D9E1E1}show detailsdid not existPU [0..1]OEL inverse time time upper limit (Voelmax1). Typical value = 9,49.
Attribute notes
OEL inverse time time upper limit (Voelmax1). Typical value = 9,49.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmax1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
voelmini{ED64273D-5211-4813-B34F-F9D3A903C80D}show detailsdid not existPU [0..1]OEL PI control lower limit (Voelmin). Typical value = -0,99.
Attribute notes
OEL PI control lower limit (Voelmin). Typical value = -0,99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevoelmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vvfemaxi{0C0C5478-9E69-4031-BAAA-666D80715185}show detailsdid not existPU [0..1]Exciter field current regulator upper limit (Vvfemax). Typical value = 1.
Attribute notes
Exciter field current regulator upper limit (Vvfemax). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevvfemax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vvfemini{8E8CD859-52EF-437e-A8E0-23ED93119EDB}show detailsdid not existPU [0..1]Exciter field current regulator lower limit (Vvfemin). Typical value = -0,99.
Attribute notes
Exciter field current regulator lower limit (Vvfemin). Typical value = -0,99.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevvfemin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed classes (5)
▶⚙OverexcitationLimiterDynamicsi
Class notes
Overexcitation limiter function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{9ADB0414-A6FA-47ab-A3B2-EA95E9551500}
Class notes
Overexcitation limiter function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL4C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL5C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcLimIEEEOEL3C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndOverexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙OverexcLim2i
Class notes (destination, redlined)
DifferentOverexcitation fromlimiter LimIEEEOEL,with LimOEL2 has a fixed pickup threshold. andIt reduces the excitation set-point by means of a non-windup integral regulator. <i>Irated</i> is the rated machine excitation current (calculated from nameplate conditions: <i>V</i><i><sub>nom</sub></i>, <i>P</i><i><sub>nom</sub></i>, <i>CosPhi</i><i><sub>nom</sub></i>).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C6018567-991D-4489-8F77-66EB34417ABD}
Class notes (destination, redlined)
DifferentOverexcitation fromlimiter LimIEEEOEL,with LimOEL2 has a fixed pickup threshold. andIt reduces the excitation set-point by means of a non-windup integral regulator. <i>Irated</i> is the rated machine excitation current (calculated from nameplate conditions: <i>V</i><i><sub>nom</sub></i>, <i>P</i><i><sub>nom</sub></i>, <i>CosPhi</i><i><sub>nom</sub></i>).
Class 'OverexcLim2' has no other changes. The shows its notes and every changed property.
▶⚙OverexcLimIEEEi
Class notes (destination, redlined)
The over excitation limiter model is intended to represent the significant features of OELs necessary for some large-scale system studies. It is the result of a pragmatic approach to obtain a model that can be widely applied with attainable data from generator owners. An attempt to include all variations in the functionality of OELs and duplicate how they interact with the rest of the excitation systems would likely result in a level of application insufficient for the studies for which they are intended. Reference: IEEE OEL 421.5-2005, 9 and IEEE 421.5-2016, 10.4.
Class metadata — changes
BaselineDestination
Stereotype(empty)deprecated
Tagged values — changes
BaselineDestination
no changes
CHANGED{123E0D03-692E-4567-A697-C64C50ABA7C7}
Class notes (destination, redlined)
The over excitation limiter model is intended to represent the significant features of OELs necessary for some large-scale system studies. It is the result of a pragmatic approach to obtain a model that can be widely applied with attainable data from generator owners. An attempt to include all variations in the functionality of OELs and duplicate how they interact with the rest of the excitation systems would likely result in a level of application insufficient for the studies for which they are intended. Reference: IEEE OEL 421.5-2005, 9 and IEEE 421.5-2016, 10.4.
▤Metadata
BaselineDestination
Stereotype(empty)deprecated
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
ifdratedi{FF776705-D916-499a-9E99-90A824F06EBB}show detailsdid not existPU [0..1]Rated field current (<i>I</i><i><sub>FDrated</sub></i>). Typical value = 2,5.
Attribute notes
Rated field current (<i>I</i><i><sub>FDrated</sub></i>). Typical value = 2,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameifdrated
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙OverexcLimX1i
Class notes
Field voltage over excitation limiter.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{04722CC0-52FA-45c2-BA1A-A4AF3A44EB2B}
Class notes
Field voltage over excitation limiter.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mstatusi{815FBEC0-7860-4079-85DB-2F2F2FDDBCA7}show detailsdid not existBoolean [0..1]Identifies the choice between using the inverse time characteristic and desired field voltage. True means usage of inverse time characteristic. False means usage of desired field voltage. Typical value = false.
Attribute notes
Identifies the choice between using the inverse time characteristic and desired field voltage. True means usage of inverse time characteristic. False means usage of desired field voltage. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemstatus
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vhighi{CD6ECC18-CCC9-42b1-AF67-42A1A0E87FB6}show detailsdid not existPU [0..1]High voltage limit (Vhigh) (> Vlow, >=0).
Attribute notes
High voltage limit (Vhigh) (> Vlow, >=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevhigh
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
▶⚙OverexcLimX2i
Class notes
Field voltage or current overexcitation limiter designed to protect the generator field of an AC machine with automatic excitation control from overheating due to prolonged overexcitation.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{50B12A55-58EB-4286-9D29-934B2E7E9539}
Class notes
Field voltage or current overexcitation limiter designed to protect the generator field of an AC machine with automatic excitation control from overheating due to prolonged overexcitation.
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
mstatusi{8B0EBE91-6A60-49fa-BF97-B757383A716F}show detailsdid not existBoolean [0..1]Identifies the choice between using the inverse time characteristic and desired field voltage. True means usage of inverse time characteristic. False means usage of desired field voltage. Typical value = false.
Attribute notes
Identifies the choice between using the inverse time characteristic and desired field voltage. True means usage of inverse time characteristic. False means usage of desired field voltage. Typical value = false.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namemstatus
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
vhighi{B09C617E-F65C-4e85-A4BA-5B1D60EEF564}show detailsdid not existPU [0..1]High voltage limit (Vhigh) (> Vlow, >=0).
Attribute notes
High voltage limit (Vhigh) (> Vlow, >=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevhigh
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
Changed diagrams (6)
▶▦OverexcitationLimiterDynamicsi
Diagram notes
This diagram shows dynamic standard model overexcitation limiter classes and their inheritance from the OverexcitationLimiterDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2013-09-15 22:01:522022-03-18 22:52:55
CHANGED{FC47C181-4791-474a-AB30-CF1D0E20F49F}
Diagram notes
This diagram shows dynamic standard model overexcitation limiter classes and their inheritance from the OverexcitationLimiterDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2013-09-15 22:01:522022-03-18 22:52:55
▦Diagram
addedchangedmoved or resized
Baseline
OverexcitationLimiterDynamics (baseline)
Destination
OverexcitationLimiterDynamics (destination)
Connectors 4 added · 3 reroutedhover a connector to outline the elements it joins
addedOverexcLimIEEEOEL2C – OverexcitationLimiterDynamics
addedOverexcLimIEEEOEL3C – OverexcitationLimiterDynamics
addedOverexcLimIEEEOEL4C – OverexcitationLimiterDynamics
addedOverexcLimIEEEOEL5C – OverexcitationLimiterDynamics
reroutedOverexcLimIEEE – OverexcitationLimiterDynamics
reroutedOverexcLimX1 – OverexcitationLimiterDynamics
reroutedOverexcitationLimiterUserDefined – OverexcitationLimiterDynamics
▶▦OverexcLim2i
Diagram notes
This diagram describes the OverexcLim2 overexcitation limiter model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:22:452022-03-18 22:52:49
CHANGED{9C3FC59A-4E64-4b0b-ADE6-C7047C642929}
Diagram notes
This diagram describes the OverexcLim2 overexcitation limiter model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:22:452022-03-18 22:52:49
Diagram 'OverexcLim2' has no other changes. The shows its notes and every changed property.
▶▦OverexcLimX1i
Diagram notes
This diagram describes the OverexcLimX1 overexcitation limiter model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:23:032022-03-18 22:52:43
CHANGED{868556D5-AF8A-45cf-8D52-A57E195A752E}
Diagram notes
This diagram describes the OverexcLimX1 overexcitation limiter model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:23:032022-03-18 22:52:43
Diagram 'OverexcLimX1' has no other changes. The shows its notes and every changed property.
▶▦OverexcLimX1TimeCharacteristici
Diagram notes
This model assumes an inverse time characteristic, where operating time is a function of the magnitude of the overvoltage.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:23:102022-03-18 22:52:37
CHANGED{7736616C-50AC-4df0-81EA-8B4AB9BE6B97}
Diagram notes
This model assumes an inverse time characteristic, where operating time is a function of the magnitude of the overvoltage.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:23:102022-03-18 22:52:37
Diagram 'OverexcLimX1TimeCharacteristic' has no other changes. The shows its notes and every changed property.
▶▦OverexcLimX2i
Diagram notes
This diagram describes the OverexcLimX2 overexcitation limiter model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:23:242022-03-18 22:52:30
CHANGED{4B1D9594-8AF6-4cc1-AE80-6A7716030B41}
Diagram notes
This diagram describes the OverexcLimX2 overexcitation limiter model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:23:242022-03-18 22:52:30
Diagram 'OverexcLimX2' has no other changes. The shows its notes and every changed property.
▶▦OverexcLimX2TimeCharacteristici
Diagram notes
This model assumes an inverse time characteristic, where operating time is a function of the magnitude of the overvoltage.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:23:292022-03-18 22:52:23
CHANGED{4E57E35B-0E77-4858-8590-082EF509799D}
Diagram notes
This model assumes an inverse time characteristic, where operating time is a function of the magnitude of the overvoltage.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:23:292022-03-18 22:52:23
Diagram 'OverexcLimX2TimeCharacteristic' has no other changes. The shows its notes and every changed property.
▶UnderexcitationLimiterDynamicsi
Package notes
Underexcitation limiters (UELs) act to boost excitation. The UEL typically senses either a combination of voltage and current of the synchronous machine or a combination of real and reactive power. Some UELs utilize a temperature or pressure recalibration feature, in which the UEL characteristic is shifted depending upon the generator cooling gas temperature or pressure.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/UnderexcitationLimiterDynamics/1.0
version(no tag)1.0.0
CHANGED{6601D8F5-D2D3-4743-A9D8-51CADC84A53A}
Package notes
Underexcitation limiters (UELs) act to boost excitation. The UEL typically senses either a combination of voltage and current of the synchronous machine or a combination of real and reactive power. Some UELs utilize a temperature or pressure recalibration feature, in which the UEL characteristic is shifted depending upon the generator cooling gas temperature or pressure.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/UnderexcitationLimiterDynamics/1.0
version(no tag)1.0.0
Added classes (1)
▶⚙UnderexcLimIEEEUEL2Ci
Class notes
IEEE 421.5-2016 UEL2C underexcitation limiter model. For this model, the UEL limit has either a straight-line or multisegment characteristic (piecewise linear) when plotted in terms of machine reactive power output versus real power output. Reference: IEEE 421.5-2016, 11.4.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameUnderexcLimIEEEUEL2C
ParentPackageUnderexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{DD014FCA-E848-4c48-9F44-2B5E484CFDF6}
Class notes
IEEE 421.5-2016 UEL2C underexcitation limiter model. For this model, the UEL limit has either a straight-line or multisegment characteristic (piecewise linear) when plotted in terms of machine reactive power output versus real power output. Reference: IEEE 421.5-2016, 11.4.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NameUnderexcLimIEEEUEL2C
ParentPackageUnderexcitationLimiterDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
k1i{A527FA50-43C9-4d1c-A954-6C734C7D04A5}show detailsdid not existPU [0..1]Voltage exponent for real power input to UEL table (K1). Typical value = 2.
Attribute notes
Voltage exponent for real power input to UEL table (K1). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
k2i{67E962D5-F66E-4591-AAF8-786D09B037D9}show detailsdid not existPU [0..1]Voltage exponent for reactive power output of UEL table (K2). Typical value = 2.
Attribute notes
Voltage exponent for reactive power output of UEL table (K2). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namek2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfbi{FA0EC244-53DE-4c88-A652-6CF5FD20C574}show detailsdid not existPU [0..1]UEL gain (Kfb). It is specific for the application of the IEEE UEL2C model in conjunction with the IEEE ST7C.
Attribute notes
UEL gain (Kfb). It is specific for the application of the IEEE UEL2C model in conjunction with the IEEE ST7C.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekfb
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kfixi{89EB66BE-580B-4554-94D1-718CCD1656A8}show detailsdid not existPU [0..1]UEL fixed gain reduction factor (Kfix). Typical value = 1.
Attribute notes
UEL fixed gain reduction factor (Kfix). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekfix
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kufi{3C401C8E-E511-4182-8181-5BEE22CE2E1F}show detailsdid not existPU [0..1]UEL excitation system stabilizer gain (Kuf). Typical value = 0.
Attribute notes
UEL excitation system stabilizer gain (Kuf). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekuf
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kuii{8DB71078-D3A3-469b-81D2-1A166F5CC15E}show detailsdid not existPU [0..1]UEL integral gain (Kui). Typical value = 0,5.
Attribute notes
UEL integral gain (Kui). Typical value = 0,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekui
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
kuli{F1BE8994-B707-432f-84E3-A1EA7AC60F39}show detailsdid not existPU [0..1]UEL proportional gain (Kul). Typical value = 0,8.
Attribute notes
UEL proportional gain (Kul). Typical value = 0,8.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namekul
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p0i{2D8FBC87-6BC0-437d-882E-586D2BC596AD}show detailsdid not existPU [0..1]UEL lookup table real power (first point) (P0). Typical value = 0.
Attribute notes
UEL lookup table real power (first point) (P0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p1i{78F20EBA-141C-44d6-925B-FEC57A989CBC}show detailsdid not existPU [0..1]UEL lookup table real power (second point) (P1). Typical value = 0,3.
Attribute notes
UEL lookup table real power (second point) (P1). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p2i{FB245426-84DF-4630-870B-1DAF7C11D05A}show detailsdid not existPU [0..1]UEL lookup table real power (third point) (P2). Typical value = 0,6.
Attribute notes
UEL lookup table real power (third point) (P2). Typical value = 0,6.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p3i{76B0EDF6-74F0-4267-8AAE-942740D2AC52}show detailsdid not existPU [0..1]UEL lookup table real power (fourth point) (P3). Typical value = 0,9.
Attribute notes
UEL lookup table real power (fourth point) (P3). Typical value = 0,9.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p4i{84DDC18F-8D3E-43a3-B4E0-6698592D39BD}show detailsdid not existPU [0..1]UEL lookup table real power (fifth point) (P4). Typical value = 1,02.
Attribute notes
UEL lookup table real power (fifth point) (P4). Typical value = 1,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep4
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p5i{19851155-7433-4826-95EB-F307EE2D1134}show detailsdid not existPU [0..1]UEL lookup table real power (sixth point) (P5).
Attribute notes
UEL lookup table real power (sixth point) (P5).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep5
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
p6i{77E3E143-319D-4642-9426-78B0D9B876DB}show detailsdid not existPU [0..1]UEL lookup table real power (seventh point) (P6).
Attribute notes
UEL lookup table real power (seventh point) (P6).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namep6
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q0i{0CD4F592-886F-4165-B66F-4940D941D5F3}show detailsdid not existPU [0..1]UEL lookup table reactive power (first point) (Q0). Typical value = -0,31.
Attribute notes
UEL lookup table reactive power (first point) (Q0). Typical value = -0,31.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq0
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q1i{0218DA56-3D2C-43c3-9927-2E01FF4C08D5}show detailsdid not existPU [0..1]UEL lookup table reactive power (second point) (Q1). Typical value = -0,31.
Attribute notes
UEL lookup table reactive power (second point) (Q1). Typical value = -0,31.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q2i{972F2858-CEB2-4eee-943A-C198EE9A6016}show detailsdid not existPU [0..1]UEL lookup table reactive power (third point) (Q2). Typical value = -0,28.
Attribute notes
UEL lookup table reactive power (third point) (Q2). Typical value = -0,28.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q3i{D020F2C2-C3C7-47f6-84C2-E543450BF134}show detailsdid not existPU [0..1]UEL lookup table reactive power (fourth point) (Q3). Typical value = -0,21.
Attribute notes
UEL lookup table reactive power (fourth point) (Q3). Typical value = -0,21.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q4i{830DA801-4D26-43fa-A969-98F1901E9431}show detailsdid not existPU [0..1]UEL lookup table reactive power (fifth point) (Q4). Typical value = 0.
Attribute notes
UEL lookup table reactive power (fifth point) (Q4). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq4
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q5i{A154DB0C-5BB0-44fd-B750-2E0EDF7E13AF}show detailsdid not existPU [0..1]UEL lookup table reactive power (sixth point) (Q5).
Attribute notes
UEL lookup table reactive power (sixth point) (Q5).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq5
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
q6i{B81643DD-C5BB-48b7-BAAC-492171406266}show detailsdid not existPU [0..1]UEL lookup table reactive power (seventh point) (Q6).
Attribute notes
UEL lookup table reactive power (seventh point) (Q6).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameq6
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
sw1i{530E2CC4-7D45-4721-A389-31A248B8E5C4}show detailsdid not existBoolean [0..1]UEL logic switch for adjustable gain reduction (SW1). True means position A. False means position B. Typical value = true.
Attribute notes
UEL logic switch for adjustable gain reduction (SW1). True means position A. False means position B. Typical value = true.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namesw1
Scale0
Scopepublic
Staticfalse
TypeBoolean
UpperBound1
Tagged values — changes
BaselineDestination
none
tadji{D0974350-9443-4dbc-8778-85ED5F5836D8}show detailsdid not existSeconds [0..1]UEL adjustable gain reduction time constant (Tadj) (>=0). Typical value = 3.
Attribute notes
UEL adjustable gain reduction time constant (Tadj) (>=0). Typical value = 3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametadj
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tqrefi{7FF2480C-20F6-4726-BCAC-5C11FF2565E2}show detailsdid not existSeconds [0..1]UEL reactive power reference time constant (Tqref) (>=0). Typical value = 0.
Attribute notes
UEL reactive power reference time constant (Tqref) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametqref
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tu1i{39C35771-C41F-4d93-ACFC-E2931E3AF515}show detailsdid not existSeconds [0..1]UEL numerator (lead) time constant (first block) (Tu1) (>=0). Typical value = 0.
Attribute notes
UEL numerator (lead) time constant (first block) (Tu1) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametu1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tu2i{71CB1CF1-5004-4f4a-8C66-E6B8EF2100A6}show detailsdid not existSeconds [0..1]UEL denominator (lag) time constant (first block) (Tu2) (>=0). Typical value = 0.
Attribute notes
UEL denominator (lag) time constant (first block) (Tu2) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametu2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tu3i{D95FBE8E-2FD9-4598-904A-48E880D6F918}show detailsdid not existSeconds [0..1]UEL numerator (lead) time constant (second block) (Tu3) (>=0). Typical value = 0.
Attribute notes
UEL numerator (lead) time constant (second block) (Tu3) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametu3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tu4i{8268315F-5994-4cf3-BC02-661FA9071391}show detailsdid not existSeconds [0..1]UEL denominator (lag) time constant (second block) (Tu4) (>=0). Typical value = 0.
Attribute notes
UEL denominator (lag) time constant (second block) (Tu4) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametu4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuli{4BA326B3-8EA6-47b9-B4E0-EC1B71D147AD}show detailsdid not existSeconds [0..1]UEL time constant (Tul) (>=0). It is specific for the application of the IEEE UEL2C model in conjunction with the IEEE ST7C.
Attribute notes
UEL time constant (Tul) (>=0). It is specific for the application of the IEEE UEL2C model in conjunction with the IEEE ST7C.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametul
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tupi{3F67DBE2-8B0E-4aa5-A487-E4311B2AD743}show detailsdid not existSeconds [0..1]UEL real power filter time constant (Tup) (>=0). Typical value = 5.
Attribute notes
UEL real power filter time constant (Tup) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametup
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuqi{9CB16D30-C1BD-45ab-AB3E-6661EB505E9F}show detailsdid not existSeconds [0..1]UEL reactive power filter time constant (Tuq) (>=0). Typical value = 0.
Attribute notes
UEL reactive power filter time constant (Tuq) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuq
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tuvi{B3F1D7DD-DEC0-4df1-A12A-BA6D9A445F19}show detailsdid not existSeconds [0..1]UEL voltage filter time constant (Tuv) (>=0). Typical value = 5.
Attribute notes
UEL voltage filter time constant (Tuv) (>=0). Typical value = 5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametuv
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vbiasi{5F047DF3-86FF-4748-B836-28CDAB65E7AF}show detailsdid not existPU [0..1]UEL voltage bias (Vbias). Typical value = 1.
Attribute notes
UEL voltage bias (Vbias). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevbias
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelmax1i{3BA14B21-1BAC-47d1-9DB1-44DA98BA6A6A}show detailsdid not existPU [0..1]UEL maximum output (Vuelmax1). Typical value = 0,25.
Attribute notes
UEL maximum output (Vuelmax1). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuelmax1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelmax2i{85F3889D-9979-4531-8935-C5F06936A352}show detailsdid not existPU [0..1]UEL maximum output (Vuelmax2). Typical value = 0.
Attribute notes
UEL maximum output (Vuelmax2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuelmax2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelmin1i{DFCDB107-9E0B-47f7-A872-78638BCCA94F}show detailsdid not existPU [0..1]UEL minimum output (Vuelmin1). Typical value = 0.
Attribute notes
UEL minimum output (Vuelmin1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuelmin1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vuelmin2i{99B201BE-CB3D-4989-A46D-8E06C3BD60F5}show detailsdid not existPU [0..1]UEL minimum output (Vuelmin2). Typical value = 0.
Attribute notes
UEL minimum output (Vuelmin2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevuelmin2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vulmaxi{A386C59B-C3DF-4e79-AF3E-600109E7E563}show detailsdid not existPU [0..1]UEL PI control maximum output (Vulmax). Typical value = 0,25.
Attribute notes
UEL PI control maximum output (Vulmax). Typical value = 0,25.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevulmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vulmini{6093C620-F38E-4d34-A3B8-E36CFC5695BE}show detailsdid not existPU [0..1]UEL PI control minimum output (Vulmin). Typical value = 0.
Attribute notes
UEL PI control minimum output (Vulmin). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevulmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndUnderexcLimIEEEUEL2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndUnderexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
Changed classes (4)
▶⚙UnderexcitationLimiterDynamicsi
Class notes
Underexcitation limiter function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C765F8F2-EACC-46ac-8EC1-62B38E9A38FF}
Class notes
Underexcitation limiter function block whose behaviour is described by reference to a standard model <font color="#0f0f0f">or by definition of a user-defined model.</font>
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndUnderexcLimIEEEUEL2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndUnderexcitationLimiterDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙UnderexcLim2Simplifiedi
Class notes (destination, redlined)
Simplified type UEL2 underexcitation limiter. This model can be derived from UnderexcLimIEEE2. The limit characteristic (look –-up table) is a single straight-line, the same as UnderexcLimIEEE2 (see Figure 10.4 (p 32), IEEE 421.5-2005, Section 10.2).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{C334B6E0-A80B-4211-BE69-4B7D894E379F}
Class notes (destination, redlined)
Simplified type UEL2 underexcitation limiter. This model can be derived from UnderexcLimIEEE2. The limit characteristic (look –-up table) is a single straight-line, the same as UnderexcLimIEEE2 (see Figure 10.4 (p 32), IEEE 421.5-2005, Section 10.2).
Class 'UnderexcLim2Simplified' has no other changes. The shows its notes and every changed property.
▶⚙UnderexcLimIEEE1i
Class notes (destination, redlined)
Type UEL1 model which has a circular limit boundary when plotted in terms of machine reactive power vs. real power output. Parameter details: <ol> <li>Vf signal applies only if the under excitation limiter is used in combination with IEEE 421.5 models.</li> </ol> Reference: IEEE UEL1 421.5-2005, 10.1 and IEEE 421.5-2016, 11.2.
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{8B14239E-961A-4d9a-817F-2F67CE6CDBC7}
Class notes (destination, redlined)
Type UEL1 model which has a circular limit boundary when plotted in terms of machine reactive power vs. real power output. Parameter details: <ol> <li>Vf signal applies only if the under excitation limiter is used in combination with IEEE 421.5 models.</li> </ol> Reference: IEEE UEL1 421.5-2005, 10.1 and IEEE 421.5-2016, 11.2.
Class 'UnderexcLimIEEE1' has no other changes. The shows its notes and every changed property.
▶⚙UnderexcLimIEEE2i
Class notes (destination, redlined)
Type UEL2 underexcitation limiter which has either a straight-line or multi-segment characteristic when plotted in terms of machine reactive power output vs. real power output. Parameter details: <ol> <li>Vf signal applies only if the under excitation limiter is used in combination with IEEE 421.5 models.</li> </ol> Reference: IEEE UEL2 421.5-2005, 10.2 (limit characteristic lookup table shown in Figure 10.4). According to IEEE 421.5-2016, 11.3 the UEL2 underexcitation limiter model is being superseded by the model UEL2C (p 32UnderexcLimIEEEUEL2C)).
Class metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
no changes
CHANGED{B375402B-97CA-4cb0-8481-5B4BAD2DC234}
Class notes (destination, redlined)
Type UEL2 underexcitation limiter which has either a straight-line or multi-segment characteristic when plotted in terms of machine reactive power output vs. real power output. Parameter details: <ol> <li>Vf signal applies only if the under excitation limiter is used in combination with IEEE 421.5 models.</li> </ol> Reference: IEEE UEL2 421.5-2005, 10.2 (limit characteristic lookup table shown in Figure 10.4). According to IEEE 421.5-2016, 11.3 the UEL2 underexcitation limiter model is being superseded by the model UEL2C (p 32UnderexcLimIEEEUEL2C)).
Class 'UnderexcLimIEEE2' has no other changes. The shows its notes and every changed property.
Changed diagrams (4)
▶▦UnderexcitationLimiterDynamicsi
Diagram notes
This diagram shows dynamic standard model underexcitation limiter classes and their inheritance from the UnderexcitationLimiterDynamics class.
Diagram metadata — changes
BaselineDestination
ModifiedDate2016-09-12 09:44:452022-03-18 22:53:56
CHANGED{02C1E27A-FA01-4b4b-B496-F6BEDA3C6717}
Diagram notes
This diagram shows dynamic standard model underexcitation limiter classes and their inheritance from the UnderexcitationLimiterDynamics class.
▤Metadata
BaselineDestination
ModifiedDate2016-09-12 09:44:452022-03-18 22:53:56
▦Diagram
addedchanged
Baseline
UnderexcitationLimiterDynamics (baseline)
Destination
UnderexcitationLimiterDynamics (destination)
Connectors 1 added · 1 reroutedhover a connector to outline the elements it joins
addedUnderexcLimIEEEUEL2C – UnderexcitationLimiterDynamics
reroutedUnderexcLimIEEE2 – UnderexcitationLimiterDynamics
▶▦UnderexcLim2Simplifiedi
Diagram notes
This diagram describes the UnderexcLim2Simplified underexcitation limiter model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:24:162022-03-18 22:53:50
CHANGED{4F92A42B-638A-4d4d-B5A6-7A1C99A1EA76}
Diagram notes
This diagram describes the UnderexcLim2Simplified underexcitation limiter model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:24:162022-03-18 22:53:50
Diagram 'UnderexcLim2Simplified' has no other changes. The shows its notes and every changed property.
▶▦UnderexcLimX1i
Diagram notes (destination, redlined)
This diagram describes the UnderexcLimX1 underexcitation limiter model. Parameter details: <ol> <li><i>I</i><i><sub>REAL</sub></i> is the realactive partcurrent of statorthe generator current(Pgen/Vgen).</li> <li><i>XADIFD</i> is the signal <i>Ifd</i> as shown in the diagram of the SubtransientRoundRotor model, i.e. the <i>XADIFD</i> = <i>E’q</i> + [(<i>E’q</i> - <i>psid</i>) x (<i>Xd</i> - <i>X'd</i>) x (<i>X'd</i> - <i>X"d</i>) + <i>Id</i> x (<i>Xd</i> - <i>X’d</i>) x (<i>X"d</i> - <i>Xl</i>) x (<i>X'd</i> – <i>Xl</i>)] / (<i>X'd</i> - <i>Xl</i>) ** 2, where the psi in psid is the Greek symbol psi. </li> </ol>
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:24:372022-03-18 22:53:41
CHANGED{20D952F7-BA5A-4d45-8456-EB10E41A2769}
Diagram notes (destination, redlined)
This diagram describes the UnderexcLimX1 underexcitation limiter model. Parameter details: <ol> <li><i>I</i><i><sub>REAL</sub></i> is the realactive partcurrent of statorthe generator current(Pgen/Vgen).</li> <li><i>XADIFD</i> is the signal <i>Ifd</i> as shown in the diagram of the SubtransientRoundRotor model, i.e. the <i>XADIFD</i> = <i>E’q</i> + [(<i>E’q</i> - <i>psid</i>) x (<i>Xd</i> - <i>X'd</i>) x (<i>X'd</i> - <i>X"d</i>) + <i>Id</i> x (<i>Xd</i> - <i>X’d</i>) x (<i>X"d</i> - <i>Xl</i>) x (<i>X'd</i> – <i>Xl</i>)] / (<i>X'd</i> - <i>Xl</i>) ** 2, where the psi in psid is the Greek symbol psi. </li> </ol>
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:24:372022-03-18 22:53:41
Diagram 'UnderexcLimX1' has no other changes. The shows its notes and every changed property.
▶▦UnderexcLimX2i
Diagram notes
This diagram describes the UnderexcLimX2 underexcitation limiter model.
Diagram metadata — changes
BaselineDestination
ModifiedDate2017-09-27 20:25:002022-03-18 22:53:35
CHANGED{EB5B4FEC-E774-47e8-B077-5CEC76214978}
Diagram notes
This diagram describes the UnderexcLimX2 underexcitation limiter model.
▤Metadata
BaselineDestination
ModifiedDate2017-09-27 20:25:002022-03-18 22:53:35
Diagram 'UnderexcLimX2' has no other changes. The shows its notes and every changed property.
▶PowerSystemStabilizerDynamicsi
Package notes
The power system stabilizer (PSS) model provides an input (<i>Vs</i>) to the excitation system model to improve damping of system oscillations. A variety of input signals can be used depending on the particular design.
Package metadata — changes
BaselineDestination
no changes
Tagged values — changes
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/PowerSystemStabilizerDynamics/1.0
version(no tag)1.0.0
CHANGED{15788FE9-6C55-412c-8AB7-F3F1EB004BDF}
Package notes
The power system stabilizer (PSS) model provides an input (<i>Vs</i>) to the excitation system model to improve damping of system oscillations. A variety of input signals can be used depending on the particular design.
Tagged values
BaselineDestination
uri(no tag)http://iec.ch/TC57/CIM/PowerSystemStabilizerDynamics/1.0
version(no tag)1.0.0
Added classes (6)
▶⚙PssIEEE2Ci
Class notes
IEEE 421.5-2016 PSS2C power system stabilizer model. It is is designed to represent a variety of dual-input stabilizers, which normally use combinations of power and speed (or frequency, or compensated frequency) to derive the stabilizing signal. Reference: IEEE 421.5-2016, 9.5.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NamePssIEEE2C
ParentPackagePowerSystemStabilizerDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{A4AF1994-CBFE-42ab-8A60-481D9CD1CB20}
Class notes
IEEE 421.5-2016 PSS2C power system stabilizer model. It is is designed to represent a variety of dual-input stabilizers, which normally use combinations of power and speed (or frequency, or compensated frequency) to derive the stabilizing signal. Reference: IEEE 421.5-2016, 9.5.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NamePssIEEE2C
ParentPackagePowerSystemStabilizerDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
inputSignal1Kindi{269D87AF-19EE-436d-8A99-F395630CA967}show detailsdid not existInputSignalKind [0..1]Type of input signal #1 (rotorSpeed, rotorAngularFrequencyDeviation, busFrequencyDeviation, busFrequency). Typical value = rotorAngularFrequencyDeviation.
Attribute notes
Type of input signal #1 (rotorSpeed, rotorAngularFrequencyDeviation, busFrequencyDeviation, busFrequency). Typical value = rotorAngularFrequencyDeviation.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NameinputSignal1Kind
Scale0
Scopepublic
Staticfalse
TypeInputSignalKind
UpperBound1
Tagged values — changes
BaselineDestination
none
inputSignal2Kindi{E396A45C-1D77-41aa-8397-8812C1EDE389}show detailsdid not existInputSignalKind [0..1]Type of input signal #2 (generatorElectricalPower). Typical value = generatorElectricalPower.
Attribute notes
Type of input signal #2 (generatorElectricalPower). Typical value = generatorElectricalPower.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NameinputSignal2Kind
Scale0
Scopepublic
Staticfalse
TypeInputSignalKind
UpperBound1
Tagged values — changes
BaselineDestination
none
ks1i{CA98B5E2-EC0A-4def-8C62-9FE1F03B39B4}show detailsdid not existPU [0..1]PSS gain (Ks1). Typical value = 20.
Attribute notes
PSS gain (Ks1). Typical value = 20.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameks1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ks2i{EB9A6197-10EF-4f3b-994B-9EBBD1656CD6}show detailsdid not existPU [0..1]PSS gain (Ks2). The gain KS2 should be calculated as T7/2H, where H is the total shaft inertia of all mechanically connected rotating components of the unit (MW-s/MVA).
Attribute notes
PSS gain (Ks2). The gain KS2 should be calculated as T7/2H, where H is the total shaft inertia of all mechanically connected rotating components of the unit (MW-s/MVA).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameks2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ks3i{FA7FFE00-F47B-4a1a-8C66-E97AD67C8CF0}show detailsdid not existPU [0..1]PSS gain (Ks3). Typical value = 1.
Attribute notes
PSS gain (Ks3). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameks3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
mi{0D2F9C85-6F7E-4e28-81A1-CD122FD2A313}show detailsdid not existInteger [0..1]PSS transducer time constant (M). Typical value = 2.
Attribute notes
PSS transducer time constant (M). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namem
Scale0
Scopepublic
Staticfalse
TypeInteger
UpperBound1
Tagged values — changes
BaselineDestination
none
ni{250F1416-B6EA-41be-B1DB-2BBE4946B717}show detailsdid not existInteger [0..1]PSS washout time constant (N). Typical value = 4.
Attribute notes
PSS washout time constant (N). Typical value = 4.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namen
Scale0
Scopepublic
Staticfalse
TypeInteger
UpperBound1
Tagged values — changes
BaselineDestination
none
ppssoffi{DBD81B19-A3DA-4e8e-9C1F-815703B85101}show detailsdid not existPU [0..1]Generator MW threshold for PSS activation (Ppssoff). Typical value = 0.
Attribute notes
Generator MW threshold for PSS activation (Ppssoff). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameppssoff
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ppssoni{C417E3CD-120C-449c-8D15-ACAF5A74D71A}show detailsdid not existPU [0..1]Generator MW threshold for PSS activation (Ppsson). Typical value = 0.
Attribute notes
Generator MW threshold for PSS activation (Ppsson). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameppsson
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{5C7AC70E-A1C1-4193-AB9B-F76C1FA4E5EB}show detailsdid not existSeconds [0..1]PSS numerator (lead) compensating time constant (first block) (T1) (>=0). Typical value = 0,16.
Attribute notes
PSS numerator (lead) compensating time constant (first block) (T1) (>=0). Typical value = 0,16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t10i{DA1EB729-AA1A-40c8-A230-ACA163FB6E43}show detailsdid not existSeconds [0..1]PSS numerator (lead) compensating time constant (third block) (T10) (>=0).
Attribute notes
PSS numerator (lead) compensating time constant (third block) (T10) (>=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet10
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t11i{572334BB-2392-4546-BC21-25FB46718E5A}show detailsdid not existSeconds [0..1]PSS denominator (lag) compensating time constant (third block) (T11) (>=0).
Attribute notes
PSS denominator (lag) compensating time constant (third block) (T11) (>=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet11
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t12i{9D2E1317-1A17-427d-8C2B-54D726592134}show detailsdid not existSeconds [0..1]PSS numerator (lead) compensating time constant (fourth block) (T12) (>=0).
Attribute notes
PSS numerator (lead) compensating time constant (fourth block) (T12) (>=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet12
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t13i{A7922010-D861-4b00-B3D4-4B31790B0851}show detailsdid not existSeconds [0..1]PSS denominator (lag) compensating time constant (fourth block) (T13) (>=0).
Attribute notes
PSS denominator (lag) compensating time constant (fourth block) (T13) (>=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet13
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t2i{A40DA442-C176-45d0-90C1-8FC6597C5451}show detailsdid not existSeconds [0..1]PSS denominator (lag) compensating time constant (first block) (T2) (>=0). Typical value = 0,02.
Attribute notes
PSS denominator (lag) compensating time constant (first block) (T2) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t3i{EF35643C-5ED8-475e-9AE7-DDA56D4F0C31}show detailsdid not existSeconds [0..1]PSS numerator (lead) compensating time constant (second block) (T3) (>=0). Typical value = 0,16.
Attribute notes
PSS numerator (lead) compensating time constant (second block) (T3) (>=0). Typical value = 0,16.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t4i{C50FE288-F5E0-4633-9AB4-8A39ED64D57A}show detailsdid not existSeconds [0..1]PSS numerator (lag) compensating time constant (second block) (T4) (>=0). Typical value = 0,02.
Attribute notes
PSS numerator (lag) compensating time constant (second block) (T4) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t6i{DA841983-2CCB-4e8d-B1D2-B291BBC57869}show detailsdid not existSeconds [0..1]PSS transducer time constant (T6) (>=0). Typical value = 0.
Attribute notes
PSS transducer time constant (T6) (>=0). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet6
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t7i{73CD2E68-1AA1-4890-B7F3-F99D3B12CC88}show detailsdid not existSeconds [0..1]PSS transducer time constant (T7) (>=0). It should be equal to Tw2. Typical value = 10.
Attribute notes
PSS transducer time constant (T7) (>=0). It should be equal to Tw2. Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet7
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t8i{A22F1D37-817A-4f99-A7A7-0749742EE15E}show detailsdid not existSeconds [0..1]PSS transducer time constant (T8) (>=0). Typical value = 0,3.
Attribute notes
PSS transducer time constant (T8) (>=0). Typical value = 0,3.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet8
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t9i{C822B7DB-0FD0-4d4a-A731-DB563AB132C6}show detailsdid not existSeconds [0..1]PSS washout time constant (T9) (>=0). Typical value = 0,15.
Attribute notes
PSS washout time constant (T9) (>=0). Typical value = 0,15.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet9
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw1i{7C15EEA9-E755-4688-9FCC-CA2F6A6746DC}show detailsdid not existSeconds [0..1]PSS washout time constant (Tw1) (>=0). Typical value = 10.
Attribute notes
PSS washout time constant (Tw1) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw2i{9E25C18A-2321-431e-B85D-8564308906D5}show detailsdid not existSeconds [0..1]PSS washout time constant (Tw2) (>=0). Typical value = 10.
Attribute notes
PSS washout time constant (Tw2) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw3i{39982BA2-D06D-4dad-A5AE-A043F48C1B26}show detailsdid not existSeconds [0..1]PSS washout time constant (Tw3) (>=0). Typical value = 10.
Attribute notes
PSS washout time constant (Tw3) (>=0). Typical value = 10.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw3
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw4i{3558C84C-CA90-4fe8-9CD0-CA4F18054399}show detailsdid not existSeconds [0..1]PSS washout time constant (Tw4) (>=0).
Attribute notes
PSS washout time constant (Tw4) (>=0).
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw4
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi1maxi{217384E8-8581-49a2-8D9B-E8AF6B906F3D}show detailsdid not existPU [0..1]Input signal #1 maximum limit (Vsi1max). Typical value = 2.
Attribute notes
Input signal #1 maximum limit (Vsi1max). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevsi1max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi1mini{2566D0AC-5BEF-4303-B7C8-8038E579BFA2}show detailsdid not existPU [0..1]Input signal #1 minimum limit (Vsi1min). Typical value = -2.
Attribute notes
Input signal #1 minimum limit (Vsi1min). Typical value = -2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevsi1min
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi2maxi{379884D3-334F-4244-BD90-5DC1AA681BA1}show detailsdid not existPU [0..1]Input signal #2 maximum limit (Vsi2max). Typical value = 2.
Attribute notes
Input signal #2 maximum limit (Vsi2max). Typical value = 2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevsi2max
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vsi2mini{4F06D6B9-19A6-4b64-950B-EA20B19CE1DF}show detailsdid not existPU [0..1]Input signal #2 minimum limit (Vsi2min). Typical value = -2.
Attribute notes
Input signal #2 minimum limit (Vsi2min). Typical value = -2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevsi2min
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vstmaxi{5E2C256A-A099-4366-B6D8-289BFD90B5AF}show detailsdid not existPU [0..1]Maximum PSS output (Vstmax). Typical value = 0,2.
Attribute notes
Maximum PSS output (Vstmax). Typical value = 0,2.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevstmax
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
vstmini{B5330AF5-C0A1-4be1-8306-0E262782900C}show detailsdid not existPU [0..1]Minimum PSS output (Vstmin). Typical value = -0,066.
Attribute notes
Minimum PSS output (Vstmin). Typical value = -0,066.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namevstmin
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
⇄Links
Baselinedid not exist
→
Link metadata
BaselineDestination
DirectionSource -> Destination
TypeGeneralization
Source end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndPssIEEE2C
IsAggregation0
IsChangeablenone
IsNavigablefalse
Orderingfalse
ScopePublic
TargetScopeinstance
Target end
BaselineDestination
Cardinality0
ContainmentUnspecified
EndPowerSystemStabilizerDynamics
IsAggregation0
IsChangeablenone
IsNavigabletrue
Orderingfalse
ScopePublic
TargetScopeinstance
▶⚙PssIEEE3Ci
Class notes
IEEE 421.5-2016 PSS3C power system stabilizer model. It has dual inputs, usually generator electrical power output (VSI1 = PT) and rotor angular speed deviation (VSI2 = delta omega). The signals are used to derive an equivalent mechanical power signal. Reference: IEEE 421.5-2016, 9.7.
Class metadata — changes
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NamePssIEEE3C
ParentPackagePowerSystemStabilizerDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
Tagged values — changes
BaselineDestination
none
ADDED{1F25FA2A-7E16-412a-9C8D-5A9F64824630}
Class notes
IEEE 421.5-2016 PSS3C power system stabilizer model. It has dual inputs, usually generator electrical power output (VSI1 = PT) and rotor angular speed deviation (VSI2 = delta omega). The signals are used to derive an equivalent mechanical power signal. Reference: IEEE 421.5-2016, 9.7.
▤Metadata
BaselineDestination
Abstractfalse
AuthorChavdarIvanov
Complexity1
GenTypeJava
IsLeaffalse
IsRootfalse
IsSpecfalse
NamePssIEEE3C
ParentPackagePowerSystemStabilizerDynamics
Phase1.0
Scopepublic
StatusProposed
TypeClass
Version1.0
≡Attributes
AttributeBaselineDestinationNotes (destination, redlined)
a1i{4B8CD01F-582F-4315-9AD2-F332A33F23B8}show detailsdid not existPU [0..1]PSS numerator coefficient (first block) (A1). Typical value = 0.
Attribute notes
PSS numerator coefficient (first block) (A1). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a2i{217AEB2A-FFB4-4e92-A230-F28944954F9C}show detailsdid not existPU [0..1]PSS numerator coefficient (first block) (A2). Typical value = 0.
Attribute notes
PSS numerator coefficient (first block) (A2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a3i{85BBB57E-0DEA-46a8-959F-A2EA699607BF}show detailsdid not existPU [0..1]PSS denominator coefficient (first block) (A3). Typical value = 0,02.
Attribute notes
PSS denominator coefficient (first block) (A3). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea3
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a4i{9C3BB4F1-53F6-4df8-8B43-A91ABFC4E738}show detailsdid not existPU [0..1]PSS denominator coefficient (first block) (A4). Typical value = 0.
Attribute notes
PSS denominator coefficient (first block) (A4). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea4
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a5i{CD4F8BC8-B5B8-4ad9-AB51-00D0FB899CD6}show detailsdid not existPU [0..1]PSS numerator coefficient (second block) (A5). Typical value = 0.
Attribute notes
PSS numerator coefficient (second block) (A5). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea5
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a6i{496FD383-958E-4558-9E0D-3E522203CB4B}show detailsdid not existPU [0..1]PSS numerator coefficient (second block) (A6). Typical value = 0.
Attribute notes
PSS numerator coefficient (second block) (A6). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea6
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a7i{B6502165-8D62-4d02-8DD9-9AD1075EB93E}show detailsdid not existPU [0..1]PSS denominator coefficient (second block) (A7). Typical value = 0.
Attribute notes
PSS denominator coefficient (second block) (A7). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea7
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
a8i{3712D626-19BE-42a8-8ED7-5399BFE5B695}show detailsdid not existPU [0..1]PSS denominator coefficient (second block) (A8). Typical value = 0.
Attribute notes
PSS denominator coefficient (second block) (A8). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namea8
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
inputSignal1Kindi{18E39864-3DB3-4582-B1F4-B6B580AC5AE6}show detailsdid not existInputSignalKind [0..1]Type of input signal #1 (generatorElectricalPower). Typical value = generatorElectricalPower.
Attribute notes
Type of input signal #1 (generatorElectricalPower). Typical value = generatorElectricalPower.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NameinputSignal1Kind
Scale0
Scopepublic
Staticfalse
TypeInputSignalKind
UpperBound1
Tagged values — changes
BaselineDestination
none
inputSignal2Kindi{E7A18F2C-E935-4b53-A790-40FC4070194A}show detailsdid not existInputSignalKind [0..1]Type of input signal #2 (rotorAngularFrequencyDeviation). Typical value = rotorAngularFrequencyDeviation.
Attribute notes
Type of input signal #2 (rotorAngularFrequencyDeviation). Typical value = rotorAngularFrequencyDeviation.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
NameinputSignal2Kind
Scale0
Scopepublic
Staticfalse
TypeInputSignalKind
UpperBound1
Tagged values — changes
BaselineDestination
none
ks1i{49BF98E7-7D86-4c72-A90F-0EC8DD18D911}show detailsdid not existPU [0..1]Power system stabilizer gain for input channel 1 (Ks1). Typical value = 1.
Attribute notes
Power system stabilizer gain for input channel 1 (Ks1). Typical value = 1.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameks1
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ks2i{EE41ED1C-3AF2-4a48-AD29-9CFACC0E52A3}show detailsdid not existPU [0..1]Power system stabilizer gain for input channel 2 (Ks2). Typical value = 0.
Attribute notes
Power system stabilizer gain for input channel 2 (Ks2). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameks2
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ppssoffi{EBFE617A-08AA-4b92-95ED-67200B19C9FE}show detailsdid not existPU [0..1]Generator MW threshold for PSS activation (Ppssoff). Typical value = 0.
Attribute notes
Generator MW threshold for PSS activation (Ppssoff). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameppssoff
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
ppssoni{7A75430D-10AE-4050-AD74-F9F1606DCBE2}show detailsdid not existPU [0..1]Generator MW threshold for PSS activation (Ppsson). Typical value = 0.
Attribute notes
Generator MW threshold for PSS activation (Ppsson). Typical value = 0.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nameppsson
Scale0
Scopepublic
Staticfalse
TypePU
UpperBound1
Tagged values — changes
BaselineDestination
none
t1i{F18E3C39-B971-48d0-BE2A-38363B6867EB}show detailsdid not existSeconds [0..1]PSS transducer time constant for input channel 1 (T1) (>=0). Typical value = 0,02.
Attribute notes
PSS transducer time constant for input channel 1 (T1) (>=0). Typical value = 0,02.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
t2i{119DC5F5-B985-4b26-BB58-42206B9C52DD}show detailsdid not existSeconds [0..1]PSS transducer time constant for input channel 2 (T2) (>=0). Typical value = 1,5.
Attribute notes
PSS transducer time constant for input channel 2 (T2) (>=0). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Namet2
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw1i{9E739BC3-74A2-49d9-BC16-8C96BEF8B88E}show detailsdid not existSeconds [0..1]Washout time constant (input channel 1) (Tw1) (>=0). Typical value = 1,5.
Attribute notes
Washout time constant (input channel 1) (Tw1) (>=0). Typical value = 1,5.
Attribute metadata — changes
BaselineDestination
AllowDuplicatesfalse
Collectionfalse
Constfalse
ContainmentNot Specified
IsOrderedfalse
LowerBound0
Nametw1
Scale0
Scopepublic
Staticfalse
TypeSeconds
UpperBound1
Tagged values — changes
BaselineDestination
none
tw2i{4038D7F2-0910-4eaa-9054-F69EAA719B3A}show detailsdid not existSeconds [0..1]Washout time constant (input channel 2) (Tw2) (>=0). Typical valu